Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power system operational models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Impact of Storage Dispatch Assumptions on Resource Adequacy and Capacity Credit

Representing energy-limited resources in power system probabilistic resource adequacy assessment introduces new considerations that invalidate classical modeling assumptions. In particular, such resources have multi-period operating objectives and constraints that in real systems are addressed via a sequence of rolling intertemporal optimizations. Ideally, adequacy models would develop dispatch decisions by solving a similar sequence of problems, but this approach has historically been too computationally intensive for practical use in Monte Carlo simulations, with studies making use of simplifying approximations instead. These simplifications have the potential to distort the assessed value of energy-limited resources on the system.This work describes three classes of storage dispatch assumptions in current use and discusses their theoretical differences. It then provides an empirical analysis of their differences on test systems with different levels of storage, assessing the potential for a study's modeling assumptions to influence the perceived contribution of energy-limited resources.

capacity credit↗

Impedance Matching a Quarter Wave Resonant Receiver to Improve Efficiency in Unipolar Capacitive Wireless Power Transfer

Impedance matching techniques to achieve high performance in conventional wireless power transfer (WPT) systems are well established. These WPT systems are modelled as a lumped circuit, where the voltages/currents are approximately uniform and mostly unaffected by parasitic elements. However, a group of WPT techniques exist that utilize parasitic elements to form a highly resonant power transfer condition at high quality factors, exploiting a distributed circuit operation that can be modeled as a mutually coupled transmission line. A calculated matching network typically becomes unmatched when connected to the transmission line, as it changes the electrical structure of the coupled transmission line. This is particularly true for WPT systems that use quarter wave (QWR) or half wave resonators (HWR) for the receiver. Here we present one technique of matching to a mutually coupled transmission line where a parallel path is formed that improves the power transfer efficiency without severely altering the transmission line characteristics.

Wireless↗

Reactor Power Level Estimation by Fusing Multi-Modal Sensor Measurements

Estimates of the power level of a nuclear reactor based on measurements from an independent monitoring sensor system can help in the compliance verification of its declared operations. We present a three-level fusion method to estimate the power level of a nuclear reactor using features derived from infrared, electromagnetic, and acoustic sensor measurements collected in proximity to the reactor. Based on a simplified analytical model of the secondary coolant system of the reactor, we identify partial regression functions of the power level in terms of the temperature difference between inlet and outlet of coolant pipes, and the activity levels of four fans and four pumps, which are estimated as features from the sensor measurements. The power level estimator employs a combination of aggregate and complementary fusion steps at three levels to incorporate the multi-modal features in a structure that reflects the secondary cooling system and its partial regression functions. Using the measurements from a test campaign at an operational reactor, we show that this estimator achieves 3.47% or lower root mean square error under 5-fold cross validation. More generally, these results illustrate a progressive reduction in estimation error as additional modalities are appropriately incorporated, and that the fuser outperforms single modality features and their sub-combinations.

Rao, Nageswara↗

Coordinated distribution network control of tap changer transformers, capacitors and PV inverters

A power distribution system operates most efficiently with voltage deviations along a feeder kept to a minimum and must ensure all voltages remain within specified limits. Recently with the increased integration of photovoltaics, the variable power output has led to increased voltage fluctuations and violation of operating limits. This study proposes an optimization model based on a recently developed heuristic search method, grey wolf optimization, to coordinate the various distribution controllers. Several different case studies on IEEE 33 and 69 bus test systems modified by including tap changing transformers, capacitors and photovoltaic solar panels are performed. Simulation results are compared to two other heuristic-based optimization methods: harmony search and differential evolution. Finally, the simulation results show the effectiveness of the method and indicate the usage of reactive power outputs of PVs facilitates better voltage magnitude profile.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PHARAO laser source flight model: Design and performances

In this paper, we describe the design and the main performances of the PHARAO laser source flight model. PHARAO is a laser cooled cesium clock specially designed for operation in space and the laser source is one of the main sub-systems. The flight model presented in this work is the first remote-controlled laser system designed for spaceborne cold atom manipulation. The main challenges arise from mechanical compatibility with space constraints, which impose a high level of compactness, a low electric power consumption, a wide range of operating temperature, and a vacuum environment. We describe the main functions of the laser source and give an overview of the main technologies developed for this instrument. We present some results of the qualification process. The characteristics of the laser source flight model, and their impact on the clock performances, have been verified in operational conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AATTENUATION—The Atmospheric Attenuation Model for CSP Tower Plants: A Look-Up Table for Operational Implementation

Attenuation of solar radiation between the receiver and the heliostat field in concentrated solar power (CSP) tower plants can reduce the overall system performance significantly. The attenuation varies strongly with time and the average attenuation at different sites might also vary strongly from each other. If no site specific attenuation data is available, the optimal plant design cannot be determined and rough estimations of the attenuation effect are required leading to high uncertainties of yield analysis calculations. The attenuation is caused mainly by water vapor content and aerosol particles in the lower atmospheric layer above ground. Although several on-site measurement systems have been developed during recent years, attenuation data sets are usually not available to be included during the plant project development. An Atmospheric Attenuation (AATTENUATION) model to derive the atmospheric transmittance between a heliostat and receiver on the basis of common direct normal irradiance (DNI), temperature, relative humidity, and barometric pressure measurements was developed and validated by the authors earlier. The model allows the accurate estimation of attenuation for sites with low attenuation and gives an estimation of the attenuation for less clear sites. However, the site-dependent coefficients of the AATTENUATION model had to be developed individually for each site of interest, which required time-consuming radiative transfer simulations, considering the exact location and altitude, as well as the pre-dominant aerosol type at the location. This strongly limited the application of the model despite its typically available input data. In this manuscript, a look-up table (LUT) is presented which enables the application of the AATTENUATION model at the site of interest without the necessity to perform the according complex radiative transfer calculations for each site individually. This enables the application of the AATTENUATION model for virtually all resource assessments for tower plants and in an operational mode in real time within plant monitoring systems around the world. The LUT also facilitates the generation of solar attenuation maps on the basis of long-term meteorological data sets which can be considered during resource assessment for CSP tower plant projects. The LUTs are provided together with this manuscript as supplementary files. The LUT for the AATTENUATION model was developed for a solar zenith angle (SZA) grid of 1°, an altitude grid of 100 m, 7 different standard aerosol types and the standard AFGL atmospheres for mid-latitudes and the tropics. The LUT was tested against the original version of the AATTENUATION model at 4 sites in Morocco and Spain, and it was found that the additional uncertainty introduced by the application of the LUT is negligible. With the information of latitude, longitude, altitude above mean sea level, DNI, relative humidity (RH), ambient temperature (Tair), and barometric pressure (bp), the attenuation can be now derived easily for each site of interest.

14 SOLAR ENERGY↗

Use Cases and Model Development of Thermal Storage Coupling for Advanced Nuclear Reactors

This report discusses the different options for coupling thermal energy storage (TES) systems to advanced nuclear power plants (A-NPPs) in order to enable flexible and hybrid plant operation. An advanced light-water reactor (ALWR) and a high-temperature gas-cooled reactor (HTGR) were selected as the initial use cases for demonstrating a thermally balanced energy storage coupling design for thermal power extraction. Cost functions for the A-LWR were derived from the fully balanced models that were developed based on three different coupling options with three different thermal energy bypass ratios. For the next steps, cost functions for the HTGR will also be derived, and additional nuclear reactors (e.g., a liquid-cooled fast reactor [LFR] or molten-salt reactor [MSR]) will be evaluated for coupling with TES in similar fashion, including the evaluation of their steady-state condition models and cost functions. The models presented herein showcase several design considerations, focusing on optimal deployment methodologies for achieving steady-state operation with minimum disruption to the nuclear power generation cycle. This report presents the results of steady state models developed using Aspen HYSYS®, wherein the thermal energy bypass for an NPP-TES coupling was varied up to 50%. The various components were sized using Aspen Process Economic Analyzer (APEA) and Aspen Exchanger Design and Rating (EDR), when applicable. Cost functions from these models were developed using the latest publicly available data obtained from APEA V11. The current steady-state models and cost functions provide a baseline for additional work focusing on dynamic operation and process optimization by using Idaho National Laboratory (INL)’s Framework for Optimization of Resources and Economics (FORCE) tools to evaluate the technoeconomic viability and transient operations of TES-coupled A-NPPs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Utilizing the SACADA system to collect simulator training data to inform human reliability analyses - 169

Lack of appropriate human performance data for the development of human reliability analysis (HRA) methods has been identified as a key issue contributing to the method-to-method variability among the HRA methods. The United States Nuclear Regulatory Commission (NRC) worked with domain experts to develop the Scenario Authoring, Characterization, and Debriefing Application (SACADA) system to collect nuclear power plants' licensed operator simulator training and examination data to inform HRA. In the past two decades, significant improvements in understanding and modelling human performance in HRA have affected the perspectives of the types of data to be collected for HRA. A significant change is that human performance is strongly dependent on the context of the tasks to be performed. To incorporate this understanding, the SACADA data taxonomy collects the context and actual performance information of the training objective elements (TOEs) in nuclear plant operator simulator training. This provides a framework consistent with HRA to use context to estimate human error probabilities. It is recognized that measuring crew performance is equally important as improving operator training. SACADA is designed to support the nuclear trainers in capturing this important information that is used to identify training weaknesses and drive continuous improvement. This paper discusses the SACADA taxonomy, the SACADA system's functions, and the supporting software design to enable the SACADA system to be practically implemented in the nuclear power plants' operator simulator training program to collect data for tracking operator performance and HRA analysis. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Role of Operating Flexibility in Planning Studies

This project was conceived to examine the flexibility needs of the future California power grid. The analysis explores the need to establish generation planning metrics and standards that explicitly consider the operating flexibility needs of the system as the State pursues its aggressive renewable power generation goals. New methods and tools have been developed to use high resolution models of the grid that take into account uncertainties regarding renewable generation, load, equipment reliability, and economic growth. These models leverage high performance computational resources to fully explore the range of possible grid conditions that may lead to loss of load. The cost effectiveness of operating policies and hardware configurations that increase grid flexibility are examined with the tools to provide actionable information to grid planners and stakeholders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Distribution System Adaptive Restoration with Diverse Distributed Energy Resources

Distributed energy resources (DERs) can be utilized as alternative power sources for fast service recovery in cases of distribution system outages. However, the diverse characteristics and stochastic nature of DERs impose challenges on the optimal operation of di-verse resources during the restoration phase. Here, we introduce a hierarchical structure to coordinate distribution system entities and propose an adaptive restoration strategy to sustain a reliable power supply to outage loads in an unbalanced distribution system utilizing DERs. An efficient system reconfiguration model is developed to guarantee the radiality of restoration islands. The flexibility of DERs is evaluated by a novel method that focuses on the cumulative energy consumption, the superiority of which is also proven. Model predictive control (MPC) is adopted to enable the adjustment of system topology and DER operation strategies based on up-to-date data. The performance of the proposed restoration model is validated on a modified IEEE 123-bus test system. Moreover, the effectiveness of the proposed novel flexibility assessment and the MPC-based adaptive restoration strategy are verified through comparative studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Operational Simulation of Multi-Functional Charging Station for Sustainable Transportation

As transportation systems move toward electrification and decarbonization, multifunctional charging stations (MFCS) are emerging as key infrastructure for electric vehicles (EVs) and hydrogen fuel cell vehicles (HFCVs). This paper presents a simulation model of an MFCS that integrates solar photovoltaic (PV), wind power, battery storage, hydrogen (\mathrm{H}_{2}) production, dual-pressure \mathrm{H}_{2} storage, fuel cells, and dynamic grid interactions. The model simulates daily operations using 5 -minute resolution data to capture realtime variability in renewable energy (RE), demand, and electricity prices. A flexible dispatch algorithm dynamically allocates energy for EV charging, \mathrm{H}_{2} production, storage, and grid transactions while respecting system constraints. Results show that the MFCS effectively prioritizes RE usage, minimizes waste, meets diverse energy demands, and achieves net operational profit. The model serves as a valuable decision-support tool for designing and optimizing integrated clean energy hubs for zero-emission transportation.

Gbadegoye, Jeremiah [University of Tennessee, Knox↗

Thermal Design for Extra-Terrestrial Regenerative Fuel Cell System

The Advanced Exploration Systems (AES) Advanced Modular Power Systems (AMPS) Project is investigating different power systems for various lunar and Martian mission concepts. The AMPS Fuel Cell (FC) team has created two system-level models to evaluate the performance of regenerative fuel cell (RFC) systems employing different fuel cell chemistries. Proton Exchange Membrane fuel cells PEMFCs contain a polymer electrolyte membrane that separates the hydrogen and oxygen cavities and conducts hydrogen cations (protons) across the cell. Solid Oxide fuel cells (SOFCs) operate at high temperatures, using a zirconia-based solid ceramic electrolyte to conduct oxygen anions across the cell. The purpose of the modeling effort is to down select one fuel cell chemistry for a more detailed design effort. Figures of merit include the system mass, volume, round trip efficiency, and electrolyzer charge power required. PEMFCs operate at around 60 C versus SOFCs which operate at temperatures greater than 700 C. Due to the drastically different operating temperatures of the two chemistries the thermal control systems (TCS) differ. The PEM TCS is less complex and is characterized by a single pump cooling loop that uses deionized water coolant and rejects heat generated by the system to the environment via a radiator. The solid oxide TCS has its own unique challenges including the requirement to reject high quality heat and to condense the steam produced in the reaction. This paper discusses the modeling of thermal control systems for an extraterrestrial RFC that utilizes either a PEM or solid oxide fuel cell.

thermal modeling↗

Thermal System Modeling for Lunar and Martian Surface Regenerative Fuel Cell Systems

The Advanced Exploration Systems (AES) Advanced Modular Power Systems (AMPS) Project is investigating different power systems for various lunar and Martian mission concepts. The AMPS Fuel Cell (FC) team has created two system-level models to evaluate the performance of regenerative fuel cell (RFC) systems employing different fuel cell chemistries. Proton Exchange Membrane fuel cells PEMFCs contain a polymer electrolyte membrane that separates the hydrogen and oxygen cavities and conducts hydrogen cations (protons) across the cell. Solid Oxide fuel cells (SOFCs) operate at high temperatures, using a zirconia-based solid ceramic electrolyte to conduct oxygen anions across the cell. The purpose of the modeling effort is to down select one fuel cell chemistry for a more detailed design effort. Figures of merit include the system mass, volume, round trip efficiency, and electrolyzer charge power required. PEMFCs operate at around 60 degrees Celsius versus SOFCs which operate at temperatures greater than 700 degrees Celsius. Due to the drastically different operating temperatures of the two chemistries the thermal control systems (TCS) differ. The PEM TCS is less complex and is characterized by a single pump cooling loop that uses deionized water coolant and rejects heat generated by the system to the environment via a radiator. The solid oxide TCS has its own unique challenges including the requirement to reject high quality heat and to condense the steam produced in the reaction. This paper discusses the modeling of thermal control systems for an extraterrestrial RFC that utilizes either a PEM or solid oxide fuel cell.

thermal modeling↗

Sampling Technique for Robust Odorant Detection Based on MIT RealNose Data

This technique enhances the detection capability of the autonomous Real-Nose system from MIT to detect odorants and their concentrations in noisy and transient environments. The lowcost, portable system with low power consumption will operate at high speed and is suited for unmanned and remotely operated long-life applications. A deterministic mathematical model was developed to detect odorants and calculate their concentration in noisy environments. Real data from MIT's NanoNose was examined, from which a signal conditioning technique was proposed to enable robust odorant detection for the RealNose system. Its sensitivity can reach to sub-part-per-billion (sub-ppb). A Space Invariant Independent Component Analysis (SPICA) algorithm was developed to deal with non-linear mixing that is an over-complete case, and it is used as a preprocessing step to recover the original odorant sources for detection. This approach, combined with the Cascade Error Projection (CEP) Neural Network algorithm, was used to perform odorant identification. Signal conditioning is used to identify potential processing windows to enable robust detection for autonomous systems. So far, the software has been developed and evaluated with current data sets provided by the MIT team. However, continuous data streams are made available where even the occurrence of a new odorant is unannounced and needs to be noticed by the system autonomously before its unambiguous detection. The challenge for the software is to be able to separate the potential valid signal from the odorant and from the noisy transition region when the odorant is just introduced.

Duong, Tuan A.↗

Small-Signal Stability Analysis of Large-Scale Power Systems in Response to Variability of Offshore Wind Power Plants

This paper presents a methodology for a small-signal stability analysis of large-scale power systems in response to variability of offshore wind power plants. This study considers the variability of wind power as the source of disturbance introduced to the system. To accomplish this goal, a singular value decomposition-total least squares extended Prony analysis is used to assess the small-signal voltage stability. In addition, a swing-based frequency response metric is used to assess the small-signal frequency stability. The case study here considers the integration of a 1000-MW offshore wind power plant, operating in Lake Erie, into the FirstEnergy/PJM service territory. This study uses a realistic model of the 63 000-bus test system that represents the U.S. Eastern Interconnection. The results verify the utility and practicality of this methodology for the integration studies of offshore wind power plants.

17 WIND ENERGY↗

Diii-D Research Advancing The Physics Basis For Optimizing The Tokamak Approach To Fusion Energy

DIII-D physics research addresses critical challenges for operation of ITER and the next generation of fusion energy devices. This is done through a focus on innovations to provide solutions for high performance long pulse operation, coupled with fundamental plasma physics understanding and model validation, to drive scenario development by integrating high performance core and boundary plasmas. Substantial increases in off-axis current drive efficiency from an innovative top launch system for EC power, and in pressure broadening for Alfven eigenmode control from a co-/counter-Ip steerable off-axis neutral beam, all improve the prospects for optimization of future long pulse/steady state high performance tokamak operation. Fundamental studies into the modes that drive the evolution of the pedestal pressure profile and electron vs. ion heat flux validate predictive models of pedestal recovery after ELMs. Understanding the physics mechanisms of ELM control and density pumpout by 3D magnetic perturbation fields leads to confident predictions for ITER and future devices. Validated modeling of high-Z shattered pellet injection for disruption mitigation, runaway electron dissipation, and techniques for disruption prediction and avoidance including machine learning, give confidence in handling disruptivity for future devices. With this physics understanding and suite of actuators, a high poloidal beta optimized-core scenario with an internal transport barrier that projects nearly to Q=10 in ITER at 9 MA was coupled to a detached divertor, and a near Super H-mode optimized-pedestal scenario with co-Ip beam injection, was coupled to a radiative divertor. The Hybrid core scenario was achieved directly, without the need for internal flux pumping, using off-axis current drive actuators, and a controller to avoid mode locking and disruptions in the ITER baseline scenario, based on plasma response to probing 3D fields, was demonstrated. Finally innovative tokamak operation using a negative triangularity shape showed many attractive features for future pilot plant operation.

Fenstermacher, M.↗

Electrification Futures Study: Scenarios of Power System Evolution

Electrification of end-use technologies could have important implications for bulk power sector planning, operations, and impacts. By combining previously-defined electrification scenarios with capacity expansion modeling, we evaluate the potential challenges and opportunities associated with electrification. Our scenario analysis reveals that electrification reduces energy consumption and air emissions from across the energy sector, and its impacts on energy system costs are modest due, in part, to the abundance of low-cost resources in the United States.

43 PARTICLE ACCELERATORS↗