Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

ATLAS DBM Module Qualification

This is a technical scope of work (TSW) between the Fermi National Accelerator Laboratory (Fermilab) and the experimenters of Jozef Stefan Institute, CERN, and University of Toronto who have committed to participate in beam tests to be carried out during the 2014 Fermilab Test Beam Facility program. Chemical Vapour Deposition (CVD) diamond has a number of properties that make it attractive for high energy physics detector applications. Its large band-gap (5.5 eV) and large displacement energy (42 eV/atom) make it a material that is inherently radiation tolerant with very low leakage currents and high thermal conductivity. CVD diamond is being investigated by the RD42 Collaboration for use very close to LHC interaction regions, where the most extreme radiation conditions are found. This document builds on that work and proposes a highly spatially segmented diamond-based luminosity monitor to complement the time-segmented ATLAS Beam Conditions Monitor (BCM) so that, when Minimum Bias Trigger Scintillators (MTBS) and LUCID (LUminosity measurement using a Cherenkov Integrating Detector) have difficulty functioning, the ATLAS luminosity measurement is not compromised.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alkali Halide Microstructured Optical Fiber for X-Ray Detection

Microstructured optical fibers containing alkali halide scintillation materials of CsI(Na), CsI(Tl), and NaI(Tl) are presented. The scintillation materials are grown inside the microstructured fibers using a modified Bridgman-Stockbarger technique. The x-ray photon counts of these fibers, with and without an aluminum film coating are compared to the output of a collimated CdTe solid state detector over an energy range from 10 to 40 keV. The photon count results show significant variations in the fiber output based on the materials. The alkali halide fiber output can exceed that of the CdTe detector, dependent upon photon counter efficiency and fiber configuration. The results and associated materials difference are discussed.

DeHaven, S. L.↗

The Search for High-Energy Photons and Neutrinos Producing Extensive Air Showers with Energies E > 10{sup 18} eV and Zenith Angles θ > 70{sup °} in the Yakutsk Array Data

The method of searching for showers generated by neutral particles such as high-energy gamma quanta and astrophysical neutrinos is described, and the results of this search are presented. These results were obtained in the combined analysis of data on electrons, muons, and Cherenkov radiation of EASs and their temporal responses in scintillation and Cherenkov detectors. An upper limit on the flux of gamma quanta with energies of 3 × 10{sup 1}8, 10{sup 1}9, and 3 × 10{sup 1}9 eV was obtained. The multiparameter analysis of shower characteristics did not reveal EASs produced by neutrinos.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of MICE

Muon ionization cooling is the only practical method for preparing high-brilliance beams needed for a neutrino factory or muon collider. The muon ionization cooling experiment (MICE) under development at the Rutherford Appleton Laboratory comprises a dedicated beamline to generate a range of input emittance and momentum, with time-of-flight and Cherenkov detectors to ensure a pure muon beam. A first measurement of emittance is performed in the upstream magnetic spectrometer with a scintillating-fiber tracker. A cooling cell will then follow, alternating energy loss in liquid hydrogen with RF acceleration. A second spectrometer identical to the first and a particle identification system will measure the outgoing emittance. Plans for measurements of emittance and cooling are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Critical Configuration and Physics Measurements for Beryllium Reflected Assemblies of U(93.15)O 2 Fuel Rods (1.506-cm Pitch)

Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one NaI scintillator and the other foil on the other NaI detector and the activities measured simultaneously. The activation of a particular foil was compared to that of the normalization foil by dividing the count rate for each foil by that of the normalization foil. To correct for the differing efficiencies of the two NaI detectors, the normalization foil was counted in Detector 1 simultaneously with the foil at position x in Detector 2, and then the normalization foil was counted simultaneously in Detector 2 with the foil from position x in Counter 1. The activity of the foil from position x was divided by the activity of the normalization foil counted simultaneously. This resulted in obtaining two values of the ratio that were then averaged. This procedure essentially removed the effect of the differing efficiencies of the two NaI detectors. Differing efficiencies of 10% resulted in errors in the ratios measured to less than 1%. The background counting rates obatined with the foils used for the measurements on the NaI detectors before their irradiation measurement were subtracted from all count rates. The results of the cadmium ratio measurements are given in Table 1.3-1 and Figure 1.3-1. “No correction has been made for self shielding in the foils” (Reference 3).

1.506-cm pitch↗

Critical Configuration and Physics Measurements for Beryllium Reflected Assemblies of U(93.15)O 2 Fuel Rods (1.506-cm Pitch and 7-Tube Clusters)

Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one NaI scintillator and the other foil on the other NaI detector and the activities measured simultaneously. The activation of a particular foil was compared to that of the normalization foil by dividing the count rate for each foil by that of the normalization foil. To correct for the differing efficiencies of the two NaI detectors, the normalization foil was counted in Detector 1 simultaneously with the foil at position x in Detector 2, and then the normalization foil was counted simultaneously in Detector 2 with the foil from position x in Counter 1. The activity of the foil from position x was divided by the activity of the normalization foil counted simultaneously. This resulted in obtaining two values of the ratio that were then averaged. This procedure essentially removed the effect of the differing efficiencies of the two NaI detectors. Differing efficiencies of 10% resulted in errors in the ratios measured to less than 1%. The background counting rates obatined with the foils used for the measurements on the NaI detectors before their irradiation measurement were subtracted from all count rates. The results of the cadmium ratio measurements are given in Table 1.3-1 and Figure 1.3-1. “No correction has been made for self shielding in the foils” (Reference 3).

reactivity worth measurements↗

Critical Configuration and Physics Measurements for Beryllium Reflected Assemblies of U(93.15) O₂ Fuel Rods (1.506-cm Pitch and 7-Tube Clusters) (Rev. 2)

Cadmium ratios were measured with enriched uranium metal foils at various locations in the assembly with the fuel tube at the 1.506-cm spacing. They are described in the following subsections. The experiment configuration was the same as the first critical configuration described in HEU-COMP-FAST-004 (Case 1). The experimenter placed 0.75-cm-diameter × 0.010-cm-thick 93.15%-235U-enriched uranium metal foils with and without 0.051-cm-thick cadmium covers at various locations in the core and top reflector. One part of the cadmium cover was cupshape and contained the uranium foil. The other part was a lid that fit over the exposed side of the foil when it was in the cup shaped section of the cover. As can be seen in the logbook, two runs were required to obtain all the measurements necessary for the cadmium ratio. The bare foil measurements within the top reflector were run first as part of the axial foil activation measurements. The results of this run are used for both the axial activation results and the cadmium ratios. Cadmium covered foils were then placed at the same location through the top reflector in a different run. Three pairs of bare and cadmium covered foils were also placed through the core tank. One pair was placed at the axial center of a fuel tube 11.35 cm from the center of the core. Two pairs of foils were placed on top of fuel tubes 3.02 and 12.06 cm from the center of the core. The activation of the uranium metal foils was measured after removal from the assembly using two lead shielded NaI scintillation detectors as follows. The NaI scintillators were carefully matched and had detection efficiencies for counting delayed-fission-product gamma rays with energies above 250 KeV within 5%. In all foil activation measurements, one foil at a specific location was used as a normalizing foil to remove the effects of the decay of fission products during the counting measurements with the NaI detectors. The normalization foil was placed on one NaI scintillator and the other foil on the other NaI detector and the activities measured simultaneously. The activation of a particular foil was compared to that of the normalization foil by dividing the count rate for each foil by that of the normalization foil. To correct for the differing efficiencies of the two NaI detectors, the normalization foil was counted in Detector 1 simultaneously with the foil at position x in Detector 2, and then the normalization foil was counted simultaneously in Detector 2 with the foil from position x in Counter 1. The activity of the foil from position x was divided by the activity of the normalization foil counted simultaneously. This resulted in obtaining two values of the ratio that were then averaged. This procedure essentially removed the effect of the differing efficiencies of the two NaI detectors. Differing efficiencies of 10% resulted in errors in the ratios measured to less than 1%. The background counting rates obatined with the foils used for the measurements on the NaI detectors before their irradiation measurement were subtracted from all count rates. The results of the cadmium ratio measurements are given in Table 1.3-1 and Figure 1.3-1. “No correction has been made for self shielding in the foils” (Reference 3).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Plutonium measurements with a fast-neutron multiplicity counter for nuclear safeguards applications

Measurements were performed at the Joint Research Centre in Ispra, Italy to field test a fast-neutron multiplicity counter developed at the University of Michigan. The measurements allowed the assessment of the system's photon discrimination abilities, efficiency when measuring neutron multiplicity, ability to characterize 240 Pu eff mass, and performance relative to a currently deployed neutron coincidence counter. We describe how this work is motivated by the need to replace and improve upon 3 He neutron detection systems for nuclear safeguards applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The development of a 6 Li-based pixelated neutron detector for neutron reflectometry at the Spallation Neutron Source

We present a high-rate 6 Li-based pixelated neutron detector developed for neutron reflectometry instruments at the Spallation Neutron Source (SNS). The neutron detector has a pixelated design: each 6 Li scintillator element has its own photosensor and independent channel readout. This paper focuses on the general overview of the detector design and construction, the characterization of the pixelated detector, and the results of the first neutron reflectivity experiments conducted using the pixelated neutron detector at the SNS Liquid Reflectometer (BL-4B). The pixelated neutron detector demonstrated a global time-average count rate of ≥ 1.8 x 10 6 cps, at least 3 orders of magnitude higher than that of the existing neutron detector ( 3 He-based Multi-Wire Proportional Counter), and a local instantaneous count rate of ≥ 1.73 x 10 6 cps / cm 2 . The maximum counting rate of the detector has not yet been determined as the detector is capable of handling the maximum flux available at the beamline. Furthermore, the outcome of the neutron reflectivity experiments showed that the pixelated neutron detector is a promising candidate for next-generation neutron reflectometry instruments at the SNS.

6Li, silicon photomultiplier↗

Statistical estimation of the performance of a fast-neutron multiplicity system for nuclear material accountancy

Statistical analyses have been performed to develop bounding estimates of the expected performance of a conceptual fast-neutron multiplicity system (FNMS) for assaying plutonium. The conceptual FNMS design includes 32 cubic liquid scintillator detectors, measuring 7.62 cm per side, configured into 4 stacked rings of 8 detectors each. Expected response characteristics for the individual FNMS detectors, as well as the response characteristics of the entire FNMS, were determined using Monte Carlo simulations based on prior validation experiments. The results from these simulations were then used to estimate the Pu assay capabilities of the FNMS in terms of counting time, assay mass, and assay mass variance, using assay mass variance as a figure of merit. The analysis results are compared against a commonly used thermal-neutron coincidence counter. The advantages of using a fast-neutron counting system versus a thermal-neutron counting system are significant. Most notably, the time required to perform an assay to an equivalent assay mass variance is greatly reduced with a fast-neutron system, by more than an order of magnitude compared with that of the thermal-neutron system, due to the reduced probability of random summing with the fast system. The improved FNMS performance is especially relevant for assays involving Pu masses of 10 g or more.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo Shower Counter Studies

Activities and accomplishments related to the Monte Carlo shower counter studies are summarized. A tape of the VMS version of the GEANT software was obtained and installed on the central computer at Gallaudet University. Due to difficulties encountered in updating this VMS version, a decision was made to switch to the UNIX version of the package. This version was installed and used to generate the set of data files currently accessed by various analysis programs. The GEANT software was used to write files of data for positron and proton showers. Showers were simulated for a detector consisting of 50 alternating layers of lead and scintillator. Each file consisted of 1000 events at each of the following energies: 0.1, 0.5, 2.0, 10, 44, and 200 GeV. Data analysis activities related to clustering, chi square, and likelihood analyses are summarized. Source code for the GEANT user subprograms and data analysis programs are provided along with example data plots.

Snyder, H. David↗

MO-FG-303-05: A Feasibility Study of Using a Cherenkov Detector Material with the Prompt Gamma Range Verification Technique in Proton Therapy

Purpose: To simulate the feasibility of a Cherenkov glass material for the determination of the penetration depth of therapeutic proton beams in water. Methods: Proton pencil beams of various energies incident onto a water phantom with dimensions of 5 x 5 x 30 cm{sup 3} were used for simulation with the Geant4 toolkit. The model used standard electromagnetic packages, packages based on binary-cascade nuclear model, several decay modules (G4Decay, G4DecayPhysics, and G4RadioactiveDecayPhysics), and optical photon components (G4OpticalPhysics). A Cherenkov glass material was modeled as the detector medium (7.2 g of In2O3 + 90 g cladding, density of 2.82 g/cm{sup 3}, Zeff = 33.7, index of refraction n(600 nm) = 1.56, and energy threshold of production Eth = 156 keV ). The emitted secondary particles are analyzed characterizing their timing, energy, and angular distributions. A feasibility analysis was conducted for a simplistic detector system using this material to locate the position of the Bragg Peak. Results: The escaping neutrons have energies ranging from thermal to the incident proton energy and the escaping photons have energies >10 MeV. Photon peaks between 4 and 6 MeV were attributed to originate from direct proton interactions with {sup 12}C (∼ 4.4 MeV) and {sup 16}O (∼ 6 MeV), respectively. The escaping photons are emitted isotropically, while low (≤10 MeV) and high (>10 MeV) neutrons are isotropic and forward-directional, respectively. The emissions of photons are categorized into prompt (∼ns) and delayed (∼min) where the prompt photons include the 4.4 and 6 MeV. The Cherenkov material had on average <2% of neutron interactions while LYSO and BGO scintillators had a minimum of ∼50%. Our simplistic detector system was capable of discerning Bragg Peak locations using a timing discrimination of ∼50 ns. Conclusion: We investigate the viability of using the Cherenkov material for MeV photon detection medium for the prompt gamma technique.

60 APPLIED LIFE SCIENCES↗

New developments in the diagnostics for the fusion products on JET in preparation for ITER (invited)

Notwithstanding the advances of the past decades, significant developments are still needed to satisfactorily diagnose ''burning plasmas.'' D-T plasmas indeed require a series of additional measurements for the optimization and control of the configuration: the 14 MeV neutrons, the isotopic composition of the main plasma, the helium ash, and the redistribution and losses of the alpha particles. Moreover a burning plasma environment is in general much more hostile for diagnostics than purely deuterium plasmas. Therefore, in addition to the development and refinement of new measuring techniques, technological advances are also indispensable for the proper characterization of the next generation of devices. On JET an integrated program of diagnostic developments, for JET future and in preparation for ITER, has been pursued and many new results are now available. In the field of neutron detection, the neutron spectra are now routinely measured in the energy range of 1-18 MeV by a time of flight spectrometer and they have allowed studying the effects of rf heating on the fast ions.A new analysis method for the interpretation of the neutron cameras measurements has been refined and applied to the data of the last trace tritium campaign (TTE). With regard to technological upgrades, chemical vapor deposition diamond detectors have been qualified both as neutron counters and as neutron spectrometers, with a potential energy resolution of about one percent. The in situ calibration of the neutron diagnostics, in preparation for the operation with the ITER-like wall, is also promoting important technological developments. With regard to the fast particles, for the first time the temperature of the fast particle tails has been obtained with a new high purity Germanium detector measuring the gamma emission spectrum from the plasma. The effects of toroidal Alfven eigenmodes modes and various MHD instabilities on the confinement of the fast particles have been determined with a combination of gamma ray cameras, neutral particle analyzers, scintillator probe, and Faraday cups. From a more technological perspective, various neutron filters have been tested to allow measurement of the gamma ray emission also at high level of neutron yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytical expressions for the gate utilization factors of passive multiplicity counters including signal build-up

In the realm of nuclear safeguards, passive neutron multiplicity counting using shift register pulse train analysis to nondestructively quantify Pu in product materials is a familiar and widely applied technique. The approach most commonly taken is to construct a neutron detector consisting of {sup 3}He filled cylindrical proportional counters embedded in a high density polyethylene moderator. Fast neutrons from the item enter the moderator and are quickly slowed down, on timescales of the order of 1-2 {micro}s, creating a thermal population which then persists typically for several 10's {micro}s and is sampled by the {sup 3}He detectors. Because the initial transient is of comparatively short duration it has been traditional to treat it as instantaneous and furthermore to approximate the subsequent capture time distribution as exponential in shape. With these approximations simple expressions for the various Gate Utilization Factors (GUFs) can be obtained. These factors represent the proportion of time correlated events i.e. Doubles and Triples signal present in the pulse train that is detected by the coincidence gate structure chosen (predelay and gate width settings of the multiplicity shift register). More complicated expressions can be derived by generalizing the capture time distribution to multiple time components or harmonics typically present in real systems. When it comes to applying passive neutron multiplicity methods to extremely intense (i.e. high emission rate and highly multiplying) neutron sources there is a drive to use detector types with very fast response characteristics in order to cope with the high rates. In addition to short pulse width, detectors with a short capture time profile are also desirable so that a short coincidence gate width can be set in order to reduce the chance or Accidental coincidence signal. In extreme cases, such as might be realized using boron loaded scintillators, the dieaway time may be so short that the build-up (thermalization transient) within the detector cannot be ignored. Another example where signal build-up might be observed is when a {sup 3}He based system is used to track the evolution of the time correlated signal created by a higher multiplying item within a reflective configuration such as the measurement of a spent fuel assembly. In this work we develop expressions for the GUFs which include signal build-up.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design and development of Gamma-ray Burst Monitor for the CALET Mission

We propose to provide a gamma-ray burst monitor (GBM) for the CALET mission to monitor gamma-ray bursts (GRBs) together with the CALET Imaging Calorimeter detector. The major purpose is to derive a wide-band energy spectrum of GRBs over an unprecedented 9 decades of energy (from a few keV to a few TeV) in combination with the CALET tower detector. Hence it is desirable to have the CALET-GBM covering an energy range from a few keV to about 20 MeV to avoid a gap in the observational energy bands. The design of GBM is underway to fulfill this requirement. The current detector candidate is BGO, and a LaBr (Ce) scintillator which has a superior energy resolution to that of NaI(Tl). In this paper, design and expected performance of the CALET-GBM is shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parallel-Plate Avalanche Counter (PPAC) Fabrication for 240 Pu PFNS Measurement [Slides]

A LANL-LLNL joint program has been developed successfully to measure PFNS and established the most precisely determined $\chi$ matrices for 235,238 U and 239 Pu. It has been extended to 240 Pu now and possibly to 233 U in the future. An alternative method was developed to fabricate 240 Pu and a total of 12 targets were made with a total mass of 17.9 mg. The PFNS measurement for 240 Pu will begin in June, 2022 when the new beam cycle starts and the data analysis follows immediately afterward.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of wide-band X-ray/gamma-ray imagers using reach through APD arrays

It is quite important to obtain wide band spectra of gamma-ray bursts (GRBs) at the same time in order to probe the emission processes or the structure of GRBs. An avalanche photo diode (APD) is a compact photon sensor with an internal gain of 100. We have developed an X-ray/gamma-ray detector using a back-illuminated reach-through APD (5x5 mm{sup 2}) optically coupled with a conventional CsI(Tl) scintillator, which covers typically from 1 keV to 1 MeV. Further, we developed a 1-dimensional array of the 8/16 APDs (net 16x20 mm{sup 2}) for the purpose of an imaging photon detector to be used in future GRB missions. Here we present the current status and performance of our hybrid detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observations of a large flare in GX 1+4 with the Compton gamma ray observatory

The pulsating X-ray binary GX 1+4 (4U 1728-24) was observed by Oriented Scintillation Spectrometer Experiment (OSSE) onboard the Compton Gamma Ray Observatory (CGRO) from 9 to 21 September 1993 as a target of oppurtunity after Burst and Transient Source Experiment (BATSE) had detected the onset of a large flare by the greatly increased pulsed flux at the period of approximately 2 min. The total flux in the 40-100 keV range as observed by the OSSE reached its maximum of 83 mCrab on 14/15 September, after which it fell sharply to about 31 mCrab within 2 days. The spectrum is well described by thermal type spectra. The characteristic temperature of the average OSSE spectrum for a thermal Bremsstrahlung model is kT = (35.5 +/- 0.5) keV. A single power law can be ruled out. There is evidence for a hardening of the spectrum with decreasing intensity at the end of the flare. The barycentric pulse period was (120.567 +/- 0.005) s on 5 September. The average spin-down rate as taken from the standard BATSE analysis was dP/dt = 0.0105 s/day, and constant over the time of the flare. A further target of oppurtunity (TOO) observation with the ROSAT Position Sensitive Proportional Counter (PSPC) on 18 September led to the first detection of the source with a reflecting X-ray telescope and to a signifcantly improved position: RA(2000) = 17h 32m 2.1s and DEC(2000) = -24 deg 44 min 44 sec. This position 3.5 sec from V2116 Oph, with a 90% error radius of 8 sec is the most accurate so far obtained with an X-ray instrument, thus confirming the identification with the suspected stellar counterpart.

Staubert, R.↗