Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMAGES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

High-speed synchrotron X-ray imaging of directed energy deposition of titanium: effects of processing parameters on the formation of entrapped-gas pores

Laser based directed energy deposition (DED) is a competitive method for repairing and remanufacturing metallic parts used in numerous industries including aerospace and biomedical. However, the numerous dynamic phenomena associated with the DED process often result in defects such as entrapped-gas pores, lack of fusion, and undesirable anisotropic properties. The entrapped-gas pore, being one of the most common issues, not only influences melt-pool dynamics but also reduces the fabrication quality and mechanical properties of parts fabricated by the DED process. To reduce and further understand this issue, the real-time observation of the pore formation process needs to be studied first. To directly observe the phenomena in the melt pool, high-speed techniques are needed because rapid solidification leads to rapid pore formation and movement. In-situ high-speed X-ray has been proven to be an effective method in investigating the melt pool dynamics and pore formation mechanisms in the laser powder bed fusion process, in which the fabrication process is quite different from that in DED. Here, the high-speed X-ray method is extended to study the formation of entrapped-gas pores. The real-time formation and quantitative analysis of pores under each set of processing parameters (particle velocity, laser power, and spot welding dwelling time of stationary laser) in the DED process are investigated. We found that the DED with a higher particle velocity (3.19 m/s) produced a smaller average pore size of 27.8 µm and a lower pore area fraction of 0.52%. The DED under lower laser power (156 W) generated a smaller average pore size of 20.3 µm and a lower pore area fraction of 1.94%. The shorter dwelling time (10 ms) benefited the decrease of both average pore size and pore area fraction.

Defect↗

A split imaging spectrometer for temporally and spatially resolved titanium absorption spectroscopy

We present a temporally and a spatially resolved spectrometer for titanium x-ray absorption spectroscopy along 2 axial symmetric lines-of-sight. Each line-of-sight of the instrument uses an elliptical crystal to acquire both the 2p and 3p Ti absorption lines on a single, time gated channel of the instrument. The 2 axial symmetric lines-of-sight allow the 2p and 3p absorption features to be measured through the same point in space using both channels of the instrument. The spatially dependent material temperature can be inferred by observing the 2p and the 3p Ti absorption features. The data are recorded on a two strip framing camera with each strip collecting data from a single line-of-sight. The design is compatible for use at both the OMEGA laser and the National Ignition Facility. The spectrometer is intended to measure the material temperature behind a Marshak wave in a radiatively driven SiO{sub 2} foam with a Ti foam tracer. In this configuration, a broad band CsI backlighter will be used for a source and the Ti absorption spectrum measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass-ablation-rate measurements in direct-drive cryogenic implosions using x-ray self-emission images

A technique to measure the mass ablation rate in direct-drive inertial confinement fusion implosions using a pinhole x-ray framing camera is presented. In target designs consisting of two layers of different materials, two x-ray self-emission peaks from the coronal plasma were measured once the laser burned through the higher-Z outer layer. The location of the inner peak is related to the position of the ablation front and the location of the outer peak corresponds to the position of the interface of the two layers in the plasma. The emergence of the second peak was used to measure the burnthrough time of the outer layer, giving the average mass ablation rate of the material and instantaneous mass remaining. By varying the thickness of the outer layer, the mass ablation rate can be obtained as a function of time. Simulations were used to validate the methods and verify that the measurement techniques are not sensitive to perturbation growth at the ablation surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heat flux estimates of power balance on Proto-MPEX with IR imaging

The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) at Oak Ridge National Laboratory (ORNL) is a precursor linear plasma device to the Material Plasma Exposure eXperiment (MPEX), which will study plasma material interactions (PMIs) for future fusion reactors. This paper will discuss the initial steps performed towards completing a power balance on Proto-MPEX to quantify where energy is lost from the plasma, including the relevant diagnostic package implemented. Machine operating parameters that will improve Proto-MPEX’s performance may be identified, increasing its PMI research capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Imaging Detector Readout Circuits with In-Pixel ADCs for Fourier Transform Imaging Spectrometers

Focal plane arrays (FPAs) with high frame rates and many pixels benefit several upcoming Earth science missions including GEO-CAPE, GACM, and ACE by enabling broader spatial coverage and higher spectral resolution. FPAs for the PanFTS, a high spatial resolution Fourier transform spectrometer and a candidate instrument for the GEO-CAPE mission are the focus of the developments reported here, but this FPA technology has the potential to enable a variety of future measurements and instruments. The ESTO ACT Program funded the developed of a fast readout integrated circuit (ROIC) based on an innovative in-pixel analog-to-digital converter (ADC). The 128 X 128 pixel ROIC features 60 ?m pixels, a 14-bit ADC in each pixel and operates at a continuous frame rate of 14 kHz consuming only 1.1 W of power. The ROIC outputs digitized data completely eliminating the bulky, power consuming signal chains needed by conventional FPAs. The 128 X 128 pixel ROIC has been fabricated in CMOS and tested at the Jet Propulsion Laboratory. The current version is designed to be hybridized with PIN photodiode arrays via indium bump bonding for light detection in the visible and ultraviolet spectral regions. However, the ROIC design incorporates a small photodiode in each cell to permit detailed characterization of the ROICperformance without the need for hybridization. We will describe the essential features of the ROIC design and present results of ROIC performance measurements.

focal plane arrays (FPAs)↗

Micro-Spectroscopic Imaging and Characterization of Individually Identified Ice Nucleating Particles from a Case Field Study

The effect of anthropogenic and biogenic organic particles on atmospheric glaciation processes is poorly understood. We use an optical microscopy (OM) setup to identify the location of ice nuclei (IN) active in immersion freezing and deposition ice nucleation for temperatures of 200-273 K within a large population of particles sampled from an ambient environment. Applying multi-modal micro-spectroscopy methods we characterize the physicochemical properties of individual IN in particle populations collected in central California. Chemical composition and mixing state analysis of particle populations are performed to identify characteristic particle-type classes. All particle-types contained organic material. Particles in these samples take up water at subsaturated conditions, induce immersion freezing at subsaturated and saturated conditions above 226 K, and act as deposition IN below 226 K. The identified IN belong to the most common particle-type classes observed in the field samples: organic coated sea salt, Na-rich, and secondary and refractory carbonaceous particles. Based on these observations, we suggest that the IN are not always particles with unique chemical composition and exceptional ice nucleation propensity; rather, they are common particles in the ambient particle population. Thus, particle composition and morphology alone are insufficient to assess their potential to act as IN. The results suggest that particle-type abundance is also a crucial factor in determining the ice nucleation efficiency of specific IN types. These findings emphasize that ubiquitous organic particles can induce ice nucleation under atmospherically relevant conditions and that they may play an important role in atmospheric glaciation processes.

Environmental Molecular Sciences Laboratory↗