Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOISE INTENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Initial utility experience with cluster of three Mod-2 wind turbine systems

This paper describes the initial utility experiences of operating three MOD-2s during the Engineering Acceptance Testing. Electrical quantities of bus voltage, phase currents and power are initially being recorded to evaluate impacts to customers on the 69-kV subtransmission line during synchronization and operation of one or more WTSs. To date, effects on the system have been essentially undetectable. Measurements of television signal strengths were taken at an existing television remote pickup and relay station at the WTS site. Potential TV signal interference problems from the WTSs have been avoided by replacing the remote pickups with microwave repeater links for the four TV channels received from Portland, Oregon. Preliminary measurements of audible and sub-audible noise levels indicate that the upwind rotor, tubular tower design of the MOD-2 does not have the pulsing high intensity infrasound problems experienced by the MOD-1 machine at Boone, North Carolina.

Seely, D. B.↗

Active Suppression Of Vibrations On Aircraft Structures

Method of active suppression of nonlinear and nonstationary vibrations developed to reduce sonic fatigue and interior noise in high-speed aircraft. Structure of aircraft exhibits periodic, chaotic, and random vibrations when forced by high-intensity sound from jet engines, shock waves, turbulence, and separated flows. Method of suppressing vibrations involves feedback control: Strain gauges or other sensors mounted in paths of propagation of vibrations on structure sense vibrations; outputs of sensors processed into control signal applied to actuator mounted on structure, inducing compensatory forces.

Maestrello, Lucio↗

Spectrally Resolved Synthetic Aperture Imaging Interferometer: Final Report of NASA Innovative Advanced Concepts - Phase 1 Study

The Spectrally Resolved Synthetic-Aperture Imaging Interferometer (SRSAII) is a system proposed to provide high-resolution and high-sensitivity measurements of astronomical objects. SRSAII uses long baseline interferometric methods to achieve the resolution and low-noise, high time-precision detection to achieve the sensitivity. The primary goal of the SRSAII study was to lay out a framework for using new optical physics technologies to directly resolve, both spatially and spectrally, the disk of an exoplanet. In addition to the ambitious goal of directly resolving an exoplanet, the SRSAII team also sought to identify science opportunities achievable with intermediate system configurations which may offer resolution significantly higher than the current state of the art, but insufficient for direct resolution of an exoplanetary disk. An operational SRSAII system can function with essentially arbitrarily large baselines, achieving correspondingly high angular resolution. The primary limitation occurs in the system sensitivity, which became the major technical focus for study. In this report, we compare the predicted performance (sensitivity in SNR (Signal-to-Noise Ratio) along with angular resolution) of three interferometric techniques: direct detection (also known as homodyne interferometry), multi-channel intensity interferometry (using the Hanbury Brown and Twiss effect), and multi-channel heterodyne interferometry (using an optical frequency comb as a local oscillator). Additionally, quantum-assisted interferometry is also explored as a prospective enhancement of established methods. This report presents a survey of the technologies that enable the SRSAII techniques - optical frequency combs, single photon detectors, and photonic integrated circuits. These technologies are the basis of methods critical to SRSAII's success: precision timing, length and frequency metrology, sensitive photodetection, fine-scale wavelength filtering, and dense multi-channel operation. Lastly, we give some notional performance metrics and propose some possible experimental observations.

High Resolultion↗

Orthogonal ion injection apparatus and process

An orthogonal ion injection apparatus and process are described in which ions are directly injected into an ion guide orthogonal to the ion guide axis through an inlet opening located on a side of the ion guide. The end of the heated capillary is placed inside the ion guide such that the ions are directly injected into DC and RF fields inside the ion guide, which efficiently confines ions inside the ion guide. Liquid droplets created by the ionization source that are carried through the capillary into the ion guide are removed from the ion guide by a strong directional gas flow through an inlet opening on the opposite side of the ion guide. Strong DC and RF fields divert ions into the ion guide. In-guide orthogonal injection yields a noise level that is a factor of 1.5 to 2 lower than conventional inline injection known in the art. Signal intensities for low m/z ions are greater compared to convention inline injection under the same processing conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas and liquid measurements in air-water bubbly flows

Local measurements of gas- and liquid-phase flow parameters are conducted in an air-water two-phase flow loop. The test section is a vertical pipe with an inner diameter of 50 mm and a height of 3.2 m. The measurements are performed at z/D = 10. The gas-phase measurements are performed using a four-sensor conductivity probe. The data taken from this probe are processed using a signal processing program to yield radial profiles of the void fraction, bubble velocity, and interfacial area concentration. The velocity measurements of the liquid-phase are performed using a state-of-the-art Particle Image Velocimetry (PIV) system. The raw PIV images are acquired using fluorescent particles and an optical filtration device. Image processing is used to remove noise in the raw PIV images. The statistical cross correlation is introduced to determine the axial velocity field and turbulence intensity of the liquid-phase. Measurements are currently being performed at z/D = 32 to provide a more complete data set. These data can be used for computational fluid dynamic model development and validation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Numerical and Physical Modeling of the Response of Resonator Liners to Intense Sound and Grazing Flow

Two significant advances have been made in the application of computational aeroacoustics methodology to acoustic liner technology. The first is that temperature effects for discrete sound are not the same as for broadband noise. For discrete sound, the normalized resistance appears to be insensitive to temperature except at high SPL. However, reactance is lower, significantly lower in absolute value, at high temperature. The second is the numerical investigation the acoustic performance of a liner by direct numerical simulation. Liner impedance is affected by the non-uniformity of the incident sound waves. This identifies the importance of pressure gradient. Preliminary design one and two-dimensional impedance models were developed to design sound absorbing liners in the presence of intense sound and grazing flow. The two-dimensional model offers the potential to empirically determine incident sound pressure face-plate distance from resonator orifices. This represents an important initial step in improving our understanding of how to effectively use the Dean Two-Microphone impedance measurement method.

Hersh, Alan S.↗

Aeroacoustics of Space Vehicles

While for airplanes the subject of aeroacoustics is associated with community noise, for space vehicles it is associated with vibro-acoustics and structural dynamics. Surface pressure fluctuations encountered during launch and travel through lower part of the atmosphere create intense vibro-acoustics environment for the payload, electronics, navigational equipment, and a large number of subsystems. All of these components have to be designed and tested for flight-certification. This presentation will cover all three major sources encountered in manned and unmanned space vehicles: launch acoustics, ascent acoustics and abort acoustics. Launch pads employ elaborate acoustic suppression systems to mitigate the ignition pressure waves and rocket plume generated noise during the early part of the liftoff. Recently we have used large microphone arrays to identify the noise sources during liftoff and found that the standard model by Eldred and Jones (NASA SP-8072) to be grossly inadequate. As the vehicle speeds up and reaches transonic speed in relatively denser part of the atmosphere, various shock waves and flow separation events create unsteady pressure fluctuations that can lead to high vibration environment, and occasional coupling with the structural modes, which may lead to buffet. Examples of wind tunnel tests and computational simulations to optimize the outer mold line to quantify and reduce the surface pressure fluctuations will be presented. Finally, a manned space vehicle needs to be designed for crew safety during malfunctioning of the primary rocket vehicle. This brings the subject of acoustic environment during abort. For NASAs Multi-Purpose Crew Vehicle (MPCV), abort will be performed by lighting rocket motors atop the crew module. The severe aeroacoustics environments during various abort scenarios were measured for the first time by using hot helium to simulate rocket plumes in the Ames unitary plan wind tunnels. Various considerations used for the helium simulation and the final confirmation from a flight test will be presented.

launch vehicle↗

Spectral Line Parameters Including Temperature Dependences of Self- and Air-Broadening in the 2 (left arrow) 0 Band of CO at 2.3 micrometers

Temperature dependences of pressure-broadened half-width and pressure-induced shift coefficients along with accurate positions and intensities have been determined for transitions in the 2<--0 band of C-12 O-16 from analyzing high-resolution and high signal-to-noise spectra recorded with two different Fourier transform spectrometers. A total of 28 spectra, 16 self-broadened and 12 air-broadened, recorded using high- purity (greater than or equal to 99.5% C-12-enriched) CO samples and CO diluted with dry air(research grade) at different temperatures and pressures, were analyzed simultaneously to maximize the accuracy of the retrieved parameters. The sample temperatures ranged from 150 to 298K and the total pressures varied between 5 and 700 Torr. A multispectrum nonlinear least squares spectrum fitting technique was used to adjust the rovibrational constants (G, B, D, etc.) and intensity parameters (including Herman-Wallis coefficients), rather than determining individual line positions and intensities. Self-and air-broadened Lorentz half-width coefficients, their temperature dependence exponents, self- and air-pressure-induced shift coefficients, their temperature dependences, self- and air-line mixing coefficients, their temperature dependences and speed dependence have been retrieved from the analysis. Speed-dependent line shapes with line mixing employing off-diagonal relaxation matrix element formalism were needed to minimize the fit residuals. This study presents a precise and complete set of spectral line parameters that consistently reproduce the spectrum of carbon monoxide over terrestrial atmospheric conditions.

Devi, V. Malathy↗

Jet noise source modification due to forward flight

The effects of forward flight on the turbulence characteristics of a jet in a co-flowing stream have been determined for a 2.22 inch circular jet in a 36 inch free jet wind tunnel. The nozzle exit velocity was 400 ft/sec, and the tunnel velocity was set at 0, 40, 120 and 200 ft/sec. Measurements of flow properties including mean velocity, turbulence intensity and spectra, convection velocity, integral length scale, and convected integral time scale were carried out using two linearized hot wires. Results were used to predict changes due to flight in the jet acoustic sources. The noise reductions for a cold jet with a velocity of 1000 ft/sec, due to the change in acoustic sources in flight, agreed well at all angles with measured noise reductions.

Larson, R. S.↗

Neural Posterior Estimation for Scalable and Accurate Inverse Parameter Inference in Li-Ion Batteries

Diagnosing the internal state of Li-ion batteries is critical for battery research, operation of real-world systems, and prognostic evaluation of remaining lifetime. By using physics-based models to perform probabilistic parameter estimation via Bayesian calibration, diagnostics can account for the uncertainty due to model fitness, data noise, and the observability of any given parameter. However, Bayesian calibration in Li-ion batteries using electrochemical data is computationally intensive even when using a fast surrogate in place of physics-based models, requiring many thousands of model evaluations. A fully amortized alternative is neural posterior estimation (NPE). NPE shifts the computational burden from the parameter estimation step to data generation and model training, reducing the parameter estimation time from minutes to milliseconds, enabling real-time applications. The present work shows that NPE can infer parameters equally or more accurately than Bayesian calibration, even if it leads to higher voltage reconstruction errors. We also demonstrate that the higher computational costs for data generation are tractable even in high-dimensional cases (ranging from 6 to 27 estimated parameters). The NPE method also offers several interpretability advantages over Bayesian calibration, such as local parameter sensitivity to specific regions of the voltage curve. The NPE method is demonstrated using an experimental fast charge dataset, with parameter estimates validated against measurements of loss of lithium inventory and loss of active material. The implementation is made available in a companion repository (https://github.com/NatLabRockies/BatFIT).

25 ENERGY STORAGE↗

Control and application of beam microbunching in high brightness linac-driven free electron lasers

Here, we review physical mechanisms and driving forces behind the microbunching instability in modern free-electron lasers. Laser heater and alternative methods to fight the instability are presented and evaluated. Advanced uses of the laser heater setup for temporal and spectral controls of the FEL and for intense THz production are discussed. A recent idea of using the microbunching instability for coherent generation of UV radiation is described. Noise suppression in relativistic beams is briefly reviewed.

47 OTHER INSTRUMENTATION↗

High-sensitivity electronic Stark spectrometer featuring a laser-driven light source

We report developmental details of a high-sensitivity Stark absorption spectrometer featuring a laser-driven light source. The light source exhibits intensity fluctuations of ~0.3% over timescales ranging from 1 min to 12 h, minimal drift (≤0.1%/h), and very little 1/f noise at frequencies greater than 200 Hz, which are comparable to or better than an arc-driven light source. Additional features of the spectrometer include balanced detection with multiplex sampling, which yielded lower noise in A, and constant wavelength or wavenumber (energy) spectral bandpass modes. We achieve noise amplitudes of ~7 × 10 –4 and ~6 × 10 –6 in measurements of single A and ΔA spectra (with 92 data points) taking ~7 and ~19 min, respectively.

47 OTHER INSTRUMENTATION↗

Astrophysics & cosmology from line intensity mapping vs galaxy surveys

Line intensity mapping (LIM) proposes to efficiently observe distant faint galaxies and map the matter density field at high redshift. Building upon the formalism in a companion paper, we first highlight the degeneracies between cosmology and astrophysics in LIM. We discuss what can be constrained from measurements of the mean intensity and redshift-space power spectra. With a sufficient spectral resolution, the large-scale redshift-space distortions of the 2-halo term can be measured, helping to break the degeneracy between bias and mean intensity. With a higher spectral resolution, measuring the small-scale redshift-space distortions disentangles the 1-halo and shot noise terms. Additionally, cross-correlations with external galaxy catalogs or lensing surveys further break degeneracies. We derive requirements for experiments similar to SPHEREx, HETDEX, CDIM, COMAP and CONCERTO. We then revisit the question of the optimality of the LIM observables, compared to galaxy detection, for astrophysics and cosmology. We use a matched filter to compute the luminosity detection threshold for individual sources. We show that LIM contains information about galaxies too faint to detect, in the high-noise or high-confusion regimes. We quantify the sparsity and clustering bias of the detected sources and compare them to LIM, showing in which cases LIM is a better tracer of the matter density. We extend previous work by answering these questions as a function of Fourier scale, including for the first time the effect of cosmic variance, pixel-to-pixel correlations, luminosity-dependent clustering bias and redshift-space distortions.

79 ASTRONOMY AND ASTROPHYSICS↗

Automated identification of retinal vessels using a multiscale directional contrast quantification (MDCQ) strategy

Purpose: A novel algorithm is presented to automatically identify the retinal vessels depicted in color fundus photographs. Methods: The proposed algorithm quantifies the contrast of each pixel in retinal images at multiple scales and fuses the resulting consequent contrast images in a progressive manner by leveraging their spatial difference and continuity. The multiscale strategy is to deal with the variety of retinal vessels in width, intensity, resolution, and orientation; and the progressive fusion is to combine consequent images and meanwhile avoid a sudden fusion of image noise and/or artifacts in space. To quantitatively assess the performance of the algorithm, we tested it on three publicly available databases, namely, DRIVE, STARE, and HRF. The agreement between the computer results and the manual delineation in these databases were quantified by computing their overlapping in both area and length (centerline). The measures include sensitivity, specificity, and accuracy. Results: For the DRIVE database, the sensitivities in identifying vessels in area and length were around 90% and 70%, respectively, the accuracy in pixel classification was around 99%, and the precisions in terms of both area and length were around 94%. For the STARE database, the sensitivities in identifying vessels were around 90% in area and 70% in length, and the accuracy in pixel classification was around 97%. For the HRF database, the sensitivities in identifying vessels were around 92% in area and 83% in length for the healthy subgroup, around 92% in area and 75% in length for the glaucomatous subgroup, around 91% in area and 73% in length for the diabetic retinopathy subgroup. For all three subgroups, the accuracy was around 98%. Conclusions: The experimental results demonstrate that the developed algorithm is capable of identifying retinal vessels depicted in color fundus photographs in a relatively reliable manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-I-58: Image Quality Comparisons of Different Motion Magnitudes and TR Values in MR-PET

Purpose: The aim of this work is to evaluate the accuracy and sensitivity of a respiratory-triggered MR-PET protocol in detecting four different sized lesions at two different magnitudes of motion, with two different TR values, using a novel PET-MR-CT compatible respiratory motion phantom. Methods: The eight-compartment torso phantom was setup adjacent to the motion stage, which moved four spherical compartments (28, 22, 17, 10 mm diameter) in two separate (1 and 2 cm) linear motion profiles, simulating a 3.5 second respiratory cycle. Scans were acquired on a 3T MR-PET system (Biograph mMR; Siemens Medical Solutions, Germany). MR measurements were taken with: 1) Respiratory-triggered T2-weighted turbo spin echo (BLADE) sequence in coronal orientation, and 2) Real-time balanced steady-state gradient echo sequence (TrueFISP) in coronal and sagittal planes. PET was acquired simultaneously with MR. Sphere geometries and motion profiles were measured and compared with ground truths for T2 BLADE-TSE acquisitions and real time TrueFISP images. PET quantification and geometry measurements were taken using standardized uptake values, voxel intensity plots and were compared with known values, and examined alongside MR-based attenuation maps. Contrast and signal-to-noise ratios were also compared for each of the acquisitions as functions of motion range and TR. Results: Comparison of lesion diameters indicate the respiratory triggered T2 BLADE-TSE was able to maintain geometry within −2 mm for 1 cm motion for both TR values, and within −3.1 mm for TR = 2000 ms at 2 cm motion. Sphere measurements in respiratory triggered PET images were accurate within +/− 5 mm for both ranges of motion for 28, 22, and 17 mm diameter spheres. Conclusion: Hybrid MR-PET systems show promise in imaging lung cancer in non-compliant patients, with their ability to acquire both modalities simultaneously. However, MR-based attenuation maps are still susceptible to motion derived artifacts and pose the potential to affect PET accuracy.

60 APPLIED LIFE SCIENCES↗

CHANG-ES. VII. Magnetic outflows from the Virgo cluster galaxy NGC 4388

We investigate the effects of ram pressure on the ordered magnetic field of a galaxy hosting a radio halo and strong nuclear outflows. New radio images in total and polarized intensity of the edge-on Virgo galaxy NGC 4388 were obtained within the CHANG-ES EVLA project. The unprecedented noise level reached allows us to detect striking new features of the ordered magnetic field. The nuclear outflow extends far into the halo to about 5 kpc from the center and is spatially correlated with the Hα and X-ray emission. For the first time, the southern outflow is detected. Above and below both spiral arms we find extended blobs of polarized emission with an ordered field oriented perpendicular to the disk. The synchrotron lifetime of the cosmic-ray electrons (CREs) in these regions yields a mean outflow velocity of 270±70 km s{sup −1}, in agreement with a galactic wind scenario. The observed symmetry of the polarized halo features in NGC 4388 excludes a compression of the halo gas by the ram pressure of the intracluster medium (ICM). The assumption of equilibrium between the halo pressure and the ICM ram pressure yields an estimate of the ICM density that is consistent with both the ICM density derived from X-ray observations and the recent Planck Sunyaev–Zel’dovich measurements. The detection of a faint radio halo around cluster galaxies could thus be used for an estimate of ICM ram pressure.

79 ASTRONOMY AND ASTROPHYSICS↗

A theory for chorus generation by energetic electrons during substorms

Previous observations during magnetospheric substorms reveal the existence of relatively narrow band electromagnetic emissions occurring slightly above and below one half of the electron cyclotron frequency in the equatorial magnetosphere beyond the plasmapause. Between these two bands of emission there exists a gap of much lower emission intensity. In this paper an interpretation is presented for these chorus observations wherein the lower emission band is represented by whistler noise and the upper emission band is described by the lowest harmonic of the ordinary mode. These emissions are assumed to be locally generated at the observation point. Both emission bands are excited by power law-distributed energetic electrons with a variable spectral index and a weak loss cone feature. The form of these energetic electrons is similar to the forms observed simultaneously with the chorus emissions. The calculated growth rates show a frequency distribution similar to that of the measured emissions. In addition, the same energetic electron distribution can also produce the electrostatic gyroharmonic emissions often seen by observers in conjunction with chorus emissions during substorms.

Curtis, S. A.↗

Voyager 2 plasma wave observations at Saturn

The first inbound Voyager 2 crossing of Saturn's bow shock (at 31.7 Saturn radii near local noon) and the last outbound crossing (at 87.4 Saturn radii near local dawn) had similar plasma wave signatures. However, many other aspects of the plasma wave measurements differed considerably during the inbound and outbound passes, suggesting the presence of effects associated with significant north-south or noon-dawn asymmetries, or temporal variations. Within Saturn's magnetosphere, the plasma wave instrument detected electron plasma oscillations, upper hybrid resonance emissions, half-gyrofrequency harmonics, hiss and chorus, narrowband electromagnetic emissions and broadband Saturn radio noise, and noise bursts with characteristics of static. At the ring plane crossing, the plasma wave instrument also detected a large number of intense impulses that were interpreted in terms of ring particle impacts on Voyager 2.

Scarf, F. L.↗