Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCREEN EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

An Innovative High Throughput Genome Releaser for Rapid and Efficient PCR Screening

High-throughput PCR screening is vital in synthetic biology and metabolic engineering as it allows researchers to rapidly analyze and detect numerous targeted genetic mutation in the genome. Current challenges for high-throughput PCR screening in synthetic biology include efficiently preparing genomic DNA, optimizing protocols for diverse sample types, managing contamination risks, and effectively analyzing the large volumes of data generated while ensuring consistent and accurate results. In this study, we present the development of a High Throughput Genome Releaser (HTGR), an innovative device addressing common challenges in screening PCR. This genome DNA releaser is designed based on a squash method for rapid, cost-effective, and efficient DNA release, optimized for subsequent PCR reactions. After experimenting with various synthetic materials, we selected a plastic that closely replicates the smooth surface and compression properties of microscope slides, ensuring reliable performance. We engineered a device featuring a 96-Well Plate and a shear applicator, operable both manually and automatically, and compatible with standard liquid-handling robot platform. This compatibility enhances ease of use in high-throughput PCR workflows. Additionally, we developed software to support its automatic functions. Our results demonstrated that the specially engineered 96-Well Plate and HTGR can effectively squash fungal spores , which release enough genome DNA for PCR screening. The genome releaser facilitates the preparation of PCR-amplifiable genomic DNA substrate from 96 samples within minutes, eliminates the need for extraction buffers, and is adaptable to a wide range of microorganisms and cells, which could significantly advance biomanufacturing processes.

Yuan, Guoliang [BATTELLE (PACIFIC NW LAB)]↗

Advanced SOFC quality control and the role of manufacturing defects on stack reliability

Atrex Energy rolled out first commercial SOFC generator products in 2013. Following that we embarked on implementation of mass production in order to ramp up productivity and lower the costs in the meantime. To ensure the goal of mass production, an accurate, cost effective and consistent quality control methodology needs to be in place. The aim of this DOE funded project is to devise a machine and methodology for cell quality control using modern non-destructive testing methods and cell rejection criterion based on the empirical determination of the role of manufacturing flaws on stack degradation and reliability. The work scope encompasses two goals aimed at 1) developing automatable techniques for objective flaw detection and 2) developing an understanding of the ramifications of flaws on stack and cell reliability. By accomplishing these two goals it is likely that an advanced stage Quality Control (QC) device can be developed. This project scope encompasses: 1) Invention of a high speed automated instrument for spatial mapping of surface and sub-surface imperfections in production cells (ex situ) using modern imaging techniques. 2) Identification of rejection criteria upon which to screen cells from production by: a. Magnification of the effect of production defects on cell degradation through fabrication and testing of micro-cells which encompass these imperfections. b. The long term testing of full size production cells both as single cells and in small stacks, in order to correlate the (in situ) performance and degradation with the imperfection type (identified ex-situ) and hence be able to classify imperfections as actual defects. We first built a defect library with the cells containing imperfections classified and documented. The cells with various imperfections were tested to evaluate the imperfection potential impact on cell electrochemical performance. Evaluations were conducted on minicell, single cell and stack levels. On minicell level, pinhole, scratch, crack, contamination, and pop-out were investigated. We found: (1) none of the imperfections causes calamity type failure, (2) pinholes do not show measurable effect on minicell performance, (3) imperfection such as electrolyte abrasion, scratch, and pop out cause minicell potential to fluctuate by different degrees; the cells with such imperfections exhibit sensitivity of potential to high fuel utilization and “self healing” behavior. On single cell level we evaluated the effect of long crack and high population pinholes. The cell with a long crack does not show performance compromise at start. There is no potential fluctuation or sensitivity to high fuel utilization or catastrophic failure. The voltage degradation due to thermal cycle is slightly higher than normal cells. The cells with high population pinholes perform surprisingly as well as normal cells over a period of 3,500h. Even when subjected to cyclic load condition, the cells 4 show negligible degradation. Our cells appear to have “self immunization” feature which fends off the adversary effects of certain imperfections. Defects were also evaluated on stack level. Two stacks were made each with ten defect cells. The first stack was tested for 13,2000h under steady load condition while the second was tested for 9,000h under transient load conditions. We found: (1) voltage fluctuation and sensitivity to thermal cycle were not observed in contrast to minicell test, (2) of the various cracks examined, including longitudinal cracks, circumferential crack, crack near closed and open ends, none exhibited distinguishable impact on performance, (3) defect cells exhibited higher degradation rates on average under steady load condition; Individually some defect cells performed similarly or better than reference cells, (4) under steady load condition all the cells degrade monotonically with degradation rate increasing with time, (5) under cyclic (transient) load condition, both defect and reference cells exhibit complex dynamic behaviors, (6) fuel loss (leak) was measured occasionally for stack 1, the cells with crack showed the highest fuel loss increase, nevertheless, no correlation with performance degradation could be established with certainty, and (7) no catastrophic failure ever happened other than incremental degradation. Posttest inspection and microanalysis were carried out; the observations are summarized in what follows: (1) Electrolyte pinholes, some scratches and IC porosity became undetectable after testing. (2) The cathode covering the popout defects is intact without any cracking or delamination. (3) The scratch was covered by cathode in pristine state; Ni oxide or NiO-YSZ filled the space where electrolyte was missing. After >10,000h operation, the cathode that used to cover the scratch was missing but the size of the scratch remains unchanged; there is a fairly dense Ni oxide layer on top of the scratch. (4) All of the cracks remain their original dimensions. Current collector kept longitudinal cracks closed which mitigated the adversary effect of crack on cell performance/durability. (5) The crack at open end showed some deterioration manifested by a small oxidation zone in the vicinity of the crack. Wide spectrum of imaging techniques were surveyed and evaluated to detect tubular SOFC defects. Optical methods, with and without assistance of expression technique, were applied to detect all kinds of defects. Thermograph method in combination of CO2 leak, ultra-sound and electric potential was also extensively evaluated to detect surface and under-surface defects such as short circuit. Based on these works, laser camera has been selected to build the final QC machine vision inspection system. The Gocator laser profile sensor was setup to generate 2D surface intensity images of tubular SOFC surface which were analyzed with Sherlock machine vision software supplied by Teledyne Dalsa. The Gocator output was integrated with the Sherlock software and enabled live images to be imported by a Common Vision Blox driver. The Sherlock software was programmed to detect various surface defects from the surface intensity images generated by the Gocator. These measurements are subsequently used to make pass or fail decisions.

01 COAL, LIGNITE, AND PEAT↗

Overview of the forthcoming AAPM TG-158 Report, 'Measurements and calculations of doses outside the treatment volume from External Beam Radiation Therapy' - Paper 85

The evolution of techniques and technology in radiotherapy has greatly improved our ability to deliver higher tumor doses while minimizing the dose to the adjacent organs at risk. However, this improved conformality has not removed the problem of doses to normal tissues outside the target volume. Whether these out-of-field doses arise from photons, electrons, protons or neutrons, there are unique challenges that many medical physicists may have limited knowledge about or experience with. With modern treatment planning systems, high dose regions and areas within the primary beam path are typically well described. However, their accuracy beyond a few centimeters outside the treatment field edge are usually poor. In these cases, alternate methods are required to assess the out-of-field dose. Such assessments require additional care to avoid potentially large errors associated with a variety of unique complications in performing dosimetry outside the treatment field. Furthermore, physicists will not always have an a priori estimate of the expected dose, and, as a result, large dosimetric errors are more easily missed. Low radiation doses outside the treatment volume are a concern because they can cause deleterious effects to the patient. The risk of late effects from the secondary radiation may be more evident today because of the success of cancer screening and modern therapies that have increased the number of cancer patients who survive and live long enough for the adverse radiation effects on healthy tissues to manifest. Simultaneously, radiotherapy procedures have become more complex, making the estimation of low out-of-field doses even more challenging. Over the past 30 years, numerous studies have been published detailing non-target doses from various radiotherapy treatments (for a detailed review see Xu et al. However, dosimetry data were obtained using a variety of measurement or computational techniques. An overview of dosimetry techniques for measuring low-level non-target doses is not available. Improved, or at least valid, dosimetry is important for several reasons. In clinical care (e.g. fetal dose estimates), large dose errors can lead to inappropriate or unnecessary treatment decisions, with potentially serious consequences to the patient. In a broader sense of somatic effects, more accurate dosimetry will improve patient risk assessment, understanding of dose responses, treatment planning, and design of the radiation delivery machines. Once reliable dosimetry data are available, it is then the clinician's responsibility to assess the risk vs. benefit of the radiotherapy treatment to make a sound and informed assessment of all possible treatment outcomes. (author)

61 RADIATION PROTECTION AND DOSIMETRY↗

Smoothed particle hydrodynamics modeling and analysis of oxide reduction process for uranium oxides

A common kinetic feature for oxide reduction chemical/electrochemical processes is oxygen transport via a porous metallic layer, which has been considered as a rate-determining step for reducing uranium oxides to metallic uranium. Accounting this kinetic behavior must involve the resolution of the moving reactive interface between shrinking oxide and expanding metal phases. This study presents a numerical model using smoothed particles hydrodynamics (SPH) to effectively deal with the evolution of the shrinking core reaction interface and oxygen transport via mass transfer of lithium oxide (Li 2 O) species in multiple mass transfer domains. We successfully validated the proposed model against a theoretical derivation for the oxide reduction process handling a shrinking oxide core with molten salt and metal ash medium on a simple planar geometry. Armed with successful validation results, the model examined a realistic reactant geometry to extend the arguments beyond the one-dimensional analyses, allowing the proposed model to apply to general application scenarios with multi-dimensional geometry. Here, this study demonstrated that the proposed model could simulate and evaluate an arbitrary reaction basket design without iterative experimental trials, which is prohibitive for a scaled high-temperature molten salt study in an inert environment. The construct potentially provides not only deep insights on multiphysics behaviors governing the process dynamics but also a robust framework for evaluating and screening candidate basket designs in the most cost-effective manner.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermophysical properties of simple liquid metals: A brief review of theory

In this paper, we review the current theory of the thermophysical properties of simple liquid metals. The emphasis is on thermodynamic properties, but we also briefly discuss the nonequilibrium properties of liquid metals. We begin by defining a 'simple liquid metal' as one in which the valence electrons interact only weakly with the ionic cores, so that the interaction can be treated by perturbation theory. We then write down the equilibrium Hamiltonian of a liquid metal as a sum of five terms: the bare ion-ion interaction, the electron-electron interaction, the bare electron-ion interaction, and the kinetic energies of electrons and ions. Since the electron-ion interaction can be treated by perturbation, the electronic part contributes in two ways to the Helmholtz free energy: it gives a density-dependent term which is independent of the arrangement of ions, and it acts to screen the ion-ion interaction, giving rise to effective ion-ion pair potentials which are density-dependent, in general. After sketching the form of a typical pair potential, we briefly enumerate some methods for calculating the ionic distribution function and hence the Helmholtz free energy of the liquid: monte Carlo simulations, molecular dynamics simulations, and thermodynamic perturbation theory. The final result is a general expression for the Helmholtz free energy of the liquid metal. It can be used to calculate a wide range of thermodynamic properties of simple metal liquids, which we enumerate. They include not only a range of thermodynamic coefficients of both metals and alloys, but also many aspects of the phase diagram, including freezing curves of pure elements and phase diagrams of liquid alloys (including liquidus and solidus curves). We briefly mention some key discoveries resulting from previous applications of this method, and point out that the same methods work for other materials not normally considered to be liquid metals (such as colloidal suspensions, in which the suspended microspheres behave like ions screened by the salt solution in which they are suspended). We conclude with a brief discussion of some non-equilibrium (i.e., transport) properties which can be treated by an extension of these methods. These include electrical resistivity, thermal conductivity, viscosity, atomic self-diffusion coefficients, concentration diffusion coefficients in alloys, surface tension and thermal emissivity. Finally, we briefly mention two methods by which the theory might be extended to non-simple liquid metals: these are empirical techniques (i.e., empirical two- and three-body potentials), and numerical many-body approaches. Both may be potentially applicable to extremely complex systems, such as nonstoichiometric liquid semiconductor alloys.

Stroud, David↗

Publisher Correction: Controlled dynamic screening of excitonic complexes in 2D semiconductors

We report a combined theoretical/experimental study of dynamic screening of excitons in media with frequency-dependent dielectric functions. We develop an analytical model showing that interparticle interactions in an exciton are screened in the range of frequencies from zero to the characteristic binding energy depending on the symmetries and transition energies of that exciton. The problem of the dynamic screening is then reduced to simply solving the Schrodinger equation with an effectively frequency-independent potential. Quantitative predictions of the model are experimentally verified using a test system: neutral, charged and defect-bound excitons in two-dimensional monolayer WS2, screened by metallic, liquid, and semiconducting environments. The screening-induced shifts of the excitonic peaks in photoluminescence spectra are in good agreement with our model.

Klots, Andrey R.↗

Engineered U7 snRNA mediates sustained splicing correction in erythroid cells from β-thalassemia/HbE patients

Highlights: • Defect of β{sup E}-globin pre-mRNA splicing was repaired by engineered splice-switching U7 snRNA. • Splice-switching oligonucleotide sequence was identified by a two-step tiling approach. • The engineered U7 snRNA improve pathology of erythroid cells from thalassemia patients. Repair of a splicing defect of β-globin pre-mRNA harboring hemoglobin E (HbE) mutation was successfully accomplished in erythroid cells from patients with β-thalassemia/HbE disorder by a synthetic splice-switching oligonucleotide (SSO). However, its application is limited by short-term effectiveness and requirement of lifelong periodic administration of SSO, especially for chronic diseases like thalassemias. Here, we engineered lentiviral vectors that stably express U7 small nuclear RNA (U7 snRNA) carrying the splice-switching sequence of the SSO that restores correct splicing of β{sup E}-globin pre-mRNA and achieves a long-term therapeutic effect. Using a two-step tiling approach, we systematically screened U7 snRNAs carrying splice-switching SSO sequences targeted to the cryptic 5′ splice site created by HbE mutation. We tested this approach and identified the most responsive element for mediating splicing correction in engineered U7 snRNAs in HeLa-β{sup E} cell model cell line. Remarkably, the U7 snRNA lentiviral vector (U7 βE4+1) targeted to this region effectively restored the correctly-spliced β{sup E}-globin mRNA for at least 5 months. Moreover, the effects of the U7 βE4+1 snRNA lentiviral vector were also evident as upregulation of the correctly-spliced β{sup E}-globin mRNA in erythroid progenitor cells from β-thalassemia/HbE patients treated with the vector, which led to improvements of pathologies in erythroid progenitor cells from thalassemia patients. These results suggest that the splicing correction of β{sup E}-globin pre-mRNA by the engineered U7 snRNA lentiviral vector provides a promising, long-term treatment for β-thalassemia/HbE.

60 APPLIED LIFE SCIENCES↗

siRNA high throughput screening identifies regulators of chloropicrin and hydrogen fluoride injury in human corneal epithelial cell models

Corneal injuries induced by various toxicants result in similar clinical presentations such as corneal opacity and neovascularization. Many studies suggest that several weeks post-exposure a convergence of the molecular mechanisms drives these progressive pathologies. However, chemical agents vary in toxicological properties, and early molecular responses are anticipated to be somewhat dissimilar for different toxicants. In this report we chose 3120 targets from the Dharmacon Human Druggable genome to screen for chloropicrin (CP) and hydrogen fluoride (HF) corneal injury as we hypothesized that targets identified in vitro may be effective as therapeutic targets in future studies. Human immortalized corneal epithelial cells (SV40-HCEC) were used for screening. Cell viability and IL-8 were analyzed to down-select hits into validation studies, where multiplex cytokine analysis and high content analysis were performed to understand toxicant effect and target function. Some endpoints were also evaluated in a second human immortalized corneal epithelial cell line, TCEpi. Over 20 targets entered validation studies for CP and HF; of these, only three targets were shared: NR3C1, RELA, and KMT5A. These findings suggest that early molecular responses to different toxicants may be somewhat distinctive and present dissimilar targets for possible early intervention.

60 APPLIED LIFE SCIENCES↗

Synergistic effects of Al, Ga, and In doping on ZnO nanorod arrays grown via citrate-assisted hydrothermal technique for highly efficient and fast scintillator screens

To be used as efficient alpha particle scintillator in the fields of nuclear security, nuclear nonproliferation and high-energy physics, scintillator screens must have high light output and fast decay properties. While there has been a great deal of progress in scintillation efficiency, achieving fast decay time properties are still a challenge. In this work, the near band edge (NBE) UV luminescence and alpha particle induced scintillation properties of vertically aligned densely packed ZnO nanorods (NRs) doped with Al, Ga, and In have been thoroughly investigated. The high crystalline hexagonal wurtzite structure with a strong orientation through the c -axis plane (002) and aspect ratios in the range 13–22 have been observed for all ZnO NRs. Electron paramagnetic resonance (EPR) analysis exhibited paramagnetic signals at g ≈ 1.96 for all ZnO NRs. A cost effective green hydrothermal synthesis technique was employed to grow well-aligned NRs. Using citrate as an additive acting as a strong reducing agent in the solution during the crystal growth, defects on the surface are significantly suppressed, thereby enhancing the NBE UV emission. Significantly higher NBE UV emission was observed from the top surface of ZnO NRs in cathodoluminescence (CL) microscopy. Results show that citrate assisted donor doping of ZnO NRs not only reduces the defect emission and NBE self-absorption, but also induces fast decay time (~ 600–700 ps), which makes ZnO NRs a good candidate for fast alpha particle scintillator screens used in associated particle imaging for time and direction tagging of individual neutrons generated in D–T and D–D neutron generators.

36 MATERIALS SCIENCE↗

Experimental Investigation of Expanded Duct Sections and Screens for Reducing FLow Distortions at Subsonic Flows

An investigation of expanded duct sections and the effect of their design parameters on flow distortion over a duct Mach number range of 0.19 to 0.67 was conducted in the small tunnel facility of the Lewis Research Center. The parameters investigated were: (1) entrance angle of expanded section, (2) length of expanded section, (3) area ratio of expanded section, (4) location of expanded section relative to the engine face, and (5) the use of screens of varying solidities and mesh. Expansion half-angles of deg, 15 deg, and 30 deg reduced the total-pressure distortions induced in the duct. The larger expansion angles reduced circumferential distortion more effectively than radial distortion. However, the half-angle of 15 deg appeared to be optimum for reducing both radial and circumferential distortions while still maintaining a high total-pressure recovery. Increasing the expanded-section area ratio and increasing the expanded-section lengths with-the 150 expansion half-angle led to less total-pressure distortion with no appreciable loss in pressure recovery. Screens incorporated in the expanded section indicated that 22.2-percent- solidity screens decreased distortion still further.while 37.3-percent- solidity screens generally increased distortion above that of a constant- area duct incorporating the same solidity screen.

Chiccine, Bruce G.↗

Novel curcumin analogue 14p protects against myocardial ischemia reperfusion injury through Nrf2-activating anti-oxidative activity

Background: Alleviating the oxidant stress associated with myocardial ischemia reperfusion has been demonstrated as a potential therapeutic approach to limit ischemia reperfusion (I/R)-induced cardiac damage. Curcumin, a natural compound with anti-oxidative activity, exerts beneficial effect against cardiac I/R injury, but poor chemical and metabolic stability. Previously, we have designed and synthesized a series of mono-carbonyl analogues of curcumin (MACs) with high stability. This study aims to find new anti-oxidant MACs and to demonstrate their effects and mechanisms against I/R-induced heart injury. Methods: H9c2 cells challenged with H{sub 2}O{sub 2} or TBHP were used for in vitro bio-screening and mechanistic studies. The MDA, H{sub 2}O{sub 2} and SOD levels in H9C2 cells were determined, and the cell viability was assessed by MTT assay. Myocardial I/R mouse models administrated with or without the compound were used for in vivo studies. Results: The in vitro cell-based screening showed that curcumin analogues 8d and 14p exhibited strong anti-oxidative effects. Pre-treatment of H9c2 cells with 14p activated Nrf2 signaling pathway, attenuated H{sub 2}O{sub 2}-increased MDA and SOD level, followed by the inhibition of TBHP-induced cell death and Bax/Bcl-2–caspase-3 pathway activation. Silencing Nrf2 significantly reversed the protective effects of 14p. In in vivo animal model of myocardial I/R, administration of low dose 14p (10 mg/kg) reduced infarct size and myocardial apoptosis to the same extent as the high dose curcumin (100 mg/kg). Conclusion: These data support the novel curcumin analogue 14p as a promising antioxidant to decrease oxidative stress and limit myocardial ischemia reperfusion injury via activating Nrf2. - Highlights: • Mono-carbonyl analogue of curcumin, 14p, exhibited better chemical stability. • Compound 14p inhibited TBHP-induced apoptosis through activating Nrf2 in vitro. • Compound 14p limited myocardial ischemia/reperfusion (I/R) injury in vivo. • Compound 14p functioned through both antioxidant and anti-apoptotic pathways. • Compound 14p limited myocardial I/R injury as a promising antioxidant.

60 APPLIED LIFE SCIENCES↗

Effect of facility background gases on internal erosion of the 30-cm Hg ion thruster

One life limiting phenomenon of mercury bombardment thrusters is sputtering erosion of the upstream side of the molybdenum screen grid by discharge chamber ions. Data were obtained which revealed that the screen grid erosion was very sensitive to the partial pressure of certain background gases in the space simulation vacuum facility. The results of tests conducted to evaluate this effect are presented. An estimate of the screen grid erosion in space was made which showed that adequate lifetime for proposed missions exists.

Rawlin, V. K.↗

Screening and Qualification of BME Feedthrough Capacitors for a Space Project

Surface mount technology feedthrough ceramic capacitors are gaining popularity in Hi-Rel systems due to small size and great filtering characteristics. In this work, BME feedthrough capacitors compliant with AEC-Q200 requirements have been evaluated, screened and qualified for a space project. Evaluation included analysis of the effect of post-soldering thermal shocks, temperature dependencies of leakage currents, distribution of breakdown voltages, assessments of high-current capability, and thermal resistance of the parts. The parts have been screened and qualified at conditions close to the military requirements for ceramic capacitors. No failures were detected during screening including burning-in, but two samples failed during monitored 2000 hour life testing at 125C and two times rated voltage. Failure analysis revealed manufacturing defects that required additional analysis of screening and qualification test conditions. Highly accelerated life testing (HALT) has been carried out to assess reliability acceleration factors and the probability of failure at the use conditions. An approach to selection of adequate burning-in and life test conditions is discussed.

Alexander Teverovsky↗

Screening and Qualification of BME Feedthrough Capacitors for a Space Project

Surface mount technology feedthrough ceramic capacitors are gaining popularity in Hi-Rel systems due to small size and great filtering characteristics. In this work, BME feedthrough capacitors compliant with AEC-Q200 requirements have been evaluated, screened and qualified for a space project. Evaluation included analysis of the effect of post-soldering thermal shocks, temperature dependencies of leakage currents, distribution of breakdown voltages, assessments of high-current capability, and thermal resistance of the parts. The parts have been screened and qualified at conditions close to the military requirements for ceramic capacitors. No failures were detected during screening including burning-in, but two samples failed during monitored 2000 hour life testing at 125C and two times rated voltage. Failure analysis revealed manufacturing defects that required additional analysis of screening and qualification test conditions. Highly accelerated life testing (HALT) has been carried out to assess reliability acceleration factors and the probability of failure at the use conditions. An approach to selection of adequate burning-in and life test conditions is discussed.

Alexander Teverovsky↗

A Screening Method Using Pulsed-Power Combined with Infrared Imaging to Detect Pattern Defects in Bulk Metal Foil or Thin Film Resistors

Bulk metal foil and thin film resistors occasionally contain localized defects within the etched resistor pattern. Common defects of this type include in-line constrictions referred to as notches, unremoved resistor material bridges between adjacent pattern lines, and embedded non-conductive particles in the resistor material. Such defects are prone to fracture due to thermomechanical fatigue during powered operation, especially power cycling, resulting in positive resistance change and open circuit failure modes. Common screening methods of optical microscopy, short time overload power tests (e.g., 6.25x rated power for 5 seconds) and burn-in (e.g., 1.5x rated power for 100 hours) are useful, but they are not always effective at removing devices with such defects. An improved method has been developed to screen for localized resistor pattern defects. The method involves the application of brief, high power electrical pulses at a low duty cycle while inspecting the resistor with a high resolution, high speed infrared camera. The following test conditions were found to be suitable for this purpose: 6.25x rated power, 1 to 5 pulses, 50 ms pulse width and 10% duty cycle. During the power pulsing, localized constrictions in the resistor pattern are identifiable as hot spots via the infrared camera. Reject criteria can be established based on observations of hot spots. To assess its effectiveness, a total of two hundred eighty (280) surface mount foil resistors (40 each from 7 different lots) were screened using this infrared technique. The screening identified twenty-nine (29) resistors with significant hot spots in the resistor pattern. All 280 resistors were then subjected to an industry standard 10,000 hour life test at 1x rated power at 70°C with power cycled for 90 minutes on and 30 minutes off. During life testing, three resistors exhibited positive resistance change failure mode. All three failures were due to thermomechanical fatigue failure of localized bridge defects at the locations identified via infrared screening. The results of this evaluation illustrate the benefits of the pulsed-power infrared detection screening technique to identify reliability suspect foil or thin film resistors that may escape common screening methods.

screening↗

A Screening Method Using Pulsed-Power Combined with Infrared Imaging to Detect Pattern Defects in Bulk Metal Foil or Thin Film Resistors

Bulk metal foil and thin film resistors occasionally contain localized defects within the etched resistor pattern. Common defects of this type include in-line constrictions referred to as notches, unremoved resistor material bridges between adjacent pattern lines, and embedded non-conductive particles in the resistor material. Such defects are prone to fracture due to thermomechanical fatigue during powered operation, especially power cycling, resulting in positive resistance change and open circuit failure modes. Common screening methods of optical microscopy, short time overload power tests (e.g., 6.25x rated power for 5 seconds) and burn-in (e.g., 1.5x rated power for 100 hours) are useful, but they are not always effective at removing devices with such defects. An improved method has been developed to screen for localized resistor pattern defects. The method involves the application of brief, high power electrical pulses at a low duty cycle while inspecting the resistor with a high resolution, high speed infrared camera. The following test conditions were found to be suitable for this purpose: 6.25x rated power, 1 to 5 pulses, 50 ms pulse width and 10% duty cycle. During the power pulsing, localized constrictions in the resistor pattern are identifiable as hot spots via the infrared camera. Reject criteria can be established based on observations of hot spots. To assess its effectiveness, a total of two hundred eighty (280) surface mount foil resistors (40 each from 7 different lots) were screened using this infrared technique. The screening identified twenty-nine (29) resistors with significant hot spots in the resistor pattern. All 280 resistors were then subjected to an industry standard 10,000 hour life test at 1x rated power at 70°C with power cycled for 90 minutes on and 30 minutes off. During life testing, three resistors exhibited positive resistance change failure mode. All three failures were due to thermomechanical fatigue failure of localized bridge defects at the locations identified via infrared screening. The results of this evaluation illustrate the benefits of the pulsed-power infrared detection screening technique to identify reliability suspect foil or thin film resistors that may escape common screening methods.

screening↗

Magnetic Proximity Effects in Transition-Metal Dichalcogenides: Converting Excitons

The two-dimensional character and reduced screening in monolayer transition-metal dichalcogenides (TMDs) lead to the ubiquitous formation of robust excitons with binding energies orders of magnitude larger than in bulk semiconductors. Focusing on neutral excitons, bound electron-hole pairs that dominate the optical response in TMDs, it is shown that they can provide fingerprints for magnetic proximity effects in magnetic heterostructures. These proximity effects cannot be described by the widely used single-particle description but instead reveal the possibility of a conversion between optically inactive and active excitons by rotating the magnetization of the magnetic substrate. With recent breakthroughs in fabricating Mo- and W-based magnetic TMD heterostructures, this emergent optical response can be directly tested experimentally.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Materials for the General Aviation Industry: Effect of Environment on Mechanical Properties of Glass Fabric/Rubber Toughened Vinyl Ester Laminates

A screening evaluation is being conducted to determine the performance of several glass fabric/vinyl ester composite material systems for use in primary General Aviation aircraft structures. In efforts to revitalize the General Aviation industry, the Integrated Design and Manufacturing Work Package for General Aviation Airframe and Propeller Structures is seeking to develop novel composite materials and low-cost manufacturing methods for lighter, safer and more affordable small aircraft. In support of this Work Package, this study is generating material properties for several glass fabric/rubber toughened vinyl ester composite systems and investigates the effect of environment on property retention. All laminates are made using the Seemann Composites Resin Infusion Molding Process (SCRIMP), a potential manufacturing method for the General Aviation industry.

McBride, Timothy M.↗