Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCAN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Design and validation of a gamma-ray scanning system for measuring irradiated nuclear fuel

We report a prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Study of Scanning Micro-arc Oxidation and Coating Development

Micro-arc oxidation (MAO) continues to be the focus of numerous investigations, whereas relatively few studies have considered scanning micro-arc oxidation (SMAO). In the present work, an experimental study was performed using stationary and moving electrodes to investigate coating development in SMAO and discern the effect of key process parameters. Examination of oxide deposits made on A356 aluminum show that coating thickness and growth rate are inversely related to inter-electrode spacing and travel speed. An evaluation of SMAO deposits made by stationary and moving nozzles revealed that coating thickness profiles follow a Gaussian distribution due to the electrolyte flow field in the impingement zone. Hardness surveys and scanning electron microscope analysis of SMAO coatings revealed that micro-hardness distributions and cross-sectional morphology are similar to MAO for a stationary nozzle but that a denser outer layer develops when a moving nozzle is used. This is attributed to a high density of discharge occurring in micropores of the oxide film and remelting which results from the moving electrolyte column. Analysis of voltage–current characteristic curves shows that the resistance of the electrolyte column is essentially linear over the range considered and results indicate that it can be modeled as a variable length resistor. While further testing is needed, results confirm that SMAO is suitable for coating large, planar parts and for repairing worn surfaces.

36 MATERIALS SCIENCE↗

Microstructures and Microhardness Properties of CMSX-4{sup ®} Additively Fabricated Through Scanning Laser Epitaxy (SLE)

Epitaxial CMSX-4{sup ®} deposition is achieved on CMSX-4{sup ®} substrates through the scanning laser epitaxy (SLE) process. A thorough analysis is performed using various advanced material characterization techniques, namely high-resolution optical microscopy, scanning electron microscopy, energy-dispersive x-ray spectroscopy, x-ray diffraction, and Vickers microhardness measurements, to characterize and compare the quality of the SLE-fabricated CMSX-4{sup ®} deposits to the CMSX-4{sup ®} substrates. The results show that the CMSX-4{sup ®} deposits have smaller primary dendritic arm spacing, finer γ/γ′ size, weaker elemental segregation, and higher microhardness compared to the investment cast CMSX-4{sup ®} substrates. The results presented here demonstrate that CMSX-4{sup ®} is an attractive material for laser-based AM processing and, therefore, can be used in the fabrication of gas turbine hot-section components through AM processing.

36 MATERIALS SCIENCE↗

Texture evolution as a function of scan strategy and build height in electron beam melted Ti-6Al-4V

Metal additive manufacturing (AM) enables customizable, on-demand parts, allowing for new designs and improved engineering performance. Yet, the ability to control AM metal alloy microstructures (i.e., grain morphology, crystallographic texture, and phase content) is lacking. Furthermore, this work performs corroborative neutron diffraction and large-scale electron backscatter diffraction (EBSD) measurements to assess crystallographic texture in electron beam melted (EBM) Ti-6Al-4V as a function of scan strategy and build height. Texture components for one raster and two spot melt scan strategies were evaluated using a triclinic specimen symmetry to capture all possible texture components, which were found to be considerably different than previously reported values from studies employing orthotropic specimen symmetry. This finding highlights the importance of a standard method and best practice for assessing textures produced by AM.

36 MATERIALS SCIENCE↗

Characterization of morphology and hydration products of high-volume fly ash paste by monochromatic scanning x-ray micro-diffraction (μ-SXRD)

The present study focuses on identification and micro-structural characterization of the hydration products formed in high-volume fly ash (HVFA)/portland cement (PC) systems using monochromatic scanning x-ray micro-diffraction (μ-SXRD) and SEM-EDS. Pastes with up to 80% fly ash replacement were studied. Phase maps for HVFA samples using μ-SXRD patterns prove that μ-SXRD is an effective method to identify and visualize the distribution of phases in the matrix. μ-SXRD and SEM-EDS analysis shows that the C-S-H formed in HVFA system containing 50% or more of fly ash has a similar structure as C-S-H(I) with comparatively lower Ca/Si ratio than the one produced in PC system. Moreover, coexistence of C-S-H(I) and strätlingite is observed in the system containing 80% of fly ash, confirming that the amount of alumina and silicate phases provided by the fly ash is a major factor for the formation of C-S-H(I) and strätlingite in HVFA system. - Highlights: • High-volume fly ash (HVFA) paste was studied by scanning x-ray micro-diffraction. • Coexistence of C-S-H(I) and strätlingite in the HVFA system is clearly shown. • The distribution of minor phases in the HVFA system is shown. • Differences between inner and outer products of fly ash are observed by SEM-EDS.

36 MATERIALS SCIENCE↗

In-line monitoring of Li-ion battery electrode porosity and areal loading using active thermal scanning - modeling and initial experiment

This work focuses on a new technique called active thermal scanning for in-line monitoring of porosity and areal loading of Li-ion battery electrodes. In this technique a moving battery electrode is subjected to thermal excitation and the induced temperature rise is monitored using an infra-red camera. Static and dynamic experiments with speeds up to 1.5 m min -1 are performed on both cathodes and anodes and a combined micro- and macro-scale finite element thermal model of the system is developed. It is shown experimentally and through simulations that during thermal scanning the temperature profile generated in an electrode depends on both coating porosity (or area loading) and thickness. Here, it is concluded that by inverting this relation the porosity (or areal loading) can be determined, if thermal response and thickness are simultaneously measured.

25 ENERGY STORAGE↗

Development of an in situ ion irradiation scanning electron microscope

An in situ ion irradiation scanning electron microscope (I 3 SEM) has been developed, installed, and integrated into the Ion Beam Laboratory at Sandia National Laboratories. The I 3 SEM facility combines a field emission, variable pressure, scanning electron microscope, a 6 MV tandem accelerator, high flux low energy ion source, an 808 nm-wavelength laser, and multiple stages to control the thermal and mechanical state of the sample observed. The facility advances real-time understanding of materials evolution under combined environments at the mesoscale. As highlighted in multiple examples, this unique combination of tools is optimized for studying mesoscale material response in overlapping extreme environments, allowing for simultaneous ion irradiation, implantation, laser bombardment, conductive heating, cooling, and mechanical deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermodynamic analysis of a MEMS based differential scanning calorimeter model

Thin film based differential scanning calorimeter (DSC) was developed and utilized for the study of phase-transition kinetics in protein samples. In this paper, we proposed a MEMS based DSC model. The distance between the sample and reference cell was optimized based on the thermal analysis result. The influence of the response time to the shape of the DSC thermograms and the transition temperature was also studied systematically. Meanwhile, Lumry-Eyring model was used to investigate the relationship between the scanning rate and the transition temperature. The modeling result was verified by the lysozyme denaturation tests. This study provided a pathway for the optimization of MEMS based DSC array and the correction of the DSC thermograms.

47 OTHER INSTRUMENTATION↗

A power compensated differential scanning calorimeter for protein stability characterization

This study presented a power compensated MEMS differential scanning calorimeter (DSC) for protein stability characterization. In this microfabricated sensor, PDMS (Polydimethylsiloxane) and polyimide were used to construct the adiabatic chamber (1 μL) and temperature sensitive vanadium oxide was used as the thermistor material. A power compensation system was implemented to maintain the sample and reference at the same temperature. The resolution study and step response characterization indicated the high sensitivity (6 V/W) and low noise level (60 μk) of the device. The test with IgG1 antibody (mAb1) samples showed clear phase transitions and the data was confirmed to be reasonable by comparing it with the results of commercial DSC’s test. Finally, this device used ~1uL sample amount and could complete the scanning process in 4 min, significantly increasing the throughput of the bimolecular thermodynamics study like drug formulation process.

36 MATERIALS SCIENCE↗

Studies of x-ray localization and thickness dependence in atomic-scale elemental mapping by STEM energy-dispersive x-ray spectroscopy using single-frame scanning method

The delocalization of x-ray signals limits the spatial resolution in atomic-scale elemental mapping by scanning transmission electron microscopy (STEM) using energy-dispersive x-ray spectroscopy (EDS). In this study, using a SrTiO 3 [001] single crystal, we show that the x-ray localization to atomic columns is strongly dependent on crystal thickness, and a thin crystal is critical for improving the spatial resolution in atomic-scale EDS mapping. A single-frame scanning technique is used in this study instead of the multiple-frame technique to avoid peak broadening due to tracking error. The strong thickness dependence is realized by measuring the full width at half maxima (FWHM) as well as the peak-to-valley (P/V) ratio of the EDS profiles for Ti K and Sr K+L, obtained at several crystal thicknesses. A FWHM of about 0.16 nm and a P/V ratio of greater than 7.0 are obtained for Ti K for a crystal thickness of less than 20 nm. In conclusion, with increasing crystal thickness, the FWHM and P/V ratio increases and decreases, respectively, indicating the advantage of using a thin crystal for high-resolution EDS mapping.

36 MATERIALS SCIENCE↗

Morphological classification of bioaerosols from composting using scanning electron microscopy

Highlights: • Bioaerosols were captured using the filter method. • Bioaerosols were analysed using scanning electron microscope. • Bioaerosols were classified on the basis of morphology. • Single small cells were found more frequently than aggregates and larger cells. • Smaller cells may disperse further than heavier aggregate structures. - Abstract: This research classifies the physical morphology (form and structure) of bioaerosols emitted from open windrow composting. Aggregation state, shape and size of the particles captured are reported alongside the implications for bioaerosol dispersal after release. Bioaerosol sampling took place at a composting facility using personal air filter samplers. Samples were analysed using scanning electron microscopy. Particles were released mainly as small (<1 μm) single, spherical cells, followed by larger (>1 μm) single cells, with aggregates occurring in smaller proportions. Most aggregates consisted of clusters of 2–3 particles as opposed to chains, and were <10 μm in size. No cells were attached to soil debris or wood particles. These small single cells or small aggregates are more likely to disperse further downwind from source, and cell viability may be reduced due to increased exposure to environmental factors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Three-Dimensional Reconstruction Algorithm for Scanning Transmission Electron Microscopy Data from a Single Sample Orientation

Abstract Increasing interest in three-dimensional nanostructures adds impetus to electron microscopy techniques capable of imaging at or below the nanoscale in three dimensions. We present a reconstruction algorithm that takes as input a focal series of four-dimensional scanning transmission electron microscopy (4D-STEM) data. We apply the approach to a lead iridate, PbIrO, and yttrium-stabilized zirconia, YZrO, heterostructure from data acquired with the specimen in a single plan-view orientation, with the epitaxial layers stacked along the beam direction. We demonstrate that Pb–Ir atomic columns are visible in the uppermost layers of the reconstructed volume. We compare this approach to the alternative techniques of depth sectioning using differential phase contrast scanning transmission electron microscopy (DPC-STEM) and multislice ptychographic reconstruction.

47 OTHER INSTRUMENTATION↗

Viewing Optical Processes at the Nanoscale: Combining Scanning Tunneling Microscopy and Optical Spectroscopy

The combination of optical spectroscopy and scanning tunneling microscopy techniques has the potential to yield the unambiguous single-molecule level insight required to fully understand the complex structure–property relationship of emerging material systems. In this Perspective, we highlight the recent progress of single-molecule absorption detected by scanning tunneling microscopy (SMA-STM) to investigate light–matter interactions of supported (nano)particles, quantum dots, and molecular and thin films at the nanoscale. We further show how the SMA-STM technique has been recently extended to expand the classes of materials that can be investigated as well as recent design modifications that enable both time-resolved imaging and tomography. Finally, we hypothesize how these modifications can be further leveraged to advance our current knowledge of light–matter interactions and how the resulting nanoscale insight can be implemented for future material applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep Learning of Atomically Resolved Scanning Transmission Electron Microscopy Images: Chemical Identification and Tracking Local Transformations

Recent advances in scanning transmission electron and scanning probe microscopies have opened unprecedented opportunities in probing the materials structural parameters and various functional properties in real space with an angstrom-level precision. This progress has been accompanied by exponential increase in the size and quality of datasets produced by microscopic and spectroscopic experimental techniques. These developments necessitate adequate methods for extracting relevant physical and chemical information from the large datasets, for which a priori information on the structures of various atomic configurations and lattice defects is limited or absent. Here we demonstrate an application of deep neural networks to extracting information from atomically resolved images including location of the atomic species and type of defects. We develop a “weakly-supervised” approach that uses information on the coordinates of all atomic species in the image, extracted via a deep neural network, to identify a rich variety of defects that are not part of an initial training set. We further apply our approach to interpret complex atomic and defect transformation, including switching between different coordination of silicon dopants in graphene as a function of time, formation of peculiar silicon dimer with mixed 3-fold and 4-fold coordination, and the motion of molecular “rotor”. In conclusion, this deep learning based approach resembles logic of a human operator, but can be scaled leading to significant shift in the way of extracting and analyzing information from raw experimental data.

36 MATERIALS SCIENCE↗

Self-Assembly of Metallo-Supramolecules under Kinetic or Thermodynamic Control: Characterization of Positional Isomers Using Scanning Tunneling Spectroscopy

Coordination-driven self-assembly has been extensively employed to construct a variety of discrete structures as a bottom-up strategy. However, mechanistic understanding regarding whether self-assembly is under kinetic or thermodynamic control is less explored. To date, such mechanistic investigation has been limited to distinct, assembled structures. It still remains a formidable challenge to study the kinetic and thermodynamic behavior of self-assembly systems with multiple assembled isomers due to the lack of characterization methods. Herein, we use a stepwise strategy which combined self-recognition and self-assembly processes to construct giant metallo-supramolecules with 8 positional isomers in solution. With the help of ultrahigh-vacuum, low-temperature scanning tunneling microscopy and scanning tunneling spectroscopy, we were able to unambiguously differentiate 14 isomers on the substrate which correspond to 8 isomers in solution. Through measurement of 162 structures, the experimental probability of each isomer was obtained and compared with the theoretical probability. Finally, such a comparison along with density functional theory (DFT) calculation suggested that although both kinetic and thermodynamic control existed in this self-assembly, the increased experimental probabilities of isomers compared to theoretical probabilities should be attributed to thermodynamic control.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigating electrochemical corrosion at Mg alloy-steel joint interface using scanning electrochemical cell impedance microscopy (SECCIM)

Developing strategies to prevent corrosion at the interface of dissimilar metal alloys is challenging because of the presence of heterogenous distribution of galvanic couples and microstructural features that significantly change the corrosion rate. Devising strategies to mitigate this interfacial corrosion requires quantitative and correlative understanding of its surface electrochemical reaction. In this work, scanning electrochemical cell impedance microscopy (SECCIM) was employed to study location-specific corrosion in the interfacial region of dissimilar alloys, such as AZ31 (magnesium alloy) and DP590 (steel) welded using the Friction-stir Assisted Scribe Technique (FAST) processes. Herein, SECCM and SECCIM were used to perform correlative mapping of the local electrochemical impedance spectroscopic and potentiodynamic polarization to measure the effect of electronic and microstructural changes in the welded interfacial region on corrosion kinetics. Microstructural characterization including scanning electron microscopy and electron backscatter diffraction was performed to correlate changes in microstructural features and chemistry with the corresponding electronic properties that affect corrosion behavior. The variations in corrosion potential, corrosion current density, and electrochemical impedance spectroscopy behavior across the interface provide deeper insights on the interfacial region—which is chemically and microstructurally distinct from both bare AZ31 and DP590 that can help prevent corrosion in dissimilar metal structures.

59 BASIC BIOLOGICAL SCIENCES↗

Probing topological quantum matter with scanning tunnelling microscopy

The search for topological phases of matter is evolving towards strongly interacting systems, including magnets and superconductors, where exotic effects emerge from the quantum-level interplay between geometry, correlation and topology. Over the past decade or so, scanning tunnelling microscopy has become a powerful tool to probe and discover emergent topological matter, because of its unprecedented spatial resolution, high-precision electronic detection and magnetic tunability. Scanning tunnelling microscopy can be used to probe various topological phenomena, as well as complement results from other techniques. We discuss some of these proof-of-principle methodologies applied to probe topology, with particular attention to studies performed under a tunable vector magnetic field, which is a relatively new direction of recent focus. Finally, we then project the future possibilities for atomic-resolution tunnelling methods in providing new insights into topological matter.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The material dependence of temperature measurement resolution in thermal scanning electron microscopy

Thermal scanning electron microscopy is a recently developed temperature mapping technique based on thermal diffuse scattering in electron backscatter diffraction in a scanning electron microscope. It provides nano-scale and non-contact temperature mapping capabilities. Due to the specific temperature sensitive mechanism inherent to this technique, the temperature resolution is highly material dependent. A thorough investigation of what material properties affect the temperature resolution is important for realizing the inherent temperature resolution limit for each material. In this paper, three material dependent parameters-the Debye-Waller B-factor temperature sensitivity, backscatter yield, and lattice constant-are shown to control the temperature resolution.

36 MATERIALS SCIENCE↗