Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SYMPTOMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Percutaneous Endovascular Radiofrequency Ablation for Malignant Portal Obstruction: An Initial Clinical Experience

PurposeThe Habib™ VesOpen Catheter is a new endovascular radiofrequency ablation (RFA) device used to treat malignant portal obstruction. The purpose of this study was to evaluate the clinical feasibility and safety of RFA with this device.MethodsWe collected the clinical records and follow-up data of patients with malignant portal obstruction treated with percutaneous endovascular portal RFA using the Habib™ VesOpen Catheter. Procedure-related complications, improvement of symptoms, portal patency, survival, and postoperative biochemical tests were investigated.ResultsThe 31 patients enrolled in the study underwent 41 successful endovascular portal RFA procedures. Patients were divided into a portal-stenting (PS) group (n = 13), which underwent subsequent portal stenting with self-expandable metallic stents, and a non-stenting (NS) group (n = 18), which did not undergo stenting. No procedure-related abdominal hemorrhage or portal rupture occurred. Postablation complications included abdominal pain (n = 26), fever (n = 13), and pleural effusion (n = 15). Improvements in clinical manifestations were observed in 27 of the 31 patients. Of the 17 patients experiencing portal restenosis, 10 underwent successful repeat RFA. The rate of successful repeat RFA was significantly higher in the NS group than in the PS group. Median portal patency was shorter in the PS group than in the NS group. No mortality occurred during the 4 weeks after percutaneous endovascular portal RFA.ConclusionsPercutaneous endovascular portal RFA is a feasible and safe therapeutic option for malignant portal obstruction. Prospective investigations should be performed to evaluate clinical efficacy, in particular, the need to evaluate the necessity for subsequent portal stenting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Effectiveness of Embolization in Pelvic Congestion Syndrome with the New Vascular Occlusion Device (ArtVentive EOS™): Preliminary Results

PurposeThis study aimed to collect confirmatory data in support of the safety and efficiency of the ArtVentive EOS™ for the treatment of the pelvic congestion syndrome (PCS). This study was based on the OCCLUDE 1 Study Protocol approved by the Local Ethics Committee.Materials and MethodsA prospective study carried out in June and July 2014 included 12 women aged 21–48 years (mean 31 years) scheduled for PCS embolization using the ArtVentive EOS™. The inclusion criteria were clinical symptoms of PCS documented by transvaginal Doppler ultrasound and pelvic MRI. The pelvic pain was assessed by VAS score from 0 to 10 (0 represents lack of pain and 10 unbearable pain). A decrease in pelvic pain intensity based on the VAS was considered a clinical success.ResultsSuccessful embolization procedures with ArtVentive EOS™ were performed in 11 out of 12 patients. Nine patients underwent unilateral embolization of the left ovarian vein, and two had bilateral embolization of the ovarian veins. Complete ovarian vein occlusion confirmed by post deployment venography was achieved in all 11 patients. Procedures lasted from 19 to 45 min (average 28 min). Pain intensity decrease was observed in all 11 patients—a decrease of 5.6 points—from 7.3 pre-procedure to 1.6 post-embolization (standard deviation: 0.67). In one case, the left ovarian vein was injured by guide wire manipulation with contrast extravasation—not clinically significant.ConclusionsThe use of ArtVentive EOS™ for occlusion of the ovarian veins in PCS patients is safe and effective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Flow Vascular Malformation in the Sigmoid Mesentery Successfully Treated with a Combination of Transarterial and Transvenous Embolization

Mesenteric high-flow vascular malformation can cause various clinical symptoms and demand specific therapeutic interventions owing to its peculiar hemodynamics. We report a case of high-flow vascular malformation in the sigmoid mesentery which presented with ischemic colitis. The main trunk of the inferior mesenteric vein was occluded. After partially effective transarterial embolization, transvenous embolization was performed using a microballoon catheter advanced to the venous component of the lesion via the marginal vein. Complete occlusion of the lesion was achieved. Combination of transarterial and transvenous embolization may allow us to apply endovascular treatment to a wider variety of high-flow lesions in the area and possibly avoid the bowel resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Cementoplasty for Kienbock’s Disease

Kienböck disease typically presents with wrist pain, swelling, restricted range of motion, and difficulty in performing activities of daily living. Because the etiology and evolution of disease remain unclear, broad ranges of treatments have been designed. Percutaneous cementoplasty is expanding its role for managing painful bone metastases outside the spine. We can draw a parallel between lytic tumoral lesions and Kienbock’s disease. Increasing the strength and rigidity of lunate with cementoplasty can prevent it from collapse, relieve the symptoms associated with the process of avascular necrosis, and increase the wrist range of motion. We report the case of 30-year-old man with a painful stage IIIA Kienböck disease who underwent percutaneous cementoplasty and experienced immediate effective pain relief and recovery of wrist mobility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes After Transarterial Embolization of Neuroendocrine Tumor Liver Metastases Using Spherical Particles of Different Sizes

Purpose: To evaluate initial response and overall survival of neuroendocrine tumor (NET) liver metastases initially treated with transarterial embolization (TAE) using spherical particles of different sizes. Methods: A single-institution retrospective review was performed of 160 patients with NET liver metastases initially treated with TAE using < 100 µm (n = 77) or only ≥ 100 µm (n = 83) spherical particles. For each patient, we evaluated: initial response by mRECIST, time to progression, overall survival, complications, primary site, tumor grade and degree of differentiation, volume of liver disease, extrahepatic disease, NET-related symptoms, comorbidities, Child–Pugh score, performance status, lobar versus selective embolization, and arteriovenous shunting. Results: Initial response was higher for TAE using particles < 100 versus TAE using only particles ≥ 100 μm (64 vs 42%, p = 0.007). Multivariate logistic regression showed that use of particles < 100 μm and liver < 50% replaced with tumor were independent predictors of a better initial response rate. There was no difference in major or minor complications between the two particle size groups. Median overall survival after TAE was 55 months for well- to moderately differentiated NET and 13 months for poorly differentiated or undifferentiated NET. There was no significant difference in survival between TAE patients treated with < 100 versus only ≥ 100-μm particles. Conclusion: NET patients treated with TAE using particles < 100 μm had better initial response, but the same overall survival, compared to TAE using only particles ≥ 100 μm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carbon dioxide Angiography-Guided Renal-Related Interventions in Patients with Takayasu Arteritis and Renal Insufficiency

BackgroundUse of iodinated contrast agents for angiography in patients with renal insufficiency risks further deterioration of renal function and its adverse sequelae.ObjectiveTo study the effectiveness and safety of carbon dioxide (CO{sub 2}) angiography in guiding percutaneous renal-related interventions in patients with Takayasu arteritis and renal insufficiency.MethodsData on CO{sub 2} angiography-guided interventions were obtained from a 23-year database of 692 Takayasu arteritis patients who underwent percutaneous interventions and were analyzed retrospectively. Follow-up data were also obtained. The CO{sub 2} angiography system used was developed in-house and was pressure-driven.ResultsSeven patients (6 female, age 16–59 years, baseline serum creatinine 1.62–4.55 mg/dl, estimated glomerular filtration rate 12.2–36.9 ml/min/1.73 m{sup 2}) underwent CO{sub 2} angiography-guided interventions: five underwent angioplasty or stenting to treat six stenotic/occluded renal arteries, one underwent extensive endovascular repair for spontaneous focal abdominal aortic dissection with false lumen aneurysm and aorto-iliac true lumen narrowing, and one underwent balloon dilatation of previously deployed aortic stents used to treat aortic occlusion at two levels. Follow-up (median 5 years, range 2 months–16 years) was obtained in all patients. All the procedures were successful and resulted in relief of symptoms, better blood pressure control, improvement in left ventricular systolic function and recovery or stabilization of renal function. There were no early or late complications related to CO{sub 2} angiography. Three renal lesions that had restenosis at follow-up were managed successfully by repeat intervention.ConclusionCO{sub 2} angiography-guided renal-related interventions are effective and safe in patients with Takayasu arteritis and renal insufficiency; they significantly improve the care of such patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Focal Stenting of Complex Femoropopliteal Lesions with the Multi-LOC Multiple Stent Delivery System: 12-Month Results of the Multicenter LOCOMOTIVE Study

Introduction: The purpose of this observational study is to report the 12-month clinical outcomes with the novel Multiple Stent Delivery System (MSDS) to treat complex femoropopliteal lesions. Previously, we reported the 6-month clinical outcomes of the all-comers LOCOMOTIVE study, which demonstrated the safety and efficacy of the MSDS with a favorable target lesion revascularization (TLR) rate of 5.3% and a 90.7% patency rate at 6 months in claudicants and critical limb ischemia patients. The 12-month outcomes of LOCOMOTIVE registry are presented in this report. ClinicalTrials.gov Identifier: NCT02531230. Methods: The LOCOMOTIVE study (Multi-LOC for flOw liMiting Outcomes after POBA and/or DCB Treatment in the infrainguinal position with the objecIVE to implant multiple stent segments) investigates the efficacy and safety of the MSDS approach in an all-comers population. Clinical follow-ups at 6 and 12 months are scheduled to assess TLR, ABI, and vessel patency based on sonographic imaging. Results: At 12 months, the primary unassisted patency was 85.7% and all-cause TLR rate was 9.3% in the overall cohort. Between baseline and 12 months, the target leg ABI increased from 0.62 ± 0.24 to 0.91 ± 0.38 (p < 0.001) and the mean Rutherford class improved from 3.5 to 1.9 (p < 0.001). Conclusions: Over a 12-month post-procedural period, MSDS for focal provisional stenting of complex femoropopliteal lesions demonstrated a promising primary patency and freedom from TLR after 12 months. In addition, significant improvements were observed in symptom classification and hemodynamics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Penetrating Aortic Ulcer and Intramural Hematoma

Acute aortic syndromes include a variety of overlapping clinical and anatomic diseases. Penetrating aortic ulcer (PAU), intramural hematoma (IMH) and aortic dissection can occur as isolated processes or can be found in association. All these entities are potentially life threatening, so prompt diagnosis and treatment is of paramount importance. PAU and IMH lesions in the Stanford Type A distribution often require urgent open surgical repair. Lesions in the Stanford Type B distribution may be managed medically in the absence of symptoms or progression; however, a low threshold for endovascular or surgical treatment should be maintained. This review summarizes the clinical presentation, epidemiology, diagnosis, indications for treatment and endovascular strategies in patients with PAU or IMH.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Catheter-Directed Fenestration for Branch Vessel Reconnection in Aortic Dissection Using a Novel Diamond-Tipped Chronic Total Occlusion Drilling Device: A Technical Report

Purpose: Aortic dissection is a complex condition with high morbidity and mortality. Endovascular treatments including percutaneous fenestration can be used to manage branch vessel ischaemia or risk of aortic rupture. A variety of techniques for aortic fenestration have been described. We describe the novel use of the TruePath Chronic Total Occlusion (CTO) device for aortic intimal fenestration to achieve side branch reconnection. Materials and Methods: We present three cases of aortic dissection presenting with symptoms of aortic side branch occlusion and end organ malperfusion, treated with aortic fenestration using the TruePath CTO device via trans-brachial and trans-femoral approaches. Results: Technical success was achieved in all three cases. No complications were encountered. Flow was restored in compromised visceral branches. Branches remained patent on follow-up CT angiography over a minimum 2.5-year follow-up period. Conclusion: Percutaneous aortic fenestration techniques enable a minimally invasive approach to treat visceral branch malperfusion associated with aortic dissection. The TruePath CTO device improves the control of the fenestration procedure with the potential to improve efficacy and safety.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiple Bifurcated Covered Self-Expanding Metallic Stents for Complex Tracheobronchial Fistulas or Stenosis

Objective: We aimed to determine the safety and feasibility of bifurcated covered self-expanding stents for the treatment of complex tracheobronchial fistulas or stenosis. Methods: Twenty-eight patients were treated by multiple bifurcated covered airway stents (Micro-Tech Co. Ltd., Nanjing, China), including 18 cases of gastrobronchial or gastrotracheal fistula, 6 cases of bronchopleural fistula and 4 cases of severe tracheobronchial stenosis. The large bifurcated covered stent was placed at the main carina, and the small stents were inserted into primary right carina or secondary left carina. Clinical and imaging data were retrospectively analyzed. Results: Stents were successfully inserted in 27 patients at the first attempt. In total, 29 large bifurcated covered stents, 27 small bifurcated covered stents and 5 small bifurcated covered single-plugged stents were inserted. All patients with fistula could resume eating without coughing after the procedure. No perioperative death or severe complications occurred. Two patients underwent stent removal due to intolerance of stenting; the clinical success rate was 93% (26/28). Nineteen complications were found in 12 patients; 8 patients needed stent removal or replacement, for a major complication rate of 29% (8/28). Eight patients underwent successful stent removal due to complications. Fifteen patients died of tumors and one patient died of pulmonary infection. The median survival was 33 months. Fistula recurrence was found in one patient 5 months after stenting, and second small bifurcated covered stent was inserted. Conclusions: Multiple bifurcated covered metallic stenting is effective and safe for complex tracheobronchial fistulas or stenosis, with good symptom palliation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Bronchial Embolization to Treat Intractable Bronchobiliary Fistula

Sixty-four-year-old female who underwent hemi-hepatectomy for intrahepatic cholangiocarcinoma a year ago presented with biliary sputum, cough and fever. Cross-sectional imaging showed a recurred tumor involving right diaphragmatic area and an abscess formation in liver dome with adjacent right lower lobe of lung. Percutaneous transhepatic biliary drainage and percutaneous drainage of lung abscess were performed. Tubogram showed connections between the lung abscess cavity and multiple distal bronchi, suggesting bronchobiliary fistulas. Two weeks of drainage treatment did not relieve symptoms. We successfully treated intractable bronchobiliary fistula via image-guided percutaneous access to closest distal bronchi near abscess with subsequent tandem placement of vascular plugs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stenting the Upper/Cervical Oesophagus with a Proximal Deployment Cervical Oesophageal Stent: Technique and Outcomes

Introduction: Proximal oesophageal stent deployment continues to provide challenges due to the proximity of the upper oesophageal sphincter and the associated subsequent complications such as globus sensation and stent migration. Patients with cervical oesophageal cancer have previously had limited stenting options available to them with a paucity of the literature describing the radiological technique for successfully placing these high-risk stents. In this paper, we present our experience using the Taewoong Niti-S CERVICAL Oesophageal Stent. Materials and Methods: We describe our method for stent deployment highlighting the importance of pre-procedural planning in ensuring an adequate proximal landing zone for the short proximal flare of the stent. Furthermore, we outline how we have adapted our placement technique to incorporate a routine pre-dilatation stage which has optimised retrieval of the proximal to distal deployment system. Results: We have placed eight cervical oesophageal stents within our institution. Contrast swallows in all the patients following stent deployment have demonstrated free flow of contrast to the stomach with all patients reporting symptomatic relief and no foreign body/globus sensation. There has been one episode of stent migration but no incidence of oesophageal perforation or haemorrhage. Discussion: Evolution of stenting technique and the properties of the stents themselves are improving accuracy of stent placement in relation to the important landmark of the upper oesophageal sphincter. Conclusion: Stenting of cervical oesophageal malignancy has proved successful in our institution and provided symptom relief for a subset of palliative patients who were previously unable to benefit from oesophageal stenting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interventional Treatment Strategy for Primary Budd–Chiari Syndrome with Both Inferior Vena Cava and Hepatic Vein Involvement: Patients from Two Centers in China

Objective: This retrospective study evaluated interventional treatments (recanalization, balloon dilation, and/or stent placement) for Budd–Chiari syndrome (BCS), caused by combined obstruction of the inferior vena cava (IVC) and hepatic veins (HVs). Methods: Before and after interventional therapy, patients with BCS (n = 162; asymptomatic 105.2 ± 103.3 mo; follow-up 15 [6–24] mo) underwent imaging studies (color Doppler ultrasound, CT, or MRI), and inferior vena cavography and manometry. Venous lesions were characterized by occlusion features, and presence of thrombosis and peripheral collateral vessels. Results: One, 2, and 3 main HV occlusions were observed, respectively, in 25 (15.4%), 61 (37.7%), and 76 (46.9%) patients. Eighty-three (51.2%), 98 (60.5%), and 104 (64.2%) patients had, respectively, large accessory HVs, venous collaterals formed between the HVs, or venous communicating branches between the HV and the peritoneal veins. The middle, left, and right HV was patent in 32 (19.8%), 35 (21.6%), and 44 (27.2%) patients. Recanalization of both hepatic and caval occlusions was successful in 96% (51/53) of those attempted; recanalization of IVC occlusion was successful in 97% (106/109). Among 157 patients successfully treated, 146 were cured and 11 showed clinical improvement. Clinical symptoms were relieved in 82.4% after the initial intervention, and 94.2% after the second intervention. Conclusion: Recanalization and balloon angioplasty was effective for the management of BCS with concurrent HV and IVC occlusions. The majority of patients required only IVC recanalization. The outcome of patients treated only by IVC intervention was similar to that of patients given combined HV and IVC intervention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Implications of selenium deficiency for wild herbivore conservation: a review

Selenium (Se) has been identified as an essential micronutrient in all animals. It is required at the most fundamental physiological level as a component of the selenoproteins containing the 21st amino acid, selenocysteine. Adequate levels of Se are vital to proper reproductive performance, bone metabolism, immune function and iodine metabolism. Yet, Se is a relatively rare element, and is often present at low concentrations in soil and vegetation. Selenium deficiencies are widespread in domestic stock and are unavoidable in some wildlife populations. This may be especially true for populations confined to high elevation ranges, or on areas with granitic bedrock with low Se content, or that have lost access to Se-containing parts of their ranges such as mineral licks or low-elevation winter range. The condition may be exacerbated by increased levels of oxidative stress. Because our understanding of Se as a micronutrient is relatively new, many wildlife managers are unaware of the element’s importance in physiology and population dynamics. Severe deficiency results in obvious symptoms such as white muscle disease. However, more frequently, deficiency may be chronic and subclinical. Individuals then display no obvious signs of malady, yet performance suffers until their populations decline without apparent cause. While mysterious population declines are not always due to Se deficiency, the wildlife manager should be aware of the possibility. Therefore, this review presents not only a summary of the wildlife literature regarding Se nutrition, but also a comprehensive look at the role of Se in mammalian physiology, and the behavior of this important element in the environment. Finally, the role of the biogeochemical Se cycle is discussed, and evidence is provided that the levels of available Se in the environment are decreasing while physiological demands often are increasing.

59 BASIC BIOLOGICAL SCIENCES↗

Statistical scaling of geometric characteristics in stochastically generated pore microstructures

In this study, we analyze the statistical scaling of structural attributes of virtual porous microstructures that are stochastically generated by thresholding Gaussian random fields. Characterization of the extent at which randomly generated pore spaces can be considered as representative of a particular rock sample depends on the metrics employed to compare the virtual sample against its physical counterpart. Typically, comparisons against features and/patterns of geometric observables, e.g., porosity and specific surface area, flow-related macroscopic parameters, e.g., permeability, or autocorrelation functions are used to assess the representativeness of a virtual sample, and thereby the quality of the generation method. Here, we rely on manifestations of statistical scaling of geometric observables which were recently observed in real millimeter scale rock samples [13] as additional relevant metrics by which to characterize a virtual sample. We explore the statistical scaling of two geometric observables, namely porosity (Φ) and specific surface area (SSA), of porous microstructures generated using the method of Smolarkiewicz and Winter [42] and Hyman and Winter [22]. Our results suggest that the method can produce virtual pore space samples displaying the symptoms of statistical scaling observed in real rock samples. Order q sample structure functions (statistical moments of absolute increments) of Φ and SSA scale as a power of the separation distance (lag) over a range of lags, and extended self-similarity (linear relationship between log structure functions of successive orders) appears to be an intrinsic property of the generated media. The width of the range of lags where power-law scaling is observed and the Hurst coefficient associated with the variables we consider can be controlled by the generation parameters of the method.

54 ENVIRONMENTAL SCIENCES↗

Novel gas exposure system for the controlled exposure of plants to gaseous hydrogen fluoride

Abstract Plants can serve as sensitive bioindicators of the presence of contaminant vapors in the atmosphere. This work describes a novel laboratory-based gas exposure system capable of calibrating plants as bioindicators for the detection and delineation of the atmospheric contaminant hydrogen fluoride (HF) as a preparatory step for monitoring release emissions. To evaluate changes in plant phenotype and stress-induced physiological effects attributed to HF alone, the gas exposure chamber must have additional controls to simulate otherwise optimal plant growth conditions including variables such as light intensity, photoperiod, temperature, and irrigation. The exposure system was designed to maintain constant growth conditions during a series of independent experiments that varied between optimal (control) and stressful (HF exposure) conditions. The system was also designed to ensure the safe handling and application of HF. An initial system calibration introduced HF gas into the exposure chamber and monitored HF concentrations by cavity ring-down spectroscopy for a 48-h period. Stable concentrations inside the exposure chamber were observed after approximately 15 h, and losses of HF to the system ranged from 88 to 91%. A model plant species ( Festuca arundinacea ) was then exposed to HF for 48 h. Visual phenotype stress-induced responses aligned with symptoms reported in the literature for fluoride exposure (tip dieback and discoloration along the dieback transition margin). Fluoride concentrations in exposed tissues compared to control tissues confirmed enhanced fluoride uptake due to HF exposure. The system described herein can be applied to other reactive atmospheric pollutants of interest in support of bioindicator research.

54 ENVIRONMENTAL SCIENCES↗

A fish-eye view of riverine hydropower systems. Understanding the biological response to turbine passage

One-way connectivity maintained by fish passing through hydropower turbines in fragmented rivers can be important to population dynamics, but can introduce a new and significant source of mortality due to turbine-associated mortality. Sources of mortality during downstream turbine passage can come from several sources including blade strike, shear forces, cavitation, or pressure decreases, and parsing the contributions of these individual forces is important for advancing and deploying turbines that minimize these impacts to fishes. We used a national hydropower database and conducted a systematic review of the literature to accomplish three goals: (1) report on the spatial distribution of turbine types and generation capacities in the USA, (2) determine fish mortality rates among turbine types and fish species and (3) examine relationships between physical forces similar to those encountered during fish turbine passage and fish injury and mortality. We found that while Francis turbines generate 56% of all US hydropower and have the highest associated fish mortality of any turbine type, these turbines are proportionally understudied compared to less-common and less injury-associated Kaplan turbines, particularly in the Pacific Northwest. While juvenile salmonid species in actual or simulated Kaplan turbine conditions were the most commonly studied, the highest mortality rates were reported in percid fishes passing through Francis turbines. Also, although there are several mechanisms of turbine-associated injury, barotrauma was the most commonly studied with swim bladder rupture, exopthalmia, eye gas bubbles, and prolapsed cloaca being the most serious symptoms associated with rapid pressure decreases. Future studies should focus on understanding which species are most at-risk to turbine passage mortality and, subsequently, increasing the diversity of taxonomy and turbine types in evaluations of turbine mortality.

13 HYDRO ENERGY↗

PET/CT for Diagnosis and Management of Large-Vessel Vasculitis

Purpose of Review: This review aims to discuss the use of fluorodeoxyglucose (FDG) positron emission tomography (PET/CT) for diagnosis and management of patients with large-vessel vasculitis (LVV). Recent Findings: Incidence of LVV is likely underestimated, in part due to its non-specific symptoms. Nevertheless, early diagnosis of LVV is essential to initiate timely therapy in order to prevent vascular complications, such as stenoses and aneurysms. FDG PET/CT imaging has the ability to detect LVV during the acute phase, prior to edema and other vascular structural changes, with its high sensitivity for inflammatory activity. FDG PET/CT was shown to be a powerful prognostic marker by allowing identification of patients at risk of vascular complications. Additionally, preliminary data support the use of FDG PET/CT to follow therapy efficacy. Summary: FDG PET/CT allows early detection of inflammation, before morphological and irreversible vascular changes can be observed, allowing prompt diagnosis and treatment of LVV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗