Surrogate-based calibration for the quasi-biennial oscillation
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This is the presentation slide deck for UFFC-JS 2024 conference.
Explore the source record for details and available documents.
Useful method for high-precision measurements of integral cross section in various samples. The availability of benchmark-quality effective delayed neutron fraction (ßeff) values for nuclear data and code validation remains limited.
Not provided.
Cyber-physical system security presents unique challenges to conventional measurement science and technology. Anomaly detection in software-assisted physical systems, such as those employed in additive manufacturing or in DNA synthesis, is often hampered by the limited available parameter space of the underlying mechanism that is transducing the anomaly. As a result, the formulation of anomaly detection for such systems often leads to inverse or ill-posed problems, requiring statistical treatments. Here, we present Bayesian inference of unknown parameters associated with a generic actuator considered as a representative vital element of a cyber-physical system. Via a series of experimental input-output measurements, a transfer function for the actuator is obtained numerically, which serves as our model for the proposed method. Linear, nonlinear, and delayed dynamics may be assumed for the actuator response. By devising a code-based malicious signal, we study the efficacy of Bayesian inference for its potential to produce a detection, including uncertainty quantification, with a remarkably small number of input data points. Our approach should be adaptable to a variety of real-time cyber-physical anomaly detection scenarios.
This is a talk given at Computers in High Energy Physics in Adelaide, South Australia, Australia in November 2019. It is partially intended to explain the context of DUNE Computing for computing specialists. The DUNE collaboration consists of over 180 institutions from 33 countries. The experiment is in preparation now with commissioning of the first 10kT fiducial volume Liquid Argon TPC expected over the period 2025-2028 and a long data taking run with 4 modules expected from 2029 and beyond. An active prototyping program is already in place with a short test beam run with a 700T, 15,360 channel prototype of single-phase readout at the neutrino platform at CERN in late 2018 and tests of a similar sized dual-phase detector scheduled for mid-2019. The 2018 test beam run was a valuable live test of our computing model. The detector produced raw data at rates of up to ~2GB/s. These data were stored at full rate on tape at CERN and Fermilab and replicated at sites in the UK and Czech Republic. In total 1.2 PB of raw data from beam and cosmic triggers were produced and reconstructed during the six week test beam run. Baseline predictions for the full DUNE detector data, starting in the late 2020's are 30-60 PB of raw data per year. In contrast to traditional HEP computational problems, DUNE's Liquid Argon TPC data consist of simple but very large (many GB) 2D data objects which share many characteristics with astrophysical images. This presents opportunities to use advances in machine learning and pattern recognition as a frontier user of High Performance Computing facilities capable of massively parallel processing.
NOvA is a long baseline neutrino experiment which uses muon neutrinos produced by the NuMI beam at the Fermi National Accelerator Laboratory to measure muon neutrino disappearance and electron neutrino appearance, among other analyses. The Far/Near Extrapolation analysis framework (FNEX) was used to measure muon neutrino disappearance using the events observed by NOvA while the NuMI beam was in Forward Horn Current configuration (i.e. this analysis uses neutrino data, not antineutrino data). The values of the parameters measured in this analysis are sin 2 θ 23 - 0.499$^{+0.098}_{-0.069}$ and Δm$^2_{32}$ - 2.454$^{+0.108}_{0.119}$ × 10 -3 eV, which is consistent with the results of NOvA’s main muon neutrino disappearance analysis using the experiment’s usual framework, known as CAF. The CHIPS detector is a water Cherenkov detector currently in construction. It will also use the NuMI beam to perform muon neutrino disappearance and electron neutrino appearance analyses. The necessary water clarity for a detector with a diameter of 25 m and a height of 6 m is discussed, as well as the results of testing water filtration systems. The filtration that will be used for the detector is a 10 µm carbon block filter and a 0.5 µm filter in series, with no reverse osmosis or ultraviolet sterilisation being used. This provides an attenuation length of 16.63 ± 0.25 m for light of 532 nm wavelength (green), so light with a wavelength of 405 nm (violet) would have an attenuation length of 133±2 m. The greatest possible distance between a PMT and any point in the detector’s volume is approximately 26 m, so 133 m is sufficient for the detector to measure Cherenkov light produced anywhere in the detector.
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
Abstract not provided.
Reliable power system operation requires that system operators maintain a satisfactory small-signal stability margin at all times. Mode meters allow system operators to continuously monitor the stability margin by analyzing synchrophasor measurements. Experience with mode meters at the Bonneville Power Administration (BPA) has revealed that mode meters sometimes suffer severe bias following transient disturbances. In this paper, a robust version of the Yule-Walker mode meter algorithm is proposed to mitigate this bias. The robust capability is introduced by modifying the estimator of the autocovariance sequence (ACS) on which the algorithm depends. Tests with field-measured data demonstrate that the robust Yule-Walker (RYW) algorithm significantly outperforms its conventional counterpart and is better able to provide system operators with accurate information about the system's stability margin.
Abstract not provided.
Abstract not provided.
Abstract not provided.