Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

The Effect of Pro-Qura Case Volume on Post-Implant Prostate Dosimetry

Purpose: To evaluate the effect of prostate brachytherapy case volume on postimplant dosimetric quality in Pro-Qura proctored programs. Methods and Materials: From August 1999 to December 2008, the computed tomography datasets for 6,600 prostate implants performed by 129 brachytherapists were submitted to Pro-Qura for dosimetric analysis. Brachytherapists were divided into three roughly equal-sized terciles based on total case volume. Postimplant computed tomography scans were obtained at a median of 30 days. Excellent target coverage was defined by a V100 {>=}90% and D90 {>=}100% minimum prescribed peripheral dose. To determine if the number of excellent implants improved with increasing case numbers, each brachytherapist's series of implants was bisected into early and late experience by a moveable critical point. Results: For the entire cohort, the mean V100 and D90 were 89.2% and 102.8%, respectively, with 47.7% of the implants scored as excellent. Brachytherapists in the highest-case tercile had a significantly greater fraction of excellent target coverage (57.9%) than did those in the two lower terciles (39.5% and 45.7%, p = 0.015). Twenty-one (25.6%) of the 82 brachytherapists with sufficient case volume for dosimetric improvement analyses demonstrated quality improvement over time. Although there was no significant difference between prostate volume and seed strength, the number of seeds used was significantly greater in adequate implants. Conclusions: The highest-volume brachytherapists were most likely to obtain excellent target coverage. We are encouraged that in general practice, nearly 48% of all implants were scored excellent. It is conceivable that with greater expert third-party involvement, an even greater percentage of cases with excellent target coverage will become reality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hydrogen station in situ back-to-back fueling data for design and modeling

Hydrogen technologies are rapidly spreading, with significant attention to the mobility sector requiring a robust and widespread fueling infrastructure. Hydrogen stations are indeed fundamental to transitioning from pilot projects towards large-scale implementation in many countries. Operating under extreme conditions, the new stations need more informed designs and equipment to meet the growing demand and their more frequent utilization. Via a set of experimental research activities and investigated scenarios carried out at the Cal State LA Hydrogen Research and Fueling Facility, here this paper shares a novel and comprehensive set of data collected over a period of one year on fueling events frequency and refueling process station behaviors. A performance evaluation of the station is presented under different load scenarios in severe conditions during "back-to-back fuelings", with monitoring of fundamental parameters for infrastructure sizing, including dynamic cooling response, pressure levels, thermodynamics, and the state of charge of the vehicle. The presented data analysis could surely contribute as closer-to-reality inputs for a variety of station performance modeling tools.

08 HYDROGEN↗

Direct coupling of a genome-scale microbial in silico model and a groundwater reactive transport model

The activity of microorganisms often plays an important role in dynamic natural attenuation or engineered bioremediation of subsurface contaminants, such as chlorinated solvents, metals, and radionuclides. To evaluate and/or design bioremediated systems, quantitative reactive transport models are needed. State-of-the-art reactive transport models often ignore the microbial effects or simulate the microbial effects with static growth yield and constant reaction rate parameters over simulated conditions, while in reality microorganisms can dynamically modify their functionality (such as utilization of alternative respiratory pathways) in response to spatial and temporal variations in environmental conditions. Constraint-based genome-scale microbial in silico models, using genomic data and multiple-pathway reaction networks, have been shown to be able to simulate transient metabolism of some well studied microorganisms and identify growth rate, substrate uptake rates, and byproduct rates under different growth conditions. These rates can be identified and used to replace specific microbially-mediated reaction rates in a reactive transport model using local geochemical conditions as constraints. We previously demonstrated the potential utility of integrating a constraint based microbial metabolism model with a reactive transport simulator as applied to bioremediation of uranium in groundwater. However, that work relied on an indirect coupling approach that was effective for initial demonstration but may not be extensible to more complex problems that are of significant interest (e.g., communities of microbial species, multiple constraining variables). Here, we extend that work by presenting and demonstrating a method of directly integrating a reactive transport model (FORTRAN code) with constraint-based in silico models solved with IBM ILOG CPLEX linear optimizer base system (C library). The models were integrated with BABEL, a language interoperability tool. The modeling system is designed in such a way that constraint-based models targeting different microorganisms or competing organism communities can be easily plugged into the system. Constraint-based modeling is very costly given the size of a genome-scale reaction network. To save computation time, a binary tree is traversed to examine the concentration and solution pool generated during the simulation in order to decide whether the constraint-based model should be called. We also show preliminary results from the integrated model including a comparison of the direct and indirect coupling approaches.

54 ENVIRONMENTAL SCIENCES↗

Adaptive scapula bone remodeling computational simulation: Relevance to regenerative medicine

Shoulder arthroplasty success has been attributed to many factors including, bone quality, soft tissue balancing, surgeon experience, and implant design. Improved long-term success is primarily limited by glenoid implant loosening. Prosthesis design examines materials and shape and determines whether the design should withstand a lifetime of use. Finite element (FE) analyses have been extensively used to study stresses and strains produced in implants and bone. However, these static analyses only measure a moment in time and not the adaptive response to the altered environment produced by the therapeutic intervention. Computational analyses that integrate remodeling rules predict how bone will respond over time. Recent work has shown that subject-specific two- and three dimensional adaptive bone remodeling models are feasible and valid. Feasibility and validation were achieved computationally, simulating bone remodeling using an intact human scapula, initially resetting the scapular bone material properties to be uniform, numerically simulating sequential loading, and comparing the bone remodeling simulation results to the actual scapula’s material properties. Three-dimensional scapula FE bone model was created using volumetric computed tomography images. Muscle and joint load and boundary conditions were applied based on values reported in the literature. Internal bone remodeling was based on element strain-energy density. Initially, all bone elements were assigned a homogeneous density. All loads were applied for 10 iterations. After every iteration, each bone element’s remodeling stimulus was compared to its corresponding reference stimulus and its material properties modified. The simulation achieved convergence. At the end of the simulation the predicted and actual specimen bone apparent density were plotted and compared. Location of high and low predicted bone density was comparable to the actual specimen. High predicted bone density was greater than actual specimen. Low predicted bone density was lower than actual specimen. Differences were probably due to applied muscle and joint reaction loads, boundary conditions, and values of constants used. Work is underway to study this. Nonetheless, the results demonstrate three dimensional bone remodeling simulation validity and potential. Such adaptive predictions take physiological bone remodeling simulations one step closer to reality. Computational analyses are needed that integrate biological remodeling rules and predict how bone will respond over time. We expect the combination of computational static stress analyses together with adaptive bone remodeling simulations to become effective tools for regenerative medicine research.

60 APPLIED LIFE SCIENCES↗

Machine-to-machine variability of roughness and corrosion in additively manufactured 316L stainless steel

Numerous studies on the corrosion response of metal AM have been conducted. Nonetheless, the specimens being tested are commonly ground or polished to remove the outer as-built surface. If metal AM is truly going to be employed as a transformative technology that can produce complex shapes that do not require traditional machining, then the material needs to be evaluated in the as-built state. The reality is that AM alloys have shown significant inconsistencies regarding as-built surface texture, topology, and residual stress. One metric that has shown significant unpredictability in the literature is the susceptibility to localized corrosion of typically passive alloys, such as stainless steel (SS). There are a large number of studies that have attempted to understand the corrosion response of metal AM materials, but these studies are typically performed on materials that have been printed on a single machine and often mechanically polished to a smooth finish. This study compares the corrosion response of as-built AM, laser-beam powder bed fusion (LB-PBF), 316L SS parts that have been fabricated on five different machines. The majority of this work focused on understanding the susceptibility to localized corrosion of AM metals with respect to machine-dependent variables, namely surface roughness, and build angle. Surface roughness data was collected using scanning white light triangulation, laser scanning confocal microscopy, and coherence scanning interferometry. The results show that there is significant variability (p two-tail < 0.05) in the susceptibility to local corrosion initiation of LB-PBF 316L SS samples built on different machines. Surface oxides were probed with electron dispersive spectroscopy and revealed that variations in local corrosion susceptibility likely arise from differences in the stability of the passive film caused by chemical segregation, unique microstructure, and tortuous roughness features at the as-built surfaces. The variability of roughness and corrosion properties from test samples printed on different machines was corroborated by property measurements performed at five different testing sites, proving reproducibility of the data. Most importantly, this study shows that if the as-built surface layer is removed through grinding or electropolishing the machine-to-machine variation observed in the corrosion susceptibility is reduced.

36 MATERIALS SCIENCE↗

PracticeCALM: Coaching Anxiety Lessening Methods for Radiation Therapists: A Pilot Study of a Skills-Based Training Program in Radiation Oncology

PracticeCALM is an 8-week on-the-job training program to teach radiation therapists (RTs) techniques for assisting patients who are experiencing treatment-related anxiety. Twelve clinical RTs in a regional oncology program were recruited on a volunteer basis to participate in the training. A mixed-method approach was undertaken to evaluate perceived benefits to clinical practice. The quantitative findings from the Perceived Stress Scale (PSS) showed there were no changes before and after training. Qualitative findings showed significant benefits to RTs, including (1) ability to empathically attune more effectively and earlier to signs of anxiety in patients; (2) improved confidence and self-efficacy for effectively intervening in difficult treatment situations; and (3) enhanced creative problem solving in partnership with patients to assist the acutely anxious patient. The PSS results suggest that intrinsic and extrinsic stressors are a variable but consistent part of the everyday reality of RT practice. A training program focusing on the therapeutic presence dimension of RT practice has a direct impact on effectiveness in assisting anxious patients undergoing RT. When embedded in the clinical life of a radiation therapy department, such a training program has the potential to capture the lived practice wisdom and creative skills of RTs, and effectively mediate these skills across a team through group discussions and documentation on patient charts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

State of the art, gaps, and prospects in fusion materials theory and modelling

Advancing the theory and simulation of materials for fusion applications remains a key component of global roadmaps aimed at delivering much-needed fusion power. Especially as the drive for commercial application increases, prototypes must be designed against radiation damage before the relevant experimental data can be collected and cost reductions that are possible by testing materials in silico become even more important. Here, we summarise the state of the art as it emerged during the 7 th Fusion Materials Theory & Modelling Workshop that took place in 2024, with the aim to highlight present gaps and future directions for the fusion materials modelling community. Of particular interest were the effects of transmutations, chemical complexity with the development of novel alloys and interatomic potentials, advancements in modelling high-dose microstructures, comparison with experimental data and multiscale models for structural assessment relying on high-performance computing and virtual reality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of thermostat location for multizone commercial building performance

In multi-zone buildings, it is often found that a single shared thermostat controls more than one conditioned zones. Although these shared zones are supposed to have similar thermal needs (e.g., cooling and heating load), in reality, they are not mainly due to different orientations, sizes of windows, occupancy, space types, etc. This can cause unnecessary energy waste or thermal discomfort for the occupants. How to quantify this impact in multizone buildings remains a research gap. Therefore, this study aims to evaluate the impact of different sensor (i.e., thermostat) locations for multizone commercial buildings through a comprehensive modeling study. Here, two different scenarios for the sensor locations were selected to evaluate the impact in terms of energy and thermal comfort. The scenario (1) is that one to five sensors distributed among the five zones, but the sensor readings from selected zones will be used for no-sensor zones, which is no-mean sensor scenario. The scenario (2) is that one to five sensors distributed among the five zones, but the average temperature from the shared zones will be used for each of the shared zones, which is a mean sensor scenario. The uncertainty analysis was performed for different sensor location scenarios.(a)The major findings from an energy perspective, for scenario (1), the differences of cooling energy go as high as 17% more or 12% less, compared with the baseline. For heating energy consumption, the discrepancies go as high as 51% more or 52% less, compared with baseline. For site energy consumption, the discrepancies go as high as 3.2% more or 3.2% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.2% more or as low as 1.0% less, compared with baseline. For scenario (2), the discrepancies of cooling energy go as high as 3% more, or 0.5% less, compared with the baseline. For heating energy consumption, the discrepancies, are go as high as 10.1% more or as low as 3.0% less, compared with baseline. For site energy consumption, the discrepancies go as high as 1.3% more or 0.3% less, compared with baseline. For fan energy consumption, the discrepancies go as high as 3.1% more or as low as 1.0% less, compared with baseline.(b) In terms of the indoor thermal comfort, for the no-mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 1,200 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 740 h, compared with the baseline. For the mean-sensor scenarios, the discrepancies of unmet hours for cooling mode can be as high as 750 h, compared with the baseline. The discrepancies of unmet hours for heating mode can be as high as 50 h, compared with the baseline.

42 ENGINEERING↗

Countdown to perovskite space launch: Guidelines to performing relevant radiation-hardness experiments

Perovskite photovoltaics (PVs) are under intensive development for promise in terrestrial energy production. Soon, the community will find out how much of that promise may become reality. Perovskites also open new opportunities for lower cost space power. However, radiation tolerance of space environments requires appropriate analysis of relevant devices irradiated under representative radiation conditions. We present guidelines designed to rigorously test the radiation tolerance of perovskite PVs. We review radiation conditions in common orbits, calculate nonionizing and ionizing energy losses (NIEL and IEL) for perovskites, and prioritize proton radiation for effective nuclear interactions. Low-energy protons (0.05-0.15 MeV) create a representative uniform damage profile, whereas higher energy protons (commonly used in ground-based evaluation) require significantly higher fluence to accumulate the equivalent displacement damage dose due to lower scattering probability. Furthermore, high-energy protons may "heal" devices through increased electronic ionization. These procedural guidelines differ from those used to test conventional semiconductors.

14 SOLAR ENERGY↗

Chemical vapour deposition of thermochromic vanadium dioxide thin films for energy efficient glazing

Vanadium dioxide is a thermochromic material that undergoes a semiconductor to metal transitions at a critical temperature of 68 °C. This phase change from a low temperature monoclinic structure to a higher temperature rutile structure is accompanied by a marked change in infrared reflectivity and change in resistivity. This ability to have a temperature-modulated film that can limit solar heat gain makes vanadium dioxide an ideal candidate for thermochromic energy efficient glazing. In this review we detail the current challenges to such glazing becoming a commercial reality and describe the key chemical vapour deposition technologies being employed in the latest research. - Graphical abstract: Schematic demonstration of the effect of thermochromic glazing on solar radiation (red arrow represents IR radiation, black arrow represents all other solar radiation). - Highlights: • Vanadium dioxide thin films for energy efficient glazing. • Reviews chemical vapour deposition techniques. • Latest results for thin film deposition for vanadium dioxide.

36 MATERIALS SCIENCE↗

Predicting phase behavior in high entropy and chemically complex alloys

The interest in high entropy alloys and other metallic compounds with four or more elements at near-equiatomic ratios has drawn attention to the ability to rapidly predict phase behavior of these complex materials, particularly where existing thermodynamic data are lacking. In this paper, we discuss aspects of this from the point of view of predicting without utilizing (or fitting) experimental data. Of particular interest are heuristic approaches that provide prediction of single-phase compositions, more rigorous approaches that tackle the thermodynamics from a more fundamental point of view, and simulation approaches that provide further insight into the behaviors. This paper covers cases of all three of these, in order to examine the strengths and weaknesses of each approach, and to indicate directions where these may be utilized and improved upon. Of particular interest is moving beyond “which composition may form a solid solution,” to recognizing the importance of underlying thermodynamic realities that affect the temperature- and composition-dependent transformations of these materials.

36 MATERIALS SCIENCE↗

Impact of Surface Curvature on Dose Delivery in Intraoperative High-Dose-Rate Brachytherapy

In intraoperative high-dose-rate (IOHDR) brachytherapy, a 2-dimensional (2D) geometry is typically used for treatment planning. The assumption of planar geometry may cause serious errors in dose delivery for target surfaces that are, in reality, curved. A study to evaluate the magnitude of these errors in clinical practice was undertaken. Cylindrical phantoms with 6 radii (range: 1.35-12.5 cm) were used to simulate curved treatment geometries. Treatment plans were developed for various planar geometries and were delivered to the cylindrical phantoms using catheters inserted into Freiburg applicators of varying dimension. Dose distributions were measured using radiographic film. In comparison to the treatment plan (for a planar geometry), the doses delivered to prescription points were higher on the concave side of the geometry, up to 15% for the phantom with the smallest radius. On the convex side of the applicator, delivered doses were up to 10% lower for small treated areas ({<=} 5 catheters) but, interestingly, the dose error was negligible for large treated areas (>5 catheters). Our measurements have shown inaccuracy in dose delivery when the original planar treatment plan is delivered with a curved applicator. Dose delivery errors arising from the use of planar treatment plans with curved applicators may be significant.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Pelvic Phantom for Modeling Internal Organ Motions

A pelvic phantom was developed for use in testing image-guided radiation therapy (IGRT) and adaptive applications in radiation therapy (ART) with simulating the anterior-posterior internal organ motions during prostate radiotherapy. Measurements could be done with an ionization chamber (IC) in the simulated prostate. The rectum was simulated by air-equivalent material (AEM). The volume superior to the IC placement was considered as the bladder. The extension of AEM volume could be varied. The vertical position of the IC placement could be shifted by {+-}1 cm to simulate the prostate motion parallel to the changes in bladder volume. The reality of the simulation was inspected. Three-millimeter-slice-increment computed tomography (CT) scans were taken for irradiation planning. The structure set was adapted to the phantom from a treated patient. Planning target volume was delineated according to the RTOG 0126 study. IMRT and 3D conformal radiation therapy (3D-CRT) plans were made. Prostate motion and rectum volume changes were simulated in the phantom. IC displacement was corrected by phantom shifting. The delivered dose was measured with IC in 7 cases using intensity-modulated radiation therapy (IMRT) and 3D-CRT fractions, and single square-shaped beams: anteroposterior (AP), posteroanterior (PA), and lateral (LAT). Variations from the calculated doses were slightly below 1% at IMRT and around 1% at 3D-CRT; below 4.5% at square AP beam; up to 9% at square PA beam; and around 0.5% at square LAT beam. Other authors have already shown that by using planning systems and ultrasonic and cone beam CT guidance, correction of organ motions in a real patient during prostate cancer IGRT does not have a significant dosimetric effect. The inspection of our phantom-as described here-ended with similar results. Our team suggested that our model is sufficiently realistic and can be used for IGRT and ART testing.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance

To compare the doses calculated using the BrainLAB pencil beam (PB) and Monte Carlo (MC) algorithms for tumors located in various sites including the lung and evaluate quality assurance procedures required for the verification of the accuracy of dose calculation. The dose-calculation accuracy of PB and MC was also assessed quantitatively with measurement using ionization chamber and Gafchromic films placed in solid water and heterogeneous phantoms. The dose was calculated using PB convolution and MC algorithms in the iPlan treatment planning system from BrainLAB. The dose calculation was performed on the patient's computed tomography images with lesions in various treatment sites including 5 lungs, 5 prostates, 4 brains, 2 head and necks, and 2 paraspinal tissues. A combination of conventional, conformal, and intensity-modulated radiation therapy plans was used in dose calculation. The leaf sequence from intensity-modulated radiation therapy plans or beam shapes from conformal plans and monitor units and other planning parameters calculated by the PB were identical for calculating dose with MC. Heterogeneity correction was considered in both PB and MC dose calculations. Dose-volume parameters such as V95 (volume covered by 95% of prescription dose), dose distributions, and gamma analysis were used to evaluate the calculated dose by PB and MC. The measured doses by ionization chamber and EBT GAFCHROMIC film in solid water and heterogeneous phantoms were used to quantitatively asses the accuracy of dose calculated by PB and MC. The dose-volume histograms and dose distributions calculated by PB and MC in the brain, prostate, paraspinal, and head and neck were in good agreement with one another (within 5%) and provided acceptable planning target volume coverage. However, dose distributions of the patients with lung cancer had large discrepancies. For a plan optimized with PB, the dose coverage was shown as clinically acceptable, whereas in reality, the MC showed a systematic lack of dose coverage. The dose calculated by PB for lung tumors was overestimated by up to 40%. An interesting feature that was observed is that despite large discrepancies in dose-volume histogram coverage of the planning target volume between PB and MC, the point doses at the isocenter (center of the lesions) calculated by both algorithms were within 7% even for lung cases. The dose distributions measured with EBT GAFCHROMIC films in heterogeneous phantoms showed large discrepancies of nearly 15% lower than PB at interfaces between heterogeneous media, where these lower doses measured by the film were in agreement with those by MC. The doses (V95) calculated by MC and PB agreed within 5% for treatment sites with small tissue heterogeneities such as the prostate, brain, head and neck, and paraspinal tumors. Considerable discrepancies, up to 40%, were observed in the dose-volume coverage between MC and PB in lung tumors, which may affect clinical outcomes. The discrepancies between MC and PB increased for 15 MV compared with 6 MV indicating the importance of implementation of accurate clinical treatment planning such as MC. The comparison of point doses is not representative of the discrepancies in dose coverage and might be misleading in evaluating the accuracy of dose calculation between PB and MC. Thus, the clinical quality assurance procedures required to verify the accuracy of dose calculation using PB and MC need to consider measurements of 2- and 3-dimensional dose distributions rather than a single point measurement using heterogeneous phantoms instead of homogenous water-equivalent phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

TENDL: Complete Nuclear Data Library for Innovative Nuclear Science and Technology

The TENDL library is now established as one of the major nuclear data libraries in the world, striving for completeness and quality of nuclear data files for all isotopes, evaluation methods, processing and applied performance. To reach this status, some basic principles have been applied which sets it apart from other libraries: reproducible dedicated evaluations when differential data are available, through determination of nuclear models implemented in TALYS and their parameters, completeness (with or without experimental data), format and processing standardization, automation of production and reproducibility. In this paper, we will outline how such an approach has become a reality, and recall some of the past successes since the first TENDL release in 2008. Next, we will demonstrate the performance of the latest TENDL releases for different application fields, as well as new approaches for uncertainty quantification based on Bayesian inference methods and possible differential and integral adjustments. Also, current limitations of the library performances due to modelling and needs for new and more precise experimental data will be outlined.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Machine learning from RANS and LES to inform coarse grid simulations

Nuclear system thermal hydraulic analysis has historically relied on computationally inexpensive 1D codes. However, such tools are unable to capture multiscale multidimensional effects in large nuclear reactor enclosures. On the other hand, simulations with higher fidelity can be too expensive for such purposes. One of the ways to reduce computational cost is to perform simulations on a coarse grid, which, unfortunately, introduces large discretization errors. In this paper, two high-to-low data-driven approaches are investigated: (1) a coarse grid turbulence model to predict eddy viscosity and (2) correction of errors in coarse grid velocity fields. The approaches aim to reduce grid- and turbulence model-induced errors in coarse grid Reynolds-averaged Navier–Stokes (RANS) simulations. Two sources of high-fidelity data, RANS and large eddy simulations (LES), are explored. To extract the eddy viscosity from the LES data, an inverse optimization problem is solved. However, the LES eddy viscosity is shown to be comparable to the RANS eddy viscosity in terms of error reduction. Therefore, the directly available RANS eddy viscosity was used to develop a coarse grid data-driven turbulence model. Additionally, error correction in velocity is used to reduce the remaining uncertainties and bring the results closer to reality. In conclusion, the performance of the frameworks is demonstrated for a scaled upper plenum of a gas-cooled reactor facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modelling twentieth century global ocean circulation and iceberg flux at 48°N: implications for west Greenland iceberg discharge

We have used a coupled ocean–iceberg model to study the variation in global ocean circulation and North Atlantic iceberg flux from 1900 to 2008. The latter component of the study focused particularly on Greenland icebergs feeding into the Labrador Current and past Newfoundland. The model was forced with daily heat, freshwater and wind fluxes from the Twentieth Century Reanalysis. The reanalysis heat fluxes were shown to be offset from the, shorter, NCEP reanalysis and a grid-point correction was applied to this component of the forcing. The model produces a generally realistic ocean circulation, although with an enhanced Atlantic Meridional Overturning largely due to the forcing. The modelled iceberg flux at 48°N is well correlated with the long-term observed flux when using a modelled iceberg discharge that varies in a similar fashion to the highly variable observed flux at 48°N. From this model we infer changes in the spatial and temporal variability of iceberg calving from western Greenland. During the first third of the twentieth century the majority of modelled icebergs reaching 48°N derive from southern Greenland, while only after 1930 is the traditional perspective of a majority of such icebergs originating from Baffin Bay consistent with model results. Decadal-scale changes in the dominant regional sources are found, with oscillations between western Greenland and northern Baffin Bay. The latter origin was modelled to be most important in the last third of the twentieth century, although west Greenland sources have increased in importance in recent years. The model correctly reproduces the pronounced late spring peak in flux at 48°N for southern Greenland icebergs, but has an approximately six month offset for icebergs from Baffin Bay, most likely due to resolution issues leading to model icebergs not being delayed in shallow coastal waters, whereas in reality they may be grounded for some time or trapped in coastal sea-ice.

54 ENVIRONMENTAL SCIENCES↗

Implementation of new mixture rules has a substantial impact on combustion predictions for H 2 and NH 3

Complex-forming reactions comprise a substantial fraction of all important combustion reactions and are central to combustion behavior. Despite being often called “pressure-dependent” reactions, their rate constants depend on not only the pressure but also the composition. While modern combustion codes allow arbitrarily high accuracy in treating pressure dependence, recent work has consistently demonstrated dramatic failures of essentially all available treatments of mixture dependence. In situations where mixture dependence is treated at all, it is inevitably treated through specification of pressure-dependent rate constants for a set of pure bath gases, which are then combined to estimate the rate constant in a mixture via a “mixture rule.” While there had been a generally unquestioning confidence in these mixture rules, they had, in reality, been scarcely tested until the last decade, when comparisons against master equation calculations revealed order-of-magnitude errors for important pressure-dependent reactions. New mixture rules, based on the reduced pressure, have recently been proposed and shown to reproduce master equation calculations for broad classes of complex-forming reactions very accurately. Here, in this work, we present an implementation of one such new mixture rule (“LMR-R”) in Cantera and then use it to enable simulations that use new high-accuracy ab initio data for individual bath gases (for the first time, since codes previously could not accommodate the complex bath gas dependence). Demonstrations focus on combustion of H 2 and NH 3 , where (1) high-accuracy ab initio data are available and (2) the impact is expected to be large due to the high fractions of efficient colliders (e.g., H 2 O and NH 3 ) in the burned and unburned gases. Indeed, we find the impact of this treatment to be substantial and may explain previous modeling difficulties for these important carbon-free fuels, particularly for NH 3 , whose extraordinarily high third-body efficiency (~20) is often omitted from kinetic models.

Ammonia↗