Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Next”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

A New Multi-Scale State Estimation Framework for the Next Generation of Power Grid EMS

Accurate system state information under various operation conditions is a prerequisite for power grid monitoring and efficient control. To achieve that goal, a new multi-scale state estimation framework is proposed, paving the way for the development of next generation of energy management system (EMS). The developed framework consists of three key components, namely the static state estimation (SSE) module, the dynamic state estimation (DSE) module, the interfaces and switching logics between the two modules. Specifically, the singular spectrum analysis (SSA)-based change point detection approach is developed to monitor the system continuously. If no event is detected by the SSA, the robust SSE using both SCADA and PMU measurements is executed. Otherwise, the event is declared and the results from SSE are used to derive the initial condition for DSE. During the transient process, only PMU-based DSE is executed for system monitoring and it will be terminated when SSA does not detect any change point of the system. After that, the DSE results are forwarded for SSE initialization and bus voltage magnitude and angle estimations. Simulation results carried out on the IEEE 39-bus system demonstrate the effectiveness and benefits of the proposed framework.

Power system state estimation, energy management s↗

Modeling Grid Data Flows for Transmission and Distribution Operations: Review, Design, Next Steps

Operational scenarios of the power grids grow multifold to accommodate the diverse needs of both the utilities and end consumers, and the various other stakeholders in-between. To comprehensively model and apply analytics to support objectives and business functions of grid sectors, a reliable approach to characterize and design data flows is crucial. The flows bridge business functions with communications protocols, stakeholders such as the grid actors, and data interfaces comprising different data objects. Additionally, constraints applied to the flow such as cybersecurity, trust, privacy, and ownership among others intersect these entities, requiring the delineation of their interactions under different scenarios. This paper aims to not only highlight relevant research in the space of grid data flows, but also proposes, for the transmission-distribution sector, a novel modeling approach that marries the aforementioned entities: objectives, business functions, data interfaces, communication protocols, data stakeholders, and flow constraints. It elaborates on the design philosophy and the significance of each entity within the model and applies it to an example function of fault location, isolation and service restoration (FLISR). Finally, the next steps to extend the application of this data flow model for other practical operational scenarios are discussed.

Sundararajan, Aditya [ORNL] (ORCID:000000033577854↗

Hardware-in-the-Loop Evaluation of Grid-Edge DER Chip Integration Into Next-Generation Smart Meters

To facilitate the implementation of distributed energy resource management systems (DERMS), we propose to insert a grid-edge distributed energy resource (DER) chip hosting a DERMS algorithm into the next generation of smart meters. This will create a pathway for the wide adoption of DERMS technology because many utilities plan to invest in advanced metering infrastructure in the near future. This will also bridge the gap between an electrical power utility and DERs behind the meter. The DER chip is designed to follow power direction signals from the DERMS coordinator while balancing its local objectives. We tested the chip using a controller- and power-hardware-in-the-loop evaluation under three scenarios that a DERMS could face in the real world. The DER chip was capable of and effective at directing four heterogeneous DERs to respond to a DERMS coordinator for grid services (e.g., voltage regulation and a virtual power plant).

distributed energy resource management system↗

DIII-D accomplishments and plans in support of fusion next steps

DIII-D is using its flexibility and diagnostics to address the critical science required to enable next step fusion devices. We have adapted operating scenarios for ITER to low torque and are now being optimized for transport. Three ELM mitigation scenarios have been developed to near-ITER parameters. New control techniques are managing the most challenging plasma instabilities. Disruption mitigation tools show promising dissipation strategies for runaway electrons and heat load. An off axis neutral beam upgrade has enabled sustainment of high βN capable steady state regimes. Divertor research is identifying the challenge, physics and candidate solutions for handling the hot plasma exhaust with notable progress in heat flux reduction using the snowflake configuration. Our work is helping optimize design choices and prepare the scientific tools for operation in ITER, and resolve key elements of the plasma configuration and divertor solution for an FNSF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fabrication of a Nb-Ti Superconducting Closed-Loop Coil for the Next-Generation 45 GHz ECR Ion Source MARS-D

Electron Cyclotron Resonance Ion Sources (ECRISs) that utilize Nb-Ti superconducting coils for 28 GHz frequencies have been operating effectively for over twenty years. However, transitioning to higher frequencies demands stronger magnetic fields, and the conventional racetrack-and-solenoid ECRIS structures have reached their maximum capability with Nb-Ti. To address this, a Mixed Axial and Radial field System Demonstrator (MARS-D) is being developed at Lawrence Berkeley National Laboratory (LBNL). This system features an innovative Closed-Loop Coil (CLC) design that optimizes the use of the conductor fields, enabling the application of Nb-Ti in the next-generation 45 GHz ECRISs. The fabrication of the hexagonal CLC is particularly challenging due to its complex winding path and shape, the stiffness of the Nb-Ti superconducting wire, and the small bending radius. Here, to address these challenges, a series of unique fixtures and tools, as well as a pre-over-bending method, were developed for winding the CLC. To validate the winding fixtures, tools, procedures, and materials used in the coil assembly, a 4-layer practice CLC was wound, epoxy-impregnated, and then cold-tested using liquid nitrogen. The full-size MARS-D CLC is in the process of winding. This paper presents the structure of the MARS-D CLC, the winding fixtures and tools, the winding procedures, the quality control, the impregnation, the test results, and the potential future improvements.

ECR ion sources↗

Design of a Structure for Assembly and Cooling the Magnet of the Next-Generation 45 GHz ECR Ion Source MARS-D

Here, the current Electron Cyclotron Resonance Ion Sources (ECRISs), constructed with Nb-Ti wires and the conventional racetrack-and-solenoid structure, have achieved operating frequencies up to 28 GHz and utilized about 90% of the critical current of the Nb-Ti wire. A Mixed Axial and Radial field System Demonstrator (MARS-D) is being developed at Lawrence Berkeley National Laboratory (LBNL). This system, which consists of an innovative hexagonal Closed-Loop Coil (CLC) and a set of solenoids, can generate higher magnetic fields (up to 150% ) while requiring only about 50% of the superconducting wire, enabling Nb-Ti wires to be used in the next-generation 45 GHz ECRIS. However, the assembly and cooling of such an efficient and compact magnet are particularly challenging due to the small radial gap between the CLC and solenoids, as well as the tight operating temperature margin. To address these challenges, a structure was developed that combines a three-section radially split solenoid mandrel with a series of shrink-fit reinforcement rings and cooling channels. This paper presents the detailed structure, manufacturing method, assembly procedure, impregnation method, mechanical Finite Element Analysis (FEA) comparison, and thermal FEA comparison.

ECR ion sources↗

Next Generation Ta-STJ Sensor Arrays for BSM Physics Searches

The Beryllium Electron capture in Superconducting Tunnel junctions (BeEST) experiment uses superconducting tunnel junction (STJ) sensors to search for physics beyond the standard model (BSM) with recoil spectroscopy of the 7 Be EC decay into 7 Li. A pulsed UV laser is used to calibrate the STJs throughout the experiment with ∼20 meV precision. Phase-III of the BeEST experiment revealed a systematic calibration discrepancy between STJs. We found these artifacts to be caused by resistive crosstalk and by intensity variations of the calibration laser. For phase-IV of the BeEST experiment, we have removed the crosstalk by designing the STJ array so that each pixel has its own ground wire. We now also use a more stable UV laser for calibration. The new STJ arrays were fabricated at STAR Cryoelectronics and tested at LLNL and FRIB. They have the same high energy resolution of ∼1-2~eV in the energy range of interest below 100~eV as before, and they no longer exhibit the earlier calibration artifacts. We discuss the design changes and the STJ array performance for the next phase of the BeEST experiment.

Laser Calibration↗

Next-Cycle Optimal Dilute Combustion Control via Online Learning of Cycle-to-Cycle Variability Using Kernel Density Estimators

Dilute combustion using exhaust gas recirculation (EGR) presents a cost-effective method for increasing the efficiency of spark-ignition (SI) engines. However, the maximum amount of EGR that can be used at a given condition is limited by a rapid increment of cycle-to-cycle variability (CCV). This study describes a methodology to design a model-based stochastic optimal controller to adjust the cycle-to-cycle fuel injection quantity in order to reduce CCV and further extend the dilute limit. Given the complexity and chaotic nature of combustion events, the controller was enhanced with online learning in order to identify the statistical properties of combustion efficiency, which are needed to generate predictions for next-cycle events. This study showed that a kernel density estimator (KDE) can be used to learn the combustion properties in real time and can be incorporated into the feedback policy in order to calculate the optimal control command. Experimental results suggested that the dilute limit can be extended from 18.5% to 21% EGR fraction at an operating condition relevant for highway cruising. Additionally, the proposed controller can achieve a large CCV reduction with less fuel enrichment compared to previous methods, overall contributing to an increase in 0.2% indicated fuel conversion efficiency.

33 ADVANCED PROPULSION SYSTEMS↗

A Next-Generation Countermeasure Architecture to Prevent Explosives Attacks at Large Public Events

A concept has been developed for a next-generation integrated countermeasure architecture to detect improvised explosive devices hidden on people or left behind in unstructured crowds. The work is part of the Standoff Technology Integration and Demonstration Program of the U.S. Department of Homeland Security’s Science and Technology Directorate. The architecture is based on results from an initial design tested in crowd conditions and a broad survey of existing and emerging technologies. The architecture uses a layered-defense approach that automates screening operations and prioritizes threats and mobilizes resources accordingly. A system tracks people as they move, integrating sensors to optimize threat identification accuracy and screening resources. A threat-based decision module prioritizes screening targets based on user-defined rules. Operators manage system-wide risk and mobilize field teams for interdiction. DHS is working with industry on technology development and testing to achieve the required level of system integration and economics in crowd conditions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Characterization of CLYC Detectors for a Next-Generation Unattended Sensor

We are developing a next-generation unattended sensor for detecting anomalous radiation sources. The system uses a scintillator material with dual sensitivity to gamma rays and neutrons, Cs 2 LiYCl 6 :Ce (CLYC), to reduce the size and complexity of the design. CLYC also offers a best-case energy resolution under 4% full width at half maximum at 662 keV, and allows for particle discrimination by pulse amplitude as well as pulse shape. The unattended sensor features sixteen one-inch CLYC detectors, each read out by a photomultiplier tube and custom readout electronics. A field-programmable gate array implements a suite of efficient processing algorithms for anomaly detection and isotope identification, and transmits alarm information to a base station via a wireless link. The system is designed to operate on battery power for several weeks. In this paper, we report the energy resolution, linearity, detection efficiency, and temperature stability of the first CLYC detectors acquired for the project. Rather than characterizing the scintillator material under ideal conditions, we evaluate the detectors with the components selected for the unattended sensor, acknowledging the tradeoffs imposed by small size, limited power budget, and uncontrolled environmental conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System Modeling and Design Optimization for a Next-Generation Unattended Sensor

We are developing a next-generation unattendedsensor that can detect and identify radiation sources while operating on battery power for several weeks. The system achieves smaller size and weight over systems that use NaI:Tl and 3He detectors by using a relatively new scintillator, Cs2LiYCl6:Ce:Ce (CLYC). This material can detect both gamma rays and thermal neutrons, has energy resolution of ~4% full width at half maximum at 662 keV, and allows for particle discrimination by pulse amplitude as well as pulse shape. The overall design features an array of sixteen CLYC detectors, each read out by a photomultiplier tube and custom pulse processing electronics. A field-programmable gate array analyzes the energy spectra using computationally efficient algorithms for anomaly detection.

McDonald, Benjamin S.↗

Nucleotide polymorphism and copy number variant detection using exome capture and next-generation sequencing in the polyploid grass Panicum virgatum

Switchgrass (Panicum virgatum) is a polyploid, outcrossing grass species native to North America and has recently been recognized as a potential biofuel feedstock crop. Significant phenotypic variation including ploidy is present across the two primary ecotypes of switchgrass, referred to as upland and lowland switchgrass. The tetraploid switchgrass genome is approximately 1400 Mbp, split between two subgenomes, with significant repetitive sequence content limiting the efficiency of re-sequencing approaches for determining genome diversity. To characterize genetic diversity in upland and lowland switchgrass as a first step in linking genotype to phenotype, we designed an exome capture probe set based on transcript assemblies that represent approximately 50 Mb of annotated switchgrass exome sequences. We then evaluated and optimized the probe set using solid phase comparative genome hybridization and liquid phase exome capture followed by next-generation sequencing. Using the optimized probe set, we assessed variation in the exomes of eight switchgrass genotypes representing tetraploid lowland and octoploid upland cultivars to benchmark our exome capture probe set design. We identified ample variation in the switchgrass genome including 1 395 501 single nucleotide polymorphisms (SNPs), 8173 putative copy number variants and 3336 presence/absence variants. While the majority of the SNPs (84%) detected was bi-allelic, a substantial number was tri-allelic with limited occurrence of tetra-allelic polymorphisms consistent with the heterozygous and polyploid nature of the switchgrass genome. Collectively, these data demonstrate the efficacy of exome capture for discovery of genome variation in a polyploid species with a large, repetitive and heterozygous genome.

54 ENVIRONMENTAL SCIENCES↗

Improved noise performance from the next-generation buried-channel p-MOSFET SiSeROs

The Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. In our earlier work, we characterized a number of first prototype SiSeROs with the MOSFET transistor channels at the surface layer. An equivalent noise charge (ENC) of around 15 electrons root mean square (RMS) was obtained. In this work, we examine the first buried-channel SiSeRO. Here we have achieved substantially improved noise performance of around 4.5 electrons root mean square (RMS) and a full width half maximum (FWHM) energy resolution of 132 eV at 5.9 keV, for a readout speed of 625 kpixel/s. We also discuss how digital filtering techniques can be used to further improve the SiSeRO noise performance. Additional measurements and device simulations will be essential to further mature the SiSeRO technology. This new device class presents an exciting new technology for the next-generation astronomical X-ray telescopes requiring fast, low-noise, radiation-hard megapixel imagers with moderate spectroscopic resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Activator-doped Hg 2 Br 2 as next generation high performance scintillator for high energy physics research and other scientific and imaging applications

Existing COTS inorganic scintillators all have the characteristic of being very good at certain desirable properties, but not sufficient at other desirable properties for HEP. The demand for suitable scintillators (with regards to both scintillation detector properties and suitable pricing), to be used for modern intensities frontier (Mu2e-II), energy frontier (High luminosity large hadron collider) and future e+e- collider projects (aimed as Higgs bosons factory, such as the International Linear Collider (ILC) and the Future Circular Collider (FCC) are putting even higher challenges on crystal scintillators.In this work, we report the development of a novel high-performance scintillators that can address the issues associated with existing scintillators, the activator doped Hg2Br2. Initial results are very encouraging on the detection of gamma and alpha particles using a solid-state photomultiplier (SSPM). The responses have been stable and repeatable. Hg2Br2 also has many advantages over existing COTS scintillators such as: high density, bright, fast, good energy resolution, no intrinsic radiation, radiation hard and cost-effectiveness. Here, we present here why Hg2Br2 is the next generation scintillator for high energy physics experiments as well as other scientific and imaging applications such as planetary science and medical imaging.

36 MATERIALS SCIENCE↗

Breast cancer imaging: A perspective for the next decade

Breast imaging is largely indicated for detection, diagnosis, and clinical management of breast cancer and for evaluation of the integrity of breast implants. In this work, a prospective view of techniques for breast cancer detection and diagnosis is provided based on an assessment of current trends. The potential role of emerging techniques that are under various stages of research and development is also addressed. It appears that the primary imaging tool for breast cancer screening in the next decade will be high-resolution, high-contrast, anatomical x-ray imaging with or without depth information. MRI and ultrasonography will have an increasingly important adjunctive role for imaging high-risk patients and women with dense breasts. Pilot studies with dedicated breast CT have demonstrated high-resolution three-dimensional imaging capabilities, but several technological barriers must be overcome before clinical adoption. Radionuclide based imaging techniques and x-ray imaging with intravenously injected contrast offer substantial potential as a diagnostic tools and for evaluation of suspicious lesions. Developing optical and electromagnetic imaging techniques hold significant potential for physiologic information and they are likely to be of most value when integrated with or adjunctively used with techniques that provide anatomic information. Experimental studies with breast specimens suggest that phase-sensitive x-ray imaging techniques can provide edge enhancement and contrast improvement but more research is needed to evaluate their potential role in clinical breast imaging. From the technological perspective, in addition to improvements within each modality, there is likely to be a trend towards multi-modality systems that combine anatomic with physiologic information. We are also likely to transition from a standardized screening, where all women undergo the same imaging exam (mammography), to selection of a screening modality or modalities based an individual-risk or other classification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Completeness map evaluation demonstrated with candidate next-generation cardiac CT architectures

Purpose: In this report, the authors introduce the general concept of the completeness map, as a means to evaluate the completeness of data acquired by a given CT system design (architecture and scan mode). They illustrate the utility of completeness map by applying the completeness map concept to a number of candidate CT system designs, as part of a study to advance the state-of-the-art in cardiac CT. Methods: In order to optimally reconstruct a point within a volume of interest (VOI), the Radon transform on all possible planes through that point should be measured. The authors quantified the extent to which this ideal condition is satisfied for the entire image volume. They first determined a Radon completeness number for each point in the VOI, as the percentage of possible planes that is actually measured. A completeness map is then defined as a 3D matrix of the completeness numbers for the entire VOI. The authors proposed algorithms to analyze the projection datasets in Radon space and compute the completeness number for a fixed point and apply these algorithms to various architectures and scan modes that they are evaluating. In this report, the authors consider four selected candidate architectures, operating with different scan modes, for a total of five system design alternatives. Each of these alternatives is evaluated using completeness map. Results: If the detector size and cone angle are large enough to cover the entire cardiac VOI, a single-source circular scan can have {>=}99% completeness over the entire VOI. However, only the central z-slice can be exactly reconstructed, which corresponds to 100% completeness. For a typical single-source architecture, if the detector is limited to an axial dimension of 40 mm, a helical scan needs about five rotations to form an exact reconstruction region covering the cardiac VOI, while a triple-source helical scan only requires two rotations, leading to a 2.5x improvement in temporal resolution. If the source and detector of an inverse-geometry (IGCT) system have the same axial extent, and the spacing of source points in the axial and transaxial directions is sufficiently small, the IGCT can also form an exact reconstruction region for the cardiac VOI. If the VOI can be covered by the x-ray beam in any view, a composite-circling scan can generate an exact reconstruction region covering the VOI. Conclusions: The completeness map evaluation provides useful information for selecting the next-generation cardiac CT system design. The proposed completeness map method provides a practical tool for analyzing complex scanning trajectories, where the theoretical image quality for some complex system designs is impossible to predict, without yet-undeveloped reconstruction algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-FG-BRA-05: Next Generation Radiotherapy Biomaterials Loaded With Gold Nanoparticles

Purpose: It has been proposed that routinely used inert radiotherapy (RT) biomaterials (e.g. fiducials, spacers) can be upgraded to smarter ones by coating/loading them with radiosensitizing gold nanoparticles (GNPs), for sustained in-situ release after implantation to enhance RT. In this work, we developed prototypes of such RT biomaterials and investigated the sustained release of GNPs from the biomaterials as a function of design parameters. Methods: Prototype smart biomaterials were produced by incorporating the GNPs in poly(D,L-lactide-co-glycolide) (PLGA) polymer millirods during the gel phase of production. For comparison, commercially available spacers were also coated with a polymer film loaded with fluorescent GNP. Optical/spectroscopy methods were used to monitor in vitro release of GNPs over time as a function of different design parameters: polymer weighting, type, and initial (loading) GNP concentrations. Inductively coupled plasma mass spectrometry was employed to verify GNP release. Results: Results showed that gold nanoparticles could be successfully loaded in the new RT biomaterial prototypes. Burst release of GNPs could be achieved within 1 to 25 days depending on the preparation approach. Burst release was followed by sustained release profile over time. The amount of released GNP increased with increasing loading concentration as expected. The release profiles could also be customized as a function of polymer weighting, or preparation approaches. Conclusion: Considered together, our results highlight potential for the development of next generation RT biomaterials loaded with GNPs customizable to different RT schedules. Such biomaterials could be employed as needed instead of currently used inert spacers/fiducials at no additional inconvenience to patients, to enhance RT.

60 APPLIED LIFE SCIENCES↗

Identifying a next-generation antimalarial trioxolane in a landscape of artemisinin partial resistance

For over two decades, artemisinin-based combination therapy (ACT) has been the standard of care for the treatment of uncomplicated falciparum malaria. However, artemisinin partial resistance (ART-R) is now prevalent in Southeast Asia and has emerged in eastern Africa, threatening ACT efficacy. Artefenomel, a synthetic 1,2,4-trioxolane, exhibits an extended pharmacokinetic exposure profile that predicts for efficacy against ART-R parasites. Unfortunately, the development of artefenomel was halted recently after almost a decade in the clinic. Here, we describe studies of an artefenomel-adjacent chemotype that combines potent in vitro activity against clinical ART-R parasites, an extended pharmacokinetic profile with single-exposure efficacy in a murine malaria model, and enhanced stability in human microsomes and hepatocytes. Overall, our studies reveal a heretofore underexplored trioxolane chemotype with the potential to address ART-R in a next-generation trioxolane development candidate.

Science & Technology - Other Topics↗