Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle accelerator sciences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

New ambient pressure photoemission endstation at Advanced Light Source beamline 9.3.2

During the past decade, the application of ambient pressure photoemission spectroscopy (APPES) has been recognized as an important in situ tool to study environmental and materials science, energy related science, and many other fields. Several APPES endstations are currently under planning or development at the USA and international light sources, which will lead to a rapid expansion of this technique. The present work describes the design and performance of a new APPES instrument at the Advanced Light Source beamline 9.3.2 at Lawrence Berkeley National Laboratory. This new instrument, Scienta R4000 HiPP, is a result of collaboration between Advanced Light Source and its industrial partner VG-Scienta. The R4000 HiPP provides superior electron transmission as well as spectromicroscopy modes with 16 {mu}m spatial resolution in one dimension and angle-resolved modes with simulated 0.5 deg. angular resolution at 24 deg. acceptance. Under maximum transmission mode, the electron detection efficiency is more than an order of magnitude better than the previous endstation at beamline 9.3.2. Herein we describe the design and performance of the system, which has been utilized to record spectra above 2 mbar.

43 PARTICLE ACCELERATORS↗

DCS - A high flux beamline for time resolved dynamic compression science – Design highlights

The Dynamic Compression Sector (DCS) beamline, a national user facility for time resolved dynamic compression science supported by the National Nuclear Security Administration (NNSA) of the Department of Energy (DOE), has recently completed construction and is being commissioned at Sector 35 of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The beamline consists of a First Optics Enclosure (FOE) and four experimental enclosures. A Kirkpatrick–Baez focusing mirror system with 2.2 mrad incident angles in the FOE delivers pink beam to the experimental stations. A refocusing Kirkpatrick–Baez mirror system is situated in each of the two most downstream enclosures. Experiments can be conducted in either white, monochromatic, pink or monochromatic-reflected beam mode in any of the experimental stations by changing the position of two interlocked components in the FOE. The beamline Radiation Safety System (RSS) components have been designed to handle the continuous beam provided by two in-line revolver undulators with periods of 27 and 30 mm, at closed gap, 150 mA beam current, and passing through a power limiting aperture of 1.5 x 1.0 mm{sup 2}. A novel pink beam end station stop [1] is used to stop the continuous and focused pink beam which can achieve a peak heat flux of 105 kW/mm{sup 2}. A new millisecond shutter design [2] is used to deliver a quick pulse of beam to the sample, synchronized with the dynamic event, the microsecond shutter, and the storage ring clock.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3 GeV Booster Synchrotron Conceptual Design Report

Synchrotron light cna be produced from a relativistic particle beam circulating in a storage ring at extremely high intensity and brilliance over a large spectral region reaching from the far infrared regime to hard x-rays. The particles, either electrons or positrons, radiate as they are deflected in the fields of the storage ring bending magnets or of magnets specially optimized for the production of synchrotron light. The synchrotron light being very intense and well collimated in the forward direction has become a major tool in a large variety of research fields in physics, chemistry, material science, biology, and medicine.

43 PARTICLE ACCELERATORS↗

Tunable Laser-Plasma Amplifier (Final Report)

Exploration at the laser intensity frontier has always offered new avenues for physics and reaching beyond this frontier is a grand challenge. Present-day petawatt-class lasers provide focused intensities on target of 10 22 W/cm 2 , corresponding to electric fields of 200 TV/m, while laser-plasma amplification opens a route for focused intensities well above 10 23 W/cm 2 . Intensities in this range provide the ability to test quantum electrodynamics in the unexplored low-energy, strong-field regime where signatures for new physics may arise. The behavior of matter under such extraordinary conditions is a rich and fascinating subject, not only in its own right in fundamental plasma physics, but for the many potential applications that promise to enrich the natural sciences in the future, including compact electron-beam, ion-beam particle accelerators, and ultra-bright X-ray sources. Although laser systems are now under construction internationally to access intensities of 10 23 W/cm 2 , the current technologies used appear to be fundamentally limited to these intensities. The realization of intensities beyond 10 23 W/cm 2 using parametric amplification in plasmas promises a breakthrough in high-energy density physics. Parametric amplification using Raman scattering in a plasma could provide the enabling technology for the generation of ultra-high-power laser pulses, but a more complete understanding of the nonlinear optics of plasmas is required. There is a significant gap in well-diagnosed laser-plasma instability studies of nonlinear plasma-wave phenomena, which are critical to understand for future laser-plasma devices. To achieve an efficient laser-plasma amplifier, plasma waves must be driven to large amplitude where significant energy can be rapidly transferred from the pump to the seed over the pulse duration of the seed. Simulations suggest that this nonlinear pump depletion regime can be achieved in the “pi-pulse” amplification regime. While simulations show this optimal regime with efficient amplification, it has remained elusive in experiments and there is a growing consensus within the community that thermal effects and pump beam limitations prevent laser-plasma amplifiers from progressing through the linear regime into the nonlinear pump depletion regime. Previous experiments have been significantly limited by the laser power available at the necessary wavelengths for the seed laser; therefore, the amplification is required to start in the linear regime where it is sensitive to many deleterious effects. The enabling technology (currently unique to plasma-wave amplification in the world) at the University of Rochester is the ability to provide a seed pulse with sufficient power (4 mJ/100 fs seed) to immediately drive nonlinear plasma waves into the pi-pulse regime and to tune its wavelength to optimize the efficiency of energy transfer. This in combination with the state-of-the-art OMEGA heater beams providing multiple kilojoules in a nanosecond to sufficiently heat the plasma make this system distinct from previous studies. These heater beams will provide, for the first time in Raman amplification studies, a homogeneous electron temperature high enough to prevent pump beam propagation issues that have plagued previous experiments. These systems will provide a platform for driving electron-plasma waves into the nonlinear regime where pump depletion and pulse shortening are predicted to lead to high amplification efficiencies (>30%). The Team has made significant progress through prior support from DOE Fusion Energy Sciences [DOE Office of Science Award Number DE-SC0016253 (2016-2022)]. This includes twenty-two peer-reviewed manuscripts, one patent, ten contributed talks presented at international conferences, and research that was highlighted as invited talks at fifteen international conferences. The broader impacts of this research are evident in the support of early career scientists, two Ph.D. theses, four current graduate students, a Masters Project, two undergraduate researchers, and an underrepresented minority student hired through the California Alliance for Minority Participation who now works as a Research Engineer in the group. This research met all of the funded research objectives and the highlights from primary Raman amplification thrust of this work are discussed below and form the foundation for the proposed research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Illinois Accelerator Research Center

Developing breakthroughs in accelerator science and translating them into applications for the nation’s health, wealth and security.

43 PARTICLE ACCELERATORS↗

America's Overview of Superconducting Science and Technology of Ingot Niobium

This contribution will present an overview of the results from R and D programs in the USA over the past four years towards the development of ingot Niobium as a viable alternative material to fabricate SRF cavities for particle accelerators. Activities at several laboratories and universities include fabrication, surface treatment and RF testing of single- and multi-cell cavities and studies of the thermal, mechanical and superconducting properties of samples from ingots of different purity. Possible advantages of ingot niobium over standard fine-grain (ASTM 6) are discussed and a streamlined treatment procedure to fully exploit those advantages is proposed.

36 MATERIALS SCIENCE↗

The PEPPo method for polarized positrons and PEPPo II

The Polarized Electrons for Polarized Positrons (PEPPo) experiment at the injector of the Continuous Electron Beam Accelerator Facility demonstrated for the first time the efficient transfer of polarization from electrons to positrons via a two-step process: polarized bremsstrahlung radiation is induced by a polarized electron beam in a high-Z target; then the polarized bremsstrahlung produces polarized positrons via the pair-production process in the same target. Positron polarization up to 82% was measured for an initial electron beam momentum of 8.19 MeV/c, limited only by the electron beam polarization of 85%. This technique extends polarized positron capabilities from GeV to MeV electron beams, and opens access to polarized positron beam physics to a wide community. We present the results of the PEPPo experiment and outline tentative plans for a follow-up experiment that would investigate key aspects of an approach based on PEPPo as a polarized positron source for the 12 GeV Upgrade of CEBAF.

43 PARTICLE ACCELERATORS↗

Ultra-Sensitive Measurements of 233U by Accelerator Mass Spectrometry for National Security Applications.

By making modifications to our previously established measurement setup, we increased our abundance sensitivity for {sup 233}U by three orders of magnitude and can now measure {sup 233}U/{sup 238}U ratios as low as 10{sup -13}. Because {sup 233}U has separate production pathways than {sup 236}U, it can provide valuable information on the particular source of anthropogenic uranium in a sample. We demonstrated the utility of our improved capability by using {sup 233}U to distinguish separate sources of anthropogenic uranium in a set of samples collected from a contaminated site. In the future, we plan to apply our new capability to characterizing {sup 233}U in a wide range of uranium materials.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Internal Electric Field Investigations of a Cadmium Zinc Telluride Detector Using Synchrotron X-ray Mapping and Pockels Effect Measurements

Cadmium zinc telluride (CZT) has remained a major focus of research due to its promising application as a room-temperature nuclear radiation detector material. Among the several parameters that substantially affect the detectors' performance, an important one is the distribution of the internal electric field. Brookhaven National Laboratory (BNL) employed synchrotron x-ray microscale mapping and measurements of the Pockels effect to investigate the distribution of the internal electric field in a CZT strip detector. Direct evidence that dislocations can distort the internal electric field of the detector was obtained. Furthermore, it was found that 'star' defects in the CZT crystal, possibly ascribed to dislocation loop punching, cause charge trapping.

43 PARTICLE ACCELERATORS↗

Materials Applications of Photoelectron Emission Microscopy

Photoelectron emission microscopy (PEEM) is a versatile technique that can image a variety of materials including metals, semiconductors and even insulators. Under favorable conditions the most advanced aberration corrected instruments have a spatial resolution approaching 2 nm. Although PEEM cannot compete with transmission or scanning electron microscopies for ultimate resolution, the technique is much more gentle and has the unique advantage of imaging structure as well as electronic and magnetic states on the nanoscale. Since the image contrast is derived from spatial variations in electron photoemission intensity, PEEM is ideal for interrogating both static and dynamic electronic properties of complex nanostructured materials. PEEM can be performed using a variety of photoexcitation sources including synchrotron emission, femtosecond laser pulses and conventional UV lamp emission. Each source has advantages, for example, fs laser excitation enables time-resolved imaging for study of ultrafast dynamics of surface intermediate states while tunable synchrotron sources allow chemically specific excitation. Even more detail can be extracted from energy resolved PEEM. Here, we review the key principles and contrast mechanisms of PEEM and briefly summarize materials applications of PEEM with examples of a thermally-induced structural phase transformation in barium titanate, inter-diffusion between thin metal copper and ruthenium layers, and multiphoton imaging of polystyrene nanoparticles on a silver coated substrate.

43 PARTICLE ACCELERATORS↗

Pressed copper and gold-plated copper contacts at low temperatures – A review of thermal contact resistance

Cryogenic systems that utilize cryocoolers with conduction cooling for attaining temperatures of 4.2 K and below routinely employ mechanically pressed components of copper to form the heat conduction path. To help with the design of such systems, the present paper introduces thermal contact resistance data of pressed copper-copper and gold-plated copper-copper contacts from nearly twenty measurement programs that span across past fifty years. Relevant theoretical models of thermal contact resistance are briefly reviewed and compared with the experimental data. Gold-plated copper contacts display reasonable trend with the models, which may serve as a design reference for such contacts. A few measurement techniques are also summarized that enable quick characterization of thermal contacts at low temperatures.

43 PARTICLE ACCELERATORS↗

Tensile behavior of dual-phase titanium alloys under high-intensity proton beam exposure: radiation-induced omega phase transformation in Ti-6Al-4V

A high-intensity proton beam exposure with 181 MeV energy has been conducted at Brookhaven Linac Isotope Producer facility on various material specimens for accelerator targetry applications, including titanium alloys as a beam window material. The radiation damage level of the analyzed capsule was 0.25 dpa at the beam center region with an irradiation temperature around 120 oC. Tensile tests showed increased hardness and a large decrease in ductility for the dual a+ß-phase Ti-6Al-4V Grade-5 and Grade-23 extra low interstitial alloys, with the near a-phase Ti-3Al-2.5V Grade-9 alloy still exhibiting uniform elongation of a few % after irradiation. Transmission Electron Microscope analyses on Ti-6Al-4V indicated clear evidence of a high-density of defect clusters with size less than 2 nm in each a-phase grain. The ß-phase grains did not contain any visible defects such as loops or black dots, while the diffraction patterns clearly indicated ?-phase precipitation in an advanced formation stage. The radiation-induced ?-phase transformation in the ß-phase could lead to greater loss of ductility in Ti-6Al-4V alloys in comparison with Ti-3Al-2.5V alloy with less ß-phase.google scho

Tensile Test, titanium, acclerator, proton beam↗

Characterization of Avalanche Photodiodes (APDs) for the Electromagnetic Calorimeter in the ALICE Experiment

The Electromagnetic Calorimeter (EMCal) of the ALICE experiment at LHC will extensively make use of avalanche photodiodes (APDs) for the readout of scintillation light. The large sensitive area, high quantum efficiency and low dark current make this type of photosensors well-suited for the EMCal requirements. A testing activity is currently in progress in order to characterize the main properties of these APDs and find the best working conditions. Fundamental tasks are the individual test of all APDs after presetting their nominal gain via the bias control and the study of APD gain coefficients as a function of the applied bias voltage and temperature. An overview of the adopted procedure will be presented, together with a description of preliminary results obtained on a first sample of APDs during the testing activity.

43 PARTICLE ACCELERATORS↗

Micromegas tracker project for CLAS12

Micromegas detectors on bulk are used in a new design of the central tracker for the future Cebaf Large Acceptance Spectrometer 12 (CLAS12) in Hall B at Jefferson Lab. Expected performances and mechanical designs are shown for this cylindrical detector. First tests in moderate magnetic field up to 1.5 T, using a laser source, are in good agreement with simulations.

Micro Pattern Gaseous Detectors↗

Gas cell targets for experiments with radioactive beams.

In this paper we discuss the properties of gas cell targets used for the production of radioactive beams via the in-flight technique as well as gas cell targets used for studies of nuclear reactions in inverse kinematics at the ATLAS heavy ion accelerator.

43 PARTICLE ACCELERATORS↗