Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Atmospheric neutrino oscillation analysis with neutron tagging and an expanded fiducial volume in Super-Kamiokande I–V

We present a measurement of neutrino oscillation parameters with the Super-Kamiokande detector using atmospheric neutrinos from the complete pure-water SK I–V (April 1996–July 2020) dataset, including events from an expanded fiducial volume. The dataset corresponds to 6511.3 live days and an exposure of 484.2 kiloton-years. Measurements of the neutrino oscillation parameters Δ⁢𝑚$^2_{3⁢2}$, sin 2 ⁡𝜃 2⁢3 , sin 2⁡ 𝜃 1⁢3 , 𝛿 CP , and the preference for the neutrino mass ordering are presented with atmospheric neutrino data alone, and with constraints on sin 2 ⁡𝜃 1⁢3 from reactor neutrino experiments. Our analysis including constraints on sin 2 ⁡𝜃 1⁢3 favors the normal mass ordering at the 92.3% level.

Cherenkov detectors↗

Constraints on the Electromagnetic Counterpart of the Neutron-star–Black-hole Merger GW200115

We report the results of our follow-up campaign for the neutron-star—black-hole (NSBH) merger GW200115 detected during the O3 run of the Advanced LIGO and Advanced Virgo detectors. We obtained wide-field observations with the Deca-Degree Optical Transient Imager covering ~20% of the total probability area down to a limiting magnitude of w = 20.5 AB at ~23 hr after the merger. Our search for counterparts returns a single candidate (AT2020aeo), likely not associated with the merger. In total, only 25 sources of interest were identified by the community and later discarded as unrelated to the GW event. We compare our upper limits with the emission predicted by state-of-the-art kilonova simulations and disfavor high-mass ejecta (>0.1 M⊙), indicating that the spin of the system is not particularly high. By combining our optical limits with gamma-ray constraints from Swift and Fermi, we disfavor the presence of a standard short-duration burst for viewing angles ≲15° from the jet axis. Our conclusions are, however, limited by the large localization region of this GW event, and accurate prompt positions remain crucial to improving the efficiency of follow-up efforts.

79 ASTRONOMY AND ASTROPHYSICS↗

SANDD: A directional antineutrino detector with segmented 6 Li-doped pulse-shape-sensitive plastic scintillator

We present a characterization of a small (9-liter) and mobile 0.1% 6 Li-doped pulse-shape-sensitive plastic scintillator antineutrino detector called SANDD (Segmented AntiNeutrino Directional Detector), constructed for the purpose of near-field reactor monitoring with sensitivity to antineutrino direction. SANDD comprises three different types of module. A detailed Monte Carlo simulation code was developed to match and validate the performance of each of the three modules. The combined model was then used to produce a prediction of the performance of the entire detector. Analysis cuts were established to isolate antineutrino inverse beta decay events while rejecting large fraction of backgrounds. The neutron and positron detection efficiencies are estimated to be 34.8% and 80.2%, respectively, while the coincidence detection efficiency is estimated to be 71.7%, resulting in inverse beta decay detection efficiency of 20.0% ± 0.2%(stat.) ± 2.1%(syst.). Finally, the predicted directional sensitivity of SANDD produces an uncertainty of 20° in the azimuthal direction per 100 detected antineutrino events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Assessment of PHDS Fulcrum40h and Ortec Detective-X High Purity Germanium (HPGe) Detector System Performance

This report provides a summary of measurement results used to compare the performance of the PHDS Fulcrum40h and Ortec Detective-X High Purity Germanium (HPGe) detector systems. Specifically, the measurement data collected was used to assess each detector system for gamma efficiency and resolution, gamma angular response and efficiency for an in-situ surface distribution, neutron efficiency, gamma pulse-pileup response, and gamma to neutron crosstalk.

42 ENGINEERING↗

193 mIr/ 192 Ir ratio from irradiation with various NCERC critical assemblies

Eight irradiations of K 2 IrCl 6 pellets were carried out with three critical assemblies: Flattop-Oy, Flattop-Pu and Godiva IV. One of the irradiations was performed with three pellets at different locations of the critical assembly, while the other irradiations with pellets at the center, but operating the critical assembly at different power and, respectively, different neutron flux. Counting samples were prepared from the irradiated pellets and X-ray spectra measured with silicone drift detectors. The 193 mIr/ 192 Ir ratio is reported for each irradiation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Burnup Monitoring for Pebble Bed Reactor Systems

A pebble burnup monitoring system is a required component for domestic reactor safety and safeguards applications associated with pebble bed reactors (PBRs). One of the main requirements of a PBR burnup monitoring system is that it needs to be capable of rapid measurements to assess the burnup of each individual pebble to determine whether to recirculate it in the reactor or discard it as spent fuel. This report considers three different approaches for a burnup monitoring system for pebbles discharged from the reactor core in a pebble bed modular reactor-400: • passive gamma spectrometry measurement, • passive neutron coincidence measurement, and • active neutron counter based on the differential die-away technique. Conceptual designs have been created for each of these detectors, and preliminary analysis has been performed using Monte Carlo N-Particle and Oak Ridge Isotope Generation code simulations. The advantages and practical limitations (e.g., high radiation background) of each system were identified. Simulations suggest that each of the three measurement techniques can be successfully employed to distinguish between pebbles based on their number of passes through the core and to quantify the burnup of pebbles.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Machine learning-assisted identification of potential sources of bias in measurements of prompt-fission neutron spectra

Unrecognized sources of uncertainty (USU) can bias the reported mean and/or covariance of experimental nuclear data. These biases, in turn, can propagate through evaluated nuclear data to application simulations or may poorly inform nuclear theory that is fitted to the experimental data. Such unknown sources of bias must be tied to the inherent physical constituents of the measurements such as the characteristics of a detector response or a background reduction technique. Here, in this article, a sparse Bayesian learning model is used to support experts in their efforts to identify and characterize USU in experimental prompt fission neutron spectra (PFNS) for spontaneous fissioning of 252 Cf by linking observed biases to features of the measurement system. Three different bias components were found. The first acts as a verification case for the algorithm as it identifies a bias coming from a well-known source related to the use of 6 Li in the neutron detection system. The second two cases demonstrate how this method can benefit the evaluation of experimental nuclear data by identifying, quantifying, and relating unknown biases to potential causes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pulsed-Neutron Die-Away Response of H 2 O Targets to a D-T Neutron Generator Pulse

Pulsed-neutron die-away (PNDA) experiments were completed at Lawrence Livermore National Laboratory (LLNL). The goal of these experiments was to provide a benchmark to validate thermal neutron scattering laws of H 2 O. The experiment was conducted with a deuterium-tritium (D-T) neutron generator producing pulses of 14.1 MeV neutrons that impinged on a moderating target.

3He Detectors↗

Low spin spectroscopy of neutron-rich Cl 43 , 44 , 45 via β - and β n decay

In this article, β - decay studies of neutron-rich isotopes 43,45 S performed at the National Superconducting Cyclotron Laboratory are reported. β -delayed $\gamma$ transitions were detected by an array of 16 clover detectors surrounding the Beta Counting Station, which consists of a 40×40 double-sided silicon strip detector followed by a single-sided silicon strip detector. β -decay half-lives were extracted for 43,45 S by correlating implants and decays in the pixelated implant detector and by considering further coincidences with $\gamma$ transitions in the daughter nuclei. Further, the level structures of 43,45 Cl are expanded by the addition of 20 and 8 new $\gamma$ transitions in 43 Cl and 45 Cl respectively, and core-excited negative-parity states were observed in both nuclei for the first time. For 45 S, a large fraction of the β -decay strength was observed feeding neutron-unbound states in 45 Cl, which, decaying by delayed neutrons, populated excited states in the β ⁢1⁢ n daughter, 44 Cl. Experimental observations were compared to detailed shell-model calculations using the SDPFSDG-MU interaction to highlight the role of the diminished N = 28 neutron shell gap and the near degeneracy of the proton s 1/2 and d 3/2 orbitals in the structure of the neutron-rich Cl isotopes. The current work also provides further support to a ground-state spin-parity assignment of 3/2 + in 45 Cl.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EXPANSE: A time-of-flight EXPanded Angle Neutron Spin Echo spectrometer at the Second Target Station of the Spallation Neutron Source

EXPANSE, an EXPanded Angle Neutron Spin Echo instrument, has been proposed and selected as one of the first suite of instruments to be built at the Second Target Station of the Spallation Neutron Source at the Oak Ridge National Laboratory. This instrument is designed to address scientific problems that involve high-energy resolution (neV– μeV) of dynamic processes in a wide range of materials. The wide-angle detector banks of EXPANSE provide coverage of nearly two orders of magnitude in scattering wavenumbers, and the wide wavelength band affords approximately four orders of magnitude in Fourier times. This instrument will offer unique capabilities that are not available in the currently existing neutron scattering instruments in the United States. Specifically, EXPANSE will enable direct measurements of slow dynamics in the time domain over wide Q-ranges simultaneously and will also enable time-resolved spectroscopic studies. The instrument is expected to contribute to a diverse range of science areas, including soft matter, polymers, biological materials, liquids and glasses, energy materials, unconventional magnets, and quantum materials.

47 OTHER INSTRUMENTATION↗

Performance and Commissioning of the BigBite Timing Hodoscope for Nucleon Form Factor Measurements at Jefferson Lab

The BigBite Timing Hodoscope detector is the primary subject of this thesis. The Super BigBite Spectrometer is a Jefferson Lab Hall A Collaboration project that has and will continue to measure nucleon electromagnetic form factors. This spectrometer includes the Timing Hodoscope which provides high resolution particle timing data for scattered electrons in the electron arm of BigBite. The Timing Hodoscope utilizes 90, 25 × 25 × 600 mm3 scintillator bars stacked on top of each other to form a single detector plane, and these bars are connected to 180 photo-multiplier tubes via light guides. Particles collide with the scintillating material creating a shower of optical photons and these particle events in the bars are collected to generate signals that are readout by the data acquisition (DAQ) electronics. NINO ASIC amplifier-discriminator cards output signals from the photo-multiplier tubes into analogue and logic signals, which are sent to analogue-to-digital (ADC) and time-to-digital (TDC) converter data acquisition readout modules. This data is then used for analysis of the detector. The focus of this thesis is the construction, commissioning, calibration, and performance of the BigBite Timing Hodoscope before and during the first of five nucleon electromagnetic form factor experiments at Jefferson Lab Hall A. Before the neutron magnetic form factor, G n M, experiment, cosmic ray data was collected during commissioning to confirm proper operation of the Timing Hodoscope electronics by observing the ADC and TDC data. Commissioning studies for charge normalization, gain matching, and other ADC and TDC detector data variables were performed before moving the detector into Hall A. Following installation in Hall A, several calibration studies were implemented to fine-tune the detector in preparation for use in the experiment. The calibration studies included analysis of timing cuts, TDC alignment, the time-walk effect, time difference offsets, and scintillator velocity corrections. Once the Timing Hodoscope was well-calibrated, data-taking during the experiment commenced and the beam-on-target data was used to characterize the Timing Hodoscope performance during the G n M experiment run-time. The performance analysis included studies observing energy deposit, cluster size, rates, accidentals, pile-up, tracking efficiency, position resolution, and time resolution. After application of physics cuts to ensure a data set comprised of particle tracks corresponding to elastic electrons, which is the main data of interest for measurement of G n M, the Timing Hodoscope is shown on average across all kinematic settings to have a >98% tracking efficiency, a position resolution of 4-6 cm in the non-dispersive plane and 1.5-2 cm in the dispersive plane, and a time resolution of 500-750 ps. These performance results are compared to a GEANT4 based performance simulation of the BigBite Timing Hodoscope for reference, showing to what degree the measured performance values match those taken from the simulation.

Marinaro, Ralph↗

Search for a Sub-eV Sterile Neutrino Using Daya Bay’s Full Dataset

This Letter presents results of a search for the mixing of a sub-eV sterile neutrino with three active neutrinos based on the full data sample of the Daya Bay Reactor Neutrino Experiment, collected during 3158 days of detector operation, which contains 5.55 × 106 reactor $\overline{v}$ e candidates identified as inverse beta-decay interactions followed by neutron capture on gadolinium. The analysis benefits from a doubling of the statistics of our previous result and from improvements of several important systematic uncertainties. No significant oscillation due to mixing of a sub-eV sterile neutrino with active neutrinos was found. Exclusion limits are set by both Feldman-Cousins and CLs methods. Light sterile neutrino mixing with sin 2⁡ 2⁢θ 14 ≳ 0.01 can be excluded at 95% confidence level in the region of 0.01 eV 2 ≲ |Δ⁢$m$$^{2}_{41}$| ≲ 0.1 eV 2 . This result represents the world-leading constraints in the region of 2 × 10 –4 eV 2 ≲ |Δ⁢$m$$^{2}_{41}$| ≲ 0.2 eV 2 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Critical and Subcritical Californium Source Driven Noise Analysis Experiments with Fresh PWR Fuels Pins

These experiments were performed in 1983 between August 1 and September 16 and used 35 operational days of critical facility time at the Babcock & Wilcox critical facility in Lynchburg, Va. These measurements were to assess the capability of the Cf source driven noise analysis method to measure the subcriticality of light water reactor fresh fuel configurations. This report documents the experiments of 1983 that were not reported at that time. These measurement with 2.459 wt. % 235 U enriched uranium oxide fresh fuel pins started at the delayed critical configuration of the fully assembled pressurized water reactor (PWR) core configuration with 1511 parts per million (ppm) natural boron (19.8 wt. % 10 B) in the water. This was a cylindrical configuration of 4961 fuel pins. After the initial measurements at delayed criticality, subcritical measurements by the Cf source driven noise analysis method were performed in which the number of detectors and Cf source locations were varied. Additional boron was added to the water moderator and reflector to reduce the neutron multiplication factor, with resulting boron concentrations of 1561, 1613, 1765, 1880, 2104, 2384, 2975, 3606, and 4303 ppm. After the completion of these measurements the increased, the boron concentration was returned to that at delayed critical (1511 ppm) and the reactivity was decreased by reducing the number of fuel pins in steps to 3713, 2553, 1281, 749, and 333 fuel pins and then to that (289) of a s ingle square 17 x 17 pin array, corresponding to a single PW fuel element. For all measurement that started at delayed criticality and then reduced the neutron multiplication factor to various subcritical states, inverse kinetics rod drop measurements at the higher reactivities were also performed but not reported here. At all subcritical states the break frequency noise analysis data was fitted to obtain the prompt neutron decay constant. Some data presented in this report are from notes not in the logbook. The purpose of this report is to document the experimental information for the measurements performed so that a later date someone could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (INCSBEP) or Nuclear Energy Agency (NEA) benchmark. The data from these measurements is available from the Laboratory Records Department of Oak Ridge National Laboratory and the logbook is available from INCSBEP at Idaho National Laboratory.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Griffin Capability Improvements in Support of Ex-core Deep-Penetration Problems

Advanced reactor designs, especially portable reactors that are designed to be located closer to humans and operate autonomously, require the ability to accurately compute the ex-core neutron and gamma flux solutions in terms of shielding design optimization to reduce dose rates at the vessel boundary and detector signal prediction to drive the reactor control system. The Nuclear Energy Advanced Modeling and Simulation program has prioritized improvements to the Griffin discrete ordinates (SN) solver for deep-penetration problems in fiscal year 2025. Significant advancements have been made to the Griffin methodologies for solving ex-core deep-penetration problems for steady-state, fixed-source and transient calculations. This work presents the methodology improvements as well as a comprehensive demonstration with a Transient Test Reactor model and measurements.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Chasing Gamma-Ray Signals from Binary Neutron Star Coalescences with the Cherenkov Telescope Array: Prospects and Observing Strategies

The detection of gravitational waves (GWs) from a binary neutron star (BNS) merger by Advanced LIGO and Advanced Virgo (GW170817), together with its electromagnetic counterpart, the short gamma-ray burst GRB 170817A, heralded the birth of multimessenger astronomy. The detection of TeV emission from GRBs motivates follow-up observations with the Cherenkov Telescope Array Observatory (CTAO), which is ideal for detecting such signals due to its unprecedented sensitivity, rapid response, and wide-field survey capabilities. The aim of this work is to evaluate GeV–TeV GW follow-up strategies for CTAO using a multistep simulation pipeline and to estimate the expected rate of joint GW–GRB detections during observing run O5. Using a simulated sample of BNS systems with corresponding GW detections, gamma-ray emission is simulated through phenomenological prescriptions based on the observed population of short GRBs, including off-axis jet scenarios. CTAO observations are simulated to account for instrument response, sky tiling strategies, integration times, and varying observing conditions. Strategies with variable and constant integration times are investigated. We find that, via an optimized follow-up strategy, about 5% of simulated GW-associated short GRBs produce GeV–TeV radiation detectable by CTAO. Detectability is strongly influenced by the jet opening angle and viewing angle, suggesting that even rough estimates of the viewing angle in GW alerts could enhance targeting. This framework motivates future follow-ups of GW-detectable events, including neutron star–black hole mergers, and further supports the development of advanced strategies incorporating galaxy distributions and synergies with future detectors such as the Einstein Telescope.

Abe, S. [University of Tokyo] (ORCID:0000000172503↗

Updated Godiva-IV Benchmark Preview

A note of errata prepended to the Godiva-IV delayed-critical benchmark (HEU-MET-FAST- 086) identifies two corrections to be made to the model: The glory hole in the spindle should be made larger, and the height of the safety block should be made smaller (and therefore its density made larger). In addition, the safety block at its full-in position is closer to the inner subassembly plate than was modeled in the benchmark. These changes have been made to HEU-MET-FAST-086 Case 4 in order to estimate the effect on $\kappa$ eff and on the neutron flux spectrum. Using smaller separation, a smaller safety block, and a larger glory hole caused keff to increase by 453 ± 1 pcm from the benchmark. The latest nuclear data, ENDF/B-VIII.0, have also been used, causing $\kappa$ eff to increase another 37 ± 1 pcm. Flux spectra were compared in a modeled fission foil (near the center of Godiva-IV in the glory hole) and at three external (point) detectors. Within the fission foil, using ENDF/B-VIII.0 induced changes in the flux spectrum similar in size to the changes due to using smaller separation, a smaller safety block, and a larger glory hole. At the detectors, using ENDF/B- VIII.0 induced changes in the flux spectrum much larger than those due to changing the model. In other words, the corrections to the benchmark model cause a large increase in $\kappa$ eff , but the changes to the neutron flux spectrum are small compared to those caused by using the latest nuclear data. This study presents a preview of results expected during the reevaluation of the Godiva IV benchmark, but it is not a substitute for the full reevaluation.A note of errata prepended to the Godiva-IV delayed-critical benchmark (HEU-MET-FAST- 086) identifies two corrections to be made to the model: The glory hole in the spindle should be made larger, and the height of the safety block should be made smaller (and therefore its density made larger). In addition, the safety block at its full-in position is closer to the inner subassembly plate than was modeled in the benchmark. These changes have been made to HEU-MET-FAST-086 Case 4 in order to estimate the effect on $\kappa$ eff and on the neutron flux spectrum. Using smaller separation, a smaller safety block, and a larger glory hole caused $\kappa$ eff to increase by 453 ± 1 pcm from the benchmark. The latest nuclear data, ENDF/B-VIII.0, have also been used, causing $\kappa$ eff to increase another 37 ± 1 pcm. Flux spectra were compared in a modeled fission foil (near the center of Godiva-IV in the glory hole) and at three external (point) detectors. Within the fission foil, using ENDF/B-VIII.0 induced changes in the flux spectrum similar in size to the changes due to using smaller separation, a smaller safety block, and a larger glory hole. At the detectors, using ENDF/B- VIII.0 induced changes in the flux spectrum much larger than those due to changing the model. In other words, the corrections to the benchmark model cause a large increase in $\kappa$ eff , but the changes to the neutron flux spectrum are small compared to those caused by using the latest nuclear data. This study presents a preview of results expected during the reevaluation of the Godiva IV benchmark, but it is not a substitute for the full reevaluation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Star Equation of State in Light of GW190814

The observation of gravitational waves from an asymmetric binary opens the possibility for heavy neutron stars, but these pose challenges to models of the neutron star equation of state. Here, we construct heavy neutron stars by introducing nontrivial structure in the speed of sound sourced by deconfined QCD matter, which cannot be well recovered by spectral representations. Their moment of inertia, Love number, and quadrupole moment are very small, so a tenfold increase in sensitivity may be needed to test this possibility with gravitational waves, which is feasible with third generation detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗