Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Infrared techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Temperature control of silica mirrors for cryogenically-cooled telescopes in space

The SIRTF (Space Infrared Telescope Facility) optical subsystem, including the primary mirror, has been modeled using lumped-parameter techniques and a thermal and cryogenic transient analysis program developed previously. Since silica mirrors have been shown to have significantly less distortion due to cryogenic cooldown, a silica primary mirror of approximately 1 m diameter is being considered. Thermal responses to variations in aperture heat load and heat sink temperature have been explored. Calculations have been made of system noise components from primary mirror spatial and temporal temperature variations. Background-limited infrared observations can be made at wavelengths out to 200 micrometers. Mirror thermal performance with and without copper wires for cooling is also considered.

Melugin, R. K.↗

Infrared upconversion for astronomy

The basic theory of upconversion is presented, along with a brief historical summary of upconversion techniques. Upconverters were used in astronomical studies, but have met with only modest success. Upconversion will become a useful detection method for astronomy only if substantial but perhaps forseeable, improvements can be realized.

Boyd, R. W.↗

Preliminary study of temperature measurement techniques for Stirling engine reciprocating seals

Methods of determining the contact surface temperature in reciprocating seals are investigated. Direct infrared measurement of surface temperatures of a rod exiting a loaded cap seal or simulated seal are compared with surface thermocouple measurements. Significant cooling of the surface requires several milliseconds so that exit temperatures may be considered representative of internal contact temperatures.

Wilcock, D. F.↗

Precision Lower Stratospheric Temperature Monitoring with the MSU: Technique, Validation, and Results, 1979-1991

Microwave Sounding Unit channel 4 data from the TIROS-N (Television and Infrared Operational Satellite)-N series of NOAA (National Oceanic and Atmospheric Administration) satellites are intercalibrated to provide a continuous global record of deep-layer averaged lower stratospheric temperatures during 1979-1991. A 13-year record of temperature anomalies is time averaged into pentads and months on a 2.5 deg. grid. The monthly gridpoint anomalies are validated with ten years of radiosonde data during 1979-88. The calibration stability of each satellite's measurements is evaluated during satellite overlap periods, the longest of which reveal no measurable instrumental drift at the level of 0.01 C yr (exp -1). Intercomparisons between NOAA-6 and NOAA- 7 anomalies indicate monthly gridpoint precision of 0.05 C in the tropics to around 0.10 C in the extratropics, and signal-to-noise ratios precision and stability statistics are much better than have been previously reported by other investigators for MSU channel 4. Pentad precision is about 0.10 C in the tropics to around 0.25 C at high latitudes and signal-to- noise ratios generally over 250 in the tropics and high latitudes, but 100-200 in the middle latitudes. Radiosonde comparisons to the monthly gridpoint anomalies have correlations ranging from 0.90 in the tropics (where the interannual variability is smallest) to as high as 0.99 at high-latitude stations. The corresponding standard error of estimate is generally around 0.3 C. A significant difference in decadal trends is found between the satellite and radiosonde systems, with a step change of 0.21 C (sondes cooler) compared to the satellite measurements. Investigations of the possible sources of the discrepancy lead us to suspect that the gradual transition from on-site calibration of sondes with thermometers to factory calibration of sondes around 1982 might have caused a change in the calibration, although this conclusion must be viewed as tentative. The largest globally averaged temperature variations during 1979-91 occur after the El Chichon (1982) and Pinatubo (1991) volcanic eruptions. These warm events are superimposed upon a net downward trend in temperatures during the period. This cooling trend has more of a step function than linear character, with the step occurring during the El Chichon warm event. It is strongest in polar regions and the Northern Hemisphere middle latitudes. These characteristics are qualitatively consistent with radiative adjustments expected to occur with observed ozone depletions.

Spencer, Roy W.↗

Polycyclic Aromatic Hydrocarbons and Infrared Astrophysics with Spitzer

Over the past fifteen years, thanks to significant, parallel advancements in observational, experimental, and theoretical techniques, tremendous strides have been made in our understanding of the role that carbon-rich plays in the interstellar medium (ISM). Twenty years ago, the possible existence of an abundant population of large, carbon-rich molecules in the ISM was unthinkable. Today, the unmistakable spectroscopic signatures of polycyclic aromatic hydrocarbons (PAHs) - shockingly large molecules by the standards of traditional interstellar chemistry -are recognized throughout the Universe. In this presentation, we will examine the current state of the interstellar PAH model and explore how this data, in conjunction with the unparalleled observational data provided by the Spitzer Space Telescope, can be used to draw ever-deeper insights into the physical and chemical natures of a wide range of astrophysical environments.

Hudgins, Douglas M.↗

Derivation of Tropospheric Column Ozone from the EPTOMS/GOES Co-Located Data Sets using the Cloud Slicing Technique

A recently developed technique called cloud slicing used for deriving upper tropospheric ozone from the Nimbus 7 Total Ozone Mapping Spectrometer (TOMS) instrument combined together with temperature-humidity and infrared radiometer (THIR) is no longer applicable to the Earth Probe TOMS (EPTOMS) because EPTOMS does not have an instrument to measure cloud top temperatures. For continuing monitoring of tropospheric ozone between 200-500hPa and testing the feasibility of this technique across spacecrafts, EPTOMS data are co-located in time and space with the Geostationary Operational Environmental Satellite (GOES)-8 infrared data for 2001 and early 2002, covering most of North and South America (45S-45N and 120W-30W). The maximum column amounts for the mid-latitudinal sites of the northern hemisphere are found in the March-May season. For the mid-latitudinal sites of the southern hemisphere, the highest column amounts are found in the September-November season, although overall seasonal variability is smaller than those of the northern hemisphere. The tropical sites show the weakest seasonal variability compared to higher latitudes. The derived results for selected sites are cross validated qualitatively with the seasonality of ozonesonde observations and the results from THIR analyses over the 1979-1984 time period due to the lack of available ozonesonde measurements to study sites for 2001. These comparisons show a reasonably good agreement among THIR, ozonesonde observations, and cloud slicing-derived column ozone. With very limited co-located EPTOMS/GOES data sets, the cloud slicing technique is still viable to derive the upper tropospheric column ozone. Two new variant approaches, High-Low (HL) cloud slicing and ozone profile derivation from cloud slicing are introduced to estimate column ozone amounts using the entire cloud information in the troposphere.

Ahn, C.↗

Near-infrared mapping spectrometer optical subsystem development and testing

The Near-Infrared Mapping Spectrometer (NIMS) is one of the four remote-sensing science instruments of the Galileo Orbiter scientific payload. The NIMS scientific objectives require operating the detector and optical subsystem at cryogenic temperatures. The necessity of assembling, aligning, and testing the optics at room temperature and meeting design specifications at the cryogenic operating temperature (130 K) presented a set of challenging technical problems. A systematic approach to the development of athermalized mounts and supporting structures for optical components is described. A technique utilizing the visible spectral range and supplementary ray-trace information for alignment of an infrared instrument is presented. The optical subsystem point-spread function and spatial and spectral resolution were determined at room temperature using selected spectral and spatial targets. Based on thermal-distortion analyses of the structure and mounts, compensators were selected, implemented, and verified at cryogenic temperatures. The selection of the compensator and the overall system performance were verified in a thermal vacuum chamber. Various external and internal calibration targets were used.

Macenka, S. A.↗

Ultrasensitive detection of atmospheric trace gases using frequency modulation spectroscopy

Frequency modulation (FM) spectroscopy is a new technique that promises to significantly extend the state-of-the-art in point detection of atmospheric trace gases. FM spectroscopy is essentially a balanced bridge optical heterodyne approach in which a small optical absorption or dispersion from an atomic or molecular species of interest generates an easily detected radio frequency (RF) signal. This signal can be monitored using standard RF signal processing techniques and is, in principle, limited only by the shot noise generated in the photodetector by the laser source employed. The use of very high modulation frequencies which exceed the spectral width of the probed absorption line distinguishes this technique from the well-known derivative spectroscopy which makes use of low (kHz) modulation frequencies. FM spectroscopy was recently extended to the 10 micron infrared (IR) spectral region where numerous polyatomic molecules exhibit characteristic vibrational-rotational bands. In conjunction with tunable semiconductor diode lasers, the quantum-noise-limited sensitivity of the technique should allow for the detection of absorptions as small as .00000001 in the IR spectral region. This sensitivity would allow for the detection of H2O2 at concentrations as low as 1 pptv with an integration time of 10 seconds.

Cooper, David E.↗

Thermal Nondestructive Characterization of Corrosion in Boiler Tubes by Application fo a Moving Line Heat Source

Wall thinning in utility boiler waterwall tubing is a significant inspection concern for boiler operators. Historically, conventional ultrasonics has been used lor inspection of these tubes. This technique has proved to be very labor intensive and slow. This has resulted in a "spot check" approach to inspections, making thickness measurements over a relatively small percentage of the total boiler wall area. NASA Langley Research Center has developed a thermal NDE technique designed to image and quantitatively characterize the amount of material thinning present in steel tubing. The technique involves the movement of a thermal line source across the outer surface of the tubing followed by an infrared imager at a fixed distance behind the line source. Quantitative images of the material loss due to corrosion are reconstructed from measurements of the induced surface temperature variations. This paper will present a discussion of the development of the thermal imaging system as well as the techniques used to reconstruct images of flaws. The application of the thermal line source, coupled with this analysis technique, represents a significant improvement in the inspection speed for large structures such as boiler waterwalls while still providing high-resolution thickness measurements. A theoretical basis for the technique will be presented thus demonstrating the quantitative nature of the technique. Further, results of laboratory experiments on flat Panel specimens with fabricated material loss regions will be presented.

Cramer, K. Elliott↗

Boiler Tube Corrosion Characterization with a Scanning Thermal Line

Wall thinning due to corrosion in utility boiler water wall tubing is a significant operational concern for boiler operators. Historically, conventional ultrasonics has been used for inspection of these tubes. Unfortunately, ultrasonic inspection is very manpower intense and slow. Therefore, thickness measurements are typically taken over a relatively small percentage of the total boiler wall and statistical analysis is used to determine the overall condition of the boiler tubing. Other inspection techniques, such as electromagnetic acoustic transducer (EMAT), have recently been evaluated, however they provide only a qualitative evaluation - identifying areas or spots where corrosion has significantly reduced the wall thickness. NASA Langley Research Center, in cooperation with ThermTech Services, has developed a thermal NDE technique designed to quantitatively measure the wall thickness and thus determine the amount of material thinning present in steel boiler tubing. The technique involves the movement of a thermal line source across the outer surface of the tubing followed by an infrared imager at a fixed distance behind the line source. Quantitative images of the material loss due to corrosion are reconstructed from measurements of the induced surface temperature variations. This paper will present a discussion of the development of the thermal imaging system as well as the techniques used to reconstruct images of flaws. The application of the thermal line source coupled with the analysis technique represents a significant improvement in the inspection speed and accuracy for large structures such as boiler water walls. A theoretical basis for the technique will be presented to establish the quantitative nature of the technique. Further, a dynamic calibration system will be presented for the technique that allows the extraction of thickness information from the temperature data. Additionally, the results of the application of this technology to actual water wall tubing samples and in-situ inspections will be presented.

Cramer, K. Elliott↗

Thermographic Imaging of Material Loss in Boiler Water-Wall Tubing by Application of Scanning Line Source

Localized wall thinning due to corrosion in utility boiler water-wall tubing is a significant inspection concern for boiler operators. Historically, conventional ultrasonics has been used for inspection of these tubes. This technique has proven to be very manpower and time intensive. This has resulted in a spot check approach to inspections, documenting thickness measurements over a relatively small percentage of the total boiler wall area. NASA Langley Research Center has developed a thermal NDE technique designed to image and quantitatively characterize the amount of material thinning present in steel tubing. The technique involves the movement of a thermal line source across the outer surface of the tubing followed by an infrared imager at a fixed distance behind the line source. Quantitative images of the material loss due to corrosion are reconstructed from measurements of the induced surface temperature variations. This paper will present a discussion of the development of the thermal imaging system as well as the techniques used to reconstruct images of flaws. The application of the thermal line source coupled with the analysis technique represents a significant improvement in the inspection speed for large structures such as boiler water-walls. A theoretical basis for the technique will be presented which explains the quantitative nature of the technique. Further, a dynamic calibration system will be presented for the technique that allows the extraction of thickness information from the temperature data. Additionally, the results of applying this technology to actual water-wall tubing samples and in situ inspections will be presented.

Cramer, K. Elliott↗

Stennis Space Center Verification & Validation Capabilities

Scientists within NASA#s Applied Research & Technology Project Office (formerly the Applied Sciences Directorate) have developed a well-characterized remote sensing Verification & Validation (V&V) site at the John C. Stennis Space Center (SSC). This site enables the in-flight characterization of satellite and airborne high spatial resolution remote sensing systems and their products. The smaller scale of the newer high resolution remote sensing systems allows scientists to characterize geometric, spatial, and radiometric data properties using a single V&V site. The targets and techniques used to characterize data from these newer systems can differ significantly from the techniques used to characterize data from the earlier, coarser spatial resolution systems. Scientists have used the SSC V&V site to characterize thermal infrared systems. Enhancements are being considered to characterize active lidar systems. SSC employs geodetic targets, edge targets, radiometric tarps, atmospheric monitoring equipment, and thermal calibration ponds to characterize remote sensing data products. Similar techniques are used to characterize moderate spatial resolution sensing systems at selected nearby locations. The SSC Instrument Validation Lab is a key component of the V&V capability and is used to calibrate field instrumentation and to provide National Institute of Standards and Technology traceability. This poster presents a description of the SSC characterization capabilities and examples of calibration data.

Pagnutti, Mary↗

Application of Long-Path Gas Cell Assisted Infrared Spectroscopy for Detection of Lunar Volatiles and Advanced Curation Efforts

The motivation behind analyzing gaseous samples from the Permanently Shadowed Regions (PSRs) on the lunar surface is built upon the volatiles observed during the LCROSS mission. Advanced curation techniques under cold conditions are essential to the critical scientific analysis of these returned samples. The detection of various volatiles in returned samples by gas-phase infrared (IR) spectroscopy is known to be a powerful tool to understand the resources present in planetary bodies and Astro-materials. The identification and quantification of volatile compounds in returned planetary samples and regolith simulants by advanced and custom-built analytical devices are areas of primary research interest in our group and the Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility. In this context, we discuss recent advancements and experimental results for quick analysis of the major volatiles detected by the LCROSS (water, CO 2 , CH 3 OH, and NH 3 ) by a long-path gas cell/FTIR (Fourier Transform Infrared) spectrometer system. The applicability of this system is demonstrated by qualitative analysis of a series of volatiles measured individually. In addition, the linear dependence of absorption intensity on headspace sample volumes was checked by measuring gas-phase IR absorption spectra of increasing volumes of pure CO 2 gas aliquots. Finally, the instrument performance was evaluated by measuring the relative concentration of NH 3 (g) in methanol solution.

Curation↗

Indium antimonide infrared CCD linear imaging arrays with on-chip preprocessing

A description is presented of the fabrication of a new InSb CCD chip based on an improved process which eliminates the limitations inherent with the earlier techniques. This process includes planar junction formation and an aluminum and SiO2 material system which is amenable to state-of-the-art chemical and plasma delineation techniques. Further, the new chip integrates for the first time in monolithic format InSb IR detectors with an InSb CCD. The reported experiments represent the first operation of an InSb infrared CCD array. In addition to fuller characterization of the 20-element charge-coupled infrared imaging device, several factors which influence device performance are currently being addressed. These include surface state density, the CCD output circuit, and storage time (dark current).

Thom, R. D.↗

Diurnal variability of regional cloud radiative parameters from geostationary satellite data

In the discussed study, Geostationary Operational Environmental Satellite visible and infrared brightness measurements are used to infer regional cloud cover and several associated radiative parameters on an hourly basis. Several techniques are utilized to derive the parameters of interest. These parameters include the areal cloud fraction, cloud-atmosphere albedo, surface-atmosphere albedo, and equivalent blackbody surface and cloud-top temperatures. Attention is given to clear radiance temperature determinations, surface temperature modeling, the infrared threshold method, narrowband-broadband correlations, and albedo determination. Monthly mean values were computed for each parameter as a function of local time. Cloud amounts and temperatures are considered along with longwave emission and shortwave albedo, and composite results.

Minnis, P.↗

Image Simulator for the Wide-Field Infrared Explorer

The Wide-Field Infrared Explorer (WIRE) is a cryogenically-cooled spaceborne telescope designed to study the evolution of starburst galaxies...We describe the design and implementation of the simulator, with particular emphasis on the generation of point-spread functions. The simulator is written in C for use on Unix workstations, and we assess its performance. Sample raw and combined images are displayed, and the image processing steps are outlined. The uses of the simulator to verify that mission requirements are met, to optimize observing strategy, and to test data analysis techniques are also described.

infrared↗

Advances in measuring techniques for turbine cooling test rigs

Surface temperature distribution measurements for turbine vanes and blades were obtained by measuring the infrared energy emitted by the airfoil. The IR distribution can be related to temperature distribution by suitable calibration methods and the data presented in the form of isotherm maps. Both IR photographic and real time electro-optical methods are being investigated. The methods can be adapted to rotating as well as stationary targets, and both methods can utilize computer processing. Pressure measurements on rotating components are made with a rotating system incorporating 10 miniature transducers. A mercury wetted slip ring assembly was used to supply excitation power and as a signal transfer device. The system was successfully tested up to speeds of 9000 rpm and is now being adapted to measure rotating blade airflow quantities in a spin rig and a research engine.

Pollack, F. G.↗