Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Qualification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Structural qualification testing and operational loading on a fiberglass rotor blade for the Mod-OA wind turbine

Fatigue tests were performed on full- and half-scale root end sections, first to qualify the root retention design, and second to induce failure. Test methodology and results are presented. Two operational blades were proof tested to design limit load to ascertain buckling resistance. Measurements of natural frequency, damping ratio, and deflection under load made on the operational blades are documented. The tests showed that all structural design requirements were met or exceeded. Blade loads measured during 3000 hr of field operation were close to those expected. The measured loads validated the loads used in the fatigue tests and gave high confidence in the ability of the blades to achieve design life.

Sullivan, T. L.↗

Component qualification and initial build of the AGT 100 advanced automotive gas turbine

In advance of initial dynamometer testing of the AGT 100 engine, all prime components and subsystems were bench/rig tested. Included were compressor, combustor, turbines, regenerator, ceramic components, and electronic control system. Results are briefly reviewed. Initial engine buildup was completed and rolled-out for test cell installation in July 1982. Shakedown testing included motoring and sequential firing of the combustor's three fuel nozzles.

Johnson, R. A.↗

Shock response spectra variational analysis for pyrotechnic qualification testing of flight hardware

Shock response spectra data from flight certification tests were analyzed to determine envelope variation with respect to mean values in each axis. An overall variation of + or - 8.61 dB or 169 percent exists for the data. This large variation may be attributed to one or more of the following: (1) Instrumentation problems may exist. (2) Variations in the source charge (blasting caps) such as shape or explosive load may exist. (3) Two blasting caps were used to excite the pyrotechnic plate tester. Delay time between charge firings may have varied. The cause or causes of the variations need to be identified and researched to prevent future pyroshock problems.

Smith, J. L.↗

Hipot and continuity qualification est experience

High voltage potential (Hipot) and module frame continuity tests are important parts of determining the suitability of solar modules for deployment into large arrays for electrical power production. Since field arrays operate at hundreds of volts above (or below) ground potential at some point in the field, it is necessary to assure adequate voltage isolation of the solar cell circuits.

Griffith, J. S.↗

Separator Qualification for Aerospace Nickel-cadmium Cells

The development plans for a new separator for nickel cadmium (NiCd) cells is described. Research includes acceptance testing, operation in a charge/discharge characterization matrix, and life testing in low earth orbit (LEO) and geosynchronous (GEO) orbit under real time and accelerated conditions.

Milden, M. J.↗

Hubble space telescope component qualification utilizing a residual gas analyzer

An approach is described for integrating an automated residual gas analyzer (RGA) into the thermal vacuum outgas process. The RGA has the capability of detailed analysis over a 200 amu range with monitoring of each peak as the test progresses. The NASA criterion of either a 50% reduction of each peak over 44 amu or less than an 0.1% amplitude of the 28 amu base peak for all amu's above 44 amu is satisfied. A computer sorts, reports which peaks do not satisfy the criterion, and reports test completion. The computer plots amplitudes of all the peaks from 1 amu through 200 amu for each scan. This RGA real time approach is unique in that it provides sufficient detail to highlight a problem as it occurs. By comparison, a quartz crystal microbalance (QCM) or a thermoelectric quartz crystal microbalance (TQCM) indicates to the operator when changes occur, but not what has happened. Optical witness samples indicate whether a test was satisfactory within a few days after the test was completed.

Westfall, A. H.↗

Qualification of the T2 wind tunnel in cryogenic operation. A: Thermal field, preliminary study of a schematic model

The T2 wind tunnel is described. The process of generating a cyrogenic gust using the example of a test made at very low temperature is presented. Detailed results of tests on temperatures for flow in the settling chamber, the interior walls of the system, and the metal casing are given. The transverse temperature distribution in the settling chamber and working section, and of the thermal gradients in the walls, are given as a function of the temperature level of the test.

Dor, J. B.↗

Presentation of the acoustic and aerodynamic results of the Aladin 2 concept qualification testing

Wind tunnel tests were conducted of a scale model of the Aladin 2 aircraft. The propulsion system configuration is described and the air flow caused by jet ejection is analyzed. Three dimensional flow studies in the vicinity of the engine installation were made. Diagrams of the leading and trailing edge flaps are provided. Graphs are developed to show the aerodynamic performance under conditions of various airspeed and flap deflection.

Collard, M.↗

CID-720 aircraft Langley Research Center preflight hardware tests: Development, flight acceptance and qualification

The testing conducted on LaRC-developed hardware for the controlled impact demonstration transport aircraft is discussed. To properly develop flight qualified crash systems, two environments were considered: the aircraft flight environment with the focus on vibration and temperature effects, and the crash environment with the long pulse shock effects. Also with the large quantity of fuel in the wing tanks the possibility of fire was considered to be a threat to data retrieval and thus fire tests were included in the development test process. The aircraft test successfully demonstrated the performance of the LaRC developed heat shields. Good telemetered data (S-band) was received during the impact and slide-out phase, and even after the aircraft came to rest. The two onboard DAS tape recorders were protected from the intense fire and high quality tape data was recovered. The complete photographic system performed as planned throughout the 40.0 sec of film supply. The four photo power distribution pallets remained in good condition and all ten onboard 16 mm high speed (400 frames/sec) cameras produced good film data.

Pride, J. D.↗

Development of design criteria and qualification tests for bypass diodes in photovoltaic applications

Design criteria have been developed for bypass diodes in p-n and Schottky barrier in photovoltaic applications. A test method for assessing conformity to the design criteria is described. Junction temperatures are defined in terms of expected worst-case field conditions, including ambient temperature and solar irradiance on the photovoltaic module. The rating criteria address the maximum allowable current and heat-sink characteristics of diodes mounted inside or outside the photovoltaic module. The method establishes worst-case module-to-diode thermal interfaces and may be adapted for laboratory or field-site experiments. A list of the design criteria is given.

Otth, D. H.↗

Qualification Testing of General Electric 50 Ah Nickel-Cadmium Cells with New Separator and New Positive Plate Processing

Forty-two 50 Ah aerospace nickel-cadmium cells were delivered to Goddard Space Flight Center (GSFC) by General Electric (GE) in February, 1985, for the purpose of evaluating and qualifying a new nylon separator material Pellon 2536, and the new GE Positive Plate Nickel Attack Control Passivation process. Testing began in May, 1985, at the Naval Weapons Support Center (NWSC) in Crane, Indiana with standard initial evaluation tests. Life cycling in both Low Earth Orbit (LEO) and Geosynchronous Orbit (GEO) began in July, 1985, with approximately 1200 LEO cycles complete at this writting. Early test results show that cells with positive plate passivation exhibit higher than normal charge voltage characteristics. Other aspects of performance were nominal.

Morrow, G. W.↗

Aerospace nickel-cadmium cell separator qualifications program

The present space qualified nylon separator, Pellon 2505 ML, is no longer available for aerospace nickel-cadmium (NiCd) cells. As a result of this anticipated unavailability, a joint Government program between the Air Force Space Division and the Naval Research Laboratory was established. Four cell types were procured with both the old qualified and the new unqualified separators. Acceptance, characterization, and life cycling tests are to be performed at the Naval Weapons Support Center, Crane, Ind. (NWSC/Crane). The scheduling and current status of this program are discussed and the progress of testing and available results are projected.

Francis, R. W.↗

Qualification of S-glass/epoxy thermal isolator bands

Unidirectional fiberglass reinforced epoxy structures have been evaluated as thermal isolator tension straps for the charge-coupled devices on the Hubble Space Telescope's Wide Field/Planetary Camera. Mechanical and thermal properties are reported for filament-wound S-2 glass in a generic epoxy resin and compared to S-901 glass bands used on a previous camera. Measurements were performed on very small paper clip-shaped bands. Probably the smallest in length and have a load carrying mean cross sectional area of only 0.00024 square inches.

Bauer, Jerry↗

Qualification testing of General Electric 50 Ah nickel-cadmium cells with Pellon 2536 separator and passivated positive plates

Forty-two 50 Ah nickel-cadmium cells were delivered to the Goddard Space Flight Center (GSFC) by General Electric (GE) in February, 1985 for the purpose of evaluating and qualifying a nonwoven nylon separator material, Pellon 2536, and the GE positive plate nickel attack control gas passivation process. Testing began May, 1985 at the Naval Weapons Support Center (NWSC) in Crane, Indiana with GSFC standard initial evaluation tests. Life cycling in both Low Earth Orbit (LEO) and Geosynchronous Orbit (GEO) began in July, 1985 with approximately 6500 LEO cycles and three GEO eclipse seasons completed. After early problems in maintaining test pack temperature control, all packs are performing well but are exhibiting higher than normal charge voltage characteristics.

Morrow, George W.↗

Qualification of room-temperature-curing epoxy adhesives for spacecraft structural applications

An adhesive-bonding test program is being conducted in order to develop structural adhesives applicable to JPL spacecraft. A noteworthy application for such an adhesive will be JPL's Galileo mission, whose trajectory will involve the circumnavigation of the planet Venus prior to Jupiter rendezvous, and will accordingly require stringent temperature and radiation environment requirements. The baseline adhesive for the test program is the EA 934 room temperature-cure epoxy, which has been widely used as a 'space-qualified' material.

Carpenter, Alain↗