Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Active multi-mode data analysis to improve fault diagnosis in AHUs

Faults in heating, ventilation and air conditioning systems can lead to increased energy consumption, occupant comfort issues, and reduced equipment lifetime. Commercial fault detection and diagnosis (FDD) tools has been increasingly deployed in U.S. commercial buildings. While they are helping to achieve energy efficiency and operational reliability, there remain gaps in their fault diagnostic capabilities. The diagnostic results often contain multiple distinct candidate root causes (CRCs) or offer no insight into CRCs. This study developed a novel active rule-based multi-mode data analysis method to enhance diagnostic resolution by applying proven rule sets and additional new rules to data from multiple known operational modes. The proposed method was demonstrated using enhanced air handling unit performance assessment rule sets and validated with the simulated data of two air handling units. New metrics, namely, reduced number of CRCs and improvement ratio, were developed to quantify the improvement of fault diagnostic resolution. The validation results showed that the proposed method effectively reduced the number of CRCs in contrast to analyzing data solely for a single mode of operation. It achieved a median improvement ratio of 80% in 19 test cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ice storage model-predictive control in an office building with PV: scenario, error and sensitivity analysis

Thermal energy storage (TES) can enable more building-sited renewable electricity generation and lower utility bill costs for buildings owners and occupants, especially when there are high demand and variable time-of-use (TOU) charges. A model predictive control (MPC) strategy can offer additional savings over a schedule-based control with added complexity and reliance on forecasts. Here, this study examines savings for medium office buildings with chiller plants in three locations with building-installed solar photovoltaics (PV) to understand the impact of MPC. Control setpoints are fixed by a schedule-based control or optimized by nonlinear MPC. These control setpoints are actuated within EnergyPlus building models to simulate the utility cost of the chiller plant. NLP solutions can be unstable or unrealistic, but our results show that by regularizing the NLP, the solutions can be reasonably followed by the building model. MPC models make simplifications that lead to errors once the controller is participating in and changing the operation of the building. These errors average 9 % across the cases, showing that the most important parts of the system are represented. The no-thermal load costs are computed to show that the optimization can in some cases achieve both the minimum TOU and minimum monthly demand costs by demand management while reducing TOU energy costs by energy arbitrage. The MPC saves 35–66 % in the annual chiller plant operating costs, which is an additional savings above the schedule by 1–33 %. PV and TES are complementary and mostly independent, but a load with PV often results in better performance for the schedule. Our case study and sensitivity analysis show the importance of modeling and optimization for complex rates, but also the circumstances wherein a simpler strategy achieves the same performance with less potential for error.

14 SOLAR ENERGY↗

Good practices for documenting AI-based studies on energy and buildings

Artificial intelligence has transformed building science research over the past decade, with applications spanning energy modeling, energy prediction, HVAC optimization and controls, fault detection, and occupancy modeling. However, many studies lack adequate documentation of datasets, algorithms, training procedures, and validation methods. Building science research faces additional challenges including inconsistent evaluation metrics, limited generalizability across building types, climates, and significant gaps between experimental studies and deployed systems. This communication provides practical guidance for good practices in documenting and publishing AI-based research following established standards from the computer science and machine learning communities. By adopting frameworks such as Datasheets for Datasets, Model Cards, and standardized reproducibility checklists, researchers can ensure their work meets the rigorous documentation standards necessary for reproducible, comparable, and impactful building science research.

Hong, Tianzhen [Lawrence Berkeley National Laborat↗

Experimental test of model predictive control in a variable air volume system

Model predictive control (MPC) has been widely studied as a promising approach for improving energy efficiency and operational flexibility in buildings, yet its real-world performance for commercial variable air volume (VAV) systems remains insufficiently characterized. In particular, the impacts of model mismatch on control robustness, real-time computational burden, and device-level operation are rarely evaluated using long-term field data. Here, this study presents a comprehensive experimental evaluation of MPC applied to a full-scale VAV system in Oak Ridge National Laboratory’s Flexible Research Platform-2 building with constant cooling/heating temperature setpoints and no occupancy. The study offers three key advantages over existing work: (1) it uses a representative building in a full-scale experimental test, capturing realistic system dynamics and complexity; (2) it evaluates a relatively sophisticated MPC formulation using two different optimization solvers (Gurobi and PSO), fully accounting for computational complexity and methodological diversity; and (3) it systematically assesses potential negative impacts on various building devices, benchmark against a well-established baseline, ASHRAE Guideline 36 (G36). To isolate zone- and air-handling-unit–level supervisory control effects, the supply fan was operated with a fixed static pressure setpoint under all strategies, and the trim-and-response static pressure reset in G36 was not enabled. Results show that MPC maintained thermal comfort while improving energy efficiency. Abrupt solar radiation variations degraded performance. Computation times ranged from ∼1 s (Gurobi) to ∼ 70 s (PSO). Compared with G36, MPC achieves 33% energy savings and reduces median reheat coil output by approximately a factor of 5–10 for a representative cooling day under matched weather conditions. However, it increases the maximum discomfort deviation from 0.5 to 1°C and results in a 32% increase in staging frequency. In addition, PSO-based MPC introduced damper oscillations, also affecting actuator longevity.

ASHRAE guideline 36↗

Machine learning-enhanced hybrid modeling approach for better identification of a building thermal network model and improved prediction

The gray-box modeling approach, which uses a semi-physical thermal network model, has been widely used in building prediction applications, such as model predictive control (MPC). However, unmeasured disturbances, such as occupants, lighting, and in/exfiltration loads, make it challenging to apply this approach to practical buildings. In this word, we propose a hybrid modeling approach that integrates the gray-box model with a model for unmeasured disturbance. After reviewing several system identification approaches, we systematically designed the unmeasured disturbance model with a model selection process based on statistical tests to make it robust. We generated data based on the building model calibrated by real operational data and then trained the hybrid model for two different weather conditions. The hybrid model approach demonstrates an RMSE reduction of approximately 0.2–0.9 °C and 0.3–2 °C on 1-day ahead temperature prediction compared to the Conventional approach for mild (Berkeley, CA) and cold (Chicago, IL) climates, respectively. In addition, this approach was applied to experimental data obtained from the laboratory building to be used for the MPC application, showing superior prediction performances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

From models to reality: a systematic review on simulated and measured residential heat pump energy savings

High-performance HVAC solutions are central to residential energy management. A substantial share of these are electric, reversible-cycle systems, with heat pumps representing the largest portion of current and near-term adoption. This review synthesizes peer-reviewed and grey literature on residential space heating and cooling heat pumps. The academic literature is dominated by modeling (73.8%), with limited field measurement (13.1%). Grey literature from United States serve as a supplemental resource providing measured savings. Conversions from electric-resistance heating consistently show the largest site energy reductions, while oil/propane baselines yield moderate savings, and gas baseline scenario often deliver small and region-dependent savings. This study cross-checks the grey literature measured data with simulation data filtered from the ResStock dataset. The comparison indicates a discrepancy between simulations and measured data: simulated site EUIs are typically lower than measured EUIs, but percentage energy savings fall in similar ranges, implying simulations capture directional effects while underestimating energy use. Factors associated with variability and model–measurement differences include system characterization and control representation (e.g., backup heat engagement, thermostat/setpoint strategies, commissioning/installation quality), occupant behavior, weather normalization, metering scope, and envelope characterization. This paper also outlines the proposed methodology for comparing simulation and measured data for heat pumps. It emphasizes the metrics used for comparison and units harmonization, building characteristics matching, and compact metadata are needed for simulations to match measured data. The proposed methodology is expected to improve the credibility of simulated savings as measured evidence grows.

Yu, Lili↗

Conditional distribution estimation of building characteristics with diffusion models for urban energy modeling

Understanding current energy consumption behavior in communities is critical for informing future energy use decisions and enabling efficient energy management. Urban energy models, which are used to simulate these energy use patterns, require large datasets with detailed building characteristics for accurate outcomes. However, such detailed characteristics at the individual building level are often unknown and costly to acquire, or unavailable. Through this work, we propose using a generative modeling approach to generate realistic building attributes to fill in the data gaps and finally provide complete characteristics as inputs to energy models. Our model learns complex, building-level patterns from training on a large-scale residential building stock model containing 2.2 million buildings. We employ a tabular diffusion-based framework that is designed to handle heterogeneous (discrete and continuous) features in tabular building data, such as occupancy, floor area, heating, cooling, and other equipment details. We develop a capability for conditional diffusion, enabling the imputation of missing building characteristics conditioned on known attributes. We conduct a comprehensive validation of our conditional diffusion model, firstly by comparing the generated conditional distributions against the underlying data distribution, and secondly, by performing a case study for a Baltimore residential region, showing the practical utility of our approach. Our work is one of the first to demonstrate the potential of generative modeling to accelerate building energy modeling workflows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The flexibility gap: Socioeconomic and geographical factors driving residential flexibility

Residential consumers are moving to the center of electricity systems and their flexibility is seen as a key resource to integrate renewable energy sources and support the grid. However, residential flexibility capacities are not homogeneous, as they depend on household appliances, comfort patterns, occupancy, and climate conditions. In this work, we calculate the technical flexibility capacities of 45 consumer types in mainland Spain, organised according to income and regional criteria. We show that flexibility gaps exist at both regional and socioeconomic (income) levels with flexibility differences of up to 10 times more capacity between the household groups from the lowest to the highest capacities. These geographical and socioeconomic gaps in flexibility can lead to distortions in national markets and have the potential to exclude citizens from the provision of flexibility services. Our results show in quantitative terms that a consumer-centered approach without considering correcting measures nor these gaps in drafting energy policies may lead to increasing inequality levels in the residential sector. Under an economic competitive paradigm, households with lower income levels or located in regions with lower flexibility potential may be excluded from the provision of flexibility to the detriment of households with larger potential, raising justice concerns in a flexibility-based energy transition.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Benzo[a]pyrene (BaP) metabolites predominant in human plasma following escalating oral micro-dosing with [ 14 C]-BaP

Benzo[a]pyrene (BaP) is formed by incomplete combustion of organic materials (petroleum, coal, tobacco, etc.). BaP is designated by the International Agency for Research on Cancer as a group 1 known human carcinogen; a classification supported by numerous studies in preclinical models and epidemiology studies of exposed populations. Risk assessment relies on toxicokinetic and cancer studies in rodents at doses 5–6 orders of magnitude greater than average human uptake. Using a dose–response design at environmentally relevant concentrations, this study follows uptake, metabolism, and elimination of [ 14 C]-BaP in human plasma by employing UPLC - accelerator mass spectrometry (UPLC-AMS). Volunteers were administered 25, 50, 100, and 250 ng (2.7–27 nCi) of [ 14 C]-BaP (with interceding minimum 3-week washout periods) with quantification of parent [ 14 C]-BaP and metabolites in plasma measured over 48 h. [ 14 C]-BaP median T max was 30 min with C max and area under the curve (AUC) approximating dose-dependency. Marked inter-individual variability in plasma pharmacokinetics following a 250 ng dose was seen with 7 volunteers as measured by the C max (8.99 ± 7.08 ng × mL -1 ) and AUC0-48hr (68.6 ± 64.0 fg × hr -1 × mL -1 ). Approximately 3–6% of the [ 14 C] recovered (AUC 0-48 hr ) was parent compound, demonstrating extensive metabolism following oral dosing. Metabolite profiles showed that, even at the earliest time-point (30 min), a substantial percentage of [ 14 C] in plasma was polar BaP metabolites. The best fit modeling approach identified non-compartmental apparent volume of distribution of BaP as significantly increasing as a function of dose (p = 0.004). Bay region tetrols and dihydrodiols predominated, suggesting not only was there extensive first pass metabolism but also potentially bioactivation. AMS enables the study of environmental carcinogens in humans with de minimus risk, allowing for important testing and validation of physiologically based pharmacokinetic models derived from animal data, risk assessment, and the interpretation of data from high-risk occupationally exposed populations.

59 BASIC BIOLOGICAL SCIENCES↗

Learning-Based Demand Response in Grid Interactive Buildings via Gaussian Processes

This paper presents a predictive controller for a grid-interactive multi-zone building where the temperature dynamics are learned via Gaussian Process (GP) regression. We investigate the development of a learning-based predictive control with two main objectives: (i) continuously learn the temperature dynamics of the building based on data; and, (ii) use the learned dynamics to solve a multi-objective predictive control problem to guarantee occupants' comfort and energy efficiency during normal conditions and demand response events. We leverage the probabilistic non-parametric properties of GPs to estimate the (unknown) non-linear temperature dynamics of the building and to incorporate the uncertainty of those predictions in a multi-objective optimization problem. The GP-based predictive control is solved via a zero-order primal-dual projected-gradient algorithm. We evaluate numerically the performance of the proposed controller using a five-zone commercial building.

demand response↗

Performance evaluation of a dynamic wall integrated with active insulation and thermal energy storage systems

Thermal energy storage systems in buildings can store cooling/heating energy during non-peak load hours or when renewable energy sources are available for later use when demanded. Using the building envelope as a thermal battery can help to shave the peak load, reduce the burden in electric grids, and enhance the occupant's thermal comfort. Sensible energy storage on wall systems such as thermally activated building systems can provide an active thermal storage strategy. However, most of the stored energy is used through passive means directed by the thermal lag, which can impede the on-demand release of the stored energy. Integrating active insulation systems with building thermal storage systems can increase the flexibility of charging and discharging time and duration. In this study, a wall system equipped with an active insulation system and thermally activated storage system was designed, and its performance on active cooling energy contribution was studied. The performances of energy storage (charging), release (discharging) of the thermal energy storage energy, and the active insulation system were studied separately and together as an integrated system. Results showed that the thermal properties of the thermal energy storage core material and the pipe spacing of both embedded pipes in the thermal energy storage and hydronic pipes used in the active insulation system affected the wall performance the most out of all the tested wall system parameters. During discharging, the heat flux into the wall was as high as 81.92 W/m 2 . This active insulation system's dynamic R-value varied between less than 1ft 2 •°F•h/BTU (0.18 m 2 •K/W) to 98% of the equally thick foam insulation's R-value.

25 ENERGY STORAGE↗

Hydrogen adsorption and transport in clay-rich geomaterials: Implications for large-volume underground hydrogen storage

Depleted oil and gas reservoirs, characterized by impermeable clay-rich caprocks, are promising sites for large-scale underground hydrogen storage (UHS), which is a key strategy to support hydrogen-based energy systems. However, experimental data on hydrogen storage in clay-rich geomaterials remain scarce. In this work, we experimentally investigated hydrogen adsorption and migration in clay-rich geomaterials in the presence of nitrogen and water under controlled temperatures. Experimental observations showed that hydrogen was adsorbed in dry illite. A dual-porosity transport model was developed to interpret hydrogen transport between large-pore and small-pore domains in illite. The large-pore domain is the space between clay particles (i.e., inter-particle space), whereas the small-pore domain is the nanoscale pore space between clay mineral layers (i.e., inter-layer or intra-particle space). In contrast, nitrogen showed no evidence of adsorption in dry illite because it cannot move into the small-pore domain due to the relatively large kinetic diameter, referred to as the molecular sieving effect. Here, we found that 0.7–1.3 nm is the length scale regulating this molecular sieving effect, matching the interlayer spacing in illite, suggesting that nitrogen is a promising cushion gas in UHS, which aims to maintain adequate pressure in the reservoir for economic operations. In wetted illite, hydrogen was not adsorbed into the interlayer space due to the occupation of adsorption sites by interlayer water, which highlights the critical role of the clay hydration state in controlling hydrogen-clay interactions. Additionally, hydrogen adsorption experiments on crushed shale indicated that the shale surface possessed adsorption sites more favorable for hydrogen than for nitrogen. Through these experiments, we provide new insights into hydrogen storage mechanisms in clay-rich geomaterials and offer valuable laboratory data for evaluating the performance of large-scale UHS systems.

Adsorption↗

Oxidation rates and redox stabilization of ferrous iron in trioctahedral smectites

Iron(II)-bearing trioctahedral smectites (saponites) form during anoxic alteration of basaltic rock. They are predicted to have been widespread on the early Earth and are observed in the oceanic subsurface today. Smectite structures, including the occupancy of sites in the octahedral sheet, affect iron redox behavior but the rates and products of trioctahedral smectite oxidation have been largely unexplored to date. In this study we synthesized two Fe(II)-bearing trioctahedral smectites, one moderate (22 wt% Fe) and one high (27 wt% Fe) in iron content. We then examined the rate, extent, and products of their oxidation by dissolved oxygen, nitrite, and hydrogen peroxide. Dissolved oxygen caused partial oxidation of Fe(II) in the smectites with 14 to 43% of Fe(II) unoxidized after 20 to 30 days of exposure. The rate and extent of oxidation correlated with the dissolved oxygen concentration and the Fe(II) content of the clay. The incomplete oxidation in these experiments is consistent with the mixed-valent trioctahedral smectites observed in oxidized natural samples but contrasts with the complete reoxidation by oxygen shown by chemically- or microbially-reduced dioctahedral smectites. Oxidation of structural Fe(II) by 5 mmol L -1 nitrite was negligible for the moderate-iron smectite and yielded only ~17% oxidation after 54 days of reaction for the high-iron smectite. Hydrogen peroxide caused rapid and near-complete oxidation of both clays. Powder X-ray diffraction, variable-temperature Mössbauer spectroscopy, and extended X-ray absorption fine structure spectroscopy together detected no crystalline or short-range-ordered secondary phases and show that oxidized iron remained in the trioctahedral smectite structure. The recalcitrant Fe(II) pool in oxidized trioctahedral smectites exists in less distorted sites than Fe(II) in the initial clays. Its unreactive nature at prolonged reaction times indicates an elevated redox potential generated by the local coordination environment. Slower oxidation rates create a larger recalcitrant Fe(II) pool, suggesting kinetic competition between oxidation and a process involved in redox stabilization, such as electron exchange between octahedral iron sites or deprotonation of hydroxyl groups in the structure. The resistance to complete oxidation of trioctahedral ferrous smectites and their full retention of iron demonstrates that transitions from anoxic to oxic conditions generate mixed-valence smectites rather than a mixture of new phases. Identifying the diagenetic products of mixed-valent trioctahedral smectites may provide an indicator in the rock record of past redox cycling. In conclusion, substantial portions of structural Fe(II) in trioctahedral smectites display slow abiotic oxidation kinetics and represent potential electron donors for both microaerophilic iron oxidizing and nitrate-reducing, iron-oxidizing microorganisms in altered mafic rocks and related settings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Role of opacity at the 9 keV back lighter energy used in measuring the equation of state of boron at pressures up to a Gbar

Many experiments have been conducted at the National Ignition Facility to measure the equation of state Hugoniot of plastic, boron, and diamond at extreme pressures up to a Gbar. The “Gbar” design employs a strong spherically converging shock launched through a solid ball of material using a hohlraum radiation drive. The shock front conditions are characterized using X-ray radiography, typically at energies near 9 keV. Here we examine how the opacity of boron at 9 keV changes at high pressures and temperatures. Understanding this is vital to unfolding the density in the shock front as pressures exceed 100 Mbar. We compare opacity calculations from a number of methods including the legacy XSN opacity tables, super transition array (STA), average atom (AVAT), and detailed configuration accounting (DCA) methods. We examine how the changing opacity is correlated with the K-shell occupation calculated using the opacity methods as well as other electronic structure methods such as MECCA, Purgatorio, and an all-electron Kohn-Sham density functional theory calculation that uses optimized all-electron norm-conserving Vanderbilt pseudopotentials (ONCV). We also examine the relative contribution of free-free opacity to the overall opacity, which is dominated by bound-free absorption.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Individual low-carbon behaviors and influencing factors: Insights from a behavior survey study in China

Climate change is a major global concern. Greenhouse gas emissions that cause global climate change are directly or indirectly affected by human activities. Individual low-carbon behaviors are crucial in reducing CO 2 emissions and improving environmental and ecological health. To effectively promote individual low-carbon behavior, this study designed a questionnaire on the factors influencing individual low-carbon intentions and behavior based on theoretical models of environmental behavior. A total of 2430 valid questionnaires were collected in China. This study focuses on analyzing the impact of demographic characteristics, internal and external factors on individual low-carbon behaviors and their interrelationships. The research shows correlations between internal and external factors in determining low-carbon intention or behaviors. Internal factors-related low-carbon behavior is not closely linked with demographic variables, whereas the external factors-related low-carbon behavior vary significantly by age, residence, education, marital status, occupation, and income. The findings have important implications for designing effective policies to promote low-carbon behaviors, such as creating a more favorable external environment and increasing the use of policy tools for reducing CO 2 emission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Weighted Composition Operators for Learning Nonlinear Dynamics

Operator theoretic methods in dynamical system have been dominated by the use of Koopman operators and their continuous time counterparts, such as Koopman Generators and Liouville Operators. The advantage gained from their use primarily stems from the ability to extract subspaces and eigenfunctions within a space of observables that are invariant with respect to the Koopman operator over that space. When this occurs, a dynamic mode decomposition of the systems state provides a linear model for the dynamical system. Not all Koopman operators have eigenfunctions that may be exploited in this manner. However, the framework can still be leveraged for approximations using other operators. In this setting, we present a different operator for the study of dynamical systems, the weighted composition operator. These operators are compact for a wide range of dynamics and spaces, and through their interactions with occupation kernels and vector valued kernels, they admit an estimation of the underlying dynamics. Here, this manuscript presents a new algorithm for the data driven study of dynamical systems from data, and also provides two numerical experiments where convergence is achieved as a proof of concept.

97 MATHEMATICS AND COMPUTING↗

CO 2 Pipeline risk assessment and comparison for the midcontinent United States

For this work, a comprehensive quantitative risk assessment for the construction and operation of CO 2 transportation networks considered for the Midcontinent United States was conducted. The results showed risks associated with CO 2 pipelines were significantly less than those of other pipeline types. The assessment used four conceptual pipelines of different lengths to discuss risks operators may see. The assessment evaluated the risk associated with construction and operation using data from the US Occupational Safety Health Administration to determine the risk of injury or death for pipeline workers and data from the US Pipeline and Hazardous Materials Safety Administration for CO 2 , natural gas distribution, natural gas transmission/gathering, and non-CO 2 hazardous liquid pipelines to develop quantitative likelihood and severity values leading to risk values. The data for the assessment covered incidents from 2010 to 2017 for CO 2 pipelines. The average risk for construction and 30 years of operation for four CO 2 pipeline configurations ranging between 79 and 1,546 miles in length was found. The construction and operational risk averaged between $\$1,400,521$ (approximately $\$0.02$/tonne of CO 2 ) for the shorter pipeline (79 miles) and $\$27,481,939$ (approximately $\$0.10$/tonne of CO 2 ) for a longer pipeline (1,546 miles). The largest risks of fatality for CO 2 pipelines comes from vehicle transport. The largest operational risk to the pipeline was due to leakage. Public pipeline opposition is also a significant risk; it was not quantified but is addressed.

03 NATURAL GAS↗