Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIGHT SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

The use of new GAFCHROMIC EBT film for {sup 125}I seed dosimetry in Solid Water phantom

Radiochromic film dosimetry has been extensively used for intravascular brachytherapy applications for near field within 1 cm from the sources. With the recent introduction of new model of radiochromic films, GAFCHROMIC EBT, with higher sensitivity than earlier models, it is promising to extend the distances out to 5 cm for low dose rate (LDR) source dosimetry. In this study, the use of new model GAFCHROMIC EBT film for {sup 125}I seed dosimetry in Solid Water was evaluated for radial distances from 0.06 cm out to 5 cm. A multiple film technique was employed for four {sup 125}I seeds (Implant Sciences model 3500) with NIST traceable air kerma strengths. Each experimental film was positioned in contact with a {sup 125}I seed in a Solid Water phantom. The products of the air kerma strength and exposure time ranged from 8 to 3158 U-h, with the initial air kerma strength of 6 U in a series of 25 experiments. A set of 25 calibration films each was sequentially exposed to one {sup 125}I seed at about 0.58 cm distance for doses from 0.1 to 33 Gy. A CCD camera based microdensitometer, with interchangeable green (520 nm) and red (665 nm) light boxes, was used to scan all the films with 0.2 mm pixel resolution. The dose to each {sup 125}I calibration film center was calculated using the air kerma strength of the seed (incorporating decay), exposure time, distance from seed center to film center, and TG43U1S1 recommended dosimetric parameters. Based on the established calibration curve, dose conversion from net optical density was achieved for each light source. The dose rate constant was determined as 0.991 cGy U{sup -1} h{sup -1} ({+-}6.9%) and 1.014 cGy U{sup -1} h{sup -1} ({+-}6.8%) from films scanned using green and red light sources, respectively. The difference between these two values was within the uncertainty of the measurement. Radial dose function and 2D anisotropy function were also determined. The results obtained using the two light sources corroborated each other. We found good agreement with the TG43U1S1 recommended values of radial dose function and 2D anisotropy function, to within the uncertainty of the measurement. We also verified the dosimetric parameters in the near field calculated by Rivard using Monte Carlo method. The radial dose function values in Solid Water were lower than those in water recommended by TG43U1S1, by about 2%, 3%, 7%, and 14% at 2, 3, 4, and 5 cm, respectively, partially due to the difference in the phantom material composition. Radiochromic film dosimetry using GAFCHROMIC EBT model is feasible in determining 2D dose distributions around low dose rate {sup 125}I seed. It is a viable alternative to TLD dosimetry for {sup 125}I seed dose characterization.

61 RADIATION PROTECTION AND DOSIMETRY↗

NSLS-II Transport Line Progress

The National Synchrotron Light Source II (NSLS-II) is a state-of-the-art 3-GeV third generation light source currently under construction at Brookhaven National Laboratory. The NSLS-II injection system consists of a 200 MeV linac, a 3-GeV booster synchrotron and associated transfer lines. The first part of the Linac to Booster Transport (LBT) line has been installed for linac commissioning. This part includes all components necessary to commission the NSLS-II linac. The second part of this transport line is undergoing installation. Initial results of hardware commissioning will be discussed. The Booster to Storage Ring (BSR) transport line underwent a design review. The first part of the BSR transport line, consisting of all components necessary to commission the booster will be installed in 2012 for booster commissioning. We report on the final design of the BSR line along with the plan to commission the booster.

3-GeV↗

Morphological Expression of the Coherence and Relative Phase of Optical Inputs to the Photoelectrodeposition of Nanopatterned Se–Te Films

Highly anisotropic and ordered nanoscale lamellar morphologies can be spontaneously generated over macroscopic areas, without the use of a photomask or any templating agents, via the photoelectrodeposition of Se–Te alloy films. To form such structures, the light source can be a single, linearly polarized light source that need not necessarily be highly coherent. In this work, the variation in the morphologies produced by this deposition process was evaluated in response to differences in the coherence and relative phase between multiple simultaneous linearly polarized illumination inputs. Specifically, the morphologies of photoelectrodeposits were evaluated when two tandem same-wavelength sources with discrete linear polarizations, both either mutually incoherent or mutually coherent (with defined phase differences), were used. Additionally, morphologies were simulated via computer modeling of the interfacial light scattering and absorption during the photoelectrochemical growth process. The morphologies that were generated using two coherent, in-phase sources were equivalent to those generated using only a single source. In contrast, the use of two coherent, out-of-phase sources produced a range of morphological patterns. For small out-of-phase addition of orthogonal polarization components, lamellar-type patterns were observed. When fully out-of-phase orthogonal sources (circular polarization) were used, an isotropic, mesh-type pattern was instead generated, similar to that observed when unpolarized illumination was utilized. In intermediate cases, anisotropic lamellar-type patterns were superimposed on the isotropic mesh-type patterns, and the relative height between the two structures scaled with the amount of out-of-phase addition of the orthogonal polarization components. Similar results were obtained when two incoherent sources were utilized. In every case, the long axis of the lamellar-type morphology component aligned parallel to the intensity-weighted average polarization orientation. The observations consistently agreed with computer simulations, indicating that the observed morphologies were fully determined by the nature of the illumination utilized during the growth process. Here, the collective data thus indicated that the photoelectrodeposition process exhibits sensitivity toward the coherency, relative phase, and polarization orientations of all optical inputs and that this sensitivity is physically expressed in the morphology of the deposit.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

LED lamp or bulb with remote phosphor and diffuser configuration with enhanced scattering properties

An LED lamp or bulb is disclosed that comprises a light source, a heat sink structure and an optical cavity. The optical cavity comprises a phosphor carrier having a conversions material and arranged over an opening to the cavity. The phosphor carrier comprises a thermally conductive transparent material and is thermally coupled to the heat sink structure. An LED based light source is mounted in the optical cavity remote to the phosphor carrier with light from the light source passing through the phosphor carrier. A diffuser dome is included that is mounted over the optical cavity, with light from the optical cavity passing through the diffuser dome. The properties of the diffuser, such as geometry, scattering properties of the scattering layer, surface roughness or smoothness, and spatial distribution of the scattering layer properties may be used to control various lamp properties such as color uniformity and light intensity distribution as a function of viewing angle.

42 ENGINEERING↗

Compare low-gain 1D and 3D models toward a storage ring-based X-ray free-electron-laser oscillator

Fourth-generation diffraction-limited synchrotron light sources (DL-SLS) present a compelling platform for advanced light source applications due to their ultra-low emittance (around tens of picometers), sub-micrometer beam stability, and high repetition rates (greater than 1 MHz). Despite these advantages, fundamental limitations, such as long bunch durations (tens of picoseconds), large relative energy spread (~10⁻³), and low peak current (<300 A), have hindered their effectiveness in free-electron laser (FEL) applications. Using a low-gain three-dimensional (3D) model based on NSLS-II upgrade lattice parameters, we demonstrate that a 6% single-pass gain is achievable with an optimized transverse gradient undulator (TGU). Concurrently, recent advances in X-ray optics—specifically, a four-mirror bow-tie resonator utilizing diamond mirrors and beryllium compound refractive lenses (CRLs)—enable total round-trip losses below 4% and an output coupling efficiency near 1%, rendering a Storage Ring based X-ray FEL oscillator (XFELO) a realistic possibility. In the 3D framework, the TGU effectively mitigates the detrimental effects of large energy spread by spatially dispersing the beam, leading to enhanced gain relative to conventional one-dimensional (1D) models. We establish both analytical and numerical connections between the 1D and 3D descriptions, leveraging GENESIS simulations to map equivalent gain conditions. While 1D resonance is defined in the energy domain, the 3D TGU system shifts the resonance dependence to transverse gradient and dispersion parameters. Once optimized, this framework allows predictive modeling using 1D formulas, which can then be validated through full 3D simulations.

43 PARTICLE ACCELERATORS↗

Apparatus and methods for imaging interior surfaces of a tube or the like

An exemplary device includes, on a longitudinal axis, an illumination-light source, an axicon (conic) mirror, an image sensor, and a tilted optical element. The light source provides illumination light propagating forwardly on the axis. The axicon mirror reflects the illumination light radially outward, relative to the axis, to the interior surface of a tube to produce reflected light propagating, from the illuminated interior surface, as imaging light back to the axicon, which reflects the imaging light rearwardly. The image sensor receives at least a portion of the imaging light rearwardly reflected by the axicon mirror. The tilted optical element, situated between the axicon mirror and the interior surface, moves a selected first portion of the imaging light away from being incident on the image sensor, while allowing a second portion of the imaging light to be incident on the image sensor.

Kisner, Roger A.↗

Overview of Photoinjectors

High-brightness electron beam sources play a crucial role in many advanced acceleration schemes as well as linac-based light sources such as Energy Recovery Linac (ERL) based light sources and FELs. Three varieties electron sources (photo, thermionic, and field emission) the photoinjector is especially attractive due to its innate ability to control the time structure of intense electron bunches with low transverse and longitudinal emittance. In all cases, the quality of the bunch begins with the intrinsic emittance and time response of the photocathode, and we discuss the trade-offs involved between the various material choices. A variety of longitudinal laser pulse-shaping techniques are currently being developed to linearize space charge forces or create trains of ultra-short bunches. The emittance compensation technique mitigates the growth of the projected emittance due to the linear space charge force while the bunch is accelerated and compressed in an injector. While the normal conducting rf photoinjector is the workhorse of this field, the dc photoinjector is being pushed to its high-voltage limits, and the year 2010 promises to be a critical year for the superconducting rf photoinjector. Parallel to the development of the hardware, rapid progress has also been made with modeling codes, theory, and bench marking of diagnostics. We attempt to give both a tutorial of photoinjectors and a review of the current state of the art in this rapidly developing field.

43 PARTICLE ACCELERATORS↗

Chemical Imaging of Atmospheric Organic Particles in the Eastern North Atlantic Field Campaign Report

The ability to reliably predict future climate is hindered, in major part, by an insufficient understanding of atmospheric aerosol-radiation interactions and aerosol-cloud interactions. (IPCC 2013; Bony and Dufresne 2005) Factors affecting marine stratocumulus clouds are particularly important given that they are the dominant cloud type globally. Global climate models frequently misrepresent ubiquitous marine stratocumulus clouds for a variety of reasons, including a lack of understanding of how these cloud properties change with aerosol cloud condensation nuclei (CCN) concentration and composition.(Nam et al. 2012) Limited information is available regarding the sources of CCN in remote regions where marine stratocumulus clouds dominate. Measurements in these marine locations, which are periodically influenced by anthropogenic emissions, provide additional opportunity to study the impact of humans on cloud characteristics. The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility Eastern North Atlantic (ENA) observatory on Graciosa Island in the Azores is well suited to study these problems. The ENA site is exposed to a multitude of air masses as well as a variety of cloud regimes, as documented by passive and active satellite cloud retrieval. (Tselioudis et al. 2013) Thus, placing detailed aerosol and cloud measurements at the ARM ENA site may help gain a better understanding of the CCN budget and cloud interactions in remote environments. To provide detailed information on aerosol morphology, composition, and microphysical properties, size- segregated sampling was carried out at the ENA observatory on Graciosa Island during two intensive operating periods (IOPs). IOP1 occurred from June 17 to July 18, 2017, and IOP2 occurred from January 9 to February 21, 2018. Daytime and nighttime sampling were carried out separately to investigate any diurnal differences of aerosol composition due to differing meteorology. For both IOPs, a micro-orifice uniform deposit impactor (MOUDI) was used to collect particles for microscopic and microphysical analysis. A variety of microscopic substrates (formvar coated copper grids, silicon chips, silicon nitride windows, or molybdenum substrates) were used. Microscopic chemical characterization was carried out using computer-controlled scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy (CCSEM-EDX) and the synchrotron-based scanning transmission X-ray microscopy coupled with near-edge X-ray absorption spectroscopy (STXM-NEXAFS). (Laskin et al. 2006; Kilcoyne et al. 2003; Moffet et al. 2010) Two light sources were used for this analysis: 1) the Advanced Light Source at Lawrence Berkeley National Laboratory, and 2) The Canadian Light Source.

Eastern North Atlantic, ACE-ENA field campaign, Gr↗

Systems and methods for crack detection

Embodiments related to systems and methods of crack detection in wafers (e.g., silicon wafers for photovoltaics, photovoltaic devices including silicon wafers) are disclosed. In some embodiments, an apparatus may include a light source configured to illuminate a side of a wafer and a camera directed towards a first face of the wafer. In some embodiments, a long axis of a field of view of the camera may be angled relative to a propagation direction of the light source. In some embodiments, at least a portion of the field of view of the camera is offset from the path of propagation of light emitted from the light source through the wafer. In some embodiments, at least a portion of a light beam may be oriented at a positive non-zero angle relative to the first face of the wafer, and a dimension of the light beam normal to the first face of the wafer may be larger than a thickness of the wafer.

14 SOLAR ENERGY↗

NSLS-II Preliminary Design Report

Following the CD0 approval of the National Synchrotron Light Source II (NSLS-II) during August 2005, Brookhaven National Laboratory prepared a conceptual design for a worldclass user facility for scientific research using synchrotron radiation. DOE SC review of the preliminary baseline in December 2006 led to the subsequent CD1 approval (approval of alternative selection and cost range). This report is the documentation of the preliminary design work for the NSLS-II facility. The preliminary design of the Accelerator Systems (Part 1) was developed mostly based of the Conceptual Design Report, except for the Booster design, which was changed from in-storage-ring tunnel configuration to in external- tunnel configuration. The design of beamlines (Part 2) is based on designs developed by engineering firms in accordance with the specification provided by the Project. The conventional facility design (Part 3) is the Title 1 preliminary design by the AE firm that met the NSLS-II requirements. Last and very important, Part 4 documents the ES&H design and considerations related to this preliminary design. The NSLS-II performance goals are motivated by the recognition that major advances in many important technology problems will require scientific breakthroughs in developing new materials with advanced properties. Achieving this will require the development of new tools that will enable the characterization of the atomic and electronic structure, chemical composition, and magnetic properties of materials, at nanoscale resolution. These tools must be nondestructive, to image and characterize buried structures and interfaces, and they must operate in a wide range of temperatures and harsh environments. The NSLS-II facility will provide ultra high brightness and flux and exceptional beam stability. It will also provide advanced insertion devices, optics, detectors, and robotics, and a suite of scientific instruments designed to maximize the scientific output of the facility. Together these will enable the study of material properties and functions with a spatial resolution of {approx}1 nm, an energy resolution of {approx}0.1 meV, and the ultra high sensitivity required to perform spectroscopy on a single atom. In order to meet this need, NSLS-II has been designed to provide world-leading brightness and flux and exceptional beam stability. The brightness is defined as the number of photons emitted per second, per photon energy bandwidth, per solid angle, and per unit source size. Brightness is important because it determines how efficiently an intense flux of photons can be refocused to a small spot size and a small divergence. It scales as the ring current and the number of total periods of the undulator field (both of which contribute linearly to the total flux), as well as eing nversely proportional to the horizontal and vertical emittances (the product of beam size and divergence) of the electron beam. Raising the current in the storage ring to obtain even brighter beams is ultimately limited by beam-driven, collective instabilities in the accelerator. Thus, to maximize the brightness, the horizontal and vertical emittances must be made as small as possible. With the concept of using damping wigglers, low-field bending magnets, and a large number of lattice cells to achieve ultra small emittance, the performance of NSLS-II will be nearly at the ultimate limit of storage ring light sources, set by the intrinsic properties of the synchrotron radiation process. The facility will produce x-rays more than 10,000 times brighter than those produced at NSLS today. The facility, with various insertion devices, including three-pole-wigglers and low-field dipole radiations, has the capability of covering a broad range of radiation spectra, from hard x-ray to far infra-red. The superlative character and combination of capabilities will have broad impact on a wide range of disciplines and scientific initiatives in the coming decades, including new studies of small crystals in structural biology, a wide range of nanometer-resolution probes for nanoscience, coherent imaging of the structure and dynamics of disordered materials, greatly increased applicability of inelastic x-ray scattering, and properties of materials under extreme conditions. Commissioned in 1982, the existing National Synchrotron Light Source (NSLS) provides essential scientific tools for 2,300 scientists per year from more than 400 academic, industrial, and government institutions. Their myriad research programs produce about 800 publications per year, with more than 130 appearing in premier journals. It was designed in the 1970s and is now in its third decade of service. It has been continually upgraded over the years, with the brightness increasing fully five orders of magnitude. However, it has reached the theoretical limits of performance given its small circumference and small periodicity, and only a small number of insertion devices are possible.

43 PARTICLE ACCELERATORS↗

Overview of Lattice Design and Evaluation for the APS Upgrade

The Advanced Photon Source (APS) is a 7-GeV synchrotron light source that has been in operation since 1996. Since that time, the effective emittance has been decreased from 8 nm to 3.1 nm, which is very competitive for a 3rd-generation light source. However, newer facilities such as PETRA-III, NSLS-II, and MAX-IV are pushing the emittance to significantly smaller values. MAX-IV in particular has set the current benchmark with an emittance of about 300 pm at 3 GeV. This was accomplished by use of a multi-bend achromat lattice, which takes advantage of the 1/M3 scaling of the emittance with respect to the number of dipoles M. In order to ensure that our facility remains competitive, APS is pursuing a major upgrade, which involves replacement of the existing double-bend lattice with a seven-bend achromat lattice, promising a 40-fold reduction in emittance. This paper describes the process of developing and evaluating candidate lattice designs. Two candidate 6-GeV lattices are described: one providing a natural emittance of 67 pm and the other providing 41 pm. Our analysis includes single-particle dynamics as well as single- and multi-bunch collective effects.

07 ISOTOPE AND RADIATION SOURCES↗

Visibility and annoyance of the phantom array effect varies with age and history of migraine

The phantom array effect (PAE) is a series of repeated images that may be perceived when a person moves their eyes in large saccades across a light source (or a specular reflection of that light source) that is modulating in output over time. Fifty-five people, including a group of 25 who experience migraine, evaluated the visibility and annoyingness of phantom arrays produced by 85 unique temporal light modulation waveforms (including sine, rectangular, complex and DC waveforms) generated using an LED placed against a black background. Those with migraine exhibited higher average visibility compared to those without migraine ( p = 0.019) and were relatively more sensitive at higher frequencies ( p < 0.001). Younger participants also found more stimuli to be visible ( p < 0.001). The threshold sensitivity function was similar to that developed for the phantom array visibility measure (PAVM), and PAVM was effective in predicting visibility ( R 2 = 0.87 for the relevant region of PAVM < 3). While those in the migraine group did not report seeing the PAE more often in everyday life at a statistically significant level, they reported being more annoyed by it and having more unwanted physiological responses (headaches, eye fatigue and distraction/disorientation). Members of the migraine group were also more likely to have changed their behaviour in architectural spaces (such as leaving a restaurant with ‘flickering’ lights). In the four hours after completing the experiment, 64% of the migraine group (vs. 19% of the non-migraine group) reported experiencing discomfort or an adverse reaction. In particular, 41% reported experiencing a headache (vs. 8% for those in the non-migraine group).

60 APPLIED LIFE SCIENCES↗

Demonstration of LED Retrofit Lamps at the Smithsonian Art Museum, Washington, DC

In the fall of 2010, Pacific Northwest National Laboratory contacted Scott Rosenfeld, Lighting Designer for the Smithsonian American Art Museum, to see if the Museum would be willing to participate in a GATEWAY demonstration project in which light-emitting diode (LED) replacement lamps would be used in exhibit space. At that time, the museum industry was concerned about increased damage potential from LEDs and other energy efficient lighting sources that produce a discontinuous spectrum. The Museum agreed to participate, based on a review of the existing literature conducted by Steven Weintraub of Art Preservation Services for the American Institute of Conservation, and subsequent testing of solid-state lighting sources on light sensitive materials performed by Jim Druzik of the Getty Conservation Institute. Thus began the process, which lasted more than a year, of procuring lamp samples and performance data, testing them in the museum workshop, temporarily installing the lamps in one gallery for feedback, and ultimately replacing all traditional incandescent lamps in one gallery of modernist art at the American Art Museum and partially replacing lamps in two galleries of the Museum’s Renwick Gallery. This report describes the selection and testing process, technology challenges, perceptions, economics, energy use, and mixed results of using LED replacement lamps in art galleries housing national treasures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

System and method for grain refinement and general control of grain morphology in laser additive manufacturing

The present disclosure relates to a system for forming a material layer that may make use of an optical light source for generating an optical beam, and a beam shaping subsystem configured to shape the optical beam to generate a complex beam intensity profile. The complex shaped beam may be used to selectively melt at least portions of a bed of powder particles residing on a substrate during formation of the material layer, as the optical light source is moved. A computer may be used to control the optical light source. The complex beam intensity profile enables control over the microstructure of grains formed during melting of the powder particles as the material layer is formed.

Roehling, Tien↗

Simulations of coherent scattering experiments at storage ring synchrotron radiation sources in the hard x-ray range

Detailed simulations of experiments carried out at modern light sources are directly related to the most efficient and productive use of these facilities for research in multiple branches of science and technology. The “Synchrotron Radiation Workshop” computer code with its Python interface, and Sirepo web-browser-based graphical user interface, currently supports physical optics simulations of coherent X-ray scattering and imaging experiments on user-defined virtual samples. We present examples of simulations of coherent scattering experiments that are typically performed at the Coherent Hard X-ray beamline at Brookhaven National Laboratory’s (BNL) National Synchrotron Light Source II. We also present several comparisons of the simulations with the results of actual coherent X-ray scattering experiments with nano-fabricated test samples produced at BNL’s Center for Functional Nanomaterials.

36 MATERIALS SCIENCE↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Characterizations of a KHz Pulsed Laser Detection System

A KHz Pulsed Laser Detection System was developed employing the concept of charge integration with an electrometer, in the NASA Goddard Space Flight Center, Code 618 Calibration Lab for the purpose of using the pulsed lasers for radiometric calibration. Comparing with traditional trans-impedance (current-voltage conversion) detection systems, the prototype of this system consists of a UV-Enhanced Si detector head, a computer controlled shutter system and a synchronized electrometer. The preliminary characterization work employs light sources running in either CW or pulsed mode. We believe this system is able to overcome the saturation issue when a traditional trans-impedance detection system is used with the pulsed laser light source, especially with high peak-power pulsed lasers operating at kilohertz repetition rates (e.g. Ekspla laser or KHz OPO). The charge integration mechanism is also expected to improve the stability of measurements for a pulsed laser light source overcoming the issue of peak-to-peak stability. We will present the system characterizations including signal-to-noise ratio and uncertainty analysis and compare results against traditional trans-impedance detection systems.

Ding, Leibo↗

Reversible Seeding in Storage Rings

We propose to generate steady-state microbunching in a storage ring with a reversible seeding scheme. High gain harmonic generation (HGHG) and echo-enabled harmonic generation (EEHG) are two promising methods for microbunching linac electron beams. Because both schemes increase the energy spread of the seeded beam, they cannot drive a coherent radiator turn-by-turn in a storage ring. However, reversing the seeding process following the radiator minimizes the impact on the electron beam and may allow coherent radiation at or near the storage ring repetition rate. In this paper we describe the general idea and outline a proof-of-principle experiment. Electron storage rings can drive high average power light sources, and free-electron lasers (FELs) are now producing coherent light sources of unprecedented peak brightness While there is active research towards high repetition rate FELs (for example, using energy recovery linacs), at present there are still no convenient accelerator-based sources of high repetition rate, coherent radiation. As an alternative avenue, we recently proposed to establish steady-state microbunching (SSMB) in a storage ring. By maintaining steady-state coherent microbunching at one point in the storage ring, the beam generates coherent radiation at or close to the repetition rate of the storage ring. In this paper, we propose a method of generating a microbunched beam in a storage ring by using reversible versions of linac seeding schemes.

43 PARTICLE ACCELERATORS↗