Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Wind Energy Instrumentation Development Roadmap

The current instrumentation for observing the complex flow fields in and around wind plants struggles to match the fidelity of existing simulation tools. As a result, these measurement limitations create a hurdle for validating and assessing the quality of the wind plant numerical models. This roadmap for instrumentation development recommendations was created to offer guidance on narrowing the gap between measurement and simulation fidelity. A process was established to identify where gaps in instrumentation exist for wind energy test campaigns by analyzing the capabilities of instrumentation for capturing the various important phenomena at the necessary resolution for both the science goal and validation objectives. To this end, a multi-disciplinary team of experts on instrumentation, wind energy, and atmospheric science was assembled to identify these significant instrumentation needs. A recommendation for instrumentation to be developed is provided, and the framework developed through this process is expected to be useful to the design of future test campaigns. The mapping tools developed for this process will be distributed as part of a future International Energy Agency Wind Technology Collaboration Program task on instrumentation development.

17 WIND ENERGY↗

A sound horizon-free measurement of H 0 in DESI 2024

The physical size of the sound horizon at recombination is a powerful source of information for early-time measurements of the Hubble constant H 0 , and many proposed solutions to the Hubble tension therefore involve modifications to this scale. In light of this, there has been growing interest in measuring H 0 independently of the sound horizon. We present the first such measurement to use data from the Dark Energy Spectroscopic Instrument (DESI), jointly analyzing the full-shape galaxy power spectra of DESI luminous red galaxies, emission line galaxies, quasars, and the bright galaxy sample, in a total of six redshift bins. Information from the sound horizon scale is removed from our constraints via a rescaling procedure at the power spectrum level, with our sound horizon-marginalized measurement being driven instead primarily by the matter-radiation equality scale. This measurement is then combined with additional sound horizon-free information from Planck+ACT CMB lensing, uncalibrated type Ia supernovae, and the DESI Lyman-α forest. We agnostically combine with the DESY5, Pantheon+, and Union3 supernova datasets, with our tightest respective constraints being H 0 = 66.7 +1.7 -1.9 , 67.9 +1.9 -2.1 , and 67.8 +2.0 -2.2 km s -1 Mpc -1 . This corresponds to a sub-3% sound horizon-free constraint of the Hubble constant, and is the most precise measurement of its kind to date. Even without including information from the sound horizon, our measurement is still in 2.2-3.0σ tension with SH0ES. Additionally, the consistency between our result and other measurements that do rely on the sound horizon scale provides no evidence for new early-Universe physics (e.g. early dark energy). Future DESI data releases will allow unprecedented measurements of H 0 and place strong constraints on models that use beyond-ΛCDM physics to ameliorate the Hubble tension.

79 ASTRONOMY AND ASTROPHYSICS↗

TEAMER: Electrically Engaged Undulation (EEL) System

The Electrically Engaged UnduLation (EEL) system is a buoyancy-driven submersible device for powering oceanographic instruments. Physically, EEL is a slender body whose flexible spine is made up of energy units interconnected by uniaxial hinges. Each unit consists of a pair of piezoelectric elements that converts the bending stress into electrical current to a battery charging circuit. An outer plastic skin forms a seal against water and allows for flexibility at hinge locations. At the top is a bluff body with electronics that holds a ballast for buoyancy adjustment. The bluff body is also responsible for creating fluid instabilities in its wake. When gliding through the water (mode 2), the spine will flex in response to the alternating vortices that shed from the head. This "lock-in" phenomenon occurs when the frequency at which vortices shed resonates with the EEL natural frequency, during which the efficient gaits were found in species of sea snake, eels, and fish. For active propulsion, a single motor can be placed at the first segment and provide the oscillatory input for propulsion similar to a dolphin's kick. Such anguilliform swimming is both efficient and nearly silent compared to a spinning propeller. Ultimately, mimicking bio-locomotion provides a viable path to a drag-reduced, self-propelled energy harvesting system for ocean monitoring.

16 TIDAL AND WAVE POWER↗

Evaluation of ARM tethered-balloon system instrumentation for supercooled liquid water and distributed temperature sensing in mixed-phase Arctic clouds

A tethered-balloon system (TBS) has been developed and is being operated by Sandia National Laboratories (SNL) on behalf of the U.S. Department of Energy's (DOE) Atmospheric Radiation Measurement (ARM) User Facility in order to collect in situ atmospheric measurements within mixed-phase Arctic clouds. Periodic tethered-balloon flights have been conducted since 2015 within restricted airspace at ARM's Advanced Mobile Facility 3 (AMF3) in Oliktok Point, Alaska, as part of the AALCO (Aerial Assessment of Liquid in Clouds at Oliktok), ERASMUS (Evaluation of Routine Atmospheric Sounding Measurements using Unmanned Systems), and POPEYE (Profiling at Oliktok Point to Enhance YOPP Experiments) field campaigns. The tethered-balloon system uses helium-filled 34 m 3 helikites and 79 and 104 m 3 aerostats to suspend instrumentation that is used to measure aerosol particle size distributions, temperature, horizontal wind, pressure, relative humidity, turbulence, and cloud particle properties and to calibrate ground-based remote sensing instruments. Supercooled liquid water content (SLWC) sondes using the vibrating-wire principle, developed by Anasphere Inc., were operated at Oliktok Point at multiple altitudes on the TBS within mixed-hase clouds for over 200 h. Sonde-collected SLWC data were compared with liquid water content derived from a microwave radiometer, Ka-band ARM zenith radar, and ceilometer at the AMF3, as well as liquid water content derived from AMF3 radiosonde flights. The in situ data collected by the Anasphere sensors were also compared with data collected simultaneously by an alternative SLWC sensor developed at the University of Reading, UK; both vibrating-wire instruments were typically observed to shed their ice quickly upon exiting the cloud or reaching maximum ice loading. Temperature sensing measurements distributed with fiber optic tethered balloons were also compared with AMF3 radiosonde temperature measurements. Combined, the results indicate that TBS-distributed temperature sensing and supercooled liquid water measurements are in reasonably good agreement with remote sensing and radiosonde-based measurements of both properties. From these measurements and sensor evaluations, tethered-balloon flights are shown to offer an effective method of collecting data to inform and constrain numerical models, calibrate and validate remote sensing instruments, and characterize the flight environment of unmanned aircraft, circumventing the difficulties of in-cloud unmanned aircraft flights such as limited flight time and in-flight icing.

47 OTHER INSTRUMENTATION↗

Product ion distributions using H 3 O + proton-transfer-reaction time-of-flight mass spectrometry (PTR-ToF-MS): mechanisms, transmission effects, and instrument-to-instrument variability

Abstract. Proton-transfer-reaction mass spectrometry (PTR-MS) using hydronium ion (H3O+) ionization is widely used for the measurement of volatile organic compounds (VOCs) both indoors and outdoors. H3O+ ionization, as well as the associated chemistry in an ion–molecule reactor, is known to generate product ion distributions (PIDs) that include other product ions besides the proton-transfer product. We present a method, using gas-chromatography pre-separation, for quantifying PIDs from PTR-MS measurements of nearly 100 VOCs of different functional types including alcohols, ketones, aldehydes, acids, aromatics, organohalides, and alkenes. We characterize instrument configuration effects on PIDs and find that reactor reduced electric field strength (E/N), ion optic voltage gradients, and quadrupole settings have the strongest impact on measured PIDs. Through an interlaboratory comparison of PIDs measured from calibration cylinders, we characterized the variability of PID production from the same model of PTR-MS across seven participating laboratories. Product ion variability was generally smaller (e.g., < 20 %) for ions with larger contributions to the PIDs (e.g., > 0.30) but less predictable for product ions formed through O2+ and NO+ reactions. We present a publicly available library of H3O+ PTR-MS PIDs that will be updated periodically with user-provided data for the continued investigation into instrument-to-instrument variability of PIDs.

Link, Michael F. (ORCID:0000000218412455)↗

An improved Method for Determining Transient Fuel Dilution of Oil in an Internal-Combustion Engine Using Laser-Induced Florescence and Multivariate Least Square Calibration

An optical diagnostic, based on laser-induced fluorescence (LIF), has been developed for on-engine measurements of real-time fuel dilution of engine oil or fuel in oil (FIO). Fuel dilution of oil is broadly relevant to advancing engine technology including durability, calibration, and catalyst-system management, and believed to promote destructive stochastic pre-ignition (SPI) during high-load engine operations. While standard (e.g., ASTM D3524-90) methods are not capable of real-time transient measurements, the LIF technique resolves transient dilution on the minutes time scale. We have expanded on our original FIO instrument development by introducing an improved analysis based on multivariate least square chemometrics analysis. The measurement uses a fuel dye (180–1300 parts per million, by mass) and monitors for its presence in the oil using 532 nm excitation and LIF. While the original FIO instrument utilized a two-color ratio method for analysis, the improved chemometric analysis uses the fully resolved LIF dye spectra to provide better predictive FIO accuracy (>92%) over a wide FIO range (1.5–14%) typical of engine application. We also investigate the effect of oil temperature on the LIF signal. Limited engine applications for demonstrating and validating the improved FIO instrument are shown, and the related data used to quantify practical detection limit and sensitivity. The improved analysis is insensitive to laser power fluctuation and change in detector integration time, providing an excellent FIO sensitivity (1–2%) and detection limit (0.01 %FIO) over a wide range of loads and injection timings, illustrating this updated approach to be a promising tool for advancing engine technology.

42 ENGINEERING↗

Redox potential in Typha-dominated tidal brackish marsh, PIE LTER, Plum Island Sound, MA, June–December 2022

This dataset includes soil redox potential measurements collected at multiple depths within a tidal brackish wetland in the upper estuary of the Plum Island Ecosystems Long-Term Ecological Research site (PIE LTER), Plum Island Sound, Newbury, Massachusetts. Measurements were taken to evaluate temporal variation in redox potential in relation to hydrological events at three replicate locations. Data were recorded every 5 minutes using a Campbell Scientific Volt116 connected to a CR6 datalogger with SWAP instrument redox probes (ORP-30-4-B) and reference electrodes. Measurements were made at the AmeriFlux site US-PLo at four soil depths (5, 10, 15, and 30 cm). The file redox_soiltemp_2022.csv contains temperature-corrected redox values and soil temperature following Silva-Machado et al. (2024). Metadata files redox_soiltemp_dd.csv and redox_soiltemp_flmd.csv provide detailed descriptions of variables and site locations.

54 ENVIRONMENTAL SCIENCES↗

Redox potential in Typha-dominated tidal brackish marsh, PIE LTER, Plum Island Sound, MA, 2023

This dataset includes soil redox potential measurements collected at multiple depths within a tidal brackish wetland in the upper estuary of the Plum Island Ecosystems Long-Term Ecological Research site (PIE LTER), Plum Island Sound, Newbury, Massachusetts (MA). Measurements were taken to evaluate temporal variation in redox potential in relation to hydrological events at three replicate locations. Data were recorded every 5 minutes using a Campbell Scientific Volt116 connected to a CR6 datalogger with SWAP instrument redox probes (ORP-30-4-B) and reference electrodes. Measurements were made at the AmeriFlux site US-PLo at four soil depths (5, 10, 15, and 30 cm). The file redox_soiltemp_2023.csv contains temperature-corrected redox values and soil temperature following Silva-Machado et al. (2024). Metadata files redox_soiltemp_dd.csv and redox_soiltemp_2023_flmd.csv provide detailed descriptions of variables and site locations.

54 ENVIRONMENTAL SCIENCES↗

Nephelometer Aboard Aircraft Instrument Handbook

The TSI model 3563 integrating nephelometer instrument is pictured in section 4.0, and more information can be found on the manufacturer’s website. This model was used on the Gulfstream-159 (G-1) aircraft operated by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF) up until 2019. The same instrument will be deployed on the new aircraft that will replace the G-1.

47 OTHER INSTRUMENTATION↗

Automated Generation of Weather and Climate Analysis Products

Wind roses are an important part to site operations as they depict the wind speed and direction percentage over a time period. In this project, I automated the production of wind roses for SRS meteorological towers. I developed a script to sequence through the dataset by period and create a wind rose for each of those period sets. Graphics were generated for every 4-hour period of the day, for each of the 4 heights of the instruments, for every half of each month. A 10-year climatological period consisted of wind speed and directions measurements at 15-minute intervals. We used the years 2014-2024 as the wind instruments on the tower were upgraded to sonic anemometers in early 2014. I then compared these wind roses to those from a previous study done in 2003 to analyze the differences and similarities in the wind patterns. The wind roses are also used to understand environmental transport conditions at SRS. When comparing the different heights of the anemometers to the 2003 report, there is a similarity in the fact that the direction is relatively the same across the levels, with the wind speeds increasing as you get higher in the air. When comparing the season of our graphs against the 2003 report, we noticed that the winter and summer months appear to have very similar wind directions. However, in the spring we noticed that there were more southerly winds compared to the 2003 report which had more westerly winds. Finally, in the fall months, we noticed that there was a higher percentage of northeasterly winds, while the 2003 report showed more southeasterly winds. We can use these summaries to estimate the directional dependence of dose that the surrounding areas receive throughout the year according to time of day.

47 OTHER INSTRUMENTATION↗

Measuring the Mean Free Path of H i Ionizing Photons at 3.2 ≤ z ≤ 4.6 with DESI Y1 Quasars

The mean free path of ionizing photons in the intergalactic medium (IGM; λ $^{912}_{mpf}$ ) is a crucial quantity in modeling the ionization state of the IGM and the extragalactic ultraviolet background, and it is widely used in hydrodynamical simulations of galaxies and reionization. We construct the largest quasar spectrum data set to date—12,595 signal-to-noise ratio > 3 spectra—using the Y1 observations of the Dark Energy Spectroscopic Instrument, to make the most precise model-independent measurement of the mean free path at 3.2 ≤ z ≤ 4.6. By stacking the spectra in 17 redshift bins and modeling the Lyman-continuum profile, we get a redshift evolution λ $^{912}_{mpf}$ ∝ ( 1 + z ) − 4.27 at 2 ≤ z ≤ 5, which is much shallower than the previous estimate, λ $^{912}_{mpf}$ ∝ ( 1 + z ) − 5.4 . We then explore the sources of systematic bias, including the choice of the intrinsic quasar continuum, the consideration of Lyman-series opacity and Lyman-limit opacity evolution, and the definition of λ $^{912}_{mpf}$ . Combining our results with estimates of λ $^{912}_{mpf}$ at higher redshifts, we conclude at high confidence that the evolution in λ $^{912}_{mpf}$ steepens at z ≈ 5. We interpret this inflection as the transition from the end of H i reionization to a fully ionized plasma that characterizes the IGM of the past ∼10 billion yr.

79 ASTRONOMY AND ASTROPHYSICS↗

Observations of compact sources in galaxy clusters using MUSTANG2

Compact sources can cause scatter in the scaling relationships between the amplitude of the thermal Sunyaev–Zel’dovich Effect (tSZE) in galaxy clusters and cluster mass. Estimates of the importance of this scatter vary – largely due to limited data on sources in clusters at the frequencies at which tSZE cluster surveys operate. In this paper, we present 90 GHz compact source measurements from a sample of 30 clusters observed using the MUSTANG2 instrument on the Green Bank Telescope. We present simulations of how a source’s flux density, spectral index, and angular separation from the cluster’s centre affect the measured tSZE in clusters detected by the Atacama Cosmology Telescope (ACT). By comparing the MUSTANG2 measurements with these simulations we calibrate an empirical relationship between 1.4 GHz flux densities from radio surveys and source contamination in ACT tSZE measurements. We find 3 per cent of the ACT clusters have more than a 20 per cent decrease in Compton-y but another 3 per cent have a 10 per cent increase in the Compton-y due to the matched filters used to find clusters. As sources affect the measured tSZE signal and hence the likelihood that a cluster will be detected, testing the level of source contamination in the tSZE signal using a tSZE-selected catalogue is inherently biased. We confirm this by comparing the ACT tSZE catalogue with optically and X-ray-selected cluster catalogues. Furthermore, there is a strong case for a large, high-resolution survey of clusters to better characterize their source population.

79 ASTRONOMY AND ASTROPHYSICS↗

Preliminary investigation of an uncertainty budget for uranium isotope ratio analysis using a liquid sampling—atmospheric pressure glow discharge—orbitrap mass spectrometer system

The liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source has proven to be an effective analysis tool for making uranium isotope ratio measurements when coupled to high-resolution mass spectrometers, such as the Orbitrap. While previous studies have shown the capabilities of the LS-APGD for isotope ratio determination, a systematic evaluation of the measurement uncertainty of the technique has not been conducted. To this end, the International Standards Organizations (ISO) guidelines to the expression of uncertainty in measurement (GUM analysis) have been applied to generate an uncertainty budget. For this work, a preliminary assessment derived from the GUM analysis was performed. The uncertainty in the instrument blank determination has been identified as a primary factor contributing to measurement uncertainty for the LS-APGD-Orbitrap method. These findings for the specific test case of uranium isotopic analysis will be invaluable in applications across the breadth of isotope ratio mass spectrometry performed on this unique instrumental platform.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Multichannel Doppler fiber-imager spectrometer for spatiotemporal characterization of high-intensity laser-driven plasmas

Here, we demonstrate a flexible multichannel fiber-based imaging Doppler spectrometer to characterize plasmas in high intensity (≥1 × 10 18 W/cm 2 ) laser-plasma experiments at high repetition rates. This instrument collects data from ×21 different plasma locations combining optical fibers and a single imaging spectrometer. This diagnostic maps the plasma velocity evolution as a function of time with sub-pico-second resolution. Experimental results showing 2D velocity measurements of plasma with 20 μm spatial resolution are presented. Intensities of the order of 10 18 W/cm 2 were used to generate a plasma, while a much less intense, frequency doubled (400 nm), probe beam (10 11 W/cm 2 ) was used to measure the Doppler shift from the plasma critical surface. The instrument can be scaled to a larger number of channels (e.g., 100) still using a single spectrometer.

47 OTHER INSTRUMENTATION↗

DESI DR2 results. II. Measurements of baryon acoustic oscillations and cosmological constraints

We present baryon acoustic oscillation (BAO) measurements from more than 14 million galaxies and quasars drawn from the Dark Energy Spectroscopic Instrument (DESI) Data Release 2 (DR2), based on three years of operation. For cosmology inference, these galaxy measurements are combined with DESI Lyman-𝛼 forest BAO results presented in a companion paper (M. Abdul-Karim et al., companion paper, Phys. Rev. D 112, 083514 2025.). The DR2 BAO results are consistent with DESI DR1 and the Sloan Digital Sky Survey, and their distance-redshift relationship matches those from recent compilations of supernovae (SNe) over the same redshift range. The results are well described by a flat Λ cold dark matter (Λ⁢CDM) model, but the parameters preferred by BAO are in mild, 2.3⁢𝜎 tension with those determined from the cosmic microwave background (CMB), although the DESI results are consistent with the acoustic angular scale 𝜃 * that is well measured by Planck. This tension is alleviated by dark energy with a time-evolving equation of state parametrized by 𝑤0 and 𝑤𝑎, which provides a better fit to the data, with a favored solution in the quadrant with 𝑤 0 >−1 and 𝑤 𝑎 <0. This solution is preferred over Λ ⁢CDM at 3.1⁢𝜎 for the combination of DESI BAO and CMB data. When also including SNe, the preference for a dynamical dark energy model over Λ⁢ CDM ranges from 2.8 − 4.2⁢𝜎 depending on which SNe sample is used. We present evidence from other data combinations which also favor the same behavior at high significance. From the combination of DESI and CMB we derive 95% upper limits on the sum of neutrino masses, finding ∑𝑚 𝜈 < 0.064 eV assuming Λ ⁢CDM and ∑𝑚 𝜈 < 0.16 eV in the 𝑤0⁢𝑤𝑎 model. Unless there is an unknown systematic error associated with one or more datasets, it is clear that Λ⁢ CDM is being challenged by the combination of DESI BAO with other measurements and that dynamical dark energy offers a possible solution.

Baryon acoustic oscillations↗

Lidar Buoy Data Dictionary: For the 2020 – 2021 California Deployments

Pacific Northwest National Laboratory (PNNL) manages two AXYS WindSentinel™ buoys (Buoys #120 and #130) on behalf of the U.S. Department of Energy (DOE) that collect a comprehensive set of meteorological and oceanographic (metocean) data to support resource characterization for wind energy offshore. The buoys have been deployed off the California coast in partnership with the Bureau of Ocean Energy Management (BOEM) from September 2020 through October 2021. One buoy was deployed within the Morro Bay Call Area offshore central California; the other buoy was deployed within the Humboldt Call Area off the coast of northern California. The measurements from the buoys are used to characterize the metocean conditions near potential locations for offshore wind lease areas and are uploaded to DOE’s Data Archive and Portal (DAP). Plots are updated on the DAP webpage to visualize the recent metocean measurements. This document serves as a data dictionary – or reference guide – for understanding and interpreting the data available from the buoys. This document includes: (1) specifications for the buoy instrumentation (Section 2.0) (2) description of each plot and definition of measured parameters (Section 3.0) (3) description of data files and naming convention (Appendix A) (4) reference guide of measurements and variables (Appendix B).

17 WIND ENERGY↗

Passive Neutron Instrumentation and Applications

This chapter presents a description of most of the instruments that are currently in use for the measurement of plutonium and uranium using passive methods (without an external source). This includes the acquisition electronics as well as Singles counting methods, coincidence counting methods and multiplicity counting methods. The Singles counting applications include the measurement of waste and curium bearing materials. The coincidence counting applications include bulk plutonium, bulk uranium, waste and holdup measurements and fresh fuel assemblies. The multiplicity application description includes advantages and disadvantages and multiplicity detector design. There is also a description of some non-3He systems. The chapter concludes with a description of additional concepts: neutron imagers, list-mode data analysis, distributed source term analysis, unattended monitoring and MCNP modeling for detector design.

Coincidence shift register↗

Mapping structural heterogeneity at the nanoscale with scanning nano-structure electron microscopy (SNEM)

Here, in this work, we explore the use of scanning electron diffraction (also known as 4D-STEM) coupled with electron atomic pair distribution function analysis (ePDF) to understand the local order (structure and chemistry) as a function of position in a complex multicomponent system, a hot rolled, Ni-encapsulated, Zr 65 Cu 17.5 Ni 10 Al 7.5 bulk metallic glass (BMG), with a spatial resolution of 3 nm. We show that it is possible to gain insight into the chemistry and chemical clustering/ordering tendency in different regions of the sample, including in the vicinity of nano-scale crystallites that are identified from virtual dark field images and in heavily deformed regions at the edge of the BMG. In addition to simpler analysis, unsupervised machine learning was used to extract partial PDFs from the material, modeled as a quasi-binary alloy, and map them in space. These maps allowed key insights not only into the local average composition, as validated by EELS, but also a unique insight into chemical short-range ordering tendencies in different regions of the sample during formation. The experiments are straightforward and rapid and, unlike spectroscopic measurements, don’t require energy filters on the instrument. We spatially map different quantities of interest (QoI’s), defined as scalars that can be computed directly from positions and widths of ePDF peaks or parameters refined from fits to the patterns. We developed a flexible and rapid data reduction and analysis software framework that allows experimenters to rapidly explore images of the sample on the basis of different QoI’s. The power and flexibility of this approach are explored and described in detail. Because of the fact that we are getting spatially resolved images of the nanoscale structure obtained from ePDFs we call this approach scanning nano-structure electron microscopy (SNEM), and we believe that it will be powerful and useful extension of current 4D-STEM methods.

36 MATERIALS SCIENCE↗