A New Market for Terrestrial Single-Event Effects: Autonomous Vehicles

ISO-26262, the road vehicle functional safety standard, underwent a major overhaul that was released in December 2018. Radiation effects, and single-event effect (SEE) hazards in particular, play an important role in autonomous vehicle safety. This connection will only increase as the level of driving automation goes from "hands off," to "eyes off," to "mind off." This translates to increased coupling with space climate and weather in addition to other traditional terrestrial radiation sources like thorium and uranium contamination in process and packaging materials. We will focus on autonomous vehicle radiation effects and present both benefits and challenges to the space weather and radiation engineering communities.

Autonomous Vehicles↗

Imaging method for monitoring delivery of high dose rate brachytherapy

A method for in-situ monitoring both the balloon/cavity and the radioactive source in brachytherapy treatment utilizing using at least one pair of miniature gamma cameras to acquire separate images of: 1) the radioactive source as it is moved in the tumor volume during brachytherapy; and 2) a relatively low intensity radiation source produced by either an injected radiopharmaceutical rendering cancerous tissue visible or from a radioactive solution filling a balloon surgically implanted into the cavity formed by the surgical resection of a tumor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shielding Design for Prototype Generation-IV Sodium-Cooled Fast Reactor

A Prototype Generation-IV Sodium-cooled Fast Reactor (PGSFR) with 150 MWe power rating is being developed jointly by the Korea Atomic Energy Research Institute (KAERI) and Argonne National Laboratory (ANL). KAERI is responsible for the overall project with the ANL contributions integrated into the KAERI activities. Shielding concept of PGSFR was developed to ensure that the safety limit on internal structural damage and working personnel received dose is not exceeded. The first part evaluated the Displacement Per Atoms (DPA) and fast neutron fluence on the structures inside the reactor vessel, such as lower grid, Upper Internal Structure (UIS), barrel, Redan, and reactor vessels. The analysis determined the thickness of shields required to satisfy the DPA and fast fluence limit. The second part of the shielding analysis evaluated the radiation dose rate above the reactor head due to the primary sodium activation inside the reactor vessel. The analysis determined the necessary thickness of reactor head and additional shield to ensure that the dose rate received by personnel working on top of the reactor is below the safety limit. The last part of the shielding analysis investigated the dose rate received by personnel working near the secondary loop. The secondary sodium is activated inside the Intermediate heat exchanger (IHX). The activated secondary sodium flows out of the reactor vessel and emits high energy photons along the way. The shielding designs both inside the reactor vessel and around the pipes of the secondary loop were investigated. The shielding concept for the PGSFR was developed to minimize radiation exposure to plant personnel and the irradiation damage of the internal structural components. The damage of the internal structural components are mainly due to the loss of the ductility by the neutron irradiation, and the activated gammas of primary and secondary sodium coolants are the major radiation sources that are required to be shielded. Thicker and denser shielding structures are favorable to reduce the radiation dose and protect personnel who work in the plant; however, which enlarges the in-vessel space to accommodate the shielding structures. Thus, in order to install the shielding structures in a reasonable reactor to satisfy the DPA or dose rate limit size, the PGSFR shielding parameters were determined from the sensitivity study, which includes the compositions of the shielding materials and dimensions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of Gamma Background Radiation Digital Twin with Machine Learning Algorithms: Application of Unsupervised Machine Learning to Detection of Anomalies and Nuisances in Gamma Background Radiation Environmental Screening Data

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to explore unsupervised machine learning (ML) algorithms for development of a digital twin of gamma radiation background, and for detection and identification of weak nuisances and anomalies events in the presence of highly fluctuating background. In one segment of work, we developed a gamma background estimation model using a Longshort term memory (LSTM) network for one-step CPS time series prediction. The LSTM model was validated with two data sets of measurements from two independent NaI detectors positioned on a mobile platform. The data sets contained background radiation only and no orphan isotope sources. The LSTM model was constructed and tested using data from one of the detectors. Performance of the LSTM model was validate through one-step prediction of CPS time series of another NaI detector without re-training. This approach allows to create a digital twin for nuclear background estimation. Using LSTM, it could be possible to detect a source through subtraction of the estimated counts from the measured background. In another segment of work, we investigated detection of gamma emitting sources in the presence of complex background using unsupervised machine learning. Spectral lines of isotopes are difficult to observe in one-second measurements. Averaging over the entire measurement campaign data set reveals spectral lines of most common background isotopes. Spectral lines of orphan sources, which might appear only in a few measurements during the campaign, will be washed out if averaging is performed over the entire measurement data set. The approach we have explored consists of extracting one-second measurements containing weak spectral features through data clustering. Averaging one-second spectra in a cluster should reveal the presence of anomaly sources. We created two ML models using K-means clustering and Neural Network Self-organizing Map (SOM). Performance of these ML models was benchmarked using search data. One data set contained 137 Cs source, and another dataset contained 131 I source.

54 ENVIRONMENTAL SCIENCES↗

The metrology of spherical shells using synchrotron x ray microtomography

With recent advances in solid state imaging technology and the increasing availability of synchrotron x-ray radiation sources, synchrotron x-ray microtomography is emerging as a nondestructive technique for the evaluation of the structure and composition of small specimens with spatial resolution in the micron range. Synchrotron radiation offers the following advantages over conventional x-ray sources: high brightness, continuous emission which is tunable over a large energy range, faster data collection rates, and a highly collimated beam of large cross section permitting the illumination of large specimens. Synchrotron x-ray microtomography enables the structure of individual spheres to be evaluated in order to reveal the concentricity and sphericity of the internal void and the uniformity of the shell wall in the case of high quality spherical shells for Sandia National Laboratories' Inertial Confinement Fusion project.

Hmelo, Anthony B.↗

A plausible energy source and structure for quasi-stellar objects

If a collision of two large, massive, fast gas clouds occurs, their kinetic energy is converted to radiation in a pair of shock fronts at their interface. The resulting structure is described, and the relevance of this as a radiation source for quasi-stellar objects is considered.

Daltabuit, E.↗

SU-F-T-663: Cerenkov Radiation Enhanced Radiotherapy with Titanium Dioxide Nanoparticle: A Monte Carlo Study

Purpose: A recent publication has shown that by delivering titanium dioxide nanoparticles (titania) as a photosensitizer into tumors, Cerenkov radiation (CR) produced by radionuclides could be used for substantially boosting damage to cancer cells. The present work compares CR production by various clinically relevant radiation sources including internal radionuclides and external beam radiotherapy (EBRT), and provides preliminarily computational results of CR absorption by titania. Methods: 1) Geant4.10.1 was used to simulate ionizing radiation-induced CR production in a 1cm diameter spherical volume using external radiotherapy sources: Varian Clinac IX 6MV and Eldorado {sup 60}Co, both with 10*10 cm{sup 2} field size. In each case the volume was placed at the maximum dose depth (1.5cm for 6MV source and 0.5cm for {sup 60}Co). In addition, {sup 18}F, {sup 192}Ir and {sup 60}Co were simulated using Geant4 radioactive decay models as internal sources. Dose deposition and CR production spectra in 200nm-400nm range were calculated as it is the excitation range of titania. 2) Using 6MV external source, the absorption by titania was calculated via the track length of CR in the spherical volume. The nanoparticle concentration was varied from 0.25 to 5µg/g. Results: Among different radioactive sources, results showed that {sup 18}F induced the highest amount of CR per disintegration, but {sup 60}Co had the highest yield per unit dose. When compared with external sources, 6MV source was shown to be the most efficient for the the same delivered dose. Simulations indicated increased absorption for increasing concentrations, with up to 68% absorption of generated CR for 5µg/g titania concentration. Conclusion: The results demonstrate that 6MV beam is favored with a higher CR yield, compared to radionuclides, and that the use of higher concentrations of titania may increase photosensitization. From the findings, we propose that if sufficiently potent concentrations of titania are delivered to tumors this could substantially boost EBRT.

60 APPLIED LIFE SCIENCES↗

Scoping estimates of the LDEF satellite induced radioactivity

The Long Duration Exposure Facility (LDEF) satellite was recovered after almost six years in space. It was well-instrumented with ionizing radiation dosimeters, including thermoluminescent dosimeters, plastic nuclear track detectors, and a variety of metal foil samples for measuring nuclear activation products. The extensive LDEF radiation measurements provide the type of radiation environments and effects data needed to evaluate and help resolve uncertainties in present radiation models and calculational methods. A calculational program was established to aid in LDEF data interpretation and to utilize LDEF data for assessing the accuracy of current models. A summary of the calculational approach is presented. The purpose of the reported calculations is to obtain a general indication of: (1) the importance of different space radiation sources (trapped, galactic, and albedo protons, and albedo neutrons); (2) the importance of secondary particles; and (3) the spatial dependence of the radiation environments and effects expected within the spacecraft. The calculational method uses the High Energy Transport Code (HETC) to estimate the importance of different sources and secondary particles in terms of fluence, absorbed dose in tissue and silicon, and induced radioactivity as a function of depth in aluminum.

Armstrong, Tony W.↗

The equilibrium-diffusion limit for radiation hydrodynamics

The equilibrium-diffusion approximation (EDA) is used to describe certain radiation-hydrodynamic (RH) environments. When this is done the RH equations reduce to a simplified set of equations. The EDA can be derived by asymptotically analyzing the full set of RH equations in the equilibrium-diffusion limit. Here, we derive the EDA this way and show that it and the associated set of simplified equations are both first-order accurate with transport corrections occurring at second order. Having established the EDA’s first-order accuracy we then analyze the grey nonequilibrium-diffusion approximation and the grey Eddington approximation and show that they both preserve this first-order accuracy. Further, these approximations preserve the EDA’s first-order accuracy when made in either the comoving-frame (CMF) or the lab-frame (LF). And while analyzing the Eddington approximation, we found that the CMF and LF radiation-source equations are equivalent when neglecting O(β 2 ) terms and compared in the LF. Of course, the radiation pressures are not equivalent. It is expected that simplified physical models and numerical discretizations of the RH equations that do not preserve this first-order accuracy will not retain the correct equilibrium-diffusion solutions. As a practical example, we show that nonequilibrium-diffusion radiative-shock solutions devolve to equilibrium-diffusion solutions when the asymptotic parameter is small.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

WE-DE-201-08: Multi-Source Rotating Shield Brachytherapy Apparatus for Prostate Cancer

Purpose: To introduce a novel multi-source rotating shield brachytherapy (RSBT) apparatus for the precise simultaneous angular and linear positioning of all partially-shielded 153Gd radiation sources in interstitial needles for treating prostate cancer. The mechanism is designed to lower the detrimental dose to healthy tissues, the urethra in particular, relative to conventional high-dose-rate brachytherapy (HDR-BT) techniques. Methods: Following needle implantation, the delivery system is docked to the patient template. Each needle is coupled to a multi-source afterloader catheter by a connector passing through a shaft. The shafts are rotated by translating a moving template between two stationary templates. Shaft walls as well as moving template holes are threaded such that the resistive friction produced between the two parts exerts enough force on the shafts to bring about the rotation. Rotation of the shaft is then transmitted to the shielded source via several keys. Thus, shaft angular position is fully correlated with the position of the moving template. The catheter angles are simultaneously incremented throughout treatment as needed, and only a single 360° rotation of all catheters is needed for a full treatment. For each rotation angle, source depth in each needle is controlled by a multi-source afterloader, which is proposed as an array of belt-driven linear actuators, each of which drives a source wire. Results: Optimized treatment plans based on Monte Carlo dose calculations demonstrated RSBT with the proposed apparatus reduced urethral D{sub 1cc} below that of conventional HDR-BT by 35% for urethral dose gradient volume within 3 mm of the urethra surface. Treatment time to deliver 20 Gy with multi-source RSBT apparatus using nineteen 62.4 GBq {sup 153}Gd sources is 117 min. Conclusions: The proposed RSBT delivery apparatus in conjunction with multiple nitinol catheter-mounted platinum-shielded {sup 153}Gd sources enables a mechanically feasible urethra-sparing treatment technique for prostate cancer in a clinically reasonable timeframe.

60 APPLIED LIFE SCIENCES↗

CINDER08 and Scripting Environment for Accelerator Activation Problems - Paper 101

CINDER is a transmutation code, developed originally at the Bettis Atomic Power Laboratory, which predicts induced radioactivity due to either reactor or accelerator-driven radiation sources. The code and associated data libraries have been expanded and improved over the years at Los Alamos National Laboratory. CINDER08 is the latest update in the series and represents a complete rewrite of CINDER, improving it in many areas. Beginning with CINDER90, several Perl scripts were developed to treat multi-cell problems in combination with the radiation transport code MCNPX. These scripts simplified the preparation of CINDER input and made the code much more user-friendly. In concert with the development of CINDER08, these scripting tools have also been updated. The script developers are intensive users of CINDER and had significant input into the development of CINDER08. CINDER08, through use of these scripts, also works with output from MCNP5, which is useful for problems that do not require the extended particle capabilities of MCNPX and do not require particle energies outside of the tabular physics regime, and with MCNP6. A new version of CINDER, CINDER08, incorporates many improvements to the coding and the data libraries. Updated versions of scripting tools improve the code's usability and simplify the use of CINDER output as the basis of gamma source terms for subsequent calculations. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric Benefit of a New Ophthalmic Radiation Plaque

Purpose: To determine whether the computed dosimetry of a new ophthalmic plaque, EP917, when compared with the standard Collaborative Ocular Melanoma Study (COMS) plaques, could reduce radiation exposure to vision critical structures of the eye. Methods and Materials: One hundred consecutive patients with uveal melanoma treated with COMS radiation plaques between 2007 and 2010 were included in this study. These treatment plans were generated with the use of Bebig Plaque Simulator treatment-planning software, both for COMS plaques and for EP917 plaques using I-125. Dose distributions were calculated for a prescription of 85 Gy to the tumor apex. Doses to the optic disc, opposite retina, lens, and macula were obtained, and differences between the 2 groups were analyzed by standard parametric methods. Results: When compared with the COMS plaques, the EP917 plaques used fewer radiation seeds by an average difference of 1.94 (P<.001; 95% confidence interval [CI], -2.8 to -1.06) and required less total strength of radiation sources by an average of 17.74 U (air kerma units) (P<.001; 95% CI, -20.16 to -15.32). The total radiation doses delivered to the optic disc, opposite retina, and macula were significantly less by 4.57 Gy, 0.50 Gy, and 11.18 Gy, respectively, with the EP917 plaques vs the COMS plaques. Conclusion: EP917 plaques deliver less overall radiation exposure to critical vision structures than COMS treatment plaques while still delivering the same total therapeutic dose to the tumor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Self-organization of cosmic radiation pressure instability

Under some circumstances the absorption of radiation momentum by an absorbing medium opens the possibility of a dynamical instability, sometimes called 'mock gravity'. Here, a simplified abstract model is studied in which the radiation source is assumed to remain spatially uniform, there is no reabsorption or reradiated light, and no forces other than radiative pressure act on the absorbing medium. It is shown that this model displays the unique feature of being not only unstable, but also self-organizing. The structure approaches a statistical dynamical steady state which is almost independent of initial conditions. In this saturated state the absorbers are concentrated in thin walls around empty bubbles; as the instability develops the big bubbles get bigger and the small ones get crushed and disappear. A linear analysis shows that to first order the thin walls are indeed stable structures. It is speculated that this instability may play a role in forming cosmic large-scale structure.

Hogan, Craig J.↗

Radiation Dose Testing on Juno High Voltage Cables

The Juno mission to Jupiter will have a highly elliptical orbit taking the spacecraft through the radiation belts surrounding the planet. During these passes through the radiation belts, the spacecraft will be subject to high doses of radiation from energetic electrons and protons with energies ranging from 10 keV to 1 GeV. While shielding within the spacecraft main body will reduce the total absorbed dose to much of the spacecraft electronics, instruments and cables on the outside of the spacecraft will receive much higher levels of absorbed dose. In order to estimate the amount of degradation to two such cables, testing has been performed on two coaxial cables intended to provide high voltages to three of the instruments on Juno. Both cables were placed in a vacuum of 5x10(exp -6) torr and cooled to -50(deg)C prior to exposure to the radiation sources. Measurements of the coaxial capacitance per unit length and partial discharge noise floor indicate that increasing levels of radiation make measurable but acceptably small changes to the F EP Teflon utilized in the construction of these cables. In addition to the radiation dose testing, observations were made on the internal electrostatic charging characteristics of these cables and multiple discharges were recorded.

partial discharge↗

Radiation Dose Testing on Juno High Voltage Cables

The Juno mission to Jupiter will have a highly elliptical orbit taking the spacecraft through the radiation belts surrounding the planet. During these passes through the radiation belts, the spacecraft will be subject to high doses of radiation from energetic electrons and protons with energies ranging from 10 keV to 1 GeV. While shielding within the spacecraft main body will reduce the total absorbed dose to much of the spacecraft electronics, instruments and cables on the outside of the spacecraft will receive much higher levels of absorbed dose. In order to estimate the amount of degradation to two such cables, testing has been performed on two coaxial cables intended to provide high voltages to three of the instruments on Juno. Both cables were placed in a vacuum of 5x10-6 torr and cooled to -50 C prior to exposure to the radiation sources. Measurements of the coaxial capacitance per unit length and partial discharge noise floor indicate that increasing levels of radiation make measurable but acceptably small changes to the F EP Teflon utilized in the construction of these cables. In addition to the radiation dose testing, observations were made on the internal electrostatic charging characteristics of these cables and multiple discharges were recorded.

Juno↗

Induction of Cell Death through Alteration of Oxidants and Antioxidants in Epithelial Cells Exposed to High Energy Protons

Radiation affects several cellular and molecular processes including double strand breakage, modifications of sugar moieties and bases. In outer space, protons are the primary radiation source which poses a range of potential health risks to astronauts. On the other hand, the use of proton radiation for tumor radiation therapy is increasing as it largely spares healthy tissues while killing tumor tissues. Although radiation related research has been conducted extensively, the molecular toxicology and cellular mechanisms affected by proton radiation remain poorly understood. Therefore, in the present study, we irradiated rat epithelial cells (LE) with different doses of protons and investigated their effects on cell proliferation and cell death. Our data showed an inhibition of cell proliferation in proton irradiated cells with a significant dose dependent activation and repression of reactive oxygen species (ROS) and antioxidants, glutathione and superoxide dismutase respectively as compared to control cells. In addition, apoptotic related genes such as caspase-3 and -8 activities were induced in a dose dependent manner with corresponding increased levels of DNA fragmentation in proton irradiated cells than control cells. Together, our results show that proton radiation alters oxidant and antioxidant levels in the cells to activate apoptotic pathway for cell death.

Ramesh, Govindarajan↗

Modeling Ionizing Radiation for Spaceflight Dynamic Radioisotope Power Systems

This paper presents methods, simulations, and analyses for spaceflight ionizing radiation exposures to three dynamic radioisotope power systems(DRPSs). The specific systems being investigated are part of an open solicitation by the National Aeronautics and Space Administration (NASA) and the US Department of Energy (DOE)to develop DRPS convertor technologies. The analyses include ionizing radiation sources from PuO2andgalactic cosmic rays (GCRs) over notional 20-year mission architectures with optional 10-year exposures from Jovian radiation environments. Total integrated doses to various components are calculated and compared to known material degradation thresholds in the open literature. Based on the findings, certain material trades are recommended for Jovian and non-Jovian mission architectures based solely on ionizing radiation. However, consideration is given to known and unknown synergistic degradation effects(i.e., radiation in combination with heat, pressure, or outgassing)that may be relevant to these systems and are not captured in these analyses.

Models↗

Apparatus and method for phase fronts based on superluminal polarization current

An apparatus and method for a radiation source involving phase fronts emanating from an accelerated, oscillating polarization current whose distribution pattern moves superluminally (that is, faster than light in vacuo). Theoretical predictions and experimental measurements using an existing prototype superluminal source show that the phase fronts from such a source can be made to be very complex. Consequently, it will be very difficult for an aircraft imaged by such a radiation to detect where this radiation has come from. Moreover, the complexity of the phase fronts makes it almost impossible for electronics on an aircraft to synthesize a rogue reflection. A simple directional antenna and timing system should, on the other hand, be sufficient for the radar operators to locate the aircraft, given knowledge of their own source's speed and modulation pattern.

47 OTHER INSTRUMENTATION↗