Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Enhancement of efficiency in the use of light for cultivation of plants in controlled ecological systems

The problems of plant cultivation with the use of artificial lighting are related to energetics and, initially, to the lack of effective sources for photosynthesis, secondly to the necessity to supply a system with a considerable power in the form of light energy and to remove transformed thermal energy, and finally to economic considerations. These problems are solved by three ways: by the choice of effective radiation sources, design approaches, and technological methods of cultivation. Here we shall consider the first two ways.

Mashinsky, A. L.↗

Empirical Refinement of the GADRAS Detector Response Function

The Gamma Detector Response and Analysis Software (GADRAS) was augmented to enable empirical refinement of the Detector Response Function (DRF) for gamma-ray detectors. This capability is included in GADRAS starting with Version 18.8.2, which was released in February 2019 Empirical refinement enables improved computational accuracy for gamma-ray spectra when detectors exhibit characteristics that are essentially unique to a particular sensor. This report discusses how to perform the empirical refinement, and examples are presented for the following scenarios where empirical refinement is appropriate: Large plastic scintillators, which are generally composed of polyvinyl toluene (PVT), often exhibit low-energy peaks that are not associated with incident gamma rays. Regardless of whether they are artifacts produced by poor light collection or pulse processing methods, accurate spectral synthesis requires replication of these features; Some detectors, particularly those using Silicon Photomultipliers (SiPM), exhibit energy shifts of Compton edges and escape peaks relative to the same scintillator material attached to a photomultiplier tube. Empirical refinement compensates for these effects, which derive from nonlinearities in the detector response; The change in the DRF as a function of displacement of the source relative to the detector axis cannot always be replicated adequately using only the few shielding parameters that are used by the response function. Empirical refinement enables improved accuracy for computation of spectra during linear transits or when the detector is close to a large radiation source. This is a particularly important consideration for collimated detectors; and, Gamma-ray imagers exhibit complex relationships between spectral response and spatial locations. Empirical refinement enables substantial improvement of the DRF accuracy for imagers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Early Lab scientists had questions, Plastic Man gave them answers

He was a willing subject in countless scientific experiments, a superstar of health physics, as well as a favorite photo prop -- and not just around Halloween time. He was Plastic Man. Beginning in the mid-1950s, the Lab (then called Los Alamos Scientific Laboratory) often relied on several life-sized synthetic test subjects to avoid experimenting on people. In the early days of the Laboratory, not much was known about how different radioisotopes interacted with the human body and how much it absorbed from different radiation sources. Answering queries like these is where Plastic Man came in. For example, during the 1950s and 1960s, the Lab was tasked with developing nuclear rockets for space exploration under the Rover Program. One of the concerns was how astronauts might be affected when exposed to radiation from these rocket engines. So, the Lab’s health group set up an experiment in which Plastic Man was placed in close proximity to an experimental Rover nuclear rocket engine. Running experiments like this using Plastic Man kept humans safer. How life-like was he? There were actually two variations of Plastic Man. Both had hard plastic exteriors, but one of the models encased a real human skeleton. They also had movable joints and simulated organs, such as a liver, a spleen, kidneys, lungs and a thyroid. Although Plastic Man in its entirety was used in experiments, much of the data collected were from research conducted inside on these replicated organs. In time, technology advanced and Plastic Man was able to retire from the Lab. He found a new home in 1964 as a display at the Laboratory’s science museum, and is sometimes displayed today in the Bradbury Science Museum in downtown Los Alamos.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Generation of straight and curved hollow plasma channels by laser-generated nonlinear wakefields and studies of ultra-intense laser pulse guiding

We report on a study of highly controllable, quasi-static hollow plasma channels generated by ion motion following a laser–plasma interaction via numerical simulations. These channels are generated by ion motion in a nonlinear wakefield, which has an asymmetry between focusing and defocusing periods. Such plasma channels, driven by a fs duration, 100 TW level laser pulse, have the capability to guide more powerful laser pulses. Moreover, we show that curved plasma channels can be generated in a transverse density gradient plasma and alloptical guiding of a second, significantly more powerful laser pulse in such a curved plasma channel. This mechanism may be useful for creating plasma optics for multi-stage TeV laser plasma accelerators and compact synchrotron radiation sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Selection of CVD Diamond Crystals for X-ray Monochromator Applications Using X-ray Diffraction Imaging

A set of 20 single crystal diamond plates synthesized using chemical vapor deposition (CVD) was studied using X-ray diffraction imaging to determine their applicability as side-bounce (single-reflection) Laue monochromators for synchrotron radiation. The crystal plates were of optical grade (as provided by the supplier) with (001) nominal surface orientation. High dislocation density was found for all samples. Distortions in the crystal lattice were quantified for low-index Laue reflections of interests using rocking curve topography. Maps of effective radius of curvature in the scattering plane were calculated using spline interpolation of the rocking curve peak position across the studied plates. For several selected plates, nearly flat regions with large effective radius of curvature were found (R 0 ≳ 30 - 70 m, some regions as large as 1 × 4 mm 2 ). The average width of the rocking curve for these regions was found to be about 150 μ rad (r.m.s.). These observations suggest that the selected CVD diamond plates could be used as intermediate-bandwidth monochromators refocusing the radiation source to a specific location downstream with close to 1:1 distance ratio.

36 MATERIALS SCIENCE↗

Investigation of radiation keeping property of barite coated cloth via image processing method

Preservative clothes which are able to absorb radiation beam are needed not only for saving people working at radioactive environment but also for saving others from natural and man-made radiation sources we are exposed in daily life. Barite is a mineral which can be used for armour plating because of high atomic numbered element barium constituent of barite. In this study, armour plating property of barite was applied to fabrics. Barite coated fabric having characteristic of keeping radiation was obtained by penetrating barite on cloth via coating method. Radiation keeping property of fabrics obtained was determined via image processing. The results of experiments showed that barite coated fabrics have blocked radiation more than normal fabrics have done.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of radiation environment on reusable nuclear shuttle system

Parametric tradeoff analyses of a wide spectrum of alternate tank configurations to minimize both primary and secondary, direct and scattered radiation sources emanating from the NERVA are reported. The analytical approach utilizing point kernel techniques is described and detailed data are presented on the magnitude of neutron/gamma doses for different locations. Single-tank configurations utilizing smaller cone angles and end cap radii were found to minimize integral radiation levels, hence, stage shielding-weight penalties for shuttle missions. Hybrid configurations employing an upper tank with a reduced cone angle and end cap radius result in low integral payload doses primarily due to the increased separation distance caused by the elongation of the larger capacity upper tank. A preliminary radiation damage assessment is discussed of possible reusable nuclear shuttle materials, components, and subsystems, and the possible effects of the radiation environment on various phases of RNS mission operations.

Lane, A. G.↗

Implosion dynamics in double planar wire array Z pinches

The double planar wire array (DPWA) Z pinch is a highly efficient radiation source with unique implosion dynamics and precursor formations. The inductively divided current successively ablates the wires and injects the material to the interior of the array. Three uniquely imploding DPWA load types were identified and classified according to the critical load parameter: low, intermediate, or high aspect ratio. Radiation pulse shaping was obtained from secondary precursors: off-axis mass carrying high current densities during the implosion phase. Time-gated EUV spectroscopy of off-axis mass accumulations is used to assess a 60 eV electron temperature prior to the implosion phase. These structures are shown to form by a different mechanism than the secondary precursors. High yields, compact size, and shaped radiation pulses merit further consideration of the DPWA as a candidate for inertial confinement fusion research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synchrotron X-Ray Microprobe and Microspectroscopy Research in Low Temperature Geochemistry

The project focuses on low temperature geochemistry applications of X-ray fluorescence microprobes primarily at the National Synchrotron Light Source (NSLS-I) but also at National Synchrotron Light Source II (NSLS-II), Brookhaven National Laboratory (BNL), Upton, NY. The microprobes can be used to determine the composition, structure, oxidation state, and bonding characteristics of earth materials with trace element sensitivity and micrometer spatial resolution. Investigators on this project are members of the Center for Advanced Radiation Sources (CARS) at the University of Chicago, a team that developed and managed the highly-successful microprobe beamline X26A at the National Synchrotron Light Source I (NSLS-I) at BNL from the 1980s until the closing of NSLS-I in September 2014. The closing of NSLS-I coincided with the start-up of the newly-constructed, 3 rd -generation synchrotron NSLS-II, also at BNL. During the course of this project, a subaward was let to the University of Kentucky to partially support the efforts of a technician at the beamlines.

36 MATERIALS SCIENCE↗

Experimental measurement and computer analysis of stray radiation in a telescope

A description is presented of an experimental measurement system for the study of the stray radiation performance of a 50-cm aperture astronomical telescope model. The model incorporates a very high performance baffle system. To simulate the space environment of the actual orbiting telescope, the telescope model was placed in a vacuum chamber. The stray radiation source for the experiment was a ruby laser system. A photomultiplier tube was used for the detector. A minicomputer system was used to control the experiment and to gather and process the data. A computer program was used to model the telescope baffle system. Experimentally and analytically determined stray radiation attenuation data are compared.

Hunt, G. H.↗

Localization-Based detection under network losses

We consider a networked system of sensors that measure the intensity of a source amidst background inside a two-dimensional monitoring area. The source intensity decays away from it, and the corresponding sensor measurements are random with a parameter determined by the intensity at sensor location. The detection problem is to infer the presence of a source based on measurements. Under a statistical independence condition, we show that a detection method based on maximum likelihood fuser performs below the individual sensors in presence of network losses. It has been previously shown that the localization of a source using measurements from multiple sensors leads to an improved detection, thereby establishing the effectiveness of a network over single or co-located sensors. We show that the communication losses degrade such network detection performance, particularly to levels below that of a single sensor under heavy losses. Under fairly general conditions on the source intensity decay functions and underlying measurement distributions, we quantify the loss of performance of the localization-based detection as a function of loss rate and packing number of state space. We present simulation and experimental results that illustrate the performance degradations due to network losses in detecting radiation sources.

cyber-physical networks↗

Probing extreme states of matter using ultra-intense x-ray radiation

Extreme states of matter, that is, matter at extremes of density (pressure) and temperature, can be created in the laboratory either statically or dynamically. In the former, the pressure–temperature state can be maintained for relatively long periods of time, but the sample volume is necessarily extremely small. When the extreme states are generated dynamically, the sample volumes can be larger, but the pressure–temperature conditions are maintained for only short periods of time (ps to μs). In either case, structural information can be obtained from the extreme states by the use of x-ray scattering techniques, but the x-ray beam must be extremely intense in order to obtain sufficient signal from the extremely-small or short-lived sample. In this article I describe the use of x-ray diffraction at synchrotrons and XFELs to investigate how crystal structures evolve as a function of density and temperature. After a brief historical introduction, I describe the developments made at the Synchrotron Radiation Source in the 1990s which enabled the almost routine determination of crystal structure at high pressures, while also revealing that the structural behaviour of materials was much more complex than previously believed. I will then describe how these techniques are used at the current generation of synchrotron and XFEL sources, and then discuss how they might develop further in the future at the next generation of x-ray lightsources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of Attila and MCNP computational methods for dose and exposure estimation

Radiation transport calculations are often used to estimate dose or exposure to components and personnel surrounding a radiation source. The sources for these calculations are decaying radionuclides within various nuclear materials. Historically, dose calculations use MCNP (Monte Carlo N-Particle) transport code as the primary particle transport tool without a secondary computational tool to validate the results from the MCNP simulations [1]. The goal of this study is to make an independent check of the Monte Carlo solution from MCNP6 Version 6.2.1 with the discrete ordinates solution from Attila 10.2.0 Beta 3. As an example problem for this study, water-filled, stainless-steel vessels, modeled with an unstructured mesh (UM) with both MCNP and Attila [2], are exposed to 252Cf and 60Co point sources. This report also includes a discussion of the limitations of unstructured mesh in a MCNP calculation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sources of black carbon aerosols in South Asia and surrounding regions during the Integrated Campaign for Aerosols, Gases and Radiation Budget (ICARB)

This study examines differences in the surface black carbon (BC) aerosol loading between the Bay of Bengal (BoB) and the Arabian Sea (AS) and identifies dominant sources of BC in South Asia and surrounding regions during March–May 2006 (Integrated Campaign for Aerosols, Gases and Radiation Budget, ICARB) period. A total of 13 BC tracers are introduced in the Weather Research and Forecasting Model coupled with Chemistry to address these objectives. The model reproduced the temporal and spatial variability of BC distribution observed over the AS and the BoB during the ICARB ship cruise and captured spatial variability at the inland sites. In general, the model underestimates the observed BC mass concentrations. However, the model–observation discrepancy in this study is smaller compared to previous studies. Model results show that ICARB measurements were fairly well representative of the AS and the BoB during the pre-monsoon season. Elevated BC mass concentrations in the BoB are due to 5 times stronger influence of anthropogenic emissions on the BoB compared to the AS. Biomass burning in Burma also affects the BoB much more strongly than the AS. Results show that anthropogenic and biomass burning emissions, respectively, accounted for 60 and 37% of the average ± standard deviation (representing spatial and temporal variability) BC mass concentration (1341 ± 2353 ng m -3 ) in South Asia. BC emissions from residential (61%) and industrial (23%) sectors are the major anthropogenic sources, except in the Himalayas where vehicular emissions dominate. We find that regional-scale transport of anthropogenic emissions contributes up to 25% of BC mass concentrations in western and eastern India, suggesting that surface BC mass concentrations cannot be linked directly to the local emissions in different regions of South Asia.

54 ENVIRONMENTAL SCIENCES↗

Study of large adaptive arrays for space technology applications

The research in large adaptive antenna arrays for space technology applications is reported. Specifically two tasks were considered. The first was a system design study for accurate determination of the positions and the frequencies of sources radiating from the earth's surface that could be used for the rapid location of people or vehicles in distress. This system design study led to a nonrigid array about 8 km in size with means for locating the array element positions, receiving signals from the earth and determining the source locations and frequencies of the transmitting sources. It is concluded that this system design is feasible, and satisfies the desired objectives. The second task was an experiment to determine the largest earthbound array which could simulate a spaceborne experiment. It was determined that an 800 ft array would perform indistinguishably in both locations and it is estimated that one several times larger also would serve satisfactorily. In addition the power density spectrum of the phase difference fluctuations across a large array was measured. It was found that the spectrum falls off approximately as f to the minus 5/2 power.

Berkowitz, R. S.↗

Accelerating fissile material detection with a neutron source

A system discriminating fissile material from nonfissile material wherein a digital data acquisition unit collects data at high rate, and processes large volumes of data directly to count neutrons from the unknown source and detect excess grouped neutrons to identify fission. The system includes a Poisson neutron generator for in-beam interrogation of a possible fissile neutron source and inducing neutron emission therefrom, and a DC power supply that exhibits electrical ripple of less than one part per million. A neutron count histogram and Poisson count distribution are overlaid to provide a visual indication of the difference in correlation of natural and induced emitted neutrons from the radiation source to characterize the neutron source as fissile material or non-fissile material.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Accelerating fissile material detection with a neutron source

A method of discriminating fissile material from non-fissile material with a digital data acquisition system that collects data at high rate, and processes large volumes of data directly to count neutrons from the unknown source and detect excess grouped neutrons to identify fission. The system includes a Poisson neutron generator for in-beam interrogation of a possible fissile neutron source and inducing neutron emission therefrom, and a DC power supply that exhibits electrical ripple of less than one part per million. A neutron count histogram and Poisson count distribution are overlaid to provide a visual indication of the difference in correlation of natural and induced emitted neutrons from the radiation source to characterize the neutron source as fissile material or non-fissile material.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam↗