Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

A consistent path for phase determination based on transmission electron microscopy techniques and supporting simulations

Here this work addresses aspects for the analysis of industrial relevant materials via transmission electron microscopy (TEM). The complex phase chemistry and structural diversity of these materials require several characterization techniques to be employed simultaneously; unfortunately, different characterization techniques often lack connection to yield a complete and consistent picture. This paper describes a continuous path, starting with the acquisition of 3D diffraction data – alongside classical high-resolution imaging techniques – and linking the structural characterization of hard metal industrial samples with energy-loss fine-structure simulations, quantitative electron energy-loss (EEL) and energy-dispersive X-ray (EDX) spectroscopy. Thereby, the compositional analysis of a MAX phase indicated an offset of the hydrogenic, theoretical sensitivity factors, originating from poorly-adjusted screening factors. In a next step, these results were matched against quantitative compositions and parameters obtained from X-ray spectroscopy data, carried out synchronously with EELS.

36 MATERIALS SCIENCE↗

Dynamic behavior of nanoscale liquids in graphene liquid cells revealed by in situ transmission electron microscopy

Recent advances in graphene liquid cells for in situ transmission electron microscopy (TEM) have opened many opportunities for the study of materials transformations and chemical reactions in liquids with high spatial resolution. However, the behavior of thin liquids encapsulated in a graphene liquid cell has not been fully understood. Here, we report real time TEM imaging of the nanoscale dynamic behavior of liquids in graphene nanocapillaries. Our observations reveal that the interfaces between liquid and gas bubble can fluctuate, leading to the generation of liquid nanodroplets near the interfaces. Liquid nanodroplets often show irregular shape with dynamic changes of their configuration under the electron beam. We consider that the dynamic motion of liquid-gas interfaces might be introduced by the electrostatic energy from transiently charged interfaces. We find that improving the wettability of graphene liquid cells by ultraviolet-ozone treatment can significantly modify the dynamic motion of the encapsulated liquids. Our study provides valuable information of the interactions between liquid and graphene under the electron beam, and it also offers key insights on the nanoscale fluid dynamics in confined spaces.

36 MATERIALS SCIENCE↗

New approach to electron microscopy imaging of gel nanocomposites in situ

We present that characterization of Au-nanocomposites is routinely done with scattering techniques where the structure and ordering of nanoparticles can be analyzed. Imaging of Poloxamer gel-based Au-nanocomposites is usually limited to cryo-TEM imaging of cryo-microtomed thin sections of the specimen. While this approach is applicable for imaging of the individual nanoparticles and gauging their size distribution, it requires altering the state of the specimen and is prone to artifacts associated with preparation protocols. Use of Scanning Transmission Electron Microscopy (S/TEM) with fluid cell in situ provides an opportunity to analysis of these complex materials in their hydrated state with nanometer resolution, yet dispensing dense gel-based samples onto electron-transparent substrates remains challenging. Here, we show that Poloxamer gel-based Au nanocomposites exhibiting thermoreversible behavior can be imaged in a fully hydrated state using a commercially available fluid cell holder, and we describe a specimen preparation method for depositing femtoliter amounts of gel-based nanocomposites directly onto the 50 nm-thick SiN window membranes. Ultimately, fluid cell S/TEM in situ imaging approach offers a pathway to visualization of individual nanoparticles within a thick gel media while maintaining the hydrated state of the carrier polymeric matrix.

36 MATERIALS SCIENCE↗

Correlating dislocation structures to basal and prismatic slip bands near grain boundaries in tensile-tested Mg–4Al using a multiscale electron microscopy approach

Dislocation structures where basal and prismatic slip bands meet grain boundaries in tensile-tested Mg with 4 wt% Al (Mg–4Al) were studied using a multiscale electron microscopy approach to explore the assumptions made for the dislocation pileup theory: a) slip bands consist of dislocation arrays piling up near grain boundaries, and b) stress concentration in the adjacent grain is solely caused by dislocation pileup. After post-testing electron backscatter diffraction (EBSD) scans, focused-ion-beam (FIB) lift-out specimens were prepared from regions of interest so that the specimen plane is parallel to the bulk sample surface to allow for direct correlation between mesoscale and microscale characterization. High dislocation density and the dislocation arrays in the slip bands corroborated with the first assumption. Evidence of plastic deformation in all grains, however, showed that the second assumption was false. Additionally, dislocation structures including crystal rotation boundaries and dislocations dissociating to the basal plane provide additional stress relief mechanisms near grain boundaries that are not accounted for in many crystal plasticity models, which requires auxiliary models to more accurately predict the stress and strain distribution in a microstructure.

36 MATERIALS SCIENCE↗

Effects of elevated temperature exposure on the residual stress state and microstructure of PVD Cr coatings on SiC investigated via in situ X-ray diffraction and transmission electron microscopy

Pure Cr coatings are being considered as corrosion-resistant layers for SiC-SiC f composite fuel cladding in light water reactors. The residual stress state and interdiffusion behavior of Cr coatings deposited on SiC substrates using bipolar high-power impulse magnetron sputtering (B-HiPIMS) and direct current impulse magnetron sputtering (DCMS) were studied using in situ X-ray diffraction experiments at 300 °C, 700 °C, and 1200 °C. After elevated temperature exposure, evolution of the coating microstructure and coating/substrate interdiffusion was characterized by transmission electron microscopy. The compressive residual stress of the dense B-HiPIMS coating at room temperature was gradually relieved at 300 °C, while the stress transitioned to a tensile state at 700 °C. Grain growth of the Cr coating and a Cr–SiC interdiffusion layer consisting of newly formed Cr–C and Cr–Si phases were observed in the B-HiPIMS coating after exposure at 700 °C. The phases in the interdiffusion layer were identified to be Cr 7 C 3 , Cr 3 Si, and Cr 5 Si 3 C x experimentally and by thermodynamic predictions. For the DCMS coating, however, changes in residual stress and microstructure at the elevated temperatures were limited by the inherent porosity and inhomogeneous structure of the as-deposited coating. At 1200 °C, both coating types interacted rapidly with the underlying SiC substrate in the early stages of the experiment. The results from this study suggest that the characteristics of the Cr coatings do not significantly change at the reactor operating temperature of 300 °C, while changes in microstructure and stress state are expected in off-normal conditions of 700 °C and 1200 °C. Finally the results from this study suggest the B-HiPIMS coating is best-suited as a protective coating for SiC fuel cladding.

36 MATERIALS SCIENCE↗

Operando liquid cell electron microscopy of discharge and charge kinetics in lithium-oxygen batteries

Despite the promising future of lithium-oxygen (Li-O 2 ) battery in replacing conventional lithium ion battery for high-energy applications, the complicated reaction mechanisms determining the sluggish discharge-charge kinetics have not been fully understood. Here, utilizing in situ liquid transmission electron microscopy, the (electro) chemical fundamentals in a working Li-O 2 battery is explored. During discharge, the nucleation of Li 2 O 2 is observed at the carbon electrode/electrolyte interface, and the following growth process exhibits Li + diffusion-limited kinetics. Nucleation and growth of Li 2 O 2 are also observed within the electrolyte, where there is no direct contact with the carbon electrode indicating the existence of non-Faradaic disproportionation reaction of intermediate LiO 2 into Li 2 O 2 . The growth of Li 2 O 2 isolated in the electrolyte exhibits O 2 - diffusion-limited kinetics. Li 2 O 2 at the carbon electrode surface and isolated in the electrolyte are both active upon charging and gradually decomposed. For Li 2 O 2 particles rooted at the carbon electrode surface, the decomposition starts at the electrode/Li 2 O 2 interface indicating electron-conduction limited charge kinetics. For Li 2 O 2 isolated within the electrolyte, surprisingly, a side-to-side decomposition mode is identified indicating the non-Faradaic formation of dissolvable O 2 - , whose diffusion in the electrolyte controls the overall charge kinetics. In conclusion, this work reveals further details of underlying mechanisms in a working Li-O 2 battery and identifies various limiting factors controlling the discharge and charge processes.

25 ENERGY STORAGE↗

Magnetic force microscopy revealing long range molecule impact on magnetic tunnel junction based molecular spintronics devices

Magnetic force microscopy (MFM) vividly showed that organometallic molecules, when bridged between two ferromagnetic electrodes along the cross-shaped magnetic tunnel junction edges transformed the magnetic electrodes itself. Molecules impacted a large area of ferromagnetic leads around the junction at room temperature and complement the previous magnetic measurements showing molecule effect on pillar form magnetic tunnel junctions. This molecule induced changes in the magnetic electrodes impacted the transport of the magnetic tunnel junction and stabilized as much as seven orders smaller current at room temperature. We have discussed the current suppression phenomenon in the recent publication [Ref. Tyagi et al. Organic Electronics, 2019, Vol. 64, p 188]; however, we did not provide any direct evidence of molecule impact on ferromagnetic electrodes around molecule junction. Our MFM studies in this paper suggests that molecule effect was observable several μm away from the molecule-metal junctions. Furthermore, our study suggests that magnetic tunnel junction based molecular spintronics devices can be a gateway to a vast range of commercially viable and robust futuristic computer devices and highly correlated materials.

42 ENGINEERING↗

Scanning tunneling microscopy study of the antiferromagnetic topological insulator MnBi 2 Se 4

Topological insulators with intrinsic magnetic ordering such as MnBi 2 Se 4 have been predicted to host many exotic topological phenomena including dissipationless edge states and magnetoelectric effects. Here we use scanning tunneling microscopy to study the surface of MnBi 2 Se 4 epitaxial thin films. Large scale topographic images show steps between van der Waals layers and screw dislocations. While we find the Se-termination predominant on the surface, areas attributed to Bi-termination are found at the edges of small islands in as-grown films, or in larger areas upon removal of surface capping. Here, we compare these terminations through an analysis of step heights, atomic resolution images and tunneling spectroscopy. Tunneling spectra on the Se-termination reveals semiconducting behavior, with an apparent bandgap of >0.18eV that depends on the tip height. In contrast, tunneling spectra of the Bi-termination appears gapless, which could be an indication of dangling bond states on the surface. In both cases, a hexagonal 3.9Å lattice is observed that is consistent with the expected crystal structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluating the Taylor hardening model in polycrystalline Ti using high energy X-ray diffraction microscopy

High energy X-ray diffraction microscopy (HEDM) was employed to index nearly 1000 grains in a polycrystalline Ti specimen and characterize their deformation during an incremental tensile test. For each grain, the positions of its associated diffraction peaks were used for analyzing its evolving crystal orientation and stress tensor. The azimuthal breadth of each peak at different load steps was measured, allowing measurement of initial yielding and providing an estimate of the dislocation density evolution in each grain. Furthermore, the Taylor hardening model was evaluated grain by grain using the above data, indicating that it can represent hardening in most grains. The yield stress and the strain hardening coefficient for all grains were statistically analyzed with respect to grain orientation, grain size, slip systems, and the surrounding neighborhood to examine how the yield stress and hardening are correlated.

36 MATERIALS SCIENCE↗

Cryo-electron microscopy structure of a zinc uptake ABC transporter

Zn2+ is an essential micronutrient required for many biological processes. Microorganisms employ high-affinity Zn2+ ABC transporters to take up zinc from the environment when it is scarce, yet the mechanism of zinc uptake and its regulation remain poorly understood. Here, we report the cryo-electron microscopy structure of the Zn2+ ABC transporter complex ZnuB-ZnuC from Escherichia coli. It contains two ZnuB transport and two ZnuC regulatory subunits. The ZnuB homodimer is in an outward-facing, closed conformation with a large hydrophilic cavity at the dimer interface. Each ZnuC subunit contains an N-terminal nucleotide-binding domain and a C-terminal zinc-sensing domain (ZSD). Zn2+ binding to the ZSD locks the transporter in a closed state, whereas under low-Zn2+ conditions, the disorder of ZSD permits ATP-driven zinc uptake. Zn2+ ABC transporters are ubiquitously utilized by pathogenic bacteria to compete with hosts for Zn2+. These findings reveal potential therapeutic targets for disrupting Zn2+ homeostasis in antibiotic-resistant pathogens.

59 BASIC BIOLOGICAL SCIENCES↗

Scanning tunneling microscopy and spectroscopy of NiTe 2

Nickel ditelluride is an unusual member of the transition metal dichalcogenide family which has garnered interest due to potential valley spin-polarized surface states near the Fermi level and the presence of Dirac nodes in its electronic band structure. In this work, exfoliation of bulk nickel ditelluride is performed under ultra-high vacuum in order to generate a clean surface for scanning tunneling microscopy and spectroscopy at 4.8 K. Multiple features in the observed electronic density of states are observed in the vicinity of the Fermi level and compared to calculated band structures to elucidate their origins. Finally, our results are consistent with the presence of the spin-polarized surface states, yet indicate trivial states, which are close to the Fermi level, can interfere with their potential utility in spintronic applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Variable voltage electron microscopy: Toward atom-by-atom fabrication in 2D materials

The precisely focused electron beam (e-beam) in scanning transmission electron microscopy has been found to be a versatile tool for patterning matter on the atomic level and enabling atom-by-atom fabrication, however, beam-induced phenomena are known to be extremely sensitive to the e-beam energy and are closely correlated with the proximity of the knock-on threshold. Here we provide a method to control the energy transferred to the sample while facilitating much faster changes in accelerating voltages by maintaining a nearly constant temperature in the electron microscope lenses. We use this method to demonstrate in-situ nano-milling of a graphene film followed rapidly by “gentler” imaging at lower energy. Additionally, the insertion and controlled movement of silicon dopants in graphene is demonstrated by employing a different e-beam energy during each process. We believe the incorporation of variable e-beam energy will broaden the potential for atomic scale e-beam fabrication.

36 MATERIALS SCIENCE↗

UEMtomaton: A Source-Available Platform to Aid in Start-up of Ultrafast Electron Microscopy Labs

The steady rise in the number of ultrafast electron microscopy (UEM) labs, in addition to the opacity and lack of detailed descriptions of current approaches that would enable point-by-point construction, has created an opportunity for sharing common methods and instrumentation for (for example) automating data acquisition to assist in efficient lab start-up and to learn about common and robust protocols. In the spirit of open sharing of methods, we provide here a description of an entry-level method and user interface (UI) for automating UEM experiments, and we provide access to the source code and scripts (source-available) for ease of implementation or as a starting reference point for those entering or seeking to enter the field (https://github.com/CEMSFlannigan/UEMtomaton/releases/tag/v1.0). Core instrumentation and physical connections in the UEM lab at Minnesota are described. Interface communication schemes consisting of duo server-client pairs between critical components – the optical delay stage and the UEM digital camera – are presented, with emphasis placed on describing the logic and communications sequence designed to conduct automated series acquisitions. An application designed and programmed with C++/CLI as Windows Forms in Microsoft Visual Studio – dubbed UEMtomaton – is also presented. Key to the UI layout is centralization of the automation tasks and establishment of communication within the software rather than by interfacing with each individual workstation. It is our hope that this note provides useful insight for current and future UEM researchers, particularly with respect to generalizability and portability of the approach to emerging labs. Here, we note that while this basic, entry-level approach is certainly not the most sophisticated or comprehensive of those currently in use, we feel there is nevertheless value in clearly communicating a proven straightforward method to hopefully lower the barrier to entry into the field.

47 OTHER INSTRUMENTATION↗

A Quantitative Method for In Situ Pump-Beam Metrology in 4D Ultrafast Electron Microscopy

In this work, we report a method for measuring spot size and focusing conditions of the femtosecond (fs) excitation laser in situ at the specimen location in 4D ultrafast electron microscopy (UEM). The method makes use of threshold laser ablation behaviors of thin amorphous carbon membranes. For Gaussian beam profiles and for ablation threshold fluence values, we analytically derive expressions describing the relationship between ablated hole size and the actual laser spot size. Using these expressions, we developed experimental procedures for characterizing the shape and spot size of the pump beam at the specimen. We demonstrate the viability of the approach for incident excitation wavelengths of 343 nm and 515 nm, thus illustrating the applicability of the method to a range of optical wavelengths without modification. Further, we show that by measuring ablated hole size as a function of focusing condition, a full metrological characterization of the Gaussian beam propagation properties can be performed. Finally, we find good agreement for spot sizes determined with this method and with those determined by extrapolation from measurements taken outside the microscope column. Overall, this method is a simple, cost-effective means for accurate and precise determination of key pump-beam parameters in situ at the specimen location in UEM experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reconstructing the exit wave of 2D materials in high-resolution transmission electron microscopy using machine learning

Reconstruction of the exit wave function is an important route to interpreting high-resolution transmission electron microscopy (HRTEM) images. Here we demonstrate that convolutional neural networks can be used to reconstruct the exit wave from a short focal series of HRTEM images, with a fidelity comparable to conventional exit wave reconstruction. We use a fully convolutional neural network based on the U-Net architecture, and demonstrate that we can train it on simulated exit waves and simulated HRTEM images of graphene-supported molybdenum disulphide (an industrial desulfurization catalyst). We then apply the trained network to analyse experimentally obtained images from similar samples, and obtain exit waves that clearly show the atomically resolved structure of both the MoS 2 nanoparticles and the graphene support. We also show that it is possible to successfully train the neural networks to reconstruct exit waves for 3400 different two-dimensional materials taken from the Computational 2D Materials Database of known and proposed two-dimensional materials.

2D materials↗

Circular dichroism in hard X-ray photoelectron diffraction observed by time-of-flight momentum microscopy

X-ray photoelectron diffraction (XPD) is a powerful technique that yields detailed structural information of solids and thin films that complements electronic structure measurements. Among the strongholds of XPD we can identify dopant sites, track structural phase transitions, and perform holographic reconstruction. High-resolution imaging of k ll -distributions (momentum microscopy) presents a new approach to core-level photoemission. It yields full-field k x -k y XPD patterns with unprecedented acquisition speed and richness in details. Here, we show that beyond the pure diffraction information, XPD patterns exhibit pronounced circular dichroism in the angular distribution (CDAD) with asymmetries up to 80%, alongside with rapid variations on a small k ll -scale (0.1 Å -1 ). Measurements with circularly-polarized hard X-rays (hν = 6 keV) for a number of core levels, including Si, Ge, Mo and W, prove that core-level CDAD is a general phenomenon that is independent of atomic number. The fine structure in CDAD is more pronounced compared to the corresponding intensity patterns. Additionally, they obey the same symmetry rules as found for atomic and molecular species, and valence bands. Further, the CD is antisymmetric with respect to the mirror planes of the crystal, whose signatures are sharp zero lines. Calculations using both the Bloch-wave approach and one-step photoemission reveal the origin of the fine structure that represents the signature of Kikuchi diffraction. To disentangle the roles of photoexcitation and diffraction, XPD has been implemented into the Munich SPRKKR package to unify the one-step model of photoemission and multiple scattering theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Morphotype-resolved characterization of microalgal communities in a nutrient recovery process with ARTiMiS flow imaging microscopy

Microalgae-driven nutrient recovery represents a promising technology for phosphorus removal from wastewater while simultaneously generating biomass that can be valorized to offset treatment costs. As full-scale processes come online, system parameters including biomass composition must be carefully monitored to optimize performance and prevent culture crashes. In this study, flow imaging microscopy (FIM) was leveraged to characterize microalgal community composition in near real-time at a full-scale municipal wastewater treatment plant (WWTP) in Wisconsin, USA, and population and morphotype dynamics were examined to identify relationships between water chemistry, biomass composition, and system performance. Two FIM technologies, FlowCam and ARTiMiS, were evaluated as monitoring tools. ARTiMiS provided a more accurate estimate of total system biomass, and estimates derived from particle area as a proxy for biovolume yielded better approximations than particle counts. Deep learning classification models trained on annotated image libraries demonstrated equivalent performance between FlowCam and ARTiMiS, and convolutional neural network (CNN) classifiers proved significantly more accurate when compared to feature table-based dense neural network (DNN) models. Across a two-year study period, Scenedesmus spp. appeared most important for phosphorus removal, and were negatively impacted by elevated temperatures and increase in nitrite/nitrate concentrations. Chlorella and Monoraphidium also played an important role in phosphorus removal. For both Scenedesmus and Chlorella, smaller morphological types were more often associated with better system performance, whereas larger morphotypes likely associated with stress response(s) correlated with poor phosphorus recovery rates. Furthermore, these results demonstrate the potential of FIM as a critical technology for high-resolution characterization of industrial microalgal processes.

59 BASIC BIOLOGICAL SCIENCES↗

Nanoscopic lipid domains determined by microscopy and neutron scattering

Biological membranes are highly complex supramolecular assemblies, which play central roles in biology. However, their complexity makes them challenging to study their nanoscale structures. To overcome this challenge, model membranes assembled using reduced sets of membrane-associated biomolecules have been found to be both excellent and tractable proxies for biological membranes. Due to their relative simplicity, they have been studied using a range of biophysical characterization techniques. Here, in this review article, we will briefly detail the use of fluorescence and electron microscopies, and X-ray and neutron scattering techniques used over the past few decades to study the nanostructure of biological membranes.

59 BASIC BIOLOGICAL SCIENCES↗