Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Laser desorption ionization and peptide sequencing on laser induced silicon microcolumn arrays

The present invention provides a method of producing a laser-patterned silicon surface, especially silicon wafers for use in laser desorption ionization (LDI-MS) (including MALDI-MS and SELDI-MS), devices containing the same, and methods of testing samples employing the same. The surface is prepared by subjecting a silicon substrate to multiple laser shots from a high-power picosecond or femtosecond laser while in a processing environment, e.g., underwater, and generates a remarkable homogenous microcolumn array capable of providing an improved substrate for LDI-MS.

47 OTHER INSTRUMENTATION↗

Stable Isotope Enrichment Capabilities at ORNL

The Oak Ridge National Laboratory (ORNL) and the US Department of Energy Nuclear Physics Program have built a high-resolution Electromagnetic Isotope Separator (EMIS) as a prototype for reestablishing a US based enrichment capability for stable isotopes. ORNL has over 60 years of experience providing enriched stable isotopes and related technical services to the international accelerator target community, as well as medical, research, industrial, national security, and other communities. ORNL is investigating the combined use of electromagnetic and gas centrifuge isotope separation technologies to provide research quantities (milligram to several kilograms) of enriched stable isotopes. In preparation for implementing a larger scale production facility, a 10 mA high-resolution EMIS prototype has been built and tested. Initial testing of the device has simultaneously collected greater than 98% enriched samples of all the molybdenum isotopes from natural abundance feedstock.

calutron↗

Means of introducing an analyte into liquid sampling atmospheric pressure glow discharge

A liquid sampling, atmospheric pressure, glow discharge (LS-APGD) device as well as systems that incorporate the device and methods for using the device and systems are described. The LS-APGD includes a hollow capillary for delivering an electrolyte solution to a glow discharge space. The device also includes a counter electrode in the form of a second hollow capillary that can deliver the analyte into the glow discharge space. A voltage across the electrolyte solution and the counter electrode creates the microplasma within the glow discharge space that interacts with the analyte to move it to a higher energy state (vaporization, excitation, and/or ionization of the analyte).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Means of introducing an analyte into liquid sampling atmospheric pressure glow discharge

A liquid sampling, atmospheric pressure, glow discharge (LS-APGD) device as well as systems that incorporate the device and methods for using the device and systems are described. The LS-APGD includes a hollow capillary for delivering an electrolyte solution to a glow discharge space. The device also includes a counter electrode in the form of a second hollow capillary that can deliver the analyte into the glow discharge space. A voltage across the electrolyte solution and the counter electrode creates the microplasma within the glow discharge space that interacts with the analyte to move it to a higher energy state (vaporization, excitation, and/or ionization of the analyte).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reversibly bonded devices and methods of making and using the same

The present disclosure concerns embodiments of reversibly bonded devices that comprise a reversible bonding component. The reversible bonding component is able to exhibit strong adhesive properties so as to couple device components, but upon exposure to an energy source, the strong adhesive properties are weakened. By weakening the adhesive strength of the reversible bonding component, the device can be deconstructed to access internal biological samples for analysis and characterization.

42 ENGINEERING↗

The Use of Transportable Processing Systems for the Treatment of Radioactive Nuclear Wastes

EnergySolutions has developed two major types of radioactive processing plants based on its experience in the USA and UK, and its exclusive North American access to the intellectual property and know-how developed over 50 years at the Sellafield nuclear site in the UK. Passive Secure Cells are a type of hot cell used in place of the Canyons typically used in US-designed radioactive facilities. They are used in permanent, large scale plants suitable for long term processing of large amounts of radioactive material. The more recently developed Transportable Processing Systems, which are the subject of this paper, are used for nuclear waste processing and clean-up when processing is expected to be complete within shorter timescales and when it is advantageous to be able to move the processing equipment amongst a series of geographically spread-out waste treatment sites. Such transportable systems avoid the construction of a monolithic waste processing plant which itself would require extensive decommissioning and clean-up when its mission is complete. This paper describes a range of transportable radioactive waste processing equipment that EnergySolutions and its partners have developed including: the portable MOSS drum-based waste grouting system, the skid mounted MILWPP large container waste grouting system, the IPAN skid-mounted waste fissile content non-destructive assay system, the Wiped Film Evaporator low liquid hold-up transportable evaporator system, the CCPU transportable solvent extraction cesium separation system, and the SEP mobile shielded cells for emptying radioactive debris from water-filled silos. Maximum use is made of proven, robust, and compact processing equipment such as centrifugal contactors, remote sampling systems, and cement grout feed and metering devices. Flexible, elastomer-based Hose-in-Hose assemblies and container-based transportable pump booster stations are used in conjunction with these transportable waste processing units for transferring radioactive waste from its source to the processing equipment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In situ scanning tunneling microscope tip treatment device for spin polarization imaging

A tip treatment device for use in an ultrahigh vacuum in situ scanning tunneling microscope (STM). The device provides spin polarization functionality to new or existing variable temperature STM systems. The tip treatment device readily converts a conventional STM to a spin-polarized tip, and thereby converts a standard STM system into a spin-polarized STM system. The tip treatment device also has functions of tip cleaning and tip flashing a STM tip to high temperature (>2000.degree. C.) in an extremely localized fashion. Tip coating functions can also be carried out, providing the tip sharp end with monolayers of coating materials including magnetic films. The device is also fully compatible with ultrahigh vacuum sample transfer setups.

47 OTHER INSTRUMENTATION↗

High mobility high efficiency organic films based on pure organic materials

A method of purifying small molecule organic material, performed as a series of operations beginning with a first sample of the organic small molecule material. The first step is to purify the organic small molecule material by thermal gradient sublimation. The second step is to test the purity of at least one sample from the purified organic small molecule material by spectroscopy. The third step is to repeat the first through third steps on the purified small molecule material if the spectroscopic testing reveals any peaks exceeding a threshold percentage of a magnitude of a characteristic peak of a target organic small molecule. The steps are performed at least twice. The threshold percentage is at most 10%. Preferably the threshold percentage is 5% and more preferably 2%. The threshold percentage may be selected based on the spectra of past samples that achieved target performance characteristics in finished devices.

36 MATERIALS SCIENCE↗

Operando X-ray Nanocharacterization of Polycrystalline Thin Film Modules

Non-destructive measurement techniques, with high spatial resolution, capable of correlating composition and structure with device properties, are few and far between. For the case of polycrystalline and inhomogeneous materials, the added challenge is that large sampling areas are necessary in order to have a statistical representation of the specimen under study. For the study of grain cores and grain boundaries in polycrystalline solar absorbers this is of particular importance since their dissimilar behavior and variability throughout the samples makes it difficult to draw conclusions and ultimately optimize the materials and devices. Our approach to use state-of-the-art x-ray microscopy to study full module stacks under operating conditions is unique. Understanding the effects of elemental and charge migration under full encapsulation and operating conditions will allow CIGS and CdTe manufactures and in particular our partners in this proposal to modify materials, stacks, architectures, and processing steps to minimize the performance losses through time.

14 SOLAR ENERGY↗

Microfluidic Biochip Design

As humans prepare for the exploration of our solar system, there is a growing need for miniaturized medical and environmental diagnostic devices for use on spacecrafts, especially during long-duration space missions where size and power requirements are critical. In recent years, the biochip (or Lab-on-a- Chip) has emerged as a technology that might be able to satisfy this need. In generic terms, a biochip is a miniaturized microfluidic device analogous to the electronic microchip that ushered in the digital age. It consists of tiny microfluidic channels, pumps and valves that transport small amounts of sample fluids to biosensors that can perform a variety of tests on those fluids in near real time. It has the obvious advantages of being small, lightweight, requiring less sample fluids and reagents and being more sensitive and efficient than larger devices currently in use. Some of the desired space-based applications would be to provide smaller, more robust devices for analyzing blood, saliva and urine and for testing water and food supplies for the presence of harmful contaminants and microorganisms. Our group has undertaken the goal of adapting as well as improving upon current biochip technology for use in long-duration microgravity environments. In addition to developing computational models of the microfluidic channels, valves and pumps that form the basis of every biochip, we are also trying to identify potential problems that could arise in reduced gravity and develop solutions to these problems. One such problem is due to the prevalence of bubbly sample fluids in microgravity. A bubble trapped in a microfluidic channel could be detrimental to the operation of a biochip. Therefore, the process of bubble formation in microgravity needs to be studied, and a model of this process has been developed and used to understand how bubbles develop and move through biochip components. It is clear that some type of bubble filter would be necessary in Space, and several bubble filter designs are being evaluated.

Panzarella, Charles↗

The Extensional Rheology of Non-Newtonian Materials

The evolution of the transient extensional stresses in dilute and semi-dilute viscoelastic polymer solutions are measured with a filament stretching rheometer of a design similar to that first introduced by Sridhar, et al. The solutions are polystyrene-based (PS) Boger fluids that are stretched at constant strain rates ranging from 0.6 less than or equal to epsilon(0) less than or equal to 4s(exp -1) and to Hencky strains of epsilon greater than 4. The test fluids all strain harden and Trouton ratios exceeding 1000 are obtained at high strains. The experimental data strain hardens at lower strain levels than predicted by bead-spring FENE models. In addition to measuring the transient tensile stress growth, we also monitor the decay of the tensile viscoelastic stress difference in the fluid column following cessation of uniaxial elongation as a function of the total imposed Hencky strain and the strain rate. The extensional stresses initially decay very rapidly upon cessation of uniaxial elongation followed by a slower viscoelastic relaxation, and deviate significantly from FENE relaxation predictions. The relaxation at long times t is greater than or equal to 5 s, is compromised by gravitational draining leading to non-uniform filament profiles. For the most elastic fluids, partial decohension of the fluid filament from the endplates of the rheometer is observed in tests conducted at high strain rates. This elastic instability is initiated near the rigid endplate fixtures of the device and it results in the progressive breakup of the fluid column into individual threads or 'fibrils' with a regular azimuthal spacing. These fibrils elongate and bifurcate as the fluid sample is elongated further. Flow visualization experiments using a modified stretching device show that the instability develops as a consequence of an axisymmetry-breaking meniscus instability in the nonhomogeneous region of highly deformed fluid near the rigid endplate.

Spiegelberg, Stephen H.↗

In situ measurement of fixed charge evolution at silicon surfaces during atomic layer deposition

Interfacial fixed charge or interfacial dipoles are present at many semiconductor-dielectric interfaces and have important effects upon device behavior, yet the chemical origins of these electrostatic phenomena are not fully understood. We report the measurement of changes in Si channel conduction in situ during atomic layer deposition (ALD) of aluminum oxide using trimethylaluminum and water to probe changes in surface electrostatics. Current-voltage data were acquired continually before, during, and after the self-limiting chemical reactions that result in film growth. Our measurements indicated an increase in conductance on p-type samples with p{sup +} ohmic contacts and a decrease in conductance on analogous n-type samples. Further, p{sup +} contacted samples with n-type channels exhibited an increase in measured current and n{sup +} contacted p-type samples exhibited a decrease in current under applied voltage. Device physics simulations, where a fixed surface charge was parameterized on the channel surface, connect the surface charge to changes in current-voltage behavior. The simulations and analogous analytical relationships for near-surface conductance were used to explain the experimental results. Specifically, the changes in current-voltage behavior can be attributed to the formation of a fixed negative charge or the modification of a surface dipole upon chemisorption of trimethylaluminum. These measurements allow for the observation of fixed charge or dipole formation during ALD and provide further insight into the electrostatic behavior at semiconductor-dielectric interfaces during film nucleation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal Characterization of the Universal Multizone Crystallizator

The Universal Multizone Crystallizator (UMC) is a special apparatus for crystal growth under terrestrial and microgravity conditions. The use of twenty-five zones allows the, UMC to be used for several normal freezing growth techniques. The thermal profile is electronically translated along the stationary sample by systematically reducing the power to the control zones. Elimination of mechanical translation devices increases the systems reliability while simultaneously reducing the size and weight. This paper addresses the UMC furnace design, sample cartridge, typical thermal profiles and corresponding power requirements necessary for two normal freezing techniques: dynamic gradient freeze and zone melting crystal growth.

Watring, D. A.↗

Electro-Optical Design for Efficient Visual Communication

Visual communication, in the form of telephotography and television, for example, can be regarded as efficient only if the amount of information that it conveys about the scene to the observer approaches the maximum possible and the associated cost approaches the minimum possible. Elsewhere we have addressed the problem of assessing the end to end performance of visual communication systems in terms of their efficiency in this sense by integrating the critical limiting factors that constrain image gathering into classical communications theory. We use this approach to assess the electro-optical design of image gathering devices as a function of the f number and apodization of the objective lens and the aperture size and sampling geometry of the phot-detection mechanism. Results show that an image gathering device that is designed to optimize information capacity performs similarly to the human eye. For both, the performance approaches the maximum possible, in terms of the efficiency with which the acquired information can be transmitted as decorrelated data, and the fidelity, sharpness, and clearity with which fine detail can be restored.

Huck, Friedrich O.↗

The Universal Multizone Crystallizator (UMC) Furnace: An International Cooperative Agreement

The Universal Multizone Crystallizator (UMC) is a special apparatus for crystal growth under terrestrial and microgravity conditions. The use of twenty-five zones allows the UMC to be used for several normal freezing growth techniques. The thermal profile is electronically translated along the stationary sample by systematically reducing the power to the control zones. Elimination of mechanical translation devices increases the systems reliability while simultaneously reducing the size and weight. This paper addresses the UMC furnace design, sample cartridge and typical thermal profiles and corresponding power requirements necessary for the dynamic gradient freeze crystal growth technique. Results from physical vapor transport and traveling heater method crystal growth experiments are also discussed.

Watring, D. A.↗

Combining Spatial and Temporal Resolution in Cryo-TEM of Device Materials: Preprint

Cryogenic transmission electron microscopy (cryo-TEM) has been instrumental to reducing the effects of electron-beam sample interactions and enabling higher spatial resolution studies of beam sensitive materials. However, the process of thinning and freezing samples for cryo-TEM characterization is often complex and frequently involves removing materials from their environment or stimuli of interest for extended times. This can allow for structural relaxation, diffusion, and other dynamic processes to occur prior to characterization; for energy materials like battery electrodes, this makes it difficult to precisely correlate the imaged structure with native structures that evolve in-situ during device processing, operation, or aging. Here, we present methods to prepare cryo-TEM samples from energy materials during these critical processes in the relevant device lifetimes. This offers insights into improving the temporal resolution of cryo-TEM, while still exploiting its ability to achieve high spatial resolutions in characterizing beam sensitive materials.

BASIC BIOLOGICAL SCIENCES,MATERIALS SCIENCE↗

Sparse Data Acquisition on Emerging Memory Architectures

Emerging memory devices, such as resistive crossbars, have the capacity to store large amounts of data in a single array. Acquiring the data stored in large-capacity crossbars in a sequential fashion can become a bottleneck. We present practical methods, based on sparse sampling, to quickly acquire sparse data stored on emerging memory devices that support the basic summation kernel, reducing the acquisition time from linear to sub-linear. Experimental results show that at least an order of magnitude improvement in acquisition time can be achieved when the data is sparse.

97 MATHEMATICS AND COMPUTING↗

In Vitro Thrombogenicity Testing of Biomaterials in a Dynamic Flow Loop: Effects of Length and Quantity of Test Samples

Abstract The results of in vitro dynamic thrombogenicity testing of biomaterials and medical devices can be significantly impacted by test conditions. To develop and standardize a robust dynamic in vitro thrombogenicity tool, the key test parameters need to be appropriately evaluated and optimized. We used a flow loop test system previously developed in our laboratory to investigate the effects of sample length and the number of samples per test loop on the thrombogenicity results. Porcine blood heparinized to a donor-specific target concentration was recirculated at room temperature through polyvinyl chloride (PVC) tubing loops containing test materials for 1 h at 200 mL/min. Four test materials (polytetrafluoroethylene (PTFE), latex, PVC, and silicone) with various thrombotic potentials in two sample lengths (12 and 18 cm) were examined. For the 12-cm long materials, two different test configurations (one and two samples per loop) were compared. Thrombogenicity was assessed through percent thrombus surface coverage, thrombus weight, and platelet count reduction in the blood. The test system was able to effectively differentiate the thrombogenicity profile of the materials (latex > silicone > PVC ≥ PTFE) at all test configurations. Increasing test sample length by 50% did not significantly impact the test results as both 12 and 18 cm sample lengths were shown to equally differentiate thrombotic potentials between the materials. The addition of a second test sample to each loop did not increase the test sensitivity and may produce confounding results, and thus a single test sample per loop is recommended.

Engineering↗