Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Spectral Rear Irradiance Testing and Modeling for Degradation and Performance of Solar Fields

This work investigates how the spectrum of irradiance incident on the rear of solar modules impacts the degradation and performance of backsheets. We model the spectral irradiance incident on the rear of modules through raytrace simulations and validate with measured field data collected from a 75kW single axis-tracked bifacial test site. A generic equation to estimate relative degradation is proposed, and we show that current acceleration factors for UV damage in chambers can be sub-estimate up to 4.5% absolute from the usually assumed 10% dosage on the rear surfaces.

bifacial performance↗

Human Health Risk Assessment for Improper Landfill Disposal of End-of-Life CdTe PV

The present work is a continuation of the 2020 IEA PVPS Task 12 Human Health Risk Assessment Methods for PV Part 3: Module Disposal Risks. The 2020 report performed a human health risk assessment (HHRA) for disposal of a cadmium telluride (CdTe) PV module in an unlined landfill, focusing solely on risks from cadmium. This study extends the 2020 HHRA on CdTe PV, analyzing eleven constituent elements: Cd, Se, Te, Cu, Si, Cr(III), Mo, Sn, Zn, Ni, and Al. The present HHRA was performed through two methods: utilization of the U.S. Environmental Protection Agency's (USEPA) Delisting Risk Assessment Software (DRAS V.4.0) on eight exposure pathways for cancer risk and non-cancer hazards; and comparison of exposure point concentrations to federal standards for groundwater, surface water, air, and soil exposure pathways. Cancer risks and non-cancer hazards posed by elemental leaching through all evaluated exposure pathways, using both methods, were found to be several orders of magnitude below USEPA health-protective thresholds. Cadmium exhibited both the highest risks and lowest uncertainty considering data availability on chemical content, leachate, and federal screening levels.

chemicals↗

Human Health Risk Assessment for Improper Landfill Disposal of End-of-Life CdTe Modules

The present work is a continuation of the 2020 IEA PVPS Task 12 Human Health Risk Assessment Methods for PV Part 3: Module Disposal Risks. The 2020 report performed a human health risk assessment (HHRA) for disposal of a cadmium telluride (CdTe) PV module in an unlined landfill, focusing solely on risks from cadmium. This study extends the 2020 HHRA on CdTe PV, analyzing eleven constituent elements: Cd, Se, Te, Cu, Si, Cr(III), Mo, Sn, Zn, Ni, and Al. The present HHRA was performed through two methods: utilization of the U.S. Environmental Protection Agency's (USEPA) Delisting Risk Assessment Software (DRAS V.4.0) on eight exposure pathways for cancer risk and non-cancer hazards; and comparison of exposure point concentrations to federal standards for groundwater, surface water, air, and soil exposure pathways. Cancer risks and non-cancer hazards posed by elemental leaching through all evaluated exposure pathways, using both methods, were found to be several orders of magnitude below USEPA health-protective thresholds. Cadmium exhibited both the highest risks and lowest uncertainty considering data availability on chemical content, leachate, and federal screening levels.

CdTe↗

Analyze Landscape of Solar Panel Installations and Retirements - Solar Prize Round 7 (CRADA CRD-24-30364 Final Report)

By projecting the solar capacity until 2050 at a granular, census tract level, we aim to define Participant's Total Addressable Market for Electra's registration service and examine the volumes and locations of panels reaching end-of-life with corresponding state policies and planned recycling locales. This dual-faceted data will be pivotal in developing a sustainable, per-watt pricing strategy for our state central funds and key areas for collection hubs, ensuring these volumes can adequately support our collection, hauling, and recycling provider network.

14 SOLAR ENERGY↗

A review and summary of cell and module mismatch losses from theoretical and experimental studies

Studies on power loss due to photovoltaic (PV) cell and module parameter mismatch were reviewed. The losses result from the current voltage (I-V) characteristics of cells which vary over a manufactured lot. The peak power and the peak power I-V point vary from cell to cell. The largest parameter variation occurs in the cell photocurrent generation and the most significant loss occurs in series connections since all cells are essentially limited by the lowest photocurrent. Most theoretical studies address only photocurrent variation effects, which consider shunt and series resistance, ideality factor and saturation current to be comparatively insignificant. One study is identified which specifically configured the study of mismatch loss effects. Experimental results consist of estimates based on limited data not taken from specially configured tests.

Lambarski, T. J.↗

Enhanced deep neural networks with transfer learning for distribution LMP considering load and PV uncertainties

As the flexibility of generation and demand increases in distribution systems, the residential loads are emerging as a promising means to participate in demand response and the transactive energy market. Market pricing is an instrumental mechanism for the distribution system operator to exploit the full potential of the flexible resources. The distribution locational marginal price (DLMP) can be used to guide the residential load consumption. This type of market signal helps the distribution system operator to optimize the scheduling of all resources while satisfying related network constraints through a day-ahead market. However, solving the optimization problem for large-scale systems can be computationally expensive. To address the scalability and practicability limitations of the DLMP framework, a learning-based approach is proposed in this paper to complement the day-ahead distribution market framework. Here, the proposed approach combines long short-term memory and transfer learning to develop deep neural network that can capture the spatial–temporal correlation of the input data. The model can determine the optimal DLMP for each node in a distribution system without the system parameters required to formulate the optimization problem. Testing results on IEEE 33-bus and 123-bus systems show that the proposed approach can generate a comparable DLMP against the optimization solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A study of Cell Cracks Formation During Freight Shipping : Monitoring Shock and Temperature in Real-Time & Assessing Damages With Pre and Post-Transit Characterizations of PV Modules

The solar photovoltaic (PV) industry often experiences module damage during transportation. PV modules stacked horizontally and strapped on wooden pallets may develop failures impacting their efficiency (glass shattering, cracks, frame indentation, etc.), especially when modules are not packed by professionals. The appearance of failures during the shipment from one laboratory to another can be detrimental to research studies. In this study, we tested a reusable plastic pallet designed to ship modules vertically. Five technologies of commercial PV modules were shipped together from Arizona to Florida including: glass/glass bifacial modules (framed and frameless), glass/transparent backsheet bifacial modules and glass/white backsheet modules (framed). Each module technology has a different physical size. Some modules had pre-existing cell-cracks allowing for the study of cell-crack formation and propagation during shipment. Dark current-voltage (I-V), light I-V and electroluminescence characterization were performed before and after shipment. A datalogger was used to monitor shocks and ambient temperature throughout the shipment and identify when the modules were more susceptible to damage. The modules were tilted upon receipt and the pallet were damaged but with no shattered modules. Time series shock data provided by the datalogger were used to determine potential responsible events. Our results reveal a few new post-transportation cracks for some modules. Modules parameters before and after shipment are also compared regarding the module constructions and their position in the pallet.

14 SOLAR ENERGY↗

Rapid QSTS Simulations for High-Resolution Comprehensive Assessment of Distributed PV

The rapid increase in penetration of distributed energy resources on the electric power distribution system has created a need for more comprehensive interconnection modeling and impact analysis. Unlike conventional scenario-based studies, quasi-static time-series (QSTS) simulations can realistically model time-dependent voltage controllers and the diversity of potential impacts that can occur at different times of year. However, to accurately model a distribution system with all its controllable devices, a yearlong simulation at 1-second resolution is often required, which could take conventional computers a computational time of 10 to 120 hours when an actual unbalanced distribution feeder is modeled. This computational burden is a clear limitation to the adoption of QSTS simulations in interconnection studies and for determining optimal control solutions for utility operations. The solutions we developed include accurate and computationally efficient QSTS methods that could be implemented in existing open-source and commercial software used by utilities and the development of methods to create high-resolution proxy data sets. This project demonstrated multiple pathways for speeding up the QSTS computation using new and innovative methods for advanced time-series analysis, faster power flow solvers, parallel processing of power flow solutions and circuit reduction. The target performance level for this project was achieved with year-long high-resolution time series solutions run in less than 5 minutes within an acceptable error.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fort Mojave Indian Tribe Aha Macav Power Service Renewable Energy Project

Aha Macav Power Service (AMPS), on behalf of the Fort Mojave Indian Tribe received a Department of Energy Solar grant. Partnering with Stockbridge Energy Group and the Department of Energy, AMPS was able to construct, install, test and successfully put into operation a 2.3 MW solar field. As provided in the solar data, this project has helped to offset the cost of open market purchase power needed to meet the needs of the Tribe. The estimated value of the solar energy produced in FY2021 currently is more than $294,000. Eventual expansion of the solar project is projected to create future energy independence for the Fort Mojave Indian Tribe.

14 SOLAR ENERGY↗

Land-Based Wind Market Report: 2022 Edition

The U.S. Department of Energy's 2022 edition of its Land-Based Wind Market Report provides an overview of key trends in the U.S. wind power market, with a focus on 2021. You can find a report, data file and presentation on the Files tab, below. Additionally, several data visualizations are available on the Visualizations tab. Despite ongoing supply chain challenges, wind energy in 2021 continued to see strong growth, technology improvements, and low prices in the U.S. Key highlights include: Wind comprises a growing share of electricity supply: U.S. wind power capacity grew at a strong pace in 2021, with the 13.4 GW of new additions representing a $\$20$ billion investment and 32% of all newly added U.S. generation capacity. Wind energy output rose to account for more than 9% of the entire nation’s electricity supply. At least 247 GW of wind are seeking transmission interconnection; 77 GW of this capacity are offshore wind and 19 GW are hybrid plants that pair wind with storage or solar PV. Wind project performance has increased over the decades: The average capacity factor among recently built projects was nearly 40%, considerably higher than projects built earlier. The highest capacity factors are seen in the interior ‘wind belt’ of the country. Turbines continue to get larger: Improved plant performance has been driven by larger turbines mounted on taller towers and featuring longer blades. In 2011, no turbines employed blades that were 115 meters in diameter or larger, but in 2021, 89% of newly installed turbines featured such rotors. Proposed projects indicate that total turbine height will continue to rise. Low wind turbine pricing has pushed down installed project costs over the last decade: Wind turbine prices averaged $\$800$–$\$950$/kW in 2021, a 5% to 10% increase from the year prior but substantially lower than in 2010. The average installed cost of wind projects in 2021 was $\$1,500$/kW, down more than 40% since the peak in 2010, though relatively stable in recent years. The lowest costs were found in Texas and the (non-ISO) West. Wind energy prices are on the rise, but generally remain low, around $\$20$/MWh in the interior of the country with higher prices in the West and East. After topping out above $\$75$/MWh for power purchase agreements (PPAs) executed in 2009, the national average price of wind PPAs has dropped—though supply-chain pressures have resulted in increased prices in recent years. In the interior ‘wind belt’ of the country, recent pricing is around $\$20$/MWh. In the West and East, prices tend to average above $\$30$/MWh. These prices, which are possible in part due to federal tax support, fall below the projected future fuel costs of gas-fired generation. Wind PPA prices are often attractive compared to wind’s grid-system market value: The value of wind in wholesale power markets is affected by the location of wind plants, their hourly output profiles, and how those characteristics correlate with real-time electricity prices and capacity markets. The market value of wind increased in 2021, averaging $\$16$/MWh in MISO, $\$19$/MWh in SPP, $\$23$/MWh in NYISO, $\$31$/MWh in ERCOT, $\$33$/MWh in PJM, $\$44$/MWh in ISO-NE, and $\$48$/MWh in CAISO. The average levelized cost of wind energy was $\$32$/MWh for plants built in 2021: Levelized costs, which exclude the impacts of federal tax incentives, vary across time and geography. The national average stood at $\$32$/MWh in 2021—down substantially historically, though relatively stable in recent years. Levelized costs were lowest in ERCOT, SPP, and the (non-ISO) West. The health and climate benefits of wind in 2021 were larger than its grid-system value, and the combination of all three far exceeds the current levelized cost of wind: Wind generation reduces power-sector emissions of carbon dioxide, nitrogen oxides, and sulfur dioxide. These reductions, in turn, provide public health and climate benefits that vary regionally, but together are economically valued at an average of over $\$90$/MWh-wind for plants built in 2021.

17 WIND ENERGY↗

The evolution dynamical processes of Ural blocking through the lens of local finite-amplitude wave activity budget analysis

Understanding the formation and evolution mechanisms of Ural blocking (UB) is of great importance for the prediction of UB and relevant extremes in east Asia. Using the 6-hourly ERA-Interim reanalysis data, this study quantifies the conservative and nonconservative processes in the lifecycle of UB through the lens of the hybrid Eulerian-Lagrangian local finite-amplitude wave activity (LWA) diagnostics. It is found that (i) as a wave activity source, eddy heat flux works to not only initiate the UB, but also prevent the wave activity of the blocking from dispersing downstream---the key characteristic of blocking; (ii) both the wave propagation and wave advection mechanisms are indispensable for the evolution of UB, playing a tug-of-war on the downstream development of wave activity; (iii) Throughout the lifespan of UB, diabatic heating provides the most important damping mechanism for the wave activity both upstream and downstream; and (IV) irreversible PV mixing appears to compensate the eddy PV flux during the wave breaking stage of blocking.

Blocking, wave activity, eddy-mean flow interactio↗

LDES-Sizing-and-siting-model (Power grid test cases for long-duration energy storage (LDES) siting) [SWR-25-75]

This repository contains code and data for performing a siting analysis of long-duration energy storage (LDES) in the 5-bus and RTS systems using the Sienna suite developed by the National Renewable Energy Laboratory for production cost modeling (PCM). This analysis involves moving the LDES component to different buses in the system, running a simulation, and considering the production cost of the simulation. Different system configurations are also analyzed with these scripts (such as moving load or renewable dispatch generators to different buses) to observe the impacts the system configuration has on optimal siting. This repository contains three sub directories discussed below. Both the 5-bus and RTS systems have two different initial configurations for the renewable energy components in them, one that is predominantly PV-driven and one that is predominantly wind-driven. Sienna suite can be found here: https://github.com/NREL-Sienna

Cole, David [University of Wisconsin]↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for C-AST. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed immediately once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure occurring in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy). Chemical composition analysis included: energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

balance of systems↗

Extracting and Generating PV Soiling Profiles for Analysis, Forecasting, and Cleaning Optimization

The identification and prediction of the daily soiling profiles of a photovoltaic site is essential to plan the optimal cleaning schedule. In this article, we analyze and propose various methods to extract and generate photovoltaic soiling profiles, in order to improve the analysis and the forecast of the losses. New soiling rate extraction methods are proposed to reflect the seasonal variability of the soiling rates and, for this reason, are found to identify the most convenient cleaning day with the highest accuracy for the investigated sites. Also, we present an approach that could be used to predict future soiling losses through the implementation of stochastic weather generation algorithms whose ability to identify in advance the best cleaning schedule is also successfully tested. The methods presented in this article can optimize the operation and maintenance schedule and could make it possible, in the future, to predict soiling losses through analysis based only on environmental parameters, such as rainfall and particulate matter, without the need of long-term soiling data.

14 SOLAR ENERGY↗

Voltage mapping and local defects identification in solar cells using non-contact method

Electroluminescence, infrared imaging, and current–voltage curve techniques are used to detect and map underperforming cells in a photovoltaic module or the modules in a photovoltaic string. In this work, we present a non-contact electrostatic voltmeter technique to detect and map the underperforming spots in a cell and the cells in a module. This non-contact technique directly maps the charged surface voltage (671mV) of the superstrate glass, and it had an 11-mV difference with the voltmeter values (660mV). Another data set of voltage values obtained by electroluminescence images conversion into a voltage map showed a difference of 7mV with the non-contact voltmeter values. Further, the direct voltage values obtained at various good and poor-performing spots of the cells using this technique are 3.69V and 3.79V and are validated using the voltage values obtained in electroluminescence analysis and the difference in voltage obtained by the two techniques is determined to be less than 2%. In this work, we combine the strengths of two complementary techniques of the electrostatic voltmeter (strength: quantitative) and electroluminescence (strength: spatial mapping) to obtain a quantitative spatial mapping of defects. Furthermore, this work is extendable to detect the poor-performing modules in solar PV power plants.

14 SOLAR ENERGY↗

Integration of a DER Management System in Riverside. Final report

The tasks in this project covered various aspects, including algorithm development, algorithm integration into a commercial Active Network Management (ANM) platform, hardware-in-the-loop (HIL) testing in an industry-standard testing platform, pilot demonstration in Riverside, California, and also cost and benefit analysis. The DERMS platform in this project can host different algorithms developed on different platforms (e.g., MATLAB and Python) and it can interact with different hardware devices (e.g., different PV inverters, battery inverters, and different sensors). The DER control solution are based on an advanced model-free, layered, and clustered DER control paradigm. At the core of the DER control algorithms was the concept of Extremum Seeking (ES), which is a model-free probing-based control technique. The ES-based control algorithms were tested on major real-world inverters; both individually and in a cluster. It was shown that even legacy equipment (or when paired with a few additional advanced equipment) can support such advanced control. The monitoring algorithms utilize a heterogeneous set of legacy and advanced sensor measurements, such as behind-the-meter DER sensors, distribution-level Phase Measurement Units, distribution-substation Supervisory Control and Data Acquisition (SCADA), and line current sensors, with their limited availability; in order to infer practical network conditions. Sensor data are utilized to achieve resource forecasting, phase identification, and distribution system state estimation. The technology that was developed and demonstrated in this project could be transformational to utilities, including the smaller municipal utilities such as in Riverside, which may not have the resources to deploy advanced distribution system and DERMS solutions in order to support high penetration of solar power integration. This project created a real-world prototype to provide utilities with an assessment of smart grid monitoring and control technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 degrees C from ~40 degrees C) and a different failure mode were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy).

balance of systems↗