Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Preliminary design approach for large high precision segmented reflectors

A simplified preliminary design capability for erectable precision segmented reflectors is presented. This design capability permits a rapid assessment of a wide range of reflector parameters as well as new structural concepts and materials. The preliminary design approach was applied to a range of precision reflectors from 10 meters to 100 meters in diameter while considering standard design drivers. The design drivers considered were: weight, fundamental frequency, launch packaging volume, part count, and on-orbit assembly time. For the range of parameters considered, on-orbit assembly time was identified as the major design driver. A family of modular panels is introduced which can significantly reduce the number of reflector parts and the on-orbit assembly time.

Mikulas, Martin M., Jr.↗

Precision measurements of photoabsorption cross sections of Ar, Kr, Xe, and selected molecules at 58.4, 73.6, and 74.4 nm

Absolute absorption cross sections have been measured for the rare gases at 58.43, 73.59, and 74.37 nm with an accuracy of + or - 0.8 percent. For the molecules H2, N2, O2, CO, N2O, CO2, and CH4, precision measurements were made at 58.43 nm with an accuracy of + or - 0.8 percent. Molecular absorption cross sections are also reported at 73.59 and 74.37 nm. However, in the vicinity of these wavelengths most molecules exhibit considerable structure, and cross sections measured at these wavelengths may depend on the widths and the amounts of self-reversal of these resonance lines. A detailed discussion is given of the systematic errors encountered with the double-ion chamber used in the cross-sectional measurements. Details are also given of precision pressure measurements.

Samson, James A. R.↗

Preliminary design considerations for 10 to 40 meter-diameter precision truss reflectors

A simplified preliminary design capability for erectable precision segmented reflectors is presented. This design capability permits a rapid assessment of a wide range of reflector parameters as well as new structural concepts and materials. The preliminary design approach was applied to a range of precision reflectors from 10 meters to 100 meters in diameter while considering standard design drivers. The design drivers considered were: weight, fundamental frequency, launch packaging volume, part count, and on-orbit assembly time. For the range of parameters considered, on-orbit assembly time was identified as the major design driver. A family of modular panels is introduced which can significantly reduce the number of reflector parts and the on-orbit assembly time.

Mikulas, Martin M., Jr.↗

Precise monitoring of global temperature trends from satellites

Passive microwave radiometry from satellites provides more precise atmospheric temperature information than that obtained from the relatively sparse distribution of thermometers over the earth's surface. Accurate global atmospheric temperature estimates are needed for detection of possible greenhouse warming, evaluation of computer models of climate change, and for understanding important factors in the climate system. Analysis of the first 10 years (1979 to 1988) of satellite measurements of lower atmospheric temperature changes reveals a monthly precision of 0.01 C, large temperature variability on time scales from weeks to several years, but no obvious trend for the 10-year period. The warmest years, in descending order, were 1987, 1988, 1983, and 1980. The years 1984, 1985, and 1986 were the coolest.

Spencer, Roy W.↗

Structures technologies for the Precision Segmented Reflector (PSR)

The PSR program is a first step in the development and validation of increasingly more precise and larger size lightweight segmented reflector technology that might ultimately be used in space on projects such as the Large Deployable Reflector (LDR). The LDR is described, and objectives of the PSR are discussed. Requirements for the PSR, including structure dimensions and geometric constraints, mass characteristics, erectable and deployable concepts, truss surface precision, and thermal and dynamic characteristics are discussed along with gravity deflections, secondary support characteristics, and removable members. Analytical development and system- and component-level tests are outlined.

Satter, C. M.↗

Flight evaluations of several hover control and display combinations for precise blind vertical landings

Several control and display concepts were evaluated on a variable-stability helicopter prior to future evaluations on a modified Harrier. The control and display concepts had been developed to enable precise hover maneuvers, station keeping, and vertical landings in simulated zero-visibility conditions and had been evaluated extensively in previous piloted simulations. Flight evaluations early in the program revealed several inadequacies in the display drive laws that were later corrected using an alternative design approach that integrated the control and display characteristics with the desired guidance law. While hooded, three pilots performed landing-pad captures followed by vertical landings with attitude-rate, attitude, and translation-velocity-command control systems. The latter control system incorporated a modified version of state-rate-feedback implicit-model following. Precise landing within 2 ft of the desired touchdown point were achieved.

Schroeder, J. A.↗

Demonstration of precise estimation of polar motion parameters with the global positioning system: Initial results

Data from the Global Positioning System (GPS) were used to determine precise polar motion estimates. Conservatively calculated formal errors of the GPS least squares solution are approx. 10 cm. The GPS estimates agree with independently determined polar motion values from very long baseline interferometry (VLBI) at the 5 cm level. The data were obtained from a partial constellation of GPS satellites and from a sparse worldwide distribution of ground stations. The accuracy of the GPS estimates should continue to improve as more satellites and ground receivers become operational, and eventually a near real time GPS capability should be available. Because the GPS data are obtained and processed independently from the large radio antennas at the Deep Space Network (DSN), GPS estimation could provide very precise measurements of Earth orientation for calibration of deep space tracking data and could significantly relieve the ever growing burden on the DSN radio telescopes to provide Earth platform calibrations.

Lichten, S. M.↗

Sliding mode control of magnetic suspensions for precision pointing and tracking applications

A recently developed nonlinear control method, sliding mode control, is examined as a means of advancing the achievable performance of space-based precision pointing and tracking systems that use nonlinear magnetic actuators. Analytic results indicate that sliding mode control improves performance compared to linear control approaches. In order to realize these performance improvements, precise knowledge of the plant is required. Additionally, the interaction of an estimating scheme and the sliding mode controller has not been fully examined in the literature. Estimation schemes were designed for use with this sliding mode controller that do not seriously degrade system performance. The authors designed and built a laboratory testbed to determine the feasibility of utilizing sliding mode control in these types of applications. Using this testbed, experimental verification of the authors' analyses is ongoing.

Misovec, Kathleen M.↗

Precise frequency calibration using television video carriers

The availability of inexpensive and quick precise frequency calibration methods is limited. VLF and GPS do offer precise calibration. However, antenna placement, cost of equipment, and calibration time place many restrictions on the user. The USNO maintained line-10 television Time of Coincidence (TOC) of station WTTG, channel 5, Washington, DC requires a frequency stable video carrier. This video carrier, 77.24 MHz is controlled by the same cesium beam standard controlling the TOC of line-10. Excellent frequency comparisons against this video carrier have been accomplished at 95 miles (153 km). With stable propagation and a three foot wire antenna, a part in 10(exp 9) can be determined in a few minutes. Inexpensive field equipment with a synthesized 1 kHz offset from the video carrier offers parts in 10(exp 11) calibrations in a few minutes using an oscilloscope as a phase comparator.

Burkhardt, Edward E.↗

The use of precise ephemerides, ionospheric data, and corrected antenna coordinates in a long-distance GPS time transfer

Over intercontinental distances, the accuracy of The Global Positioning System (GPS) time transfers ranges from 10 to 20 ns. The principal error sources are the broadcast ionospheric model, the broadcast ephemerides and the local antenna coordinates. For the first time, the three major error sources for GPS time transfer can be reduced simultaneously for a particular time link. Ionospheric measurement systems of the National Institute of Standards and Technology (NIST) type are now operating on a regular basis at the National Institute of Standards and Technology in Boulder and at the Paris Observatory in Paris. Broadcast ephemerides are currently recorded for time-transfer tracks between these sites, this being necessary for using precise ephemerides. At last, corrected local GPS antenna coordinates are now introduced in GPS receivers at both sites. Shown here is the improvement in precision for this long-distance time comparison resulting from the reduction of these three error sources.

Lewandowski, Wlodzimierz W.↗

Development of an active truss element for control of precision structures

An active structural element for use in precision control of large space structures is described. The active member is intended to replace a passive strut in a truss-like structure. It incorporates an eddy current displacement sensor and an actuator that is either piezoelectric (PZT) or electrostrictive (PMN). The design of the device is summarized. Performance of separate PZT and PMN actuators is compared for several properties relevant to submicrometer control of precision structures.

Anderson, Eric H.↗

Precision engineering and optomechanics; Proceedings of the Meeting, San Diego, CA, Aug. 10, 11, 1989

Various papers on precision engineering and optomechanics are presented. Individual topics addressed include: performance optimization of an IR sensor optical system, design and development of a rugged airborne scanning optical assembly for a calibrated IR imaging radiometer, numerical method for Cassegrain telescope baffle design, precision alignment of an IR imaging system, optical alignment of a pupil imaging spectrometer, optical alignment equipment and methods for visible and IR imaging meteorological radiometer. Also addressed are: vibration-design aspects of an IR-scanning earth sensor, chopping secondary mirror for the Kuiper Airborne Observatory, advanced flexure suspension systems, subminiature IR detector translation stage, thermal/optical test setup for the Geostationary Operational Environmental Satellite Telescope, design of the GOES telescope secondary mirror mounting.

Vukobratovich, Daniel↗

Precise automatic differential stellar photometry

The factors limiting the precision of differential stellar photometry are reviewed. Errors due to variable atmospheric extinction can be reduced to below 0.001 mag at good sites by utilizing the speed of robotic telescopes. Existing photometric systems produce aliasing errors, which are several millimagnitudes in general but may be reduced to about a millimagnitude in special circumstances. Conventional differential photometry neglects several other important effects, which are discussed in detail. If all of these are properly handled, it appears possible to do differential photometry of variable stars with an overall precision of 0.001 mag with ground based robotic telescopes.

Young, Andrew T.↗

A mathematical basis for the design optimization of adaptive trusses in precision control

Optimal actuator placement schemes are presently studied for cases of adaptive truss precision control and prestressing control, with a view to the maximization of actuator efficiencies. In statically indeterminate truss structures, the optimal placement criteria and techniques differ, depending on whether the primary determinate structure is known. A suboptimal actuator-placement solution to the global optimization problem which combines displacement control and prestressing control is suggested, by combining the separate displacement control and prestressing control optimization results. Attention is given to the results obtained for the illustrative case of a two-bay, three-dimensional precision truss structure.

Das, S. K.↗

Testing and application of a viscous passive damper for use in precision truss structures

A passive damping device intended to replace individual struts in precision truss structures for space applications is described. The theory of operation of the D-Strut device is detailed, and simple five- and three-parameter models are derived. Results from tests conducted to characterize the D-Strut at submicron displacement levels are reporeted. The incorporation of a strut in a precision truss testbed is described. Parameters determined from the component-level tests are used in a finite element model of the truss, and damping augmentation is predicted. Using the simple three-parameter model, a damper is selected for multiple placement in a separate optical interferometer truss testbed. The effect of the addition of the damper struts is illustrated analytically in a model of the structure. Finally, an improved Arched Flexure D-Strut that is expected to provide higher loss factors, and is currently under development, is described.

Trubert, M.↗

The development of composite materials for spacecraft precision reflector panels

One of the critical technology needs for large precision reflectors required for future astrophysics and optical communications is in the area of structural materials. Therefore, a major area of the Precision Segmented Reflector Program at NASA is to develop lightweight composite reflector panels with durable, space environmentally stable materials which maintain both surface figure and required surface accuracy necessary for space telescope applications. Results from the materials research and development program at NASA Langley Research Center are discussed. Advanced materials that meet the reflector panel requirements are identified. Thermal, mechanical and durability properties of candidate materials after exposure to simulated space environments are compared to the baseline material.

Tompkins, Stephen S.↗

Recent results on structural control of an active precision structure

This paper describes recent results in structural control of an active precision truss structure at JPL. The goal is to develop practical control methodology and to apply to active truss structures intended for high precision space-based optics applications. The active structure considered incorporates piezoelectric active members which apply control forces internal to the structure and thereby improve the structure's dimensional stability. Two approaches to structural control system design were investigated. The first approach uses only noncollocated measurements of acceleration at the location of a simulated optical component to achieve structural stabilization. The second approach is essentially the same as the first one except that a viscous damper was used in place of a truss member on the structure to improve the dampings of selected flexible modes. The corresponding experimental closed-loop results are presented in this paper.

Chu, C. C.↗

Precise Countersinking Tool

Tool countersinks holes precisely with only portable drill; does not require costly machine tool. Replaceable pilot stub aligns axis of tool with centerline of hole. Ensures precise cut even with imprecise drill. Designed for relatively low cutting speeds.

Jenkins, Eric S.↗