Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

A Study of the Effect of Increased Size and Speed of Pursuit Airplanes on the Aileron Balancing Problem

The present trend is toward faster and larger pursuit airplanes. Because both speed and size increase the aileron control forces, the design of ailerons for manual operation is becoming increasingly difficult. In order to obtain a clearer picture of the future problem of balancing ailerons, and inspection has been made of the effects of airplane size and speed on the control forces. Computations were made of the aileron control forces required to meet specified rolling conditions for plain ailerons on wings with spans from 40 to 80 feet and for speeds up to 500 miles per hour. The rolling conditions were specified by two alternative criterions. One was the rolling criterion pb/2V of reference 1. For reasons, which will be discussed later, a value of 0.09 rather than the recommended value of 0.07 was assigned to this criterion. For the criterion pb/2V, the required value of the rolling velocity p varies inversely with the airplane span b. There is some question as to whether the rolling velocity of a pursuit airplane can be permitted to decrease simply because its size is increased. For the second criterion, therefore, the rolling velocity is independent of span (p/V is a constant). The value assigned to this criterion was so chosen that for a wing of 40-foot span the value of pb/2V would be 0.09. The computations neglected compressibility effects. Available experimental data and the results of tests given in reference 2 indicate that the effect of compressibility is to increase the control force. Recent flight tests have indicated that, with certain types of aileron, serious compressibility effects may cause discontinuity at speeds of approximately 400 miles per hour in the aileron control force curves.

Soule, H. A.↗

Environmental indicators of biofuel sustainability: What about context?

Indicators of the environmental sustainability of biofuel production, distribution, and use should be selected, measured, and interpreted with respect to the context in which they are used. These indicators include measures of soil quality, water quality and quantity, greenhouse-gas emissions, biodiversity, air quality, and vegetation productivity. Contextual considerations include the purpose for the sustainability analysis, the particular biofuel production and distribution system (including supply chain, management aspects, and system viability), policy conditions, stakeholder values, location, temporal influences, spatial scale, baselines, and reference scenarios. Recommendations presented in this paper include formulating the problem for particular analyses, selecting appropriate context-specific indicators of environmental sustainability, and developing indicators that can reflect multiple environmental properties at low cost within a defined context. In addition, contextual considerations such as technical objectives, varying values and perspectives of stakeholder groups, and availability and reliability of data need to be understood and considered. Sustainability indicators for biofuels are most useful if adequate historical data are available, information can be collected at appropriate spatial and temporal scales, organizations are committed to use indicator information in the decision-making process, and indicators can effectively guide behavior toward more sustainable practices.

bioenergy↗

High-Precision Zinc Isotopic Measurement of Certified Reference Materials Relevant to the Environmental, Earth, Planetary and Biomedical Sciences

The zinc (Zn) stable isotope system has emerged as a powerful tool for investigating natural and anthropogenic processes of interest to disciplines extending from the Earth and planetary sciences to biomedical research. In nature, Zn isotopes typically fractionate ( 66 Zn/ 64 Zn) within the range of –1 and +1 permil (‰), and however, analytical limitations restrict the application of the Zn isotope system. Specifically, there is a lack of well-characterised matrix-matched reference materials covering most Zn isotope applications that are essential for validating laboratory performance, particularly given the contamination prone nature of Zn. Furthermore, the increasing demand for analysis of size-limited materials and sample types displaying small, sub-permil level Zn isotope variations requires improvements in measurement procedures. To address these limitations, the δ 66 Zn values of two pure Zn solutions and eighteen reference materials including the previously uncharacterised RGM-2, BCR-279, DOLT-4, DOLT-5, NASS-7, SBC-1, SGR-1b, MESS-3 and HISS-1, and the understudied QLO-1, SDC-1, BCR-414, NASS-6 and COQ-1 materials are reported. Furthermore, a 70 Zn- 67 Zn double-spike design has been implemented that routinely achieves intermediate measurement precision better than ± 0.02‰. This represents at least a two-fold improvement when compared with other double-spike designs, providing a robust platform of δ 66 Zn values required for quality control procedures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transformation from proper time on earth to coordinate time in solar system barycentric space-time frame of reference. I. II

It is noted that in order to obtain accurate computed values of earth-based range and Doppler observables of a deep space probe, an expression is required for the difference between coordinate time (t) in the solar system barycentric space-time frame of reference and proper time (tau) recorded on a fixed atomic clock on earth. This is part 1 of a two-part article which obtains an expression for the coordinate time/proper time difference that can be used in deriving computed values of observations of a spacecraft or celestial body located anywhere in the solar system. The expression can also be used in computing Very Long Baseline Interferometry data types. In part 1, expression for the coordinate time/proper time difference is obtained that is a function of position and velocity vectors of the major celestial bodies of the solar system and the atomic clock on earth which reads proper time. This expression is transformed in part 2 to a function of time and the earth-fixed coordinates of the atomic clock.

Moyer, T. D.↗

SU-F-T-284: The Effect of Linear Accelerator Output Variation On the Quality of Patient Specific Rapid Arc Verification Plans

Purpose: The aim of the current study is to investigate the effect of machine output variation on the delivery of the RapidArc verification plans. Methods: Three verification plans were generated using Eclipse™ treatment planning system (V11.031) with plan normalization value 100.0%. These plans were delivered on the linear accelerators using ArcCHECK− device, with machine output 1.000 cGy/MU at calibration point. These planned and delivered dose distributions were used as reference plans. Additional plans were created in Eclipse− with normalization values ranging 92.80%–102% to mimic the machine output ranging 1.072cGy/MU-0.980cGy/MU, at the calibration point. These plans were compared against the reference plans using gamma indices (3%, 3mm) and (2%, 2mm). Calculated gammas were studied for its dependence on machine output. Plans were considered passed if 90% of the points satisfy the defined gamma criteria. Results: The gamma index (3%, 3mm) was insensitive to output fluctuation within the output tolerance level (2% of calibration), and showed failures, when the machine output exceeds ≥3%. Gamma (2%, 2mm) was found to be more sensitive to the output variation compared to the gamma (3%, 3mm), and showed failures, when output exceeds ≥1.7%. The variation of the gamma indices with output variability also showed dependence upon the plan parameters (e.g. MLC movement and gantry rotation). The variation of the percentage points passing gamma criteria with output variation followed a non-linear decrease beyond the output tolerance level. Conclusion: Data from the limited plans and output conditions showed that gamma (2%, 2mm) is more sensitive to the output fluctuations compared to Gamma (3%,3mm). Work under progress, including detail data from a large number of plans and a wide range of output conditions, may be able to conclude the quantitative dependence of gammas on machine output, and hence the effect on the quality of delivered rapid arc plans.

60 APPLIED LIFE SCIENCES↗

Metal Standards for Waveguide Characterization of Materials

Rectangular-waveguide inserts that are made of non-ferromagnetic metals and are sized and shaped to function as notch filters have been conceived as reference standards for use in the rectangular- waveguide method of characterizing materials with respect to such constitutive electromagnetic properties as permittivity and permeability. Such standards are needed for determining the accuracy of measurements used in the method, as described below. In this method, a specimen of a material to be characterized is cut to a prescribed size and shape and inserted in a rectangular- waveguide test fixture, wherein the specimen is irradiated with a known source signal and detectors are used to measure the signals reflected by, and transmitted through, the specimen. Scattering parameters [also known as "S" parameters (S11, S12, S21, and S22)] are computed from ratios between the transmitted and reflected signals and the source signal. Then the permeability and permittivity of the specimen material are derived from the scattering parameters. Theoretically, the technique for calculating the permeability and permittivity from the scattering parameters is exact, but the accuracy of the results depends on the accuracy of the measurements from which the scattering parameters are obtained. To determine whether the measurements are accurate, it is necessary to perform comparable measurements on reference standards, which are essentially specimens that have known scattering parameters. To be most useful, reference standards should provide the full range of scattering-parameter values that can be obtained from material specimens. Specifically, measurements of the backscattering parameter (S11) from no reflection to total reflection and of the forward-transmission parameter (S21) from no transmission to total transmission are needed. A reference standard that functions as a notch (band-stop) filter can satisfy this need because as the signal frequency is varied across the frequency range for which the filter is designed, the scattering parameters vary over the ranges of values between the extremes of total reflection and total transmission. A notch-filter reference standard in the form of a rectangular-waveguide insert that has a size and shape similar to that of a material specimen is advantageous because the measurement configuration used for the reference standard can be the same as that for a material specimen. Typically a specimen is a block of material that fills a waveguide cross-section but occupies only a small fraction of the length of the waveguide. A reference standard of the present type (see figure) is a metal block that fills part of a waveguide cross section and contains a slot, the long dimension of which can be chosen to tailor the notch frequency to a desired value. The scattering parameters and notch frequency can be estimated with high accuracy by use of commercially available electromagnetic-field-simulating software. The block can be fabricated to the requisite precision by wire electrical-discharge machining. In use, the accuracy of measurements is determined by comparison of (1) the scattering parameters calculated from the measurements with (2) the scattering parameters calculated by the aforementioned software.

Lambert, Kevin M.↗

Preliminary Results of the 1.5% TCA (Modular) Controls Model in the NASA Langley UPWT

To summarize the significant highlights in this report: (1) Data quality, determined by multiple repeat runs performed on the TCA baseline configuration, and long-term repeatability, determined by comparing baseline Reference H data from this test to a previous test, have been shown to be good. (2) The longitudinal stability of the TCA is more non-linear than for the Reference H, and while it is similar at normal lift values, the TCA has considerably more pitch-up at higher lift. (3) Longitudinal control effectiveness of the TCA is similar to the Reference H and the ratio of elevator effectiveness to horizontal tail effectiveness is approximately 0.3. 4) The directional stability of the TCA is improved relative to Reference H at higher angles-of attack. The chine is effective for improving directional stability. (5) The directional control effectiveness 'of the TCA rudder is the same as that of the Reference H rudder at low angles-of-attack, after taking factors, such as number of rudder panels deflected and vertical tail volume into account. However, rudder effectiveness was shown to be reduced at higher angles-of-attack. (6) The lateral stability was shown to be reduced relative to the Reference H, which may be beneficial at low speeds for alleviating lateral control saturation. (7) Lateral control effectiveness for the TCA was shown to be similar to the Reference H for negative trailing-edge flap deflections and was reduced by approximately 25% for positive trailing-edge flap deflections.

Kubiatko, Paul↗

Preliminary Results of the 1.5% TCA (Modular) Controls Model in the NASA Langley UPWT

To summarize the significant highlights in this report: (1) Data quality, determined by multiple repeat runs performed on the TCA baseline configuration, and long-term repeatability, determined by comparing baseline Reference H data from this test to a previous test, have been shown to be good. (2) The longitudinal stability of the TCA is more non-linear than for the Reference H, and while it is similar at normal lift values, the TCA has considerably more pitch-up at higher lift. (3) Longitudinal control effectiveness of the TCA is similar to the Reference H and the ratio of elevator effectiveness to horizontal tail effectiveness is approximately 0.3. (4) The directional stability of the TCA is improved relative to Reference H at higher angles-of attack. The chine is effective for improving directional stability.

Kubiatko, Paul↗

Assessing the Performance of Exchange‐Correlation Density Functionals in Describing the Iron‐Catalyzed Ammonia Synthesis System

Density functional theory (DFT) has been widely employed for elucidating mechanistic aspects of heterogeneous catalysis. However, the accuracy of DFT calculations relies heavily on selecting an exchange-correlation (XC) functional that correctly describes the electronic structure of materials involved in the reactions. This study assesses the accuracy of several XC density functionals for modeling the iron-catalyzed ammonia synthesis system. In the assessment of functional accuracy, experimental references are compared to DFT-calculated values for the formation energy of gas-phase ammonia and nitrogen, bulk Fe/Fe-nitride (γ′-Fe 4 N) lattice constants and cohesive/formation energies, and nitrogen and ammonia binding energies on Fe(100), Fe(111), Fe(110), and γ′-Fe 4 N(111). It is observed that the experimental value for each of these descriptors is accurately modeled by at least one functional. RPBE alone provides reliable estimates for both the lattice constant and cohesive energy of Fe and γ′-Fe 4 N. Temperature-programmed desorption experiments led to estimates for N and NH 3 adsorption across several Fe-based facets that are best captured by RPBE. These results highlight the importance of choosing an appropriate XC functional that accurately describes experimental systems and offer insights into effectively modeling the interactions between nitrogen and ammonia on Fe-based surfaces.

adsorption↗

Diagnostic accuracy of acoustic radiation force impulse elastography (ARFI) in comparison to other non-invasive modalities in staging of liver fibrosis in chronic HCV patients: single-center experience

Purpose: To evaluate the reliability of ARFI elastography for liver fibrosis staging and compare it to other non-invasive assessment of hepatic fibrosis (FIB-4 and APRI) in chronic HCV (CHC) patients. Methods: A single-center, prospective study included 2103 CHC patients. Liver stiffness (LS) was evaluated by TE and ARFI elastography. FIB-4 and APRI were calculated. The area under the receiver-operating characteristic curve (AUROCs) was used to assess the diagnostic performance of ARFI elastography for staging of liver fibrosis using TE as a reference standard. Results: The best cut off values of ARFI elastography for diagnosis of ≥ F2, ≥ F3and F4 were 1.36 m/s, 1.45 m/s, and 1.7 m/s with AUROCs of 0.89, 0.94 and 0.95, respectively. ARFI elastography cut offs are lower in patients with normal ALT level compared to those with ALT level (1.1–< 3 ULN) and those with ALT level ≥ 3ULN (1.35 m/s vs 1.39 m/s vs 1.54 for F ≥ 2, 1.44 m/s vs 1.58 m/s vs 1.6 m/s for F3, 1.69 m/s, 1.84 m/s, 1.86 m/s for F4). FIB-4 (0.82–0.86) and APRI (0.78–0.82) yielded lower AUC in prediction of significant fibrosis and cirrhosis than ARFI elastography (0.89–0.95). Conclusion: ARFI elastography is a reliable method for non-invasive staging of liver fibrosis in CHC patients when compared to TE with a good diagnostic performance comparable to FIB-4 and APRI scores for the prediction of significant fibrosis and cirrhosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficiency Improvement in a Busy Radiology Practice: Determination of Musculoskeletal Magnetic Resonance Imaging Protocol Using Deep-Learning Convolutional Neural Networks

The purposes of this study are to evaluate the feasibility of protocol determination with a convolutional neural networks (CNN) classifier based on short-text classification and to evaluate the agreements by comparing protocols determined by CNN with those determined by musculoskeletal radiologists. Following institutional review board approval, the database of a hospital information system (HIS) was queried for lists of MRI examinations, referring department, patient age, and patient gender. These were exported to a local workstation for analyses: 5258 and 1018 consecutive musculoskeletal MRI examinations were used for the training and test datasets, respectively. The subjects for pre-processing were routine or tumor protocols and the contents were word combinations of the referring department, region, contrast media (or not), gender, and age. The CNN Embedded vector classifier was used with Word2Vec Google news vectors. The test set was tested with each classification model and results were output as routine or tumor protocols. The CNN determinations were evaluated using the receiver operating characteristic (ROC) curves. The accuracies were evaluated by a radiologist-confirmed protocol as the reference protocols. The optimal cut-off values for protocol determination between routine protocols and tumor protocols was 0.5067 with a sensitivity of 92.10%, a specificity of 95.76%, and an area under curve (AUC) of 0.977. The overall accuracy was 94.2% for the ConvNet model. All MRI protocols were correct in the pelvic bone, upper arm, wrist, and lower leg MRIs. Deep-learning-based convolutional neural networks were clinically utilized to determine musculoskeletal MRI protocols. CNN-based text learning and applications could be extended to other radiologic tasks besides image interpretations, improving the work performance of the radiologist.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Effect of Carboxyl Group Content on Water Uptake Capacity and Tensile Properties of Functionalized Soy Protein-Based Superabsorbent Plastics

This manuscript studies the relation between macroscopic properties of the soy protein isolate (SPI)-based superabsorbent polymers (SAP) (e.g., water uptake capacity and tensile properties) and the extent of chemical modification conducted on the protein. The increase in the carboxyl group content, obtained from electrometric titrations, for acylated systems compared to native SPI brings with it an improvement in the protein hydrophilic character, as revealed by the determination of the water imbibing capacity. SEM images show that larger porous regions were developed in the acylated plastics. As for their mechanical properties, static tensile measurements indicated that acylated plastics with greater water uptake values display higher extensibility, compared to the reference sample. These natural-based SAP materials could be appropriate for applications in which maintaining the dimensional stability during service is not crucial (e.g. in agriculture and horticulture).

36 MATERIALS SCIENCE↗

Effects of Laser-Cutting and Spark Erosion Techniques and Heat Treatment on the Magnetic Properties of Grain-Oriented Transformer Steels

Spark erosion and laser-cutting processes were examined in terms of their effects on the magnetic properties of grain-oriented electrical steels at working frequencies. The maximum permeability value in each case was considered a reference to determine the quantitative effect of cutting and eroding methods as well as the effects of heat treatment. To minimize the deterioration that appears after the piercing process is implemented, the specimens were subjected to heat treatment at the most appropriate temperature. The influence of stress-relief annealing could be observed throughout the domain refinement on the surface by using magneto-optical Kerr microscopy. Additionally, it was clearly seen that the domain contrast at the cut edge of the spark-eroded sample was more uniform than that provided by laser cutting upon applying a high AC-field amplitude.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of a Thermal Transport Database for Air Plasma Sprayed ZrO2 ? Y2O3 Thermal Barrier Coatings

Thermal Diffusivities of Air Plasma Sprayed (APS) thermal barrier coatings (TBCs) are measured by the laser flash method. The data are used to calculate thermal conductivity of TBCs when provided with density and specific heat data. Due to the complicated microstructure and other processing related parameters, thermal diffusivity of TBCs can vary as much as three to four fold. Data collected from over 200 free-standing ZrO2 7-8 wt%Y2O3 TBCs are presented. The large database gives a clear picture of the expected band of thermal diffusivity values. When this band is used as reference for thermal diffusivity of a specific TBC, the thermal transport property of TBC can be more precisely described. The database is intended to serve researchers and manufacturers of TBCs as a valuable source for evaluating their coatings.

36 MATERIALS SCIENCE↗

Convective heat transfer to CO{sub 2} at a supercritical pressure flowing vertically upward in tubes and an annular channel

The Super-Critical Water-Cooled Reactor (SCWR) has been chosen by the Generation IV International Forum as one of the candidates for the next generation nuclear reactors. Heat transfer to water from a fuel assembly may deteriorate at certain supercritical pressure flow conditions and its estimation at degraded conditions as well as in normal conditions is very important to the design of a safe and reliable reactor core. Extensive experiments on a heat transfer to a vertically upward flowing CO{sub 2} at a supercritical pressure in tubes and an annular channel have been performed. The geometries of the test sections include tubes of an internal diameter (ID) of 4.4 and 9.0 mm and an annular channel (8 x 10 mm). The heat transfer coefficient (HTC) and Nusselt numbers were derived from the inner wall temperature converted by using the outer wall temperature measured by adhesive K-type thermocouples and a direct (tube) or indirect (annular channel) electric heating power. From the test results, a correlation, which covers both a deteriorated and a normal heat transfer regime, was developed. The developed correlation takes different forms in each interval divided by the value of parameter Bu. The parameter Bu (referred to as Bu hereafter), a function of the Grashof number, the Reynolds number and the Prandtl number, was introduced since it is known to be a controlling factor for the occurrence of a heat transfer deterioration due to a buoyancy effect. The developed correlation predicted the HTCs for water and HCFC-22 fairly well. (author)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Second Harmonic Generation Electric Field Triplet Interferometry for Absolute Phasing

We report second harmonic generation (SHG) electric field triplet interferometry performed using three mutually coherent ultrafast pulses in a common path with controllable relative phases, namely, the light fields of a sample signal (SI), a reference oscillator (RO), and a local oscillator (LO). The ROLO phase determined from the interference of the light fields produced by two quartz wafers is subtracted from the phase determined from the SIROLO interferogram to yield the signal phase, ϕ SI . The new method also calibrates the measured SHG intensity from a given sample internally by sending the fundamental light field reflected from the sample into one of the quartz wafers in the ROLO element. The approach avoids having to exchange the sample against a reference material with a known χ(2) value or known phase and accounts on-the-fly for situations where the reflected fundamental light field intensity changes with experimental conditions. The new method is successfully benchmarked against z-cut α-quartz, fused silica held at its point of zero charge, and hematite nanolayers in air, across three different interferometers. Furthermore, the approach should be applicable for other second-order nonlinear spectroscopies, such as vibrational or electronic sum-frequency generation.

Interfaces↗

Cross-correlation based time delay estimation for turbulent flow velocity measurements: Statistical considerations

Time delay estimation methods (TDE) are well-known techniques to investigate poloidal flows in hot magnetized plasmas through the propagation properties of turbulent structures in the medium. One of these methods is based on the estimation of the time lag at which the cross-correlation function (CCF) estimation reaches its maximum value. The uncertainty of the peak location refers to the smallest determinable flow velocity modulation, and therefore the standard deviation of the time delay imposes important limitation to the measurements. In this article, the relative standard deviation of the CCF estimation and the standard deviation of its peak location are calculated analytically using a simple model of turbulent signals. This model assumes independent (non interacting) overlapping events (coherent structures) with randomly distributed spatio-temporal origins moving with background flow. The result of our calculations is the derivation of a general formula for the CCF variance, which is valid not exclusively in the high event density limit, but also for arbitrary event densities. Our formula reproduces the well known expression for high event densities previously published in the literature. In this paper we also present a derivation of the variance of time delay estimation that turns out to be inversely proportional to the applied time window. The derived formulas were tested in real plasma measurements. The calculations are an extension of the earlier work of Bencze and Zoletnik [Phys. Plasmas 12, 052323 (2005)] where the autocorrelation-width technique was developed. Additionally, we show that velocities calculated by a TDE method possess a broadband noise which originates from this variance, its power spectral density cannot be decreased by worsening the time resolution and can be coherent with noises of other velocity measurements where the same turbulent structures are used. This noise should not be confused with the impact of zero mean frequency zonal flow modulations and can be the explanation for the TEXTOR velocity spectra measured by beam emission spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Non-invasive low charge electron beam time-of-arrival diagnostic using a plasmonics-enhanced photoconductive antenna

The use of a plasmonics-enhanced photoconductive antenna (PCA) optically gated by a near infrared (NIR) pulse enables non-invasive time-of-arrival measurements of a low charge electron beam with respect to the NIR reference, achieving picosecond resolution. The measured signal values show the expected scaling with the beam charge and distance from PCA to the beam axis, as the PCA samples the electric field of the passing electron beam. We operate the device with an NIR spot size much larger than the PCA active-area, resulting in a very simple optical setup and alignment procedure, making the plasmonics-enhanced PCA a preferred alternative to more complex timing diagnostics for applications requiring non-invasive picosecond or sub-picosecond timestamping.

43 PARTICLE ACCELERATORS↗