Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARTICLE IDENTIFICATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Blinded by the Light: Commissioning of the Hall C SHMS Heavy Gas Cherenkov Detector

The University of Regina built a heavy gas Cherenkov (HGC) detector for use at the Thomas Jefferson National Accelerator Facility (JLab) as it enters a new era of 12 GeV experiments. This detector will play an important role in pi/K separation between 3 - 11 GeV/c in experimental Hall C and is housed in the Super High Momentum Spectrometer (SHMS). Recently, the first experimental data have become available, allowing the performance of the HGC to be evaluated. The calibration procedure developed is presented, as well as the characterization of the Poisson nature of the photomultiplier tube photoelectron response. Calculation of the HGC efficiency is also performed and used as an independent confirmation of the index of refraction of the Cherenkov media. This thesis also outlines JLab’s experimental Hall C, the data acquisition, the HGC simulation, and the particle identification capabilities of the HGC in an experimental setting.

Ambrose, George Ryan↗

Detector calibration using through going and stopping muons in the MicroBooNE LArTPC

The MicroBooNE experiment at Fermilab uses a liquid argon time projection chamber (LArTPC) in the Booster Neutrino Beam to search for anomalous production of electron-neutrino-like events and to study neutrino-argon cross sections in the 1 GeV neutrino energy regime. The detector operates at 0.273 kV/cm drift electric field and its TPC has an active mass of 85 tons of liquid argon. One of the main advantages of the LArTPC technology is its ability to reconstruct both particle track direction and energy with very high precision. Effects such as misconfigured or cross-connected TPC wires, space charge effects, electron attenuation, diffusion, and recombination can worsen the energy resolution of the detector. Therefore the detector calibration is of utmost importance to get the correct dE/dx (energy loss per unit track length) measurement. This is crucial for particle identification and in particular the separation of electrons and photons, essential for oscillation analyses. Here we describe a method developed for MicroBooNE to calibrate the detector by correcting for the above mentioned effects. In this analysis first we make the detector response uniform throughout the detector and time using through-going muons. Next stopping muons are used to determine the energy scale and convert dQ/dx to dE/dx.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Selection of ν μ charged–current induced interactions with $N \gt 0$ protons and performance of events with $N=2$ protons in the final state in the MicroBooNE detector from the BNB

Using the MicroBooNE liquid argon time projection chamber (LArTPC) at Fermilab’s Booster Neutrino Beam, we examine samples of charged current events from neutrino scattering on argon with exactly two or with any number of protons in final states with no other hadrons except neutrons. We described the particle identification method employed for protons, and we compare measured kinematic distributions of muons and protons to predictions from several Monte Carlo event generators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PMT Gain Calibration In MicroBooNE

Liquid argon (LAr) is an ideal scintillating detector medium: it is very bright, releasing O(10, 000) photons per MeV of deposited energy, and is also transparent to its own scintillation. Light data in liquid argon time projection chamber (LArTPC) experiments in general and MicroBooNE in particular has many important uses. In MicroBooNE, light collected over all photosensors is used as a first and second level trigger. At the data acquisition stage ~ 5PE is required for triggering. An additional software trigger of ≈ 20PE helps reject a large portion of cosmic ray background in events with no neutrino interaction occurring during the beam spill. Scintillation can also be used for the determination of absolute drift coordinate of non-beam related events. Additionally, matching reconstructed light to reconstructed TPC charge is a powerful tool for cosmic ray rejection. Finally due to the specific properties of LAr scintillation, light information can be used for particle identification. For many of these tasks good modeling of the light response of the detector is crucial. Applying data-driven corrections to optical detector data and simulation (prediction) allows to obtain a well calibrated energy scale from the PMTs. This reduces discrepancies between data and simulation, and calibrates out non-uniformities of data over the full data taking period. Thus it is expected to factor in improving systematic uncertainties on MicroBooNE’s flagship analyses - the low energy excess (LEE) search and LAr-ν cross-section measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mixed Material Scintillator Systems for Neutron Detection

Scintillators are a fundamental technology that enables radiation detection. Their use has historically enabled the detection of incoming gamma radiation, with recent advances in plastic scintillator development enabling detection and discrimination of neutron and gamma radiation through pulse shape discrimination. However, scintillators have so far consisted of a single material, typically one primary dye and one secondary dye embedded in a plastic matrix. Based on the simulation studies described previously, mixed material scintillator systems with multiple secondary dyes arranged in alternating, periodic micro-sized regions opens the door for scintillators with a wide variety of different capability, such as directional sensing, positional reconstruction, particle identification, and pulse shape discrimination. However, fabrication of a mixed material scintillator system by conventional manufacturing methods is difficult to manufacture and scale, creating a barrier to their wide spread implementation. On the other hand, additive manufacturing additive manufacturing presents itself as the optimal method for fabricating mixed material scintillator systems based on its flexibility, ability to fabricate fine features, and potential for multimaterial fabrication.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of U Isotope Ratios by Laser Ablation MC-ICP-MS for IAEA Safeguards

This project will develop methodology to identify and analyze U and Pu containing particles using laser ablation MC-ICP-MS. The proposed work will involve: i) setup and optimization of the LA-MC-ICP-MS system, ii) testing and validation by analysis of QC standards, iii) designing analytical protocols for single particles, and iv) developing a data processing system. Ultimately, this project will output a detailed operating procedure documenting the experimental techniques and data processing routines required to perform particle identification and analysis by laser ablation MC-ICP-MS, that can be shared with IAEANWAL laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

R&D Towards CUPID, a Ton-Scale Bolometric 0νββ Experiment

CUPID, the CUORE Upgrade with Particle IDentification, is a next-generation experiment to search for neutrinoless double beta (0νββ) decay and other rare events using scintillating bolometers with 100 Mo. This award supported simulation and design work on the muon tagger system for CUPID as well the development of a plan and protocol for the irradiation and fabrication of the NTD thermal sensors for CUPID.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Analytical Method for Measuring U and Pu Particles by Laser Ablation MC-ICP-MS for the NWAL

This project will develop methodology to identify and analyze U and Pu containing particles using laser ablation MC-ICP-MS. The proposed work will involve: i) setup and optimization of the LA-MC-ICP-MS system, ii) testing and validation by analysis of QC standards, iii) designing analytical protocols for single particles, and iv) developing a data processing system. Ultimately, this project will output a detailed operating procedure documenting the experimental techniques and data processing routines required to perform particle identification and analysis by laser ablation MC-ICP-MS.

07 ISOTOPE AND RADIATION SOURCES↗

ECAL Calibration and Energy Resolution for a 10TeV Detector Geometry

In the pursuit of a muon collider operating at ~10 TeV center-of-mass-energy, designing a highly accurate and sensitive detector is crucial. Calorimetry plays a key part in any detector setup, as we rely on our calorimeters for energy reconstruction and particle identification. Therefore, an effective calorimeter must be extremely well-calibrated and achieve excellent resolution. This poster will report on efforts to achieve a comprehensive energy calibration of the electromagnetic calorimeter (ECAL) for our 10 TeV detector design. This calibration is necessary in order to achieve desired energy resolution for reconstructed photons across a wide range of energies (0-1TeV). We report on the challenges introduced by the new location of the solenoid in our latest 10 TeV detector design, the necessity of a calibration strategy that is both energy-dependent and angularly dependent, and the resulting effects on photon energy resolution.

Powers, Rose↗

Neutron Tagging From Neutrino Interactions in DUNE-ND 2x2 Prototype

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims to measure whether CP is violated in the leptonic sector (if violated, how much) and unambiguously determine the neutrino mass ordering. DUNE consists of near and far detectors that rely on liquid argon time projection chamber (LArTPC) technology to observe neutrino interactions. The near detector (ND) will be placed in Fermilab, near the neutrino source, while the far detector (FD) will be deployed in Sanford Lab, 1.5 km deep underground, which is 1300 km away from the source. LArTPCs provide excellent particle identification and calorimetry; however, detecting neutrons is challenging, as they do not leave direct ionization signals in LArTPCs. Neutrons can carry away up to 25% of the neutrino energy, introducing a significant uncertainty in DUNE measurements. The DUNE near detector (ND) features a novel modular LArTPC with pixelated charge readout, which enhances event recons truction. The modular design enables precise correlation between ionization signals and light signals in a high-rate environment, improving the identification of delayed energy depositions from neutrons in neutrino interactions. We introduce a neutron tagging technique using the 2x2 Demonstrator, a small-scale prototype of the DUNE ND LArTPC. The analysis utilizes Monte Carlo simulations and deep-learning techniques to identify neutron-induced energy depositions and reconstruct low-energy activity.

Kufatty, Georgette [Florida State U.]↗

Charged Current Coherent Pion Production Cross-Section Measurement at MicroBooNE

Coherent pion production, characterized by a neutrino interacting with an entire nucleus without breaking it apart, results in a forward-going muon, pion, and a low-momentum recoil nucleus. By leveraging an improved understanding of particle identification and background parameterization, we aim to achieve a new level of sensitivity to coherent interactions at low neutrino energy. The outcome of this analysis will contribute to ongoing efforts to model neutrino nucleus interactions accurately in neutrino oscillation studies and beyond Standard Model searches in MicroBooNE and future experiments, such as DUNE. We present progress towards a measurement of charged current coherent pion production cross-section on argon with the MicroBooNE liquid argon time projection chamber detector. This measurement will use MicroBooNE's full dataset collected from the Booster Neutrino Beam with a total exposure of \( 1.3 \times 10^{21} \) protons-on-target and average neutrino energy of 0.8 GeV.

Hussain, Adil [Kansas State U.]↗

ACHILLES-GENIE Interface for Neutrino Simulations, ADRIANO2 Tile Prototype for High-Granularity Dual-Readout Calorimetry

ICARUS (Imaging Cosmic And Rare Underground Signals) is a liquid argon time projection chamber (LArTPC) detector that pursues the sterile neutrino, which relies on accurate simulations of neutrino-argon interactions. REDTOP (Rare Eta Decays To Observe new Physics) is a proposed low-energy, high-intensity meson factory designed to explore rare $\eta$/$\eta'$ meson decays and probe physics beyond the Standard Model. As a next-generation experiment, this requires both accurate simulations and innovative detector technologies. This project contributes to both ICARUS, from a simulation perspective, and REDTOP, from both a simulation and detection perspective, through the event generation of lepton-nucleon interactions and the physical enhancement of the calorimeter technology within the REDTOP detector. We developed an interface between ACHILLES (A CHIcago Land Lepton Event Simulator), a theory-driven lepton-level event generator, and GENIE, a robust event generator framework used for neutrino physics. By incorporating the precise theoretical cross-section calculations of ACHILLES into the experimental realism of GENIE, the interface allows for improved accuracy of neutrino-nucleon simulations, which can be adapted for the proton beam specifications of the REDTOP meson factory as well as for the ICARUS experiment. In parallel, we developed an improved prototype for the ADRIANO2 (A Dual Readout Integrally Active Non-segmented Option) dual-readout calorimeter tiles for the REDTOP detector. To improve the efficiency of the lead-glass tiles trapping Cherenkov light for energy reconstruction and particle identification, we optimized the application of a highly reflective coating. Through viscosity and thickness control, masking, and a custom spray technique, we refined the coating process to reduce surface defects and improve light yield. Together, these efforts strengthen the ICARUS neutrino program and REDTOP's capability of detecting rare decay events.

Visser, Erin [Michigan State U.]↗

Status and Performance of the GlueX DIRC

The GlueX experiment is located in experimental Hall D at Jefferson Lab (JLab) and provides a unique capability to search for hybrid mesons in high-energy photoproduction, utilizing a $\sim$9 GeV linearly polarized photon beam. Since 2020 a Detector of Internally Reflected Cherenkov light (DIRC) has been in use at GlueX, utilizing components from the decommissioned BaBar DIRC. In this contribution we will discuss the status and performance of the GlueX DIRC with the data collected to date, including recent developments in the use of machine learning for particle identification.

Stevens, Justin [College of William and Mary, Will↗

Signal Processing in SBND with Calibrated and Validated Electronics and Field Responses

SBND is a liquid argon time projection chamber in Fermilab’s Short-Baseline Neutrino Program, located 110 m from the neutrino source and operating in a high-rate environment with unprecedented statistics. Charged particles from neutrino interactions ionize the argon, and the resulting electrons drift to the anode wires, inducing current signals recorded as raw waveforms. These waveforms are a convolution of deposited charge with the electronics and TPC field responses, making accurate signal processing essential for recovering the true charge distribution. Signal processing forms the starting point for SBND reconstruction, directly impacting hit finding, charge calibration, clustering, and the reconstruction of tracks and showers, and therefore playing a key role in energy reconstruction and particle identification. In this poster, we present an overview of the SBND signal processing chain, including noise removal, channel-by-channel electronics correction, signal identification, and deconvolution using measured electronics and TPC field responses. We demonstrate that the two kernel functions—electronics and field responses—achieve high precision when compared to data, ensuring that the SBND signal processing chain provides a robust and accurate foundation for event reconstruction and precision physics measurements.

Singh, Prabhjot [Louisiana State U.] (ORCID:000000↗

First Measurement of Sub-GeV nu_mu Charged-Current Coherent Pion Production on Argon in MicroBooNE

Coherent pion production, characterized by a neutrino interacting with an entire nucleus without breaking it apart, results in a forward-going muon, pion, and a low-momentum recoil nucleus. This process provides a sensitive probe of neutrino-nucleus interactions and offers a potential standard candle for neutrino-flux normalization in neutrino-oscillation experiments. We present the first measurement of the flux-averaged charged-current coherent pion production cross section on argon nucleus using the MicroBooNE liquid argon time projection chamber. The analysis employs particle identification together with a data-driven background parameterization to isolate the coherent signal. This measurement uses the full MicroBooNE dataset collected from the Fermilab Booster Neutrino Beam, corresponding to an exposure of 1.26E10^21 protons on target and an average neutrino energy of approximately 0.8 GeV. The result provides the first constraint on charged-current coherent pion production on argon nucleus at sub-GeV energies and supplies important input for improving neutrino interaction modeling in current and future experiments such as DUNE.

Hussain, Adil [Kansas State U.] (ORCID:00000001621↗

First Measurement of Charged Current Muon Neutrino-Induced Kaon Production on Argon using the MicroBooNE Detector

MicroBooNE is an 85-tonne active mass liquid argon time projection chamber (LArTPC) neutrino detector exposed to the Booster Neutrino Beamline (BNB) at Fermilab. One of the key physics goals is the precise measurement of neutrino interactions on argon in the 1 GeV energy regime. The study of strange and heavier meson production in neutrino interactions, in particular final states containing $K^{+}$, will help to improve the background estimates for future nucleon decay searches in experiments such as DUNE, provide valuable input for improving neutrino generator models, and will allow the development of techniques to enhance the particle identification capabilities of LArTPCs. In this work, we present the first-ever cross-section measurements of charged current muon neutrino-induced kaon production on argon at MicroBooNE.

Rodriguez Rondon, Jairo H. [South Dakota Sch. Mine↗

Advancing Detector R&D for High-Pressure Gaseous Argon TPCs in Precision Neutrino Physics

High-pressure gaseous argon time projection chambers (HPgTPCs) represent an emerging detector paradigm for neutrino physics, combining increased target density with the intrinsic tracking and low thresholds of gaseous detectors. This approach enables detailed reconstruction of exclusive final states, improved particle identification, and sensitivity to low-energy and rare processes — capabilities that are increasingly central to precision oscillation measurements and searches for beyond-the-Standard-Model signatures. This abstract presents an overview of ongoing detector R&D toward high-pressure gaseous argon TPC operation, with emphasis on micro-pattern gas detector (MPGD) charge amplification in argon-based mixtures. We report experimental characterization of triple-GEM structures at pressures relevant for neutrino applications, including studies of multiplication factor scaling, stability, and operational voltage envelopes across gas admixtures. Measurements performed at the TOAD and GORG test stands at Fermilab help define viable amplification and electronics noise regimes in conditions where higher density imposes stricter constraints on signal formation. These results provide essential input to the optimization of high-pressure gaseous argon detectors for future neutrino experiments, including near-detector concepts such as ND-GAr in DUNE Phase II near detector upgrade. More broadly, this program shows how dedicated detector R&D can expand the precision frontier in neutrino physics by enabling complementary reconstruction capabilities beyond conventional detectors.

McConnell, Brenna [Indiana U.] (ORCID:000900041138↗

Pandora-based muon neutrino disappearance search in the SBN program with 1muonNp quasi-elastic like channel

The Short-Baseline Neutrino (SBN) program at Fermilab aims to perform a definitive search for light sterile neutrinos using multiple liquid argon time projection chamber detectors. We present the status of an analysis of muon neutrino charged-current interactions in two SBN detectors (SBND and ICARUS), selecting fully contained events with one muon and at least one proton in the final state, inspired by the recent ICARUS standalone results. This topology-driven selection reduces dependence on neutrino interaction cross-section modeling while preserving high statistics and good neutrino energy resolution, enabled by robust reconstruction and particle identification. Fully contained events enable precise kinematic reconstruction and support relative measurements between detectors, directly addressing the core goals of the SBN program. A detailed evaluation of systematic uncertainties is currently underway, with the objective of reducing the dominant systematics to the percent level. The current status of this analysis, with a particular focus on the event selection performance, will be presented in this poster.

Artero Pons, Maria [Padua U.; INFN, Padua]↗