Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

A TIME-DEPENDENT MODEL FOR MAGNETIC RECONNECTION IN THE PRESENCE OF A SEPARATOR

We present a model for separator reconnection due to an isolated reconnection process. Separator reconnection is a process which occurs in the neighborhood of a distinguished field line (the separator) connecting two null points of a magnetic field. It is, for example, important for the dynamics of magnetic flux at the dayside magnetopause and in the solar corona. We find that, above a certain threshold, such a reconnection process generates new separators, which leads to a complex system of magnetic flux tubes connecting regions of previously separated flux. Our findings are consistent with the findings of large numbers of separators in numerical simulations. We discuss how to measure and interpret the reconnection rate in a configuration with multiple separators.

79 ASTRONOMY AND ASTROPHYSICS↗

Quenching of an electric arc in a vacuum gap with a uniform transverse magnetic field

The breaking ability of a vacuum arc interrupter with a uniform transverse magnetic field formed by a system of permanent magnets was investigated experimentally. The vacuum interrupter with a 0.5-{mu}F shunting capacitor switched off a dc current of up to 150 A at magnetic fields of 100-180 mT. At magnetic fields of 120-160 mT, the breaking ability of the vacuum interrupter was increased to 300 A by introducing a nonuniformity in the magnetic field distribution near the contact surface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of Chebyshev Formalism to Identify Nonlinear Magnetic Field Components in Beam Transport Systems

An experiment was conducted at Jefferson Lab's Continuous Electron Beam Accelerator Facility to develop a beam-based technique for characterizing the extent of the nonlinearity of the magnetic fields of a beam transport system. Horizontally and vertically oriented pairs of air-core kicker magnets were simultaneously driven at two different frequencies to provide a time-dependent transverse modulation of the beam orbit relative to the unperturbed reference orbit. Fourier decomposition of the position data at eight different points along the beamline was then used to measure the amplitude of these frequencies. For a purely linear transport system one expects to find solely the frequencies that were applied to the kickers with amplitudes that depend on the phase advance of the lattice. In the presence of nonlinear fields one expects to also find harmonics of the driving frequencies that depend on the order of the nonlinearity. Chebyshev polynomials and their unique properties allow one to directly quantify the magnitude of the nonlinearity with the minimum error. A calibration standard was developed using one of the sextupole magnets in a CEBAF beamline. The technique was then applied to a pair of Arc 1 dipoles and then to the magnets in the Transport Recombiner beamline to measure their multipole content as a function of transverse position within the magnets.

43 PARTICLE ACCELERATORS↗

Tuning the magnetic ground state of Ce 1 - x Yb x RhIn 5 by Yb valence fluctuations

We characterize the properties of Ce 1–x Yb x RhIn 5 single crystals with 0 ≤ x ≤ 1 using measurements of powder x-ray diffraction, energy dispersive x-ray spectroscopy, electrical resistivity, magnetic susceptibility, specific heat, x-ray absorption near edge structure (XANES), and neutron diffraction. Here, the Yb valence v Yb , calculated from the magnetic susceptibility and measured using XANES, decreases from 3+ at x = 0 to ~2.1+ at x act = 0.2 , where x act is the measured Yb concentration. A transition from incommensurate to commensurate antiferromagnetism is observed in neutron diffraction measurements along Q = (0.5, 0.5, l) between 0.2 ≤ x act ≤ 0.27; this narrative is supported by specific-heat measurements in which a second robust feature appears at a temperature T I (T I < T N ) for the same concentration range. Magnetic susceptibility measurements also reveal features which provide additional evidence of magneticordering. The results of this study suggest that the evolution of the Yb valence plays a critical role in tuning the magnetic ground state of Ce 1–x Yb x RhIn 5 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

AI-Enabled Robotic NDE for Structural Damage Assessment and Repair

The aim of this paper is to develop the concept and a prototype of an intelligent mobile robotic platform that is integrated with nondestructive evaluation (NDE) capabilities for autonomous live inspection and repair. In many industrial environments, such as the application of power plant boiler inspection, human inspectors often have to perform hazardous and challenging tasks. There is a significant chance of injury, considering the confined spaces and limited visibility of the inspection environment and hazards such as pressurization and improper water levels. In order to provide a solution to eliminate these dangers, the concept of a new robotic system was developed and prototyped that is capable of autonomously sweeping the region to be inspected. The robot design contains systematic integration of components from robotics, NDE, and artificial intelligence (AI). A magnetic track system is used to navigate over the vertical steel structures required for examination. While moving across the inspection area, the robot uses an NDE sensor to acquire data for inspection and repair. This paper presents a design of a portable NDE scanning system based on eddy current array probes, which can be customized and installed on various mobile robot platforms. Machine learning methods are applied for semantic segmentation that will simultaneously localize and recognize defects without the need of human intervention. Experiments were conducted that show the NDE and repair capabilities of the system. Improvements in human safety and structural damage prevention, as well as lowering the overall costs of maintenance, are possible through the implementation of this robotic NDE system.

Materials Science↗

Magnetic breakdown and spin-zero effect in quantum oscillations in kagome metal CsV3Sb5

Abstract In the recently discovered kagome metal CsV 3 Sb 5 , an intriguing proposal invoking a doped Chern insulator state suggests the presence of small Chern Fermi pockets hosting spontaneous orbital-currents and large orbital magnetic moments. While the net thermodynamic magnetization is nearly insensitive to these moments, due to their antiferromagnetic alignment, their presence can be revealed by the Zeeman effect, which shifts electron energies in magnetic fields with a proportionality given by the effective g −factor. Here, we determine the g -factor using the spin-zero effect in magnetic quantum oscillations. A large g -factor enhancement is visible only in magnetic breakdown orbits between conventional and concentrated Berry curvature Fermi pockets that host large orbital moments. Such Berry-curvature-generated large orbital moments are almost always concealed by other effects. In this system, however, magnetic breakdown orbits due to the proximity to a conventional Fermi-surface section allow them to be visibly manifested in magnetic quantum oscillations. Our results provide a remarkable example of the interplay between electronic correlations and more conventional electronic bands in quantum materials.

36 MATERIALS SCIENCE↗

Multi-plate interceptive electron beam energy diagnostic—Implementation and validation

A previous publication [P. D. McChesney, “Multi-plate interceptive electron beam energy diagnostic—Theoretical design,” AIP Adv. (submitted)] reported a new interceptive electron beam kinetic energy measurement technique based on the beam penetration depth within a stack of conductive plates and gave results on the theoretical design of such a device. This paper expands on this and gives further results on the actual implementation of the diagnostic. The device geometry and measurement electronics system are described in detail. A prototype version of the multi-plate diagnostic was fabricated and tested using an electron linear accelerator at the Idaho Accelerator Center (IAC). A high-precision magnetic spectrometer system was designed and built for the purpose of validating the multi-plate diagnostic’s energy measurement capabilities. It was found that the diagnostic provides electron beam energy estimates that are accurate to better than the 10% level.

43 PARTICLE ACCELERATORS↗

Computer simulation of magnetization-controlled shunt reactors for calculating electromagnetic transients in power systems

A computer procedure for simulating magnetization-controlled dc shunt reactors is described, which enables the electromagnetic transients in electric power systems to be calculated. It is shown that, by taking technically simple measures in the control system, one can obtain high-speed reactors sufficient for many purposes, and dispense with the use of high-power devices for compensating higher harmonic components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tunable spin wave spectra in two-dimensional Ni{sub 80}Fe{sub 20} antidot lattices with varying lattice symmetry

Ferromagnetic antidot lattices are important systems for magnetic data storage and magnonic devices, and understanding their magnetization dynamics by varying their structural parameters is an important problems in magnetism. Here, we investigate the variation in spin wave spectrum in two-dimensional nanoscale Ni{sub 80}Fe{sub 20} antidot lattices with lattice symmetry. By varying the bias magnetic field values in a broadband ferromagnetic resonance spectrometer, we observed a stark variation in the spin wave spectrum with the variation of lattice symmetry. The simulated mode profiles showed further difference in the spatial nature of the modes between different lattices. While for square and rectangular lattices extended modes are observed in addition to standing spin wave modes, all modes in the hexagonal, honeycomb, and octagonal lattices are either localized or standing waves. In addition, the honeycomb and octagonal lattices showed two different types of modes confined within the honeycomb (octagonal) units and between two such consecutive units. Simulated internal magnetic fields confirm the origin of such a wide variation in the frequency and spatial nature of the spin wave modes. The tunability of spin waves with the variation of lattice symmetry is important for the design of future magnetic data storage and magnonic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Impulsive energy release and non-thermal emission in a confined M4.0 flare triggered by rapidly evolving magnetic structures

We present observations of a confined M4.0 flare from NOAA 11302 on 2011 September 26. Observations at high temporal, spatial, and spectral resolution from the Solar Dynamics Observatory, Reuven Ramaty High Energy Solar Spectroscopic Imager, and Nobeyama Radioheliograph observations enabled us to explore the possible triggering and energy release processes of this flare despite its very impulsive behavior and compact morphology. The flare light curves exhibit an abrupt rise of non-thermal emission with co-temporal hard X-ray (HXR) and microwave (MW) bursts that peaked instantly without any precursor emission. This stage was associated with HXR emission up to 200 keV that followed a power law with photon spectral index (γ) ∼ 3. Another non-thermal peak, observed 32 s later, was more pronounced in the MW flux than the HXR profiles. Dual peaked structures in the MW and HXR light curves suggest a two-step magnetic reconnection process. Extreme ultraviolet (EUV) images exhibit a sequential evolution of the inner and outer core regions of magnetic loop systems while the overlying loop configuration remained unaltered. Combined observations in HXR, (E)UV, and Hα provide support for flare models involving the interaction of coronal loops. The magnetograms obtained by the Helioseismic and Magnetic Imager reveal emergence of magnetic flux that began ∼five hr before the flare. However, the more crucial changes in the photospheric magnetic flux occurred about one minute prior to the flare onset with opposite polarity magnetic transients appearing at the early flare location within the inner core region. The spectral, temporal, and spatial properties of magnetic transients suggest that the sudden changes in the small-scale magnetic field have likely triggered the flare by destabilizing the highly sheared pre-flare magnetic configuration.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic contribution of itinerant electrons to neutron diffraction in the topological antiferromagnet CeAlGe

We report a neutron diffraction study of the magnetic structure of CeAlGe, a candidate topological semimetal that hosts a noncollinear, multi-𝐤 magnetic phase. By measuring both low- and high-momentum-transfer magnetic Bragg peaks within a single experimental setup, we refine a magnetic structure model based solely on localized Ce moments. This model, which differs from that obtained using only high-𝑄 data, quantitatively reproduces the observed intensities, including the (000) zeroth-order magnetic satellites that are especially sensitive to subtle components of the modulation. While a contribution from itinerant electrons to the zeroth satellite cannot be definitively excluded, our analysis reveals no unambiguous evidence for such effects within experimental uncertainty. The refined magnetic structures exhibit topologically nontrivial winding patterns, derived from the fitted magnetic parameters, that support localized, particle-like spin textures with half-integer topological charges. These features provide a natural microscopic origin for the observed topological Hall effect, establishing CeAlGe as a model system where magnetism and topology are intimately linked.

Magnetic coupling↗

Large-amplitude Blazar Polarization Angle Swing as a Signature of Magnetic Reconnection

We report that relativistic magnetic reconnection events may exist in magnetized plasmas in astrophysical systems. During this process, oppositely directed magnetic field lines reconnect and release magnetic energy, efficiently accelerating nonthermal particles. However, so far there is little clear observational signatures of relativistic magnetic reconnection events in astrophysical systems. Blazars are relativistic magnetized plasma outflows from supermassive black holes. Their multi-wavelength flares may be powered by relativistic magnetic reconnection. The highly variable radiation and polarization signatures are well covered by multi-wavelength observation campaigns, making them ideal targets to examine the magnetic reconnection model. Recent observations have found that several blazar flares are accompanied by optical polarization angle swings that may have an amplitude as large as >180°, challenging existing theoretical models. In this Letter, we present integrated particle-in-cell and polarized radiation transfer simulations of magnetic reconnection events. We find that plasmoid coalescences in the reconnection layer can give rise to highly variable light curves, low and fluctuating polarization degree, and rotating polarization angle. Lastly, in particular, large-amplitude polarization angle swings, similar to those observed during blazar flares, can be a unique signature of relativistic magnetic reconnection events.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic nano-sorbents for fast separation of radioactive waste

In order to find a cost effective and environmentally benign technology to treat the liquid radioactive waste into a safe and stable form for resource recycling or ultimate disposal, this study investigates the separation of radioactive elements from aqueous systems using magnetic nano-sorbents. Our current study focuses on novel magnetic nano-sorbents by attaching DTPA molecules onto the surface of double coated magnetic nanoparticles (dMNPs), and performed preliminary sorption tests using heavy metal ions as surrogates for radionuclides. The results showed that the sorption of cadmium (Cd) and lead (Pb) onto the dMNP-DTPA conjugates was fast, the equilibrium was reached in 30 min. The calculated sorption capacities were 8.06 mg/g for Cd and 12.09 mg/g for Pb. After sorption, the complex of heavy elements captured by nano-sorbents can be easily manipulated and separated from solution in less than 1 min by applying a small external magnetic field. In addition, the sorption results demonstrate that dMNP-DTPA conjugates have a very strong chelating power in highly diluted Cd and Pb solutions (1-10 μg/L). Therefore, as a simple, fast, and compact process, this separation method has a great potential in the treatment of high level waste with low concentration of transuranic elements compared to tradition nuclear waste treatment. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hf thickness dependence of spin-orbit torques in Hf/CoFeB/MgO heterostructures

We have studied the spin-orbit torques in perpendicularly magnetized Hf/CoFeB/MgO system, by systematically varying the thickness of Hf underlayer. We have observed a sign change of effective fields between Hf thicknesses of 1.75 and 2 nm, indicating that competing mechanisms, such as the Rashba and spin Hall effects, contribute to spin-orbit torques in our system. For larger Hf thicknesses (>2 nm), both the components of spin-orbit torques arise predominantly from the bulk spin Hall effect. We have also confirmed these results using spin-orbit torque induced magnetization switching measurements. Our results could be helpful in designing Hf based SOT devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental confirmation of the magnetic ordering transition induced by an electronic structure change in the metallic triangular antiferromagnet Co 1/3⁢ TaS 2

We report angle-resolved photoemission spectroscopy (ARPES) studies combined with DFT+DMFT calculations to confirm that the magnetic ordering vector transition from Q=(1/2,0,0) to Q=(1/3,0,0) in the metallic triangular antiferromagnets Co 1/3±𝜀⁢ TaS 2 (𝜀 ≈ 0.007) is induced by the electronic structure change in the system. The ARPES-measured Fermi surface (FS) maps of Co 0.325 ⁢TaS 2 show two hexagonal and one circular holelike FSs around Γ, which matches well with the triple- Q state by taking into account the contribution of nesting vectors occurring between Co 3⁢𝑑 and Ta 5⁢𝑑 orbitals. In the case of Co 0.340 ⁢TaS 2 , a new electron pocket around K appears, and the FS geometry changes as a result of the correlation effect of Co 4 ⁢S 18 tripods forming in the system. The magnetic susceptibility calculations based on the charge-self-consistent DFT+DMFT band structures and the random phase approximation indicate that the most stable magnetic ordering vector (1/2,0,0) split into (1/6,0,0) and (1/2,0,0), which is consistent with the magnetic phase transition around 𝑥=1/3 in Co 𝑥 ⁢TaS 2 .

Fermi surface↗

NSLS-II: Turn-by-Turn BPM Data Analysis – A Use Case Approach

A modern ring-based light source is a complex dynamic system for which the design is guided by a realistic computer model with predictable results. State-of-the-arts beam requirements translate into tight engineering tolerances. So, quality assurance for the equipment, e.g. ring magnets, girder system, power supplies, RF system, etc. is crucial to deliver on the design goals for the beam quality. For a streamlined commissioning and an effective approach for integration of insertion devices, the latter being an activity that is typically on-going for the entire life cycle of the facility, it is equally important to be able to calibrate the beam dynamics design model against the real system and pursue e.g. “gap analysis”, linear and nonlinear optics corrections, improvements to the baseline design, etc. In particular, for high-end insertion devices. Conceptually, it can be thought of as pursuing Model-Based and Adaptive Control; instead of “flying blind”. A straightforward approach is to use a pinger, a ~30 cm long hor/ver kicker that can kick the beam to about 1 mrad in each plane [1-2] and a Turn-by-Turn BPM data acquisition system that records the betatron motion on a Turn-by-Turn basis. Examples include: ALS, SLS, DIAMOND, and SOLEIL. We first outline how to measure the Beam Impulse Response (BIR) function and related Beam Transfer Function (BTF) with a Turn-by-Turn BPM data acquisition system and a pinger. In particular, how to obtain the amplitude and phase of the spectral components in the betatron spectrum with high precision by using signal processing. We also quantify how the impact of noise affects the accuracy of the measurements.

97 MATHEMATICS AND COMPUTING↗

NSLS-II Turn-by-Turn BPM Data Analysis - A Use Case Approach

A modern ring-based light source is a complex dynamic system for which the design is guided by a realistic computer model with predictable results. State-of-the-arts beam requirements translate into tight engineering tolerances. So, quality assurance for the equipment, e.g. ring magnets, girder system, power supplies, RF system, etc. is crucial to deliver on the design goals for the beam quality. For a streamlined commissioning and an effective approach for integration of insertion devices, the latter being an activity that is typically on-going for the entire life cycle of the facility, it is equally important to be able to calibrate the beam dynamics design model against the real system and pursue e.g. “gap analysis”, linear and nonlinear optics corrections, improvements to the baseline design, etc. In particular, for high-end insertion devices. Conceptually, it can be thought of as pursuing Model-Based and Adaptive Control; instead of “flying blind”. A straightforward approach is to use a pinger, a ~30 cm long hor/ver kicker that can kick the beam to about 1 mrad in each plane [1-2] and a Turn-by-Turn BPM data acquisition system that records the betatron motion on a Turn-by-Turn basis. Examples include: ALS, SLS, DIAMOND, and SOLEIL.

36 MATERIALS SCIENCE↗

Development of a cross-polarization scattering system for the measurement of internal magnetic fluctuations in the DIII-D tokamak

The design and performance of a new cross-polarization scattering (CPS) system for the localized measurement of internal magnetic fluctuations is presented. CPS is a process whereby magnetic fluctuations scatter incident electromagnetic radiation into a perpendicular polarization which is subsequently detected. A new CPS design that incorporates a unique scattering geometry was laboratory tested, optimized, and installed on the DIII-D tokamak. Plasma tests of signal-to-noise, polarization purity, and frequency response indicate proper functioning of the system. CPS data show interesting features related to internal MHD perturbations known as sawteeth that are not observed on density fluctuations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗