Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LASER OUTPUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Effects of various cavity designs on the performance of a CO2 TEA laser with an unstable resonator

Unstable resonator modeling has been carried out for an injection-seeded CO2 transversely excited atmosphere (TEA) laser in the NOAA/ERL/Wave Propagation Laboratory (WPL) Doppler lidar to examine the effects of various cavity designs on the quality of the output beam. The results show the effects of an injection pinhole, electrode spacing, mirror tilt, and radial reflectivity function of the output coupler. The electrode spacing in this laser has negligible effect. The injection pinhole, however, produces complicated structures in the output patterns. If the pinhole is removed, the output pattern is much smoother, and the frequency jitter is smaller. Misalignment sensitivity is very closely related to the radial reflectivity function. The superparabolic function provides the highest coupling efficiency, largest beam size, and good collimation, but produces a slightly higher misalignment sensitivity compared with a parabolic function. The Gaussian function provides the lowest misalignment sensitivity, but it produces the smallest beam size and the largest beam divergence. Also, the coupling coefficient is 50 percent lower than the optimum value. Methods for using a flat diffraction grating in unstable resonators are also investigated. The best way is to use a flat grating/positive lens combination to replace the back concave mirror.

Zhao, Yanzeng↗

Ti:sapphire/KrF hybrid laser system generating trains of subterawatt subpicosecond UV pulses

The GARPUN-MTW Ti:sapphire/KrF hybrid laser system is used to investigate different multipass schemes for amplifying trains of ultrashort pulses (USPs) of subpicosecond duration. It is shown that, for an USP repetition period of 3 – 5 ns, which exceeds the gain-medium recovery time (∼2 ns), trains are amplified in the same way as single USPs. Due to this, a train can efficiently extract pump energy from the amplifier and sum energies of individual USPs. The energy of a four-USP train, extracted during four passes through the preamplifier and two passes through the final KrF amplifier (4 + 2 scheme), is saturated at a level of 1.6 J and corresponds to maximum USP peak powers of about 0.6 TW. The energy of amplified spontaneous emission (ASE), on the contrary, rapidly increases at a large total gain length L{sub eff} ≈ 6 m and is approximately equal to the USP energy. In the (4 + 1) and (2 + 2) schemes the USP energy decreases only slightly, to E{sub out} = 1.3 and 1.2 J, and the ASE fraction is reduced to about 10% and 3%, respectively. USP self-focusing leads to multiple laser beam filamentation and a 200-fold local increase in the radiation intensity in filaments, to ∼2 × 10{sup 11} W cm{sup -2}, a level at which the nonlinear loss in the output CaF{sub 2} windows of the KrF amplifier, caused by three-photon absorption, nonlinear scattering, and broadening of the radiation spectrum to a value exceeding the gain band of the KrF laser transition, becomes the main factor determining the saturation of the USP output energy. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single longitudinal mode operation of semiconductor laser arrays with etalon control

A simple method is devised to obtain a single longitudinal output beam from high-power multilongitudinal mode diode laser arrays. Mode control is achieved by simply placing a thin etalon in front of the laser. The three-cavity laser formed by addition of the etalon favors a single longitudinal mode. This technique is applicable to both continuous wave and pulsed laser modes of operation. Experimental results demonstrating the technique along with future work and possible applications are discussed.

Hemmati, H.↗

The FERMI@Elettra free-electron-laser source for coherent X-ray physics: photon properties, beam transport system, and applications

FERMI@Elettra is comprised of two free electron lasers (FELs) that will generate short pulses (tau ~;; 25 to 200 fs) of highly coherent radiation in the XUV and soft X-ray region. The use of external laser seeding together with a harmonic upshift scheme to obtain short wavelengths will give FERMI@Elettra the capability to produce high quality, longitudinal coherent photon pulses. This capability together with the possibilities of temporal synchronization to external lasers and control of the output photon polarization will open new experimental opportunities not possible with currently available FELs. Here we report on the predicted radiation coherence properties and important configuration details of the photon beam transport system. We discuss the several experimental stations that will be available during initial operations in 2011, and we give a scientific perspective on possible experiments that can exploit the critical parameters of this new light source.

36 MATERIALS SCIENCE↗

Terahertz multiheterodyne spectroscopy using laser frequency combs

The terahertz region is of great importance for spectroscopy since many molecules have absorption fingerprints there. Frequency combs based on terahertz quantum cascade lasers feature broadband coverage and high output powers in a compact package, making them an attractive option for broadband spectroscopy. Here, we demonstrate the first multiheterodyne spectroscopy using two terahertz quantum cascade laser combs. Over a spectral range of 250 GHz, we achieve average signal-to-noise ratios of 34 dB using cryogenic detectors and 24 dB using room-temperature detectors, all in just 100 μs. As a proof of principle, we use these combs to measure the broadband transmission spectrum of etalon samples and show that, with proper signal processing, it is possible to extend the multiheterodyne spectroscopy to quantum cascade laser combs operating in pulsed mode. As a result, this greatly expands the range of quantum cascade lasers that could be suitable for these techniques and allows for the creation of completely solid-state terahertz laser spectrometers.

42 ENGINEERING↗

Application of tunable diode lasers as local oscillators in an Infrared Heterodyne Radiometer (IHR)

The utility of diode lasers as local oscillators (LOs) in a heterodyne receiver application was investigated. The CW power, spectral tunability, spectral stability, and spatial intensity distribution of the TDL outputs were measured. A tunable diode laser LO was incorporated into a laboratory Dicke-switched infrared heterodyne setup and used to measure radiometer sensitivity as well as spectroscopic characteristics of selected absorption lines of ammonia. The test results on one of the two tunable diode lasers are emphasized in an attempt to provide a comprehensive data package which may be useful for future planning purposes. The second tunable diode laser exhibits characteristics similar to the fully tested TDL with the exception that some changes in its performance characteristics as it was temperature cycled between room temperature and the operating temperature of approximately 50K occurred.

Savage, M. G.↗

Nonradiative relaxation and laser action in tunable solid state laser crystals

Room-temperature pulsed laser action was obtained in chromium-activated forsterite (Cr:Mg2SiO4) for both 532 and 1064 nm pumping. Free running laser emission in both cases is centered at 1235 nm and has a bandwidth of approximately 30 nm. Slope efficiency as high as 22 percent was measured. Using different sets of output mirrors and a single birefrigent plate as the intracavity wavelength selecting element tunability over the 1167 to 1268 nm spectral range was demonstrated. Continuous wave laser operation at room temperature was obtained for 1064 nm pumping from a CW Nd:YAG laser. The output power slope efficiency is 6.8 percent. The gain cross section is estimated to be 1.1 x 10 to the 19th sq cm. Spectroscopic studies suggest that the laser action is due to a center other than the trivalent chromium (Cr 3+), presumably the tetravalent chromium (Cr 4+) in a tetrahedrally coordinated site.

Petricevic, V.↗

Nanoscale thermal analysis of InGaAs quantum well based semiconductor disk laser with different pump geometry

Using the finite element method, thermal effects including the maximum temperature, the heat flux and the temperature gradient in the active region of semiconductor disk lasers with front and end pumped geometry are numerically analyzed at the first time. Nanoscale thermal conductivities of the multiple quantum wells and the distributed Bragg reflector are used to overcome the underestimate of the temperature rise which comes from the use of the weighted average of the bulk thermal conductivities in the previous works, and the calculated results are compared with the corresponding experiments. The maximum temperature of quantum wells in active region with end pump is always higher than that with front pump under same pump power. Because of its better mode matching, output powers of the end pumped laser are bigger than that of the front pumped laser when the pump power is relatively lower and the thermal rollover of laser has not happened. In comparison, the front pumped laser can tolerate much bigger pump power and produce much higher output power thanks to its better heat dissipation.

36 MATERIALS SCIENCE↗

Instantaneous velocity field imaging instrument for supersonic reacting flows

The technical tasks conducted to develop and demonstrate a new gas velocity measurement technique for high enthalpy reacting flows is described. The technique is based on Doppler-shifted Planar Laser-induced Fluorescence (PLIF) imaging of the OH radical. The imaging approach permits, in principle, single-shot measurements of the 2-D distribution of a single velocity component in the measurement plane, and is thus a technique of choice for applications in high enthalpy transient flow facilities. In contrast to previous work in this area, the present program demonstrated an approach which modified the diagnostic technique to function under the constraints of practical flow conditions of engineering interest, rather than vice-versa. In order to accomplish the experimental demonstrations, the state-of-the-art in PLIF diagnostic techniques was advanced in several ways. Each of these tasks is described in detail and is intended to serve as a reference in supporting the transition of this new capability to the fielded PLIF instruments now installed at several national test facilities. Among the new results of general interest in LlF-based flow diagnostics, a detailed set of the first measurements of the collisional broadening and shifting behavior of OH (1,0) band transitions in H7-air combustion environments is included. Such measurements are critical in the design of a successful strategy for PLIF velocity imaging; they also relate to accurate concentration and temperature measurements, particularly in compressible flow regimes. Furthermore, the results shed new light on the fundamental relationship between broadening and energy transfer collisions in OH A(sup 2)Sigma(+)v(sup ') = 1. The first single-pulse, spectrally-resolved measurements of the output of common pulsed dye lasers were also produced during the course of this effort. As with the OH broadening measurements, these data are a significant aspect of a successful velocity imaging strategy, and also have potential implications for many other LIF measurement techniques. Our results indicated the need to modify the commercially available laser cavity in order to accommodate the constraints imposed by typical SCRAMJET combustion characteristics as well as to increase the instrument's velocity dynamic range to span an intra-image range in excess of 2 km/s. The various technical efforts were brought together in a series of experiments demonstrating the applicability of the technique in a high pressure, high temperature H2-air combustion system. The resultant images were compared with 2-D flow simulations in order to determine the accuracy of the instrument. Mean velocity imaging in flows with an axis of symmetry was demonstrated with an accuracy of +/- 50 m/s out of an intra-image dynamic range of 1600 m/s, including reversed flow. A more complex configuration amenable to single-shot imaging in flows without an axis of symmetry was also demonstrated. Limitations imposed by available equipment resulted in an accuracy of about +/- 200 m/s out of 1750 m/s in these demonstrations. Minor modifications to the present configuration were suggested to improve this performance. Each technical task is described in detail, along with significance of the results for the overall imaging velocimeter configuration. This report should allow the user community to integrate this new measurement capability in their existing instrumentation platforms.

Allen, M. G.↗

Obtaining single-cycle pulses from a mode-locked laser

In all existing mode-locked lasers, the ultimate limit on the output pulse duration is set by the bandwidth of the gain medium. Yet the technique of coherent mode locking allows one to generate broadband pulses from a laser with a linearly narrowband active medium by exploiting the coherent properties of the amplifier. In this work we numerically demonstrate how to use this technique for the generation of single-cycle pulses directly from a mode-locked oscillator.

74 ATOMIC AND MOLECULAR PHYSICS↗

The application of laser induced predissociation fluorescence to the measurement of vibrational temperatures in a shock layer flow

Single shot spatially and spectrally resolved laser induced predissociation fluorescence measurements in a shock layer around a cylinder in a pulsed supersonic free stream are presented. Fluorescence signals were produced using the tuned output of an argon fluoride excimer laser to excite a mixture of rovibrational transitions in molecular oxygen. The signals produced along a line inside the shock layer were focussed onto a two dimensional detector coupled to a spectrometer, thus allowing spectral and spatial resolution of the fluorescence. In this way, it was possible to detect two fluorescence signals from two different transitions simultaneously, allowing the determination of vibrational temperatures without the need for calibration. However, to minimize problems associated with low signal to noise ratios, background subtraction and spatial averaging was required. The experimental measurements are compared with theoretical inviscid shock layer calculations for nonequilibrium air. A description of the strategies employed in these calculations is also provided.

Sutton, D. J.↗

Criteria for the evaluation of laser solar energy converter systems

Assuming that a parabolic insolation-collection mirror-based solar pumped laser has a collector and heat emitter whose weights are proportional to their areas, and that the weight of the laser is negligible by comparison, the output power/unit weight can be expressed in terms of the efficiencies and working temperatures of the system. This ratio appears to be several times higher for an IBr laser than for one operating on C3F7I, because the solar utilization efficiency is greater for the former despite its lower working temperature.

Harries, W. L.↗

Monolithic, unidirectional single-mode Nd:YAG ring laser

A new solid-state laser has been designed which achieves high single-mode output power by using a unidirectional nonplanar resonator constructed from a single Nd:YAG crystal. When placed in a magnetic field, the laser provides a pump-limited, single-axial-mode output of 163 mW at 1064 nm. The laser has been specifically developed as an oscillator for a long-range coherent Doppler anemometer. Other applications include coherent communications, coherent optical radar, and inertial rotation sensing.

Kane, T. J.↗

Effect of argon on the performance of a fast-axial flow CO{sub 2} laser

The performance characteristics of a fast-axial flow (FAF) cw CO{sub 2} laser are described. The dependences of the output power, efficiency, and discharge voltage on the discharge current of a FAF cw CO{sub 2} laser with optimised composition of the CO{sub 2}:N2:He=1:4.4:7.6 gas mixture with a small amount of argon are studied experimentally at two pressures of 50 and 60 mbar in open and closed cycle regimes of the laser system. (lasers)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Grating rhomb diode laser power combiner

A compact device for spectrally combining many laser-diode beams into a single multi-wavelength beam has been developed for use in NASA's intersatellite communications programs. The prototype device combines seven 30 milliwatt beams into a single beam with 70 percent efficiency producing an output of approximately 150 milliwatts. All beams are coaxial and can be collimated with a single transmitter optical system. The combining technique is relatively insensitive to drifts in the laser-diode wavelength and provides both increased power output and laser-diode source redundancy. Combination of more than 100 laser-diodes producing an output greater than 5 watts appears feasible with this technique.

Minott, Peter O.↗

Parametric generation in a PPLN crystal pumped by a Q-switched mode-locked Nd : YAG laser: comparison of the superluminescent and singly resonant operation regimes

The output characteristics of light in two parametric generation regimes [parametric superluminescence and parametric generation in a singly resonant optical parametric oscillator (OPO) based on a 50-mm long PPLN crystal, synchronously pumped by a 50-ps Nd : YAG laser] are compared. The total average output power at the wavelengths of signal (λ = 1475 nm) and idler (λ = 3820 nm) waves in the superluminescence regime is ∼120 mW (peak power ∼120 kW). The maximum total conversion efficiency with respect to the absorbed power in the superluminescence regime is ∼60%. The maximum conversion efficiency into the idler wave with respect to the absorbed pump power is 15% and 25% (quantum efficiencies of 54% and 90%) for the superluminescence and singly resonant OPO regimes, respectively. The maximum values of the average output power at the idler wavelength are ∼30 and ∼60 mW at degrees of pump depletion of 47% and 55% for the superluminescence and singly resonant OPO regimes, respectively. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Demonstration of frequency control and CW diode laser injection control of a titanium-doped sapphire ring laser with no internal optical elements

Theoretical and experimental frequency narrowing studies of a Ti:sapphire ring laser with no intracavity optical elements are reported. Frequency narrowing has been achieved using a birefringent filter between a partially reflecting reverse wave suppressor mirror and the ring cavity output mirror. Results of CW diode laser injection seeding are reported.

Bair, Clayton H.↗

Laterally coupled distributed feedback type-I quantum well cascade diode lasers emitting near 3.22 μm

The laterally coupled distributed feedback (LC-DFB) GaSb-based type-I quantum well cascade diode lasers using the second- and the sixth-order gratings to stabilize the output spectrum near 3.22 μm were designed and fabricated in this paper. The laser heterostructure contained three cascades. The devices were manufactured using a single dry etching step defining the ~5-μm-wide ridge with ~5-μm-wide gratings sections adjacent to the ridge sides. The grating coupling coefficients were estimated to be about 1 cm -1 . The stability of the single-frequency operation was ensured by alignment of the DFB mode to the relatively wide gain peak. The 2-mm-long second-order LC-DFB lasers generated above 10 mW of continuous-wave (CW) output power at 20°C in epi-side-up configuration and demonstrated power conversion efficiency above 2%. The sixth-order LC-DFB lasers showed lower efficiency but still generated several milliwatts of CW output power. Finally, the devices demonstrated a CW current tuning range of about 3.5 nm at the temperature of 20°C.

36 MATERIALS SCIENCE↗