Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION FIELD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

A hybrid Boundary Element Unstructured Transmission-line (BEUT) method for accurate 2D electromagnetic simulation

Time domain electromagnetic simulation tools have the ability to model transient, wide-band applications, and non-linear problems. The Boundary Element Method (BEM) and the Transmission Line Modeling (TLM) method are both well established numerical techniques for simulating time-varying electromagnetic fields. The former surface based method can accurately describe outwardly radiating fields from piecewise uniform objects and efficiently deals with large domains filled with homogeneous media. The latter volume based method can describe inhomogeneous and non-linear media and has been proven to be unconditionally stable. Furthermore, the Unstructured TLM (UTLM) enables modelling of geometrically complex objects by using triangular meshes which removes staircasing and unnecessary extensions of the simulation domain. The hybridization of BEM and UTLM which is described in this paper is named the Boundary Element Unstructured Transmission-line (BEUT) method. It incorporates the advantages of both methods. The theory and derivation of the 2D BEUT method is described in this paper, along with any relevant implementation details. The method is corroborated by studying its correctness and efficiency compared to the traditional UTLM method when applied to complex problems such as the transmission through a system of Luneburg lenses and the modelling of antenna radomes for use in wireless communications. - Graphical abstract:.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

EVIDENCE OF PHOTOEVAPORATION AND SPATIAL VARIATION OF GRAIN SIZES IN THE ORION 114-426 PROTOPLANETARY DISK

Deep Hubble Space Telescope broadband images taken with Advanced Camera for Surveys (ACS) and WFPC2 of the giant ({approx}1000 AU diameter) dark silhouette proplyd 114-426 in the Orion Nebula show that this system is tilted, asymmetric, warped, and photoevaporated. The exquisite angular resolution of ACS allows us to map the distribution of dust grains at the northern translucent edge of the disk, dominated by the photoevaporative flow. Using the Mie theory for standard circumstellar disk grains, we find evidence for a spatial gradient in grain size. The typical dust radius {approx_equal} 0.2-0.7 {mu}m (less than what was reported by previous studies) becomes smaller as the distance from the disk center increases, consistent with the expectations for the dynamic of dust entrained in a gaseous photoevaporative wind. Our analysis of the disk morphology and location within the nebula indicates that this system is photoevaporated by the diffuse radiation field of the Orion Nebula, while being shielded from the radiation coming directly from the central Trapezium stars. We estimate the mass-loss rate from the disk surface and the timescale for total disk dissipation, which turns out to be of the order of 10{sup 4} yr. Such a short time, of the order of 1/100 of the cluster age, indicates that this system is seen on the verge of destruction. This is compatible with the exceptional nature of the disk, namely its combination of huge size and low mass. Finally, we briefly discuss the viability of possible mechanisms that may lead to the peculiar morphology of this system: external UV flux, binary star, and past close encounter.

79 ASTRONOMY AND ASTROPHYSICS↗

Non-coherent continuum scattering as a line polarization mechanism

Line scattering polarization can be strongly affected by Rayleigh scattering at neutral hydrogen and Thomson scattering at free electrons. Often a depolarization of the continuum results, but the Doppler redistribution produced by the continuum scatterers, which are light (hence, fast), induces more complex interactions between the polarization in spectral lines and in the continuum. Here we formulate and solve the radiative transfer problem of scattering line polarization with non-coherent continuum scattering consistently. The problem is formulated within the spherical tensor representation of atomic and light polarization. The numerical method of solution is a generalization of the Accelerated Lambda Iteration that is applied to both the atomic system and the radiation field. We show that the redistribution of the spectral line radiation due to the non-coherence of the continuum scattering may modify the shape of the emergent fractional linear polarization patterns significantly, even yielding polarization signals above the continuum level in intrinsically unpolarizable lines.

79 ASTRONOMY AND ASTROPHYSICS↗

Micrometer-resolved film dosimetry using a microscope in microbeam radiation therapy

Purpose: Microbeam radiation therapy (MRT) is a still preclinical tumor therapy approach that uses arrays of a few tens of micrometer wide parallel beams separated by a few 100 μm. The production, measurement, and planning of such radiation fields are a challenge up to now. Here, the authors investigate the feasibility of radiochromic film dosimetry in combination with a microscopic readout as a tool to validate peak and valley doses in MRT, which is an important requirement for a future clinical application of the therapy. Methods: Gafchromic{sup ®} HD-810 and HD-V2 films are exposed to MRT fields at the biomedical beamline ID17 of the European Synchrotron Radiation Facility (ESRF) and are afterward scanned with a microscope. The measured dose is compared with Monte Carlo calculations. Image analysis tools and film handling protocols are developed that allow accurate and reproducible dosimetry. The performance of HD-810 and HD-V2 films is compared and a detailed analysis of the resolution, noise, and energy dependence is carried out. Measurement uncertainties are identified and analyzed. Results: The dose was measured with a resolution of 5 × 1000 μm{sup 2} and an accuracy of 5% in the peak and between 10% and 15% in the valley region. As main causes for dosimetry uncertainties, statistical noise, film inhomogeneities, and calibration errors were identified. Calibration errors strongly increase at low doses and exceeded 3% for doses below 50 and 70 Gy for HD-V2 and HD-810 films, respectively. While the grain size of both film types is approximately 2 μm, the statistical noise in HD-V2 is much higher than in HD-810 films. However, HD-810 films show a higher energy dependence at low photon energies. Conclusions: Both film types are appropriate for dosimetry in MRT and the microscope is superior to the microdensitometer used before at the ESRF with respect to resolution and reproducibility. However, a very careful analysis of the image data is required. Dosimetry at low photon energies should be performed with great caution due to the energy sensitivity of the films. In this respect, HD-V2 films showed to have an advantage over HD-810 films. However, HD-810 films have a lower statistical noise level. When a higher resolution is required, e.g., for the dosimetry of pencil beam irradiations, noise may render HD-V2 films inapplicable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Iron Beam Characterization Studies at NSRL

The purpose of this note is to describe the radiation field in and around the beam at the NASA Space Radiation Facility (NSRL) at Brookhaven National Laboratory (BNL). NSRL provides ion beams in the energy range from 50 to 1000 MeV per nucleon (up to 2500 MeV for protons). Although the beam dynamics requires that the beam be pure and nearly monoenergetic, by the time the beam has passed through the vacuum window and upstream instrumentation, there are components in the beam other than the requested ion due to fragmentation and scattering of the beam particles and intervening material. We have made measurements of the make-up of the particles that are incident on the target table, and the way they contribute to the total radiation dose.

43 PARTICLE ACCELERATORS↗

Auroral O I /989 A/ and O I /1027 A/ emissions

Rocket observations of the extreme ultraviolet spectrum of the aurora from 550 to 1250 A are presented, and the results for the O I (989 A) and O I (1027 A) multiplets are examined in detail. The intensity of these emissions and the observed anisotropic radiation field are inconsistent with the relative intensity of the branching radiations. Several possible solutions to the problem are discussed, and evidence is presented that suggests the need to lower the branching ratios by several orders of magnitude.

Christensen, A. B.↗

A numerical solution method for acoustic radiation from axisymmetric bodies

A new and very efficient numerical method for solving equations of the Helmholtz type is specialized for problems having axisymmetric geometry. It is then demonstrated by application to the classical problem of acoustic radiation from a vibrating piston set in a stationary infinite plane. The method utilizes 'Green's Function Discretization', to obtain an accurate resolution of the waves using only 2-3 points per wave. Locally valid free space Green's functions, used in the discretization step, are obtained by quadrature. Results are computed for a range of grid spacing/piston radius ratios at a frequency parameter, omega R/c(sub 0), of 2 pi. In this case, the minimum required grid resolution appears to be fixed by the need to resolve a step boundary condition at the piston edge rather than by the length scale imposed by the wave length of the acoustic radiation. It is also demonstrated that a local near-field radiation boundary procedure allows the domain to be truncated very near the radiating source with little effect on the solution.

Caruthers, John E.↗

Observations of Two Non-Standard Grain Components

We discuss evidence for two non-standard grain components: small conglomerates and astronomical iron. The small conglomerates are small, temperature fluctuating grains made up of loosely bound 12 micron emitters (either PAH's or dielectrics). When these grains are exposed to strong UV radiation fields they break apart into smaller pieces. For high UV radiation regimes, such as H II regions, conglomerate grains best explain the reduction of 25 micron emission relative to 12 micron. Astronomical iron was originally proposed for isolated cirrus clouds in order to account for the strength of the 60 micron emission. Within the diffuse ISM, these grains emit at a relatively high equilibrium temperature of 50 K. Our analysis of IRAS data shows the presence of a strong 60 micron emitter in the Lambda Orionis H II region and a component within the Rosette Nebula emitting primarily at 25 micron. Both of these observations can be accommodated by the presence of iron grains within the H II regions.

Shipman, R. F.↗

The Software Element of the NASA Portable Electronic Device Radiated Emissions Investigation

NASA Langley Research Center's (LaRC) High Intensity Radiated Fields Laboratory (HIRF Lab) recently conducted a series of electromagnetic radiated emissions tests under a cooperative agreement with Delta Airlines and an interagency agreement with the FAA. The frequency spectrum environment at a commercial airport was measured on location. The environment survey provides a comprehensive picture of the complex nature of the electromagnetic environment present in those areas outside the aircraft. In addition, radiated emissions tests were conducted on portable electronic devices (PEDs) that may be brought onboard aircraft. These tests were performed in both semi-anechoic and reverberation chambers located in the HIRF Lab. The PEDs included cell phones, laptop computers, electronic toys, and family radio systems. The data generated during the tests are intended to support the research on the effect of radiated emissions from wireless devices on aircraft systems. Both tests systems relied on customized control and data reduction software to provide test and instrument control, data acquisition, a user interface, real time data reduction, and data analysis. The software executed on PC's running MS Windows 98 and 2000, and used Agilent Pro Visual Engineering Environment (VEE) development software, Common Object Model (COM) technology, and MS Excel.

Koppen, Sandra V.↗

Optically stimulated luminescence and thermoluminescence efficiencies for high-energy heavy charged particle irradiation in Al2O3:C

The thermally and optically stimulated luminescence (TL and OSL) response to high energy heavy-charged particles (HCPs) was investigated for two types of Al2O3:C luminescence dosimeters. The OSL signal was measured in both continuous-wave (CW) and pulsed mode. The efficiencies of the HCPs at producing TL or OSL, relative to gamma radiation, were obtained using four different HCPs beams (150 MeV/u 4He, 400 MeV/u 12C, 490 MeV/u 28Si, and 500 MeV/u 56Fe). The efficiencies were determined as a function of the HCP linear energy transfer (LET). It was observed that the efficiency depends on the type of detector, measurement technique, and the choice of signal. Additionally, it is shown that the shape of the CW-OSL decay curve from Al2O3:C depends on the type of radiation, and, in principle, this can be used to extract information concerning the LET of an unknown radiation field. The response of the dosimeters to low-LET radiation was also investigated for doses in the range from about 1-1000 Gy. These data were used to explain the different efficiency values obtained for the different materials and techniques, as well as the LET dependence of the CW-OSL decay curve shape. c2003 Elsevier Ltd. All rights reserved.

Thermoluminescent Dosimetry/instrumentation/method↗

Radiation measured with TEPC and CR-39 PNTDs in low Earth orbit

The radiation impact to astronauts depends strongly on the particles linear energy transfer (LET) and is dominated by high LET radiation. It is important to investigate the LET spectrum for the radiation field in low Earth orbit (LEO) and the influence of radiation on astronauts. The best active dosimeter used for all LET is the tissue equivalent proportional counter (TEPC); the best passive dosimeter used for high LET is CR-39 plastic nuclear track dosimeter (PNTD). TEPC and CR-39 PNTDs were used to investigate the radiation in LEO. LET spectra and radiation quantities were obtained for STS-112 and STS-114 missions with TEPC and CR-39 PNTDs. This paper introduces the operation principles for the two types of dosimeters, presents radiation results measured and compares the results obtained with different dosimeters.

Zhou, D.↗

Feasibility study on real-time {gamma}-ray spectrum / dose measurement system

In recent years, radiations have been used very often especially in the medical field. Radiation protection is carried out properly there. However, the medical staffs sometimes focus not so seriously on their exposure dose, because treatment of patients is the first priority in hospitals. In the past study, there were radiation monitors developed which can indicate the pulse height spectrum and/or dose. However, there were no monitors which can show the gamma-ray energy spectrum and dose at the same time. A monitor, which we design, can estimate the energy spectrum of gamma-rays in the medical atmosphere, with which the dose can be evaluated simultaneously and accurately. The purpose of this study is to develop a spectrometer (monitor) which can show gamma-ray spectrum / dose simultaneously in real time to make the medical staffs understand the risk of radiation precisely and to finally decrease their exposure dose. For this purpose we newly developed a conversion procedure from the measured pulse height spectrum to energy spectrum in real time. The details are also described in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-length Scintillating Fibers for Nuclear Geological Repositories

This research focuses on the usage of plastic scintillating fibers as ruggedized detectors in long-length sections coupled to long-length standard optical fiber segments for the purpose of radiation detection and monitoring. This technology addresses a need for monitoring radiation in difficult-to-access or inaccessible areas, such as monitoring: radioactive waste within geological repositories, nuclear material storage facilities, spent fuel dry storage areas, inaccessible areas within nuclear facilities including reactors and reprocessing facilities, decommissioning of nuclear facilities, and other similar areas. The fiber can be placed along the tunnels of a geological repository to monitor the radiation field along its length. This can detect an increase of radiation due to movement, leakage, or unexpected opening of the containers, as well as decrease in the radiation due to removal of material. These capabilities have been demonstrated at INL’s Radioactive Scrap Waste Facility by successfully detecting the removal of an interim storage containers from the storage area. The poster focuses on explaining the technology and its capability in monitoring deep geological repositories (DGRs), especially in the domain of safety and international safeguards. As more countries consider the development of DGRs, technologies such as the one being presented can help establish continuity of knowledge of the material, maintain public confidence, and ensure safe operation of the facility. Furthermore, the poster looks at the future steps of the technology and its potential role in the international safeguards regime.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Europa Mission Configuration Update to Accommodate Maturing Instrument Designs

A mission to Jupiter’s moon, Europa has been of interest to NASA and JPL since the Galileo mission's magnetometer data predicted the presence of a subsurface ocean. The planned Europa mission would be equipped with a suite of instruments to perform both remote and in-situ sensing, the scope of which ranges from gravity science to characterizing the surface composition, with one of the objectives being to confirm the existence of the subsurface ocean. As the selected instruments mature, the challenge has been to select and refine a spacecraft configuration that is flexible enough to accommodate these changes without degrading the scientific capability of the spacecraft. An increase in instrument volume and power have prompted the growth of spacecraft engineering subsystems, which include the solar arrays and the avionics module. These changes have the potential to cause obstructions to the instrument fields of view, stray light keep-out-zones, and thermal radiative fields of view. Many of these criteria are addressed by the implementation of a dedicated instrument platform. Payloads that are unique to the Europa mission require new approaches to instrument accommodation, such as coupling the ice penetrating radar's radiating elements to the solar array. This paper will discuss these accommodation strategies for the Europa spacecraft to generate a new baseline design.

Gentile, Matthew↗

Radiation Test Results for a MEMS Microshutter Operating at 60 K

The James Webb Space Telescope (JWST), the successor to the Hubble Space Telescope, is due to be launched in 2013 with the goal of searching the very distant Universe for stars that formed shortly after the Big Bang. Because this occurred so far back in time, the available light is strongly red-shifted, requiring the use of detectors sensitive to the infrared portion of the electromagnetic spectrum. HgCdTe infrared focal plane arrays, cooled to below 30 K to minimize noise, will be used to detect the faint signals. One of the instruments on JWST is the Near Infrared Spectrometer (NIRSPEC) designed to measure the infrared spectra of up to 100 separate galaxies simultaneously. A key component in NIRSPEC is a Micro-Electromechanical System (MEMS), a two-dimensional micro-shutter array (MSA) developed by NASA/GSFC. The MSA is inserted in front of the detector to allow only the light from the galaxies of interest to reach the detector and to block the light from all other sources. The MSA will have to operate at 30 K to minimize the amount of thermal radiation emitted by the optical components from reaching the detector array. It will also have to operate in the space radiation environment that is dominated by the MSA will be exposed to a large total ionizing dose of approximately 200 krad(Si). Following exposure to ionizing radiation, a variety of MEMS have exhibited performance degradation. MEMS contain moving parts that are either controlled or sensed by changes in electric fields. Radiation degradation can be expected for those devices where there is an electric field applied across an insulating layer that is part of the sensing or controlling structure. Ionizing radiation will liberate charge (electrons and holes) in the insulating layers, some of which may be trapped within the insulating layer. Trapped charge will partially cancel the externally applied electric field and lead to changes in the operation of the MEMS. This appears to be a general principle for MEMS. Knowledge of the above principle has raised the concern at NASA that the MSA might also exhibit degraded performance because, i) each shutter flap is a multilayer structure consisting of metallic and insulating layers and ii) the movement of the shutter flaps is partially controlled by the application of an electric field between the shutter flap and the substrate (vertical support grid). The whole mission would be compromised if radiation exposure were to prevent the shutters from opening and closing properly. energetic ionizing particles. Because it is located A unique feature of the MSA is that, as outside the spacecraft and has very little shielding, previously mentioned, it will have to operate at temperatures near 30 K. To date, there are no published reports on how very low temperatures (- 30K) affect the response of MEMS devices to total ionizing dose. Experiments on SiO2 structures at low temperatures (80 K) indicate that the electrons generated by the ionizing radiation are mobile and will move rapidly under the application of an external electric field. Holes, on the other hand, that would normally move in the opposite direction through the SiO2 via a "thermal hopping" process, are effectively immobile at low electric fields as they are trapped close to their generation sites. However, for sufficiently large electric fields (greater than 3 MV/cm) holes are able to move through the SiO2. The larger the field, the more rapidly the holes move. The separation of the electrons and holes leads to a reduced electric field within the insulating layer. To overcome this reduction in electric field, a greater external voltage will have to be applied that alters the normal operation of the device. This report presents the results of radiation testing of the MSA at 60 K. The temperature was higher than the targeted temperature because of a faulty electrical interconnect on the test board. Specifically, our goal was to determine whether the MSA would function propey after a TID of 200 krad(Si).

Rapchun, David A.↗

SU-G-BRB-10: New Generation of High Frame-Rate and High Spatial-Resolution EPID QA System for Full-Body MLC-Based Robotic Radiosurgery

Purpose: To systematically investigate an ultra-high spatial-resolution amorphous silicon flat-panel electronic portal imaging device (EPID) for MLC-based full-body robotic radiosurgery geometric and dosimetric quality assurance (QA). Methods: The high frame-rate and ultra-high spatial resolution EPID is an outstanding detector for measuring profiles, MLC-shaped radiosurgery field aperture verification, and small field dosimetry. A Monte Carlo based technique with a robotic linac specific response and calibration is developed to convert a raw EPID-measured image of a radiosurgery field into water-based dose distribution. The technique is applied to measure output factors and profiles for 6MV MLC-defined radiosurgery fields with various sizes ranging from 7.6mm×7.7mm to 100mm×100.1mm and the results are compared with the radiosurgery diode scan measurements in water tank. The EPID measured field sizes and the penumbra regions are analyzed to evaluate the MLC positioning accuracy. Results: For all MLC fields, the EPID measured output factors of MLC-shaped fields are in good agreement with the diode measurements. The mean output difference between the EPID and diode measurement is 0.05±0.87%. The max difference is −1.33% for 7.6mm×7.7mm field. The MLC field size derived from the EPID measurements are in good agreement comparing to the diode scan result. For crossline field sizes, the mean difference is −0.17mm±0.14mm with a maximum of −0.35mm for the 30.8mm×30.8mm field. For inline field sizes, the mean difference is +0.08mm±0.18mm with a maximum of +0.45mm for the 100mm×100.1mm field. The high resolution EPID is able to measure the whole radiation field, without the need to align the detector center perfectly at field center as diode or ion chamber measurement. The setup time is greatly reduced so that the whole process is possible for machine and patient-specific QA. Conclusion: The high spatial-resolution EPID is proved to be an accurate and efficient tool for QA of MLC-equipped robotic radiosurgery system.

60 APPLIED LIFE SCIENCES↗

On an algorithm for analysis of the radiation patterns of dual reflector and segmented reflector antennas

An algorithm has been developed to calculate the radiation patterns of a large reflector antenna for space applications. The algorithm treats each panel in the reflector array as an analytic surface having n-sided polygonal boundaries. The radiation fields for individual panels are computed and stored separately, and then added to yield a uniform radiation pattern for the entire reflector. Numerical methods developed to reduce the overlap of the aperture fields of adjacent panels are described in detail. Calculations of the tangential field components of the aperture plane are carried out based on the principles of geometric optics (GO). Some radiation patterns calculated with the algorithm are compared with patterns produced by other methods, together with measured data for a classical Cassegrain antenna and the calculated patterns are illustrated.

Christodoulou, C. G.↗

Sensitivity of the cherenkov telescope array to the detection of intergalactic magnetic fields

Very high energy (VHE; energy E ≳ 100 GeV) γ-rays originating from extragalactic sources undergo pair production with low-energy photons of background radiation fields. These pairs can inverse-Compton-scatter background photons, initiating an electromagnetic cascade. The spatial and temporal structure of this secondary γ-ray signal is altered as the e{sup +}e{sup −} pairs are deflected in an intergalactic magnetic field (IGMF). We investigate how VHE observations with the future Cherenkov Telescope Array, with its high angular resolution and broad energy range, can potentially probe the IGMF. We identify promising sources and simulate γ-ray spectra over a wide range of values of the IGMF strength and coherence length using the publicly available ELMAG Monte Carlo code. Combining simulated observations in a joint likelihood approach, we find that current limits on the IGMF can be significantly improved. The projected sensitivity depends strongly on the time a source has been γ-ray active and on the emitted maximum γ-ray energy.

79 ASTRONOMY AND ASTROPHYSICS↗