Ensemble Kalman Filter for Dynamic State Estimation of Power Grids Stochastically Driven by Time-correlated Mechanical Input Power

State and parameter estimation of power transmission networks is important for monitoring power grid operating conditions and analyzing transient stability. Wind power generation depends on fluctuating input power levels, which are correlated in time and contribute to uncertainty in turbine dynamical models. The ensemble Kalman filter (EnKF), a standard state estimation technique, uses a deterministic forecast and does not explicitly model time-correlated noise in parameters such as mechanical input power. However, this uncertainty affects the probability of fault-induced transient instability and increased prediction bias. Here a novel approach is to model input power noise with time-correlated stochastic fluctuations, and integrate them with the network dynamics during the forecast. While the EnKF has been used to calibrate constant parameters in turbine dynamical models, the calibration of a statistical model for a time-correlated parameter has not been investigated. In this study, twin experiments on a standard transmission network test case are used to validate our time-correlated noise model framework for state estimation of unsteady operating conditions and transient stability analysis, and a methodology is proposed for the inference of the mechanical input power time-correlation length parameter using time-series data from PMUs monitoring power dynamics at generator buses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced multilateration theory, software development, and data processing: The MICRODOT system

The process of geometric parameter estimation to accuracies of one centimeter, i.e., multilateration, is defined and applications are listed. A brief functional explanation of the theory is presented. Next, various multilateration systems are described in order of increasing system complexity. Expected systems accuracy is discussed from a general point of view and a summary of the errors is listed. An outline of the design of a software processing system for multilateration, called MICRODOT, is presented next. The links of this software, which can be used for multilateration data simulations or operational data reduction, are examined on an individual basis. Functional flow diagrams are presented to aid in understanding the software capability. MICRODOT capability is described with respect to vehicle configurations, interstation coordinate reduction, geophysical parameter estimation, and orbit determination. Numerical results obtained from MICRODOT via data simulations are displayed both for hypothetical and real world vehicle/station configurations such as used in the GEOS-3 Project. These simulations show the inherent power of the multilateration procedure.

Escobal, P. R.↗

Data and Scripts associated with “Lambda-PFLOTRAN: Workflow for Incorporating Organic Matter Chemistry Informed by Ultra High Resolution Mass Spectrometry into Biogeochemical Modeling.”

This data package is associated with the publication “Lambda-PFLOTRAN: Workflow for Incorporating Organic Matter Chemistry Informed by Ultra High Resolution Mass Spectrometry into Biogeochemical Modeling” submitted to Geoscientific Model Development (Muller et al., 2024). In this manuscript, organic matter chemistry and thermodynamics are directly connected to reactive transport simulators through the newly developed Lambda-PFLOTRAN (Parallel Reactive Flow and Transport model) workflow tool that succinctly incorporates organic matter chemistry data generated from Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) into reaction networks to simulate aerobic respiration of the organic matter and the resulting biogeochemistry. Lambda-PFLOTRAN is a python-based workflow, executed through a Jupyter Notebook interface, that digests raw FTICR-MS data, develops a representative reaction network based on substrate-explicit thermodynamic modeling (also termed lambda modeling due to its key thermodynamic parameter λ used therein), and completes a biogeochemical simulation with the open source, reactive flow, and transport code PFLOTRAN. This data package contains Jupyter Notebook based workflows for two test cases for running biogeochemical simulations of organic matter oxidation identified by FTICR-MS. It contains four primary folders (workflow, data, src, and analysis), a file-level metadata file (Muller_2024_Lambda_PFLOTRAN_Manuscript_Data_Package_flmd.csv) that lists all the files contained in this data package with a short description of each, and a data dictionary (Muller_2024_Lambda_PFLOTRAN_Manuscript_Data_Package_dd.csv) file that describes the tabular column headers. The ‘workflow’ folder contains the Jupyter Notebook based workflows for running the lambda analysis, PFLOTRAN simulation, sensitivity analysis and parameter estimation. The ‘data’ folder contains the FTICR-MS data, initial conditions, and incubation data for test cases 1 and 2 in folders titled ‘WHONDRS’ and ‘Colloids’, respectively. The data folder also has a ‘Database’ folder containing a reaction network for bulk organic matter (assumed to be CH2O) and a general database for PFLOTRAN (hanford_rxn_network). The CH2O reaction network defines bulk organic matter oxidation. Biogeochemical simulations are completed for both the lambda binned organic matter and bulk organic matter reaction networks. The ‘hanford_rxn_network’ database includes information required for PFLTORAN simulations including ion size, molar mass, and charge of the aqueous species, gases, and minerals phases. The ‘src’ folder contains python source codes for performing lambda analysis, PFLOTRAN simulation, sensitivity analysis and parameter estimation. The ‘analysis’ folder contains outputs from the test cases 1 and 2 including lambda analysis, PFLOTRAN runs and the calibration results.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Zero-Net-Rate Pumping Tests

Accurately estimating the distribution of aquifer properties is key to understanding contaminant movement in the subsurface. The distribution of aquifer properties is typically addressed using slug or constant-rate well tests, and the pros and cons of these tests are well known. Slug tests are appealing because they avoid removing contaminated water, but their results are affected by well skin and the small volume of displaced water limits the volume of aquifer that can be evaluated. Constant-rate well tests have the disadvantage of requiring disposal of potentially contaminated water, but they can generate properties that are more representative than slug tests, and they can be used to estimate well efficiency and storativity, which are difficult to characterize using slug tests. Periodic pumping tests are appealing because they have many of the advantages and few of the disadvantages of slug and constant-rate well tests. Periodic pumping tests involve cycling the pumping rate with a regular period and measuring the resulting response in monitoring wells. Some of these tests involve imposing a periodic rate on a constant mean rate. However, other tests involve moving water out and back into the well at rates that are balanced so the net rate after each period is zero. Some zero-net-rate (ZNR) well tests use rates that follow a sinusoidal pattern, whereas others use a square wave pattern that switches between a constant rate of pumping and a constant rate of injection to achieve a zero-net rate. ZNR well tests appear to be a useful compromise between slug and constant rate tests, but methods for conducting and analyzing the results from these tests have received limited evaluation. Periodic pumping tests are typically evaluated through recorded pressure responses to a disturbance source. Recent work has demonstrated that the strain field in the vadose zone shows a response to disturbances in the underlying aquifer. Various instrument designs are available that can record vertical and horizontal strain to very precise resolutions (10-9 ε). Measuring the strain in the vadose zone can present lower costs than measuring pressure in a monitoring well, so using strain could improve the resolution of ZNR tests, as well as make these tests potentially cheaper. A ZNR periodic pumping system was constructed and used to perform tests in the Clemson, South Carolina area. The system was designed to pump and inject with a periodic square-wave, so pumping occurs at a constant rate for half the period and is followed by injection at the same rate for half the period resulting in no net gain or loss of water from the aquifer. The system is designed to generate flow rates from 1 to 3.5 gallons per minute (gpm) with a capacity of 875-gallon per half period. Pressure and strain monitoring points are located in the vicinity of the pumping well. A series of 10 ZNR periodic pumping tests were conducted at the field site, with periods ranging from 2 to 540 minutes. Pressure data were collected and recorded in four monitoring wells in various locations around the pumping well. In addition, vertical and horizontal strain and tilt data were recorded in various locations around the pumping well. Traditional aquifer tests, including slug tests and constant-rate pumping tests were conducted at the field site to provide a baseline of aquifer parameter estimates that are compared the results of ZNR tests. Pressure data measured at monitoring wells during ZNR tests were analyzed utilizing an analytical solution (Streltsova, 1988) that assumes a confined aquifer and estimates hydraulic diffusivity and transmissivity using the time lag and amplitude of the pressure signal. The storativity can be separated out from the hydraulic diffusivity using the transmissivity estimate. The time-lag and amplitude of the pressure signals were estimated using a Fourier transform. The time-lag of the primary period of the pressure increases as a linear function of distance from the pumping well, and it increases as the square root of the period of the ZNR test over a range of periods spanning two orders of magnitudes. The first few harmonics follow similar trends, but the higher frequency harmonics diverge from this trend. Strain and tilt data from various instruments in the vadose and saturated zones are periodic during ZNR tests. The time lags of the strain components increase roughly linearly with distance from the well. Many of the time lags of the strain data from the vadose zone are similar to the time lags observed in the pressure data from a similar distance and pumping period. Theoretical experiments were performed to understand how pressure and strain responds to ZNR periodic pumping. The time-lags of the simulated pressure responses match the field data trends. The results were used to validate the Streltsova (1988) solution for periodic pumping to estimate hydraulic diffusivity. Hydraulic diffusivity was estimated to be 1.8 x 10-2 m2s-1 < Dh < 9.0 x 10-2 m2s-1 using pressure data from all the wells during ZNR tests. Transmissivity was estimated to be 0.8 x 10-4 m2s-1 < T < 4.3 x 10-4 m2s-1. Assuming Storativity = T/Dh gives 1.1 x 10-3 < S < 19 x10-3. Transmissivity is used to estimate the hydraulic conductivity, K, by dividing by the assumed aquifer thickness. Two constant-rate pumping tests were conducted and analyzed using two conceptual models: The Hantush (1961) solution was used to analyze data assuming confined conditions and the Neuman (1974) solution was used to analyze data assuming unconfined conditions. The Hantush (1961) solution estimated transmissivity to be 1.6 x 10-4 m2s-1 < T < 1.8 x 10-4 m2s-1 when using data from all the wells. Storativity was estimated to be 4.4 x 10-3 < S < 8.2 x 10-3. Assuming Dh = T/S gives 0.22 x 10-2 m2s-1 < Dh < 3.6 x 10-2 m2s-1. The Neuman (1974) solution estimated transmissivity to be 0.80 x 10-4 m2s-1 < T < 0.84 x 10-4 m2s-1. Total storativity (S + Sy) was estimated to be 22 x 10-3 < S < 110 x 10-3. Storativity excluding the Sy term was estimated to be 2.2 x 10-3 < S < 2.5 x 10-3. Assuming Dh = T/S gives 0.073 x 10-2 m2s-1 < S < 0.36 x 10-2 m2s-1. Two slug tests were performed on the pumping well, PW-2. The Bouwer and Rice (1976) solution for slug tests was used to analyze the data. This solution works for both confined and unconfined conditions, so both conceptual models were covered through the analysis. Hydraulic conductivity was estimated to be 1.95 x 10-6 ms-1 < K < 2.49 x 10-6 ms-1. Statistical comparison show generally no significant difference in the estimates of Dh, K, or S made using ZNR and conventional pumping tests.. However, the total storage estimated by the Neuman (1974) solution for unconfined settings is larger than that estimate using the Streltsove analysis applied to the ZNR tests. This is likely because the Neuman solution considers delayed yield from storage that the water table, whereas the Streltsova (1988) solution assumes confined conditions. The analysis also indicates that there is a statistically significant difference between parameters estimated with conventional slug tests and those measured with either constant-rate pumping tests or ZNR tests. Hydraulic diffusivity is estimated from the time-lag and the distance from the well. The time-lags of the strain data from the vadose zone are similar to the lags of the pressure data from a similar distance. This indicates that hydraulic diffusivities estimated from the strain data measured in the vadose zone would be similar to the estimates from the pressure data measured in the aquifer. There appear to be sign reversals in some of the strain data that were corrected to estimate the time lag. The dissolved oxygen (CO) concentration was measured during several ZNR tests to evaluate the feasibility of using the procedure to increase contaminant degradation kinetics that are related to DO. The results indicate that DO can be increased during the cycling of ZNR tests in some cases.

Smith-Jones, Austin↗

MASKED AREAS IN SHEAR PEAK STATISTICS: A FORWARD MODELING APPROACH

The statistics of shear peaks have been shown to provide valuable cosmological information beyond the power spectrum, and will be an important constraint of models of cosmology in forthcoming astronomical surveys. Surveys include masked areas due to bright stars, bad pixels etc., which must be accounted for in producing constraints on cosmology from shear maps. We advocate a forward-modeling approach, where the impacts of masking and other survey artifacts are accounted for in the theoretical prediction of cosmological parameters, rather than correcting survey data to remove them. We use masks based on the Deep Lens Survey, and explore the impact of up to 37% of the survey area being masked on LSST and DES-scale surveys. By reconstructing maps of aperture mass the masking effect is smoothed out, resulting in up to 14% smaller statistical uncertainties compared to simply reducing the survey area by the masked area. We show that, even in the presence of large survey masks, the bias in cosmological parameter estimation produced in the forward-modeling process is ≈1%, dominated by bias caused by limited simulation volume. We also explore how this potential bias scales with survey area and evaluate how much small survey areas are impacted by the differences in cosmological structure in the data and simulated volumes, due to cosmic variance.

79 ASTRONOMY AND ASTROPHYSICS↗

Adaptive Urban Traffic Signal Control for Multiple Intersections: An LQR Approach

Traffic congestion leads to severe problems especially in urban traffic networks. It increases the chance of accidents, energy waste, and social costs. In order to address these problems, an adaptive linear quadratic regulator (LQR) approach is developed for traffic signal control at multiple intersections in an urban area. The proposed method controls the green time of the traffic signals to reduce traffic congestion and smooth traffic flow. Real-world data from vision-based traffic sensors are used to build the traffic network model, which mimics the real-world traffic behavior. In addition, the proposed control utilizes recursive least square parameter estimation, which is capable of tracking dynamic changes in traffic conditions. Simulation of Urban MObility (SUMO) is used to analyze the efficacy of the proposed method. Results of the simulation show that the proposed method outperforms pretimed control in various aspects.

adaptive LQR control↗

Time-lapse seismic data inversion for estimating reservoir parameters using deep learning

Geologic carbon sequestration involves the injection of captured carbon dioxide ([Formula: see text]) into subsurface formations for long-term storage. The movement and fate of the injected [Formula: see text] plume is of great concern to regulators because monitoring helps to identify potential leakage zones and determines the possibility of safe long-term storage. To address this concern, we design a deep-learning framework for [Formula: see text] saturation monitoring to determine the geologic controls on the storage of the injected [Formula: see text]. We use different combinations of porosities and permeabilities for a given reservoir to generate saturation and velocity models. We train the deep-learning model with a few time-lapse seismic images and their corresponding changes in saturation values for a particular [Formula: see text] injection site. The deep-learning model learns the mapping from the change in the time-lapse seismic response to the change in [Formula: see text] saturation during the training phase. We then apply the trained model to data sets comprising different time-lapse seismic image slices (corresponding to different time instances) generated using different porosity and permeability distributions that are not part of the training to estimate the [Formula: see text] saturation values along with the plume extent. Our algorithm provides a deep-learning assisted framework for the direct estimation of [Formula: see text] saturation values and plume migration in heterogeneous formations using the time-lapse seismic data. Our method improves the efficiency of time-lapse inversion by streamlining the large number of intermediate steps in the conventional time-lapse inversion workflow. This method also helps to incorporate the geologic uncertainty for a given reservoir by accounting for the statistical distribution of porosity and permeability during the training phase. Tests on different examples verify the effectiveness of our approach.

Geochemistry & Geophysics↗

Pile noise experiment in MINERVE reactor to estimate kinetic parameters using various data processing methods

MINERVE is a two-zone pool type zero power reactor operated by CEA (Cadarache, France). Kinetic parameters of the core (prompt neutron decay constant, delayed neutron fraction, generation time) have been recently measured using various pile noise experimental techniques, namely Feynman-α, Rossi-α and Cohn-α. Results are discussed and compared to each other's. The measurement campaign has been conducted in the framework of a tri-partite collaboration between CEA, SCK.CEN and PSI. Results presented in this paper were obtained thanks to a time-stamping acquisition system developed by CEA. PSI performed simultaneous measurements which are presented in a companion paper. Signals come from two high efficiency fission chambers located in the graphite reflector next to the core driver zone. Experiments were conducted at critical state with a reactor power of 0.2 W. The core integral fission rate is obtained from a calibrated miniature fission chamber located at the center of the core. Other results obtained in two sub-critical configurations will be presented elsewhere. Best estimate delayed neutron fraction comes from the Cohn-α method: 747 ± 15 pcm (1σ). In this case, the prompt decay constant is 79 ± 0.5 s{sup -1} and the generation time is 94.5 ± 0.7 μs. Other methods give consistent results within the confidence intervals. Experimental results are compared to calculated values obtained from a full 3D core modeling with the CEA-developed Monte Carlo code TRIPOLI4.9 associated with its continuous energy JEFF3.1.1-based library. A very good agreement is observed for the calculated delayed neutron fraction (748.7 ± 0.4 pcm at 1σ), that is a difference of -0.3% with the experiment. On the contrary, a 10% discrepancy is observed for the calculated generation time (104.4 ± 0.1 μs at 1σ). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensor Fault Detection and Diagnosis Simulation of a Helicopter Engine in an Intelligent Control Framework

This paper presents an application of a fault detection and diagnosis scheme for the sensor faults of a helicopter engine. The scheme utilizes a model-based approach with real time identification and hypothesis testing which can provide early detection, isolation, and diagnosis of failures. It is an integral part of a proposed intelligent control system with health monitoring capabilities. The intelligent control system will allow for accommodation of faults, reduce maintenance cost, and increase system availability. The scheme compares the measured outputs of the engine with the expected outputs of an engine whose sensor suite is functioning normally. If the differences between the real and expected outputs exceed threshold values, a fault is detected. The isolation of sensor failures is accomplished through a fault parameter isolation technique where parameters which model the faulty process are calculated on-line with a real-time multivariable parameter estimation algorithm. The fault parameters and their patterns can then be analyzed for diagnostic and accommodation purposes. The scheme is applied to the detection and diagnosis of sensor faults of a T700 turboshaft engine. Sensor failures are induced in a T700 nonlinear performance simulation and data obtained are used with the scheme to detect, isolate, and estimate the magnitude of the faults.

Litt, Jonathan↗

Timing gamma-ray pulsars with the Fermi large area telescope: Timing noise and astrometry

We have constructed timing solutions for 81 γ-ray pulsars covering more than five years of Fermi data. The sample includes 37 radio-quiet or radio-faint pulsars which cannot be timed with other telescopes. These timing solutions and the corresponding pulse times of arrival are prerequisites for further study, e.g., phase-resolved spectroscopy or searches for mode switches. Many γ-ray pulsars are strongly affected by timing noise (TN), and we present a new method for characterizing the noise process and mitigating its effects on other facets of the timing model. We present an analysis of TN over the population using a new metric for characterizing its strength and spectral shape, namely, its time-domain correlation. The dependence of the strength on ν and ν-dot is in good agreement with previous studies. We find that noise process power spectra S(f) for unrecycled pulsars are steep, with strong correlations over our entire data set and spectral indices S(f)∝f{sup −α} of α ∼ 5–9. One possible explanation for these results is the occurrence of unmodeled, episodic “microglitches.” Finally, we show that our treatment of TN results in robust parameter estimation, and in particular we measure a precise timing position for each pulsar. We extensively validate our results with multi-wavelength astrometry, and using our updated position, we firmly identify the X-ray counterpart of PSR J1418−6058.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimal sensing on an asymmetric exceptional surface

We study the connection between exceptional points (EPs) and optimal parameter estimation, in a simple system consisting of two counterpropagating traveling wave modes in a microring resonator. The unknown parameter to be estimated is the strength of a perturbing cross-coupling between the two modes. Partially reflecting the output of one mode into the other creates a non-Hermitian Hamiltonian that exhibits a family of EPs, creating an exceptional surface (ES). We use a fully quantum treatment of field inputs and noise sources to obtain a quantitative bound on the estimation error by calculating the quantum Fisher information (QFI) in the output fields, whose inverse gives the Cramér-Rao lower bound on the mean-squared error of any unbiased estimator. We determine the bounds for two input states, namely, a semiclassical coherent state and a highly nonclassical NOON state. We find that the QFI is enhanced in the presence of an EP for both of these input states and that both states can saturate the Cramér-Rao bound. We then identify idealized yet experimentally feasible measurements that achieve the minimum bound for these two input states. We also investigate how the QFI changes for parameter values that do not lie on the ES, finding that these can have a larger QFI, suggesting alternative routes to optimize the parameter estimation for this problem.

Exceptional points↗

Unsteady Aerodynamic Force Sensing from Measured Strain

A simple approach for computing unsteady aerodynamic forces from simulated measured strain data is proposed in this study. First, the deflection and slope of the structure are computed from the unsteady strain using the two-step approach. Velocities and accelerations of the structure are computed using the autoregressive moving average model, on-line parameter estimator, low-pass filter, and a least-squares curve fitting method together with analytical derivatives with respect to time. Finally, aerodynamic forces over the wing are computed using modal aerodynamic influence coefficient matrices, a rational function approximation, and a time-marching algorithm. A cantilevered rectangular wing built and tested at the NASA Langley Research Center (Hampton, Virginia, USA) in 1959 is used to validate the simple approach. Unsteady aerodynamic forces as well as wing deflections, velocities, accelerations, and strains are computed using the CFL3D computational fluid dynamics (CFD) code and an MSC/NASTRAN code (MSC Software Corporation, Newport Beach, California, USA), and these CFL3D-based results are assumed as measured quantities. Based on the measured strains, wing deflections, velocities, accelerations, and aerodynamic forces are computed using the proposed approach. These computed deflections, velocities, accelerations, and unsteady aerodynamic forces are compared with the CFL3D/NASTRAN-based results. In general, computed aerodynamic forces based on the lifting surface theory in subsonic speeds are in good agreement with the target aerodynamic forces generated using CFL3D code with the Euler equation. Excellent aeroelastic responses are obtained even with unsteady strain data under the signal to noise ratio of -9.8dB. The deflections, velocities, and accelerations at each sensor location are independent of structural and aerodynamic models. Therefore, the distributed strain data together with the current proposed approaches can be used as distributed deflection, velocity, and acceleration sensors. This research demonstrates the feasibility of obtaining induced drag and lift forces through the use of distributed sensor technology with measured strain data. An active induced drag control system thus can be designed using the two computed aerodynamic forces, induced drag and lift, to improve the fuel efficiency of an aircraft. Interpolation elements between structural finite element grids and the CFD grids and centroids are successfully incorporated with the unsteady aeroelastic computation scheme. The most critical technology for the success of the proposed approach is the robust on-line parameter estimator, since the least-squares curve fitting method depends heavily on aeroelastic system frequencies and damping factors.

shape sensing↗

Cosmology From CMB Lensing and Delensed EE Power Spectra Using 2019-2020 SPT-3G Polarization Data

From CMB polarization data alone we reconstruct the CMB lensing power spectrum, comparable in overall constraining power to previous temperature-based reconstructions, and an unlensed E -mode power spectrum, with clear detections of the third through tenth acoustic peaks. The observations, taken in 2019 and 2020 with the South Pole Telescope (SPT) and the SPT-3G camera, cover 1500 deg 2 at 95, 150, and 220 GHz with arcminute resolution and roughly 4.9 µ K-arcmin coadded noise in polarization. The power spectrum estimates, together with systematic parameter estimates and a joint covariance matrix, follow from a Bayesian analysis using the Marginal Unbiased Score Expansion (MUSE) method. The E -mode spectrum at ℓ > 2000 and lensing spectrum at L > 350 are the most precise to date. Assuming the ΛCDM model, and using only these SPT data and priors on τ and absolute calibration from Planck, we find H 0 = 66.81 ± 0.81 km/s/Mpc, comparable in precision to the Planck determination and in 5.4 σ tension with the most precise H 0 inference derived via the distance ladder. We also find S 8 ≡ σ 8 (Ω m /0.3) 0.5 = 0.850 ± 0.017, providing further independent evidence of a slight tension with low-redshift structure probes. The ΛCDM model provides a good simultaneous fit to the combined Planck, ACT, and SPT data, and thus passes a powerful test. Combining these CMB datasets with BAO observations, we explore extensions to the ΛCDM model. We find that the effective number of neutrino species, spatial curvature, and primordial helium fraction are consistent with standard model values, and that the 95% confidence upper limit on the neutrino mass sum is 0.075 eV, close to the minimum sum expected from observations of solar and atmospheric neutrino oscillations. The SPT data are consistent with the somewhat weak (< 3 σ ) preference for excess lensing power seen in Planck and ACT data relative to predictions of the ΛCDM model given the combined Planck, ACT, and BAO data sets. Finally, we also detect at greater than 3 σ the influence of non-linear evolution in the CMB lensing power spectrum and discuss it in the context of the S 8 tension. Forthcoming SPT-3G analyses will feature deeper and wider observations in temperature and polarization, providing even tighter constraints and more powerful tests of the ΛCDM model.

79 ASTRONOMY AND ASTROPHYSICS↗

Selective Photothermolysis to target Sebaceous Glands: Theoretical Estimation of Parameters and Preliminary Results Using a Free Electron Laser

The success of permanent laser hair removal suggests that selective photothermolysis (SP) of sebaceous glands, another part of hair follicles, may also have merit. About 30% of sebum consists of fats with copious CH2 bond content. SP was studied in vitro, using free electron laser (FEL) pulses at an infrared CH2 vibrational absorption wavelength band. Absorption spectra of natural and artificially prepared sebum were measured from 200 nm to 3000 nm, to determine wavelengths potentially able to target sebaceous glands. The Jefferson National Accelerator superconducting FEL was used to measure photothermal excitation of aqueous gels, artificial sebum, pig skin, human scalp and forehead skin (sebaceous sites). In vitro skin samples were exposed to FEL pulses from 1620 to 1720 nm, spot diameter 7-9.5 mm with exposure through a cold 4C sapphire window in contact with the skin. Exposed and control tissue samples were stained using H and E, and nitroblue tetrazolium chloride staining (NBTC) was used to detect thermal denaturation. Natural and artificial sebum both had absorption peaks near 1210, 1728, 1760, 2306 and 2346 nm. Laser-induced heating of artificial sebum was approximately twice that of water at 1710 and 1720 nm, and about 1.5x higher in human sebaceous glands than in water. Thermal camera imaging showed transient focal heating near sebaceous hair follicles. Histologically, skin samples exposed to {approx}1700 nm, {approx}100-125 ms pulses showed evidence of selective thermal damage to sebaceous glands. Sebaceous glands were positive for NBTC staining, without evidence of selective loss in samples exposed to the laser. Epidermis was undamaged in all samples. Conclusions: SP of sebaceous glands appears to be feasible. Potentially, optical pulses at {approx}1720 nm or {approx}1210 nm delivered with large beam diameter and appropriate skin cooling in approximately 0.1 s may provide an alternative treatment for acne.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental workflow to estimate model parameters for evaluating long term viscoelastic response of CO2 storage caprocks

Understanding the time-dependent behavior of reservoir and sealing formations is critical to assessing risks associated with geological carbon storage since time-dependent deformation strongly influences mechanical responses of some rock types. Many studies have evaluated the risk of CO2 leakage and induced seismicity by assuming poroelastic rheology in sealing formations. Few have considered viscoelastic or other time-dependent responses, where the existing literature adopts 1D models to represent long-term time-dependent responses. This is primarily because to date, the general form of a reasonable 3D time-dependent model for rocks remains unclear. In this paper, we address this unclear issue by proposing a new workflow to select constitutive modeling parameters to evaluate if a 3D viscoelastic model is reasonable using several-hour-long experimental data and a power-law response to extrapolate to the decades-long time frames of interest in geologic carbon storage. To provide experimental data, we conducted multi-level loading/unloading triaxial relaxation tests with four rock types. The experimental results showed that the maximum load relaxation observed is approximately 49%, with some rock types showing as little as 1.4%. Using a simple linear viscoelastic model, parameters were chosen such that a maximum deviation of 1.5 MPa in axial stress and 7 MPa in radial stress was attained with the extrapolated 30-year data. We found that a reasonable parameter range for the normalized elastic modulus is 0.1~2 for rocks with significant time-dependent responses and 0.01~0.06 for those with small time-dependent responses. No matter how significant time-dependent responses are for rocks considered, our results showed that the relaxation time has a general range of 1~10^10 s, whose time scale can be one or two orders higher than a time frame typically envisioned for CO2 injection projects.

Stress relaxation, 3D time-dependent model, viscoe↗