Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

A simple, highly efficient route to electroless gold plating on complex 3D printed polyacrylate plastics

Here, compared to tedious, multi-step treatments for electroless gold plating of traditional thermoplastics, this communication describes a simpler three-step procedure for 3D printed crosslinked polyacrylate substrates. This allows for the synthesis of ultralight gold foam microlattice materials with great potential for architecture-sensitive applications in future energy, catalysis, and sensing.

36 MATERIALS SCIENCE↗

A Bremsstrahlung spectrometer using k-edge and differential filters with image plate dosimeters

A Bremsstrahlung spectrometer using k-edge and differential filtering has been used with image plate dosimeters to measure the x-ray fluence from short-pulse laser/target interactions. An electron spectrometer in front of the Bremsstrahlung spectrometer deflects electrons from the x-ray line of sight and simultaneously measures the electron spectrum. The response functions were modeled with the Monte Carlo code INTEGRATED TIGER SERIES 3.0 and the dosimeters calibrated with radioactive sources. An electron distribution with a slope temperature of 1.3 MeV is inferred from the Bremsstrahlung spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement and modeling of pulsed microchannel plate operation (invited)

Microchannel plates (MCPs) are a standard detector for fast-framing x-ray imaging and spectroscopy of high-temperature plasmas. The MCP is coated with conductive striplines that carry short duration voltage pulses to control the timing and amplitude of the signal gain. This gain depends on the voltage to a large exponent so that small reflections or impedance losses along the striplines can have a significant impact on the position-dependent amplitude and pulse width of the gain. Understanding the pulsed gain response therefore requires careful measurements of the position- and time-dependent surface voltage coupled with detailed modeling of the resulting electron cascade. We present measurements and modeling of the time- and space-dependent gain response of MCP detectors designed for use at Sandia National Laboratories' Z facility. The pulsed gain response is understood through measurements using a high impedence probe to determine the voltage pulse propagating along the stripline surface. Coupling the surface voltage measurements with Monte Carlo calculations of the electron cascade in the MCP provides a prediction of the time- and position-dependent gain that agrees with measurements made on a subpicosecond UV laser source to within the 25% uncertainty in the simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Au transmission photocathode on a microchannel plate detector

X-ray framing cameras, employing microchannel plates (MCPs) for detection and signal amplification, play a key role in research in high-energy-density physics. These instruments convert radiographic x-rays into electrons produced by plasma during such experiments into electrons that are amplified in the channels and then detected by a phosphor material. The separation of detection from signal amplification offers potential improvements in sensitivity and noise properties. We have implemented a suspended Au transmission photocathode (160 A thick) on a MCP and are evaluating it using a 1.5 keV Al K{alpha} x-ray source. We find an approximately twofold increase in the ratio of detected events to incident photons when the photocathode-to-MCP voltage difference is sufficiently large. Our calculations indicate that this increase is probably caused by a combination of signal produced by the photocathode and an increase in the efficiency of detection of x-rays that reach the MCP surface through modification of the local electric field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of Ultra-Slow Antiprotons using Micro-channel Plate

Our group ASACUSA-MUSASHI has succeeded in accumulating several million antiprotons and extracting them as monochromatic ultra-slow antiproton beams (10 eV-1 keV) at CERN AD. We have observed ultra-slow antiprotons using micro-channel plates (MCP). The integrated pulse area of the output signals generated when the MCP was irradiated by ultra-slow antiprotons was 6 times higher than that by electrons. As a long-term effect, we also observed an increase in the background rate presumably due to the radioactivation of the MCP surface. Irradiating the antiproton beams on the MCP induces antiproton-nuclear annihilations only on the first layer of the surface. Low-energy and short-range secondary particles like charged nuclear fragments caused by the 'surface nuclear reactions' would be the origin of our observed phenomena.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development and calibration of a Thomson parabola with microchannel plate for the detection of laser-accelerated MeV ions

This article reports on the development and application of a Thomson parabola (TP) equipped with a (90x70) mm{sup 2} microchannel-plate (MCP) for the analysis of laser-accelerated ions, produced by a high-energy, high-intensity laser system. The MCP allows an online measurement of the produced ions in every single laser shot. An electromagnet instead of permanent magnets is used that allows the tuning of the magnetic field to adapt the field strength to the analyzed ion species and energy. We describe recent experiments at the 100 TW laser facility at the Laboratoire d'Utilization des Lasers Intenses (LULI) in Palaiseau, France, where we have observed multiple ion species and charge states with ions accelerated up to 5 MeV/u (O{sup +6}), emitted from the rear surface of a laser-irradiated 50 {mu}m Au foil. Within the experiment the TP was calibrated for protons and for the first time conversion efficiencies of MeV protons (2-13 MeV) to primary electrons (electrons immediately generated by an ion impact onto a surface) in the MCP are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose profile measurement using an imaging plate: Evaluation of filters using Monte Carlo simulation of 4 MV x-rays

Computed radiography (CR) is gradually replacing film. The application of CR for two-dimensional profiles and off-axis ratio (OAR) measurement using an imaging plate (IP) in a CR system is currently under discussion. However, a well known problem for IPs in dosimetry is that they use high atomic number (Z) materials, such as Ba, which have an energy dependency in a photon interaction. Although there are some reports that it is possible to compensate for the energy dependency with metal filters, the appropriate thicknesses of these filters and where they should be located have not been investigated. The purpose of this study is to find the most suitable filter for use with an IP as a dosimetric tool. Monte Carlo simulation (Geant4 8.1) was used to determine the filter to minimize the measurement error in OAR measurements of 4 MV x-rays. In this simulation, the material and thickness of the filter and distance between the IP and the filter were varied to determine most suitable filter conditions that gave the best fit to the MC calculated OAR in water. With regard to changing the filter material, we found that using higher Z and higher density material increased the effectiveness of the filter. Also, increasing the distance between the filter and the IP reduced the effectiveness, whereas increasing the thickness of the filter increased the effectiveness. The result of this study showed that the most appropriate filter conditions consistent with the calculated OAR in water were the ones with the IP sandwiched between two 2 mm thick lead filters at a distance of 5 mm from the IP or the IP sandwiched directly between two 1 mm lead filters. Using these filters, we measured the OAR at 10 cm depth with 100 cm source-to-surface distance and surface 10x10 cm{sup 2} field size. The results of this measurement represented that it is possible to achieve measurements with less than within 2.0% and 2.0% in the field and with less than 1.1% and 0.6% out of the field by using 2 and 1 mm lead filters, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of Resistive Plate Chambers in the Upgrade of the PHENIX Forward Spectrometers

Resistive Plate Chambers (RPCs) are being used for a number of applications outside of the fields of nuclear and particle physics. These include large arrays for neutrino detection and various imaging applications. A brief summary of RPC applications will be given, but the talk will focus on the specific application of a muon trigger upgrade for the PHENIX experiment at the Relativistic Heavy Ion Collider (RHIC). A large portion of the RHIC scientific program is devoted to a study of the origin of the proton spin. A part of this program is to determine the contribution to the proton spin of the up and down quarks and anti quarks. The PHENIX experiment will study these contributions using the forward muon spectrometers to observe muons from the decay of W bosons produced in the collision of 100 and 250 GeV polarized protons. Due to the high muon backgrounds the forward spectrometer triggers will be upgraded using a series of RPCs with bakelite gaps to track charged particles and provide prompt signals for the trigger. The layout for the upgraded spectrometers will be given along with a discussion of the background rejection expected. A series of RPC prototypes have been built and testing procedures will be discussed. Test results on timing, efficiency and spatial resolution will be shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Creation of storage centers in CsBr:Eu{sup 2+} needle image plates by vacuum ultraviolet radiation

In this study, the photostimulated luminescence of the CsBr:Eu{sup 2+} needle image plates (NIPS) after vacuum ultraviolet (VUV) irradiation and their photoluminescence under VUV and UV excitation were investigated. It was shown that the photostimulable storage centers arise almost exclusively due to irradiation of the CsBr:Eu NIPs in the spectral lines of creation of the 4p{sup 5}5s anion excitons, and not in the region of interband transitions of CsBr. The explanation of the results is based mainly on the radiative and nonradiative decay of the self-localized e+Br{sub 2}{sup -} excitons.

74 ATOMIC AND MOLECULAR PHYSICS↗

Determining time resolution of microchannel plate detectors for electron time-of-flight spectrometers

The temporal resolution of a 40 mm diameter chevron microchannel plate (MCP) detector followed by a constant fraction discriminator and a time-to-digital converter was determined by using the third order harmonic of 25 fs Ti:sapphire laser pulses. The resolution was found to deteriorate from 200 to 300 ps as the total voltage applied on the two MCPs increased from 1600 to 2000 V. This was likely due to a partial saturation of the MCP and/or the constant fraction discriminator working with signals beyond its optimum range of pulse width and shape.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of two-channel prototype ITER vacuum ultraviolet spectrometer with back-illuminated charge-coupled device and microchannel plate detectors

A vacuum ultraviolet (VUV) spectrometer of a five-channel spectral system is designed for ITER main plasma impurity measurement. To develop and verify the system design, a two-channel prototype system is fabricated with No. 3 (14.4-31.8 nm) and No. 4 (29.0-60.0 nm) among the five channels. The optical system consists of a collimating mirror to collect the light from source to slit, two holographic diffraction gratings with toroidal geometry, and two different electronic detectors. For the test of the prototype system, a hollow cathode lamp is used as a light source. To find the appropriate detector for ITER VUV system, two kinds of detectors of the back-illuminated charge-coupled device and the microchannel plate electron multiplier are tested, and their performance has been investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radio frequency breakdown between structured parallel plate electrodes with a millimetric gap in low pressure gases

This paper presents an investigation into radio frequency (rf) breakdown for electrodes with holes or protrusions, approximating the situation in real reactors and providing a benchmark for fluid simulations. rf breakdown curves (voltage versus pressure) generally show a steep left-hand branch at low pressures and a flatter right-hand branch at higher pressures. Introducing protrusions or holes in parallel plate electrodes will lower the breakdown voltage in certain conditions. Yet experiments show that the breakdown curves are not perceptibly influenced by the increased electric field at sharp edges or ridges. Instead, both experiments and simulation show that breakdown at high pressure will occur at the protrusion providing the smallest gap, while breakdown at low pressure will occur in the aperture providing the largest gap. This holds true as long as the feature in question is wide enough. Features that are too narrow will lose too many electrons due to diffusion, either to the walls of the apertures or to the surroundings of the protrusion, which negates the effect on the breakdown voltage. The simulation developed presents a tool to aid the design of complex rf parts for dark-space shielding.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermoviscoelastic finite element modeling of laser-generated ultrasound in viscoelastic plates

Laser-generated ultrasound in a thin composite plate with thermoviscoelastic property has been studied quantitatively. According to thermoviscoelastic theory, considering the viscoelastic and thermophysical properties of materials, a numerical model for the laser-generated Lamb waves is established in the frequency domain by using a finite element method. It is confirmed that the temperature and displacement fields calculated in the frequency domain coincide well with those obtained in the time domain. In the numerical simulations of thermoviscoelastically generated Lamb waves, the effects of viscoelastic and elastic stiffness moduli, and the thickness of the materials have been taken into account in details. The characteristics of the Lamb waves in the numerical results agree well with the features of the disperse curves. The results show that the finite element method in this paper provides a useful technique to characterize mechanical properties of composite materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Monte Carlo Simulations of Microchannel Plate Detectors II: Pulsed Voltage Results

This paper is part of a continuing study of straight-channel microchannel plate (MCP)–based x-ray detectors. Such detectors are a useful diagnostic tool for two-dimensional, time-resolved imaging and time-resolved x-ray spectroscopy. To interpret the data from such detectors, it is critical to develop a better understanding of the behavior of MCPs biased with subnanosecond voltage pulses. The subject of this paper is a Monte Carlo computer code that simulates the electron cascade in a MCP channel under an arbitrary pulsed voltage, particularly those pulses with widths comparable to the transit time of the electron cascade in the MCP under DC voltage bias. We use this code to study the gain as a function of time (also called the gate profile or optical gate) for various voltage pulse shapes, including pulses measured along the MCP. In addition, experimental data of MCP behavior in pulsed mode are obtained with a short-pulse UV laser. Comparisons between the simulations and experimental data show excellent agreement for both the gate profile and the peak relative sensitivity along the MCP strips. We report that the dependence of relative gain on peak voltage increases in sensitivity in pulsed mode when the width of the high-voltage waveform is smaller than the transit time of cascading electrons in the MCP.

Kruschwitz, Craig A.↗

Note: Non-gain microchannel plate gated framing camera

An x-ray framing camera using a non-gain microchannel plate (MCP) is reported in this article. The advantage of the non-gain MCP is the less transit time spread. The non-gain MCP gated framing camera has four microstrip line cathodes with 6 mm in width. The time domain reflectometry curves of the four microstrip lines are measured, which show that the characteristic impedance of each microstrip line is about 17 {Omega}. While the photocathode is driven by the gating electrical pulse with width of 125 ps and amplitude of -1.48 kV with -400 V bias, the measured exposure time of this camera is about 72 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of a Thomson parabola ion spectrometer and Fujifilm imaging plate detectors for protons, deuterons, and alpha particles

A Thomson parabola ion spectrometer has been designed for use at the Multiterawatt (MTW) laser facility at the Laboratory for Laser Energetics (LLE) at University of Rochester. This device uses parallel electric and magnetic fields to deflect particles of a given mass-to-charge ratio onto parabolic curves on the detector plane. Once calibrated, the position of the ions on the detector plane can be used to determine the particle energy. The position dispersion of both the electric and magnetic fields of the Thomson parabola was measured using monoenergetic proton and alpha particle beams from the SUNY Geneseo 1.7 MV tandem Pelletron accelerator. The sensitivity of Fujifilm BAS-TR imaging plates, used as a detector in the Thomson parabola, was also measured as a function of the incident particle energy over the range from 0.6 MeV to 3.4 MeV for protons and deuterons and from 0.9 MeV to 5.4 MeV for alpha particles. The device was used to measure the energy spectrum of laser-produced protons at MTW.

43 PARTICLE ACCELERATORS↗

One hundred anode microchannel plate ion detector

A one-hundred-anode microchannel plate detector is constructed on a 10 cm x 15 cm printed circuit board and attached to a homebuilt matrix assisted laser desorption ionization (MALDI) time-of-flight mass spectrometer. Ringing and cross talk between anodes have been successfully eliminated and preliminary mass spectra of peptide ions recorded. With one hundred anodes on the printed circuit board, spatial information about the ion beam can also be readily determined with this detector. During operation, the detector anode assembly loses sensitivity after ions strike it for a considerable period of time due to charging of the non-conductive regions between anodes. However, this effect can be minimized by deflecting matrix ions away from the detector.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗