Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Laser Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Heating and Sampling Efficiency Evaluation for the Nephele Venus Cloud Sampling Mission Concept

Nephele [1] is a descent probe concept with a unique combination of entry (3D-CC+HEEET), sampling (flow-through passive impactors), and optics (laser-induced breakdown spectroscopy, or LIBS, and surface-enhanced Raman spectroscopy, or SERS), technologies with two key innovations (Figure 1). The first is the integration of the aerosol sampling inlet into the aeroshell body, allowing the possibility of sampling during passive descent without separation. The second is the use of the aerosol capture surface as an optical analysis substrate, allowing fast-cadence aerosol analysis via a dual optical spectrometer instead of mass spectrometry. Although this concept shares some features with other efforts such as Cupid’s Arrow [1] (single-body sample capture system), DAVINCI [2] and Venera-D [3] (use of an optical spectrometer), Nephele is unique in its physical integration of the sonde body, aerosol and gas sampler, and analysis instrumentation. This innovation is designed to eliminate the need for a controlled descent to achieve a detailed atmospheric aerosol transect, which offers in situ planetary science in a small spacecraft envelope. Aeroshell designs with inlets for free-falling sondes are well-understood, though not yet assessed for aerosol capture efficiency. A HEEET aeroshell with a specialized nose inlet material comprised of Carbon-Carbon is proposed for this mission concept.

Venus↗

Heating and Sampling Efficiency Evaluation for the Nephele Venus Cloud Sampling Mission Concept

Nephele is a descent probe concept with a unique combination of entry (3D-CC+HEEET), sampling (flow-through passive impactors), and optics (laser-induced breakdown spectroscopy, or LIBS, and surface-enhanced Raman spectroscopy, or SERS), technologies with two key innovations. The first is the integration of the aerosol sampling inlet into the aeroshell body, allowing the possibility of sampling during passive descent without separation. The second is the use of the aerosol capture surface as an optical analysis substrate, allowing fast-cadence aerosol analysis via a dual optical spectrometer instead of mass spectrometry. Although this concept shares some features with other efforts such as Cupid’s Arrow (single-body sample capture system), DAVINCI and Venera-D (use of an optical spectrometer), Nephele is unique in its physical integration of the sonde body, aerosol and gas sampler, and analysis instrumentation. This innovation is designed to eliminate the need for a controlled descent to achieve a detailed atmospheric aerosol transect, which offers in situ planetary science in a small spacecraft envelope. Aeroshell designs with inlets for free-falling sondes are well-understood, though not yet assessed for aerosol capture efficiency. A HEEET aeroshell with a specialized nose inlet material comprised of Carbon-Carbon is proposed for this mission concept.

Venus↗

Petrological Traverse of the Olivine Cumulate Séítah Formation at Jezero Crater, Mars: A Perspective From SuperCam Onboard Perseverance

Séítah is the stratigraphically lowest formation visited by Perseverance in the Jezero crater floor. We present the data obtained by SuperCam: texture by imagery, chemistry by Laser-Induced Breakdown Spectroscopy, and mineralogy by Supercam Visible and Infrared reflectance and Raman spectroscopy. The Séítah formation consists of igneous, weakly altered rocks dominated by millimeter-sized grains of olivine with the presence of low-Ca and high-Ca pyroxenes, and other primary minerals (e.g., plagioclase, Cr-Fe-Ti oxides, phosphates). Along a ∼140 m long section in Séítah, SuperCam analyses showed evidence of geochemical and mineralogical variations, from the contact with the overlying Máaz formation, going deeper in the formation. Bulk rock and olivine Mg#, grain size, olivine content increase gradually further from the contact. Along the section, olivine Mg# is not in equilibrium with the bulk rock Mg#, indicating local olivine accumulation. These observations are consistent with Séítah being the deep ultramafic member of a cumulate series derived from the fractional crystallization and slow cooling of the parent magma at depth. Possible magmatic processes and exhumation mechanisms of Séítah are discussed. Séítah rocks show some affinity with some rocks at Gusev crater, and with some Martian meteorites suggesting that such rocks are not rare on the surface of Mars. Séítah is part of the Nili Fossae regional olivine-carbonate unit observed from orbit. Future exploration of Perseverance on the rim and outside of the crater will help determine if the observations from the crater floor can be extrapolated to the whole unit or if this unit is composed of distinct sub-units with various origins.

Mars 2020↗

Mineral composition of Al-rich float rocks in Jezero crater as seen by Super-Cam

During its traverse across the Jezero crater floor and western fan, the Perseverance rover encountered > 4000 float rocks – of variable size (up to ~ 50 cm) scattered on the ground without apparent connection to the surrounding stratigraphy [1]. Analysis performed using the SuperCam instrument’s [2,3,4], Laser Induced Breakdown Spectroscopy (LIBS) revealed a high concentration of Al 2 O 3 , Cr, Ti and Ni [5], and very low of Fe, Mg, Ca and Na [5, 1]. SuperCam’s infrared reflectance spectroscopy (IRS, between 1.3 and 2.6 μm) showed the presence of Al-rich aqueous alteration minerals (characteristic absorption bands of kaolinite and Al-smectites at 1.4 and 2.2 μm) as well as some (likely Cr-) spinels, identified uthrough their broad asymmetric 2 μm band, responsible for the concavity of IR spectra. These mineral species alone do not fully account for the spectral shapes; hence, the objective is to further investigate spectral modeling to determine the most probable mineral assemblages. Here, we present the results of modeling 17 light-toned float rocks, up to Sol 924, complementary to [1].

C. Royer↗

High Precision and Spatial Resolution Chemical Interrogation of Planetary Materials Using fs-LA/LIBS in Tandem With Multi-Collector ICP-MS

Combining femtosecond laser ablation (fs-LA) with laser-induced breakdown spectroscopy (LIBS), together with multi-collector inductively coupled plasma mass spectrometry (MC-ICPMS), can provide remarkable insights into the composition, structure, and therefore geologic history of planetary materials and their terrestrial analogs. Using the Applied Spectra iX-fs-Tandem LA-LIBS Instrument and the Nu SP1700 MC-ICP-MS housed within the Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center, we present preliminary tandem fs-LA-(MC)-ICP-MS/LIBS measurements of planetary analog materials. The synergistic integration of fs-LA-LIBS offers high spatial resolution elemental mapping, enabling the identification of microscale variations within samples. Simultaneously, the MC-ICP-MS can deliver precise isotopic analyses, and integrating the two datasets yields a wealth of geochemical information for a given sample. LA-based chemical mapping experiment designs are contingent on the information sought (i.e., quantitative, or semi-quantitative) and the preferred or available volume of material removed for the analysis. For example, occasionally, there are significant limitations in the depth of ablation due to the sample value, the amount of material available, or simply the need to coordinate with other in-situ techniques. In these limited sample scenarios, the “depth-controlled” chemical maps allow for precise post-mapping ion-polishing of the sample, while the isotopic and elemental maps can be used for targeting future analyses (e.g., conventional LA analyses, SIMS analyses, and micro milling for solution ICP-MS/TIMS). The emerging methodology will establish a powerful tool for investigation of astromaterials and materials returned by future planetary sample science missions.

Jacob B Setera↗

Multiple stage sorting

A material sorting system sorts materials utilizing multiple stages of classification and sorting, including a vision system that implements a machine learning system in order to identify or classify each of the materials, and Laser Induced Breakdown Spectroscopy to perform a subsequent classification and sorting of the remaining materials.

97 MATHEMATICS AND COMPUTING↗

Evaluation of Material Balance Approaches for Hanford Direct-Feed Low Activity Waste Processing - 20022

The Hanford Site has accumulated millions of gallons of tank waste from reprocessing spent fuel to recover plutonium, uranium, cesium, and strontium. The supernatant from the accumulated tank waste will be treated using a Direct Feed Low-Activity Waste approach. The supernatant will be treated to remove solids and cesium in the Tank-Side Cesium Removal process in the Hanford tank farm, then vitrified in a semi-batch process in the Hanford Waste Treatment and Immobilization Plant (WTP). Currently, each batch of feed is sampled at three locations prior to being fed to the melter: the feed qualification tank in the Hanford tank farm as well as the concentrate receipt vessel (CRV) and melter feed preparation vessel (MFPV) in the WTP. The feed qualification sample is taken from a large batch of accumulated feed, only two to three samples are expected each year. Approximately 275 samples from the CRVs and 1100 samples from the MFPV are expected each year. An evaluation was performed to determine if a material balance based on the feed qualification sample could replace most of the sampling in the CRVs and MFPVs. The evaluation consisted of three elements: (1) determination of the practicality of using a material balance to estimate the stream composition of the CRV and MFPV contents, (2) evaluation of whether the material balance could be automated using the existing process control system, and (3) determination of the uncertainty in glass composition using the material balance approach. It is assumed that periodic sampling at the CRV and MFPV would be performed periodically to re-baseline the material balance, evaluations are in progress to determine the frequency of this periodic sampling. Process sample locations downstream of the melter were reviewed as well, but the partitioning of semi-volatile species in the melter was determined to preclude extending the material balance approach past the melter. It was determined that replacement of the CRV sample location was feasible and did not increase process uncertainty or significantly impact waste loading. Replacement of the MFPV sample was also determined to be feasible, but that measurement of the glass former chemical addition may be needed prior to addition of these chemicals to the MFPV. This measurement could be performed by an in situ laser-induced breakdown spectroscopy (LIBS) system. Limited tests were performed to evaluate LIBS for direct measurements of the low-activity waste melter feed. The use of a material balance would eliminate over 1200 samples each year if only 10% of the CRV and MFPV batches are sampled and could likely allow the WTP laboratory to operate on days only versus 24/7 operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extended X-ray absorption spectroscopy using an ultrashort pulse laboratory-scale laser-plasma accelerator

Laser-driven compact particle accelerators can provide ultrashort pulses of broadband X-rays, well suited for undertaking X-ray absorption spectroscopy measurements on a femtosecond timescale. Here the Extended X-ray Absorption Fine Structure (EXAFS) features of the K-edge of a copper sample have been observed over a 250 eV window in a single shot using a laser wakefield accelerator, providing information on both the electronic and ionic structure simultaneously. This capability will allow the investigation of ultrafast processes, and in particular, probing high-energy-density matter and physics far-from-equilibrium where the sample refresh rate is slow and shot number is limited. For example, states that replicate the tremendous pressures and temperatures of planetary bodies or the conditions inside nuclear fusion reactions. Using high-power lasers to pump these samples also has the advantage of being inherently synchronised to the laser-driven X-ray probe. A perspective on the additional strengths of a laboratory-based ultrafast X-ray absorption source is presented.

43 PARTICLE ACCELERATORS↗

Indigenous Carbonaceous Matter in the Nakhla Mars Meteorite

Detailed microanalysis of the Martian meteorite Nakhla has shown there are morphologically distinct carbonaceous features spatially associated with low-T aqueous alteration phases including salts and id-dingsite. A comprehensive suite of analytical instrumentation including optical microscopy, field emission scanning electron microscopy (FESEM), energy dispersive X-ray (EDX) spectroscopy, focused ion beam (FIB) microscopy, transmission electron microscopy (TEM), two-step laser mass spectrometry (mu-L(sup 2)MS), laser mu-Raman spectroscopy, Fourier transform infrared spectroscopy (FTIR), and nanoscale secondary ion mass spectrometry (NanoSIMS) are being used to characterize the carbonaceous matter and host mineralogy. The search for carbonaceous matter on Mars has proved challenging. Viking Landers failed to unambiguously detect simple organics at either of the two landing sites although the Martian surface is estimated to have acquired at least 10(exp15) kg of C as a consequence of meteoritic accretion over the last several Ga. The dearth of organics at the Martian surface has been attributed to various oxidative processes including UV photolysis and peroxide activity. Consequently, investigations of Martian organics need to be focused on the sub-surface regolith where such surface processes are either severely attenuated or absent. Fortuitously since Martian meteorites are derived from buried regolith materials they provide a unique opportunity to study Martian organic geochemistry.

Clemett, S. J.↗

Subsurface Spectroscopy in Heterogeneous Materials Using Self-Healing Laser Beams

Self-healing optical beams are a class of propagation modes that can recover their beam shapes after distortion or partial blockage. This self-healing property makes them attractive for use in applications involving turbid media as they can—in theory—penetrate further into these materials than standard Gaussian beams. In this paper, we characterize the propagation of two different self-healing beams (Bessel and Airy) through a solid scattering material with different scatterer concentrations and find that both beams do recover after scattering for samples below a threshold scatterer concentration. Additionally, we test the applicability of both beam shapes for improved sub-surface spectroscopy in heterogeneous materials using fluorescent particles and find that there is an average fluorescence intensity enhancement of 1.3× using self-healing beams versus a standard Gaussian beam.

47 OTHER INSTRUMENTATION↗

Chemical and Isotopic Analysis of Trace Organic Matter on Meteorites and Interstellar Dust Using a Laser Microprobe Instrument

Polycyclic Aromatic Hydrocarbons (PAHs) are of considerable interest today because they are ubiquitous on Earth and in the interstellar medium (ISM). In fact, about 20% of cosmic carbon in the galaxy is estimated to be in the form of PAHs. Investigation of these species has obvious uses for determining the cosmochemistry of the solar system. Work in this laboratory has focused on four main areas: 1) Mapping the spatial distribution of PAHs in a variety of meteoritic samples and comparing this distribution with mineralogical features of the meteorite to determine whether a correlation exists between the two. 2) Developing a method for detection of fullerenes in extraterrestrial samples using microprobe Laser Desorption Ionization Mass Spectroscopy and utilizing this technique to investigate fullerene presence, while exploring the possibility of spatially mapping the fullerene distribution in these samples through in situ detection. 3) Investigating a possible formation pathway for meteoritic and ancient terrestrial kerogen involving the photochemical reactions of PAHs with alkanes under prebiotic and astrophysically relevant conditions. 4) Studying reaction pathways and identifying the photoproducts generated during the photochemical evolution of PAH-containing interstellar ice analogs as part of an ongoing collaboration with researchers at the Astrochemistry Lab at NASA Ames. All areas involve elucidation of the solar system formation and chemistry using microprobe Laser Desorption Laser Ionization Mass Spectrometry. A brief description of microprobe Laser Desorption Ionization Mass Spectroscopy, which allows selective investigation of subattomole levels of organic species on the surface of a sample at 10-40 micrometer spatial resolution, is given.

Zare, Richard N.↗

Photoluminescence and Raman spectroscopy of wide bandgap semiconductors damaged by deep-UV laser irradiation

The effects of a pulsed, focused, deep-UV (4.66 eV) laser on wide and ultra-wide bandgap semiconductors were investigated with photoluminescence (PL) and Raman spectroscopy. Three semiconductor single crystals were studied: silicon carbide (6H-SiC), gallium nitride (GaN), and gallium oxide (β-Ga 2 O 3 ). Atomic emission lines from neutral Ga or Si were observed during the laser-damage process. For all three semiconductors, PL mapping (3.49 eV laser excitation) of the damaged material revealed visible emission bands in the 2.6–2.8 eV range, attributed to point defects. Raman spectra (2.33 eV excitation) showed a reduction in the Raman peak intensities in the damaged region, along with weak PL bands around 1.9–2.1 eV.

36 MATERIALS SCIENCE↗

Coherent photon coincidence spectroscopy of single quantum systems

In this report nonequilibrium photon correlations of coherently excited single quantum systems can reveal their internal quantum dynamics and provide spectroscopic access. Here we propose and discuss the fundamentals of a coherent photon coincidence spectroscopy based on the application of laser pulses with variable delay and the detection of a time-averaged two-photon coincidence rate. For demonstration, two simple but important cases, i.e., an exciton-biexciton in a quantum dot and two coupled quantum emitters, are investigated based on quantum dynamics simulations demonstrating that this nonlinear spectroscopy reveals information specific to the particular single quantum system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Expansion dynamics and chemistry evolution in ultrafast laser filament produced plasmas

Laser ablation in conjunction with optical emission spectroscopy is a potential non-contact, standoff detection method for all elements in the periodic table and certain isotopes such as radionuclides. Currently, significant development efforts are on-going to use ultrafast laser filaments for remote sensing. The application of filaments is of particular interest in extending the range of stand-off capability associated with elemental and isotopic detection via laser-induced breakdown spectroscopy. In this study, we characterize the expansion dynamics and chemical evolution of filament-produced uranium (U) plasmas. Laser filaments are generated in the laboratory by loosely focusing 35 femtosecond (fs), 6 milli Joule (mJ) pulses in air. Two-dimensional spectrally-integrated and time-resolved imaging was performed to study hydrodynamics and evolution of U atomic and UO molecular emission in filament-produced U plasmas. Our results highlight that filament ablation of U plasmas gives a cylindrical plasma plume morphology with an appearance of plume splitting into slow and fast moving components at later times of its evolution. Emission from the slow-moving region shows no distinct spectral features (i.e. broadband-like) and is contributed in part by nanoparticles generated during ultrafast laser ablation. Additionally, we find U atoms and U oxide molecules (i.e. UO, UxOy) co-exist in the filament produced plasma, which can be attributed to the generation of low-temperature plasma conditions during filament ablation

(140.3440) Laser-induced breakdown, (280.5395) Pla↗

Molecular-Scale Characterization of Photoinduced Charge Separation in Mixed-Dimensional InSe–Organic van der Waals Heterostructures

Layered indium selenide (InSe) is an emerging two-dimensional semiconductor that has shown significant promise for high-performance transistors and photodetectors. The range of optoelectronic applications for InSe can potentially be broadened by forming mixed-dimensional van der Waals heterostructures with zero-dimensional molecular systems that are widely employed in organic electronics and photovoltaics. Here, we report the spatially resolved investigation of photoinduced charge separation between InSe and two molecules (C 70 and C 8 -BTBT) using scanning tunneling microscopy combined with laser illumination. We experimentally and computationally show that InSe forms type-II and type-I heterojunctions with C 70 and C 8 -BTBT, respectively, due to an interplay of charge transfer and dielectric screening at the interface. Laser-excited scanning tunneling spectroscopy reveals a ~0.25 eV decrease in the energy of the lowest unoccupied molecular orbital of C 70 with optical illumination. Furthermore, photoluminescence spectroscopy and Kelvin probe force microscopy indicate that electron transfer from InSe to C 70 in the type-II heterojunction induces a photovoltage that quantitatively matches the observed downshift in the tunneling spectra. In contrast, no significant changes are observed upon optical illumination in the type-I heterojunction formed between InSe and C 8 -BTBT. Density functional theory calculations further show that, despite the weak coupling between the molecular species and InSe, the band alignment of these mixed-dimensional heterostructures strongly differs from the one suggested by the ionization potential and electronic affinities of the isolated components. Self-energy-corrected density functional theory indicates that these effects are the result of the combination of charge redistribution at the interface and heterogeneous dielectric screening of the electron–electron interactions in the heterostructure. In addition to providing specific insight for mixed-dimensional InSe–organic van der Waals heterostructures, this work establishes a general experimental methodology for studying localized charge transfer at the molecular scale that is applicable to other photoactive nanoscale systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards the development of resonantly enhanced laser-based diagnostics for molten salt reactor safeguards

The adoption of Generation IV molten salt reactors (MSRs) depends on the ability to implement compatible monitoring instrumentation to ensure adherence to nuclear safeguards. This task is nontrivial due to the high temperature, reactive, and chemically complex fuel and coolant components contained within these systems. Optical spectroscopy techniques such as laser-induced fluorescence (LIF) and laser-induced breakdown spectroscopy (LIBS) are candidates for monitoring instrumentation. They offer many advantages for continuous monitoring, including the ability to operate at a standoff and compatibility with liquid-phase analytes. We discuss the use of LIF for the detection of Nd, a common fission fragment, within a liquid matrix. Results show that for NdCl3 dissolved in water, the Nd I 492.45 nm resonant transition is detectable without the need to induce a plasma and that the fluorescence emission can be separated in the time domain from the laser scatter signal. Additionally, we present a setup and preliminary results for measurements of solid Nd and U using resonant LIBS. The results demonstrate element-selective measurement capabilities and provide the foundational data necessary to continue the development of laser-based MSR diagnostics. This work also helps address gaps in the literature regarding energy level assignments of Nd.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗