Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hourly Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

A Climatology of Midlatitude Continental Clouds from the ARM SGP Site: Low-Level Cloud Macrophysical, Microphysical, and Radiative Properties - Part I

A record of single-layer and overcast low cloud (stratus) properties has been generated using approximately 4000 hours of data collected from January 1997 to December 2002 at the Atmospheric Radiation Measurement (ARM) Southern Great Plains Central Facility (SCF). The cloud properties include liquid-phase and liquid-dominant, mixed-phase, low cloud macrophysical, microphysical, and radiative properties including cloud-base and -top heights and temperatures, and cloud physical thickness derived from a ground-based radar and lidar pair, and rawinsonde sounding; cloud liquid water path (LWP) and content (LWC), and cloud-droplet effective radius (r(sub e)) and number concentration (N) derived from the macrophysical properties and radiometer data; and cloud optical depth (tau), effective solar transmission (gamma), and cloud/top-of-atmosphere albedos (R(sub cldy)/R(sub TOA)) derived from Eppley precision spectral pyranometer measurements. The cloud properties were analyzed in terms of their seasonal, monthly, and hourly variations. In general, more stratus clouds occur during winter and spring than in summer. Cloud-layer altitudes and physical thicknesses were higher and greater in summer than in winter with averaged physical thicknesses of 0.85 km and 0.73 km for day and night, respectively. The seasonal variations of LWP, LWC, N. tau, R(sub cldy), and R(sub TOA) basically follow the same pattern with maxima and minima during winter and summer, respectively. There is no significant variation in mean r(sub e), however, despite a summertime peak in aerosol loading, Although a considerable degree of variability exists, the 6-yr average values of LWP, LWC, r(sub e), N, tau, gamma, R(sub cldy) and R(sub TOA) are 150 gm(exp -2) (138), 0.245 gm(exp -3) (0.268), 8.7 micrometers (8.5), 213 cm(exp -3) (238), 26.8 (24.8), 0.331, 0.672, 0.563 for daytime (nighttime). A new conceptual model of midlatitude continental low clouds at the ARM SGP site has been developed from this study. The low stratus cloud amount monotonically increases from midnight to early morning (0930 LT), and remains large until around local noon, then declines until 1930 LT when it levels off for the remainder of the night. In the morning, the stratus cloud layer is low, warm, and thick with less LWC, while in the afternoon it is high, cold, and thin with more LWC. Future parts of this series will consider other cloud types and cloud radiative forcing at the ARM SCF.

Dong, Xiquan↗

Cryogenic Orbital Testbed (CRYOTE) Ground Test Article, Final Report

Liquid propulsion has been used since Robert Goddard started developing a liquid oxygen (LO2) and gasoline powered rocket and fired it in 1923 (Ref. 1). In the following decades engineers settled on the combination of liquid hydrogen (LH2) and LO2 as the most efficient propellant combination for in-space travel. Due to their low temperatures (LH2 at 20 K and LO2 at 90 K), they require special handling and procedures. General Dynamics began developing LO2 and LH2 upper stages in 1956 in the form of Centaur, these efforts were soon funded by the Department of Defense in conjunction with NASA (beginning in 1958) (Ref. 2). Meanwhile NASA also worked with McDonnell Douglas to develop the SIV-B stage for the Saturn V rocket. In the subsequent years, the engineers were able to push the Centaur to up to 9 hr of orbital lifetime and the SIV-B to up to 6 hr. Due to venting the resultant boil-off from the high heat loads through the foam insulation on the upper stages, both vehicles remained in a settled configuration throughout the flights, thus the two phases of propellant (liquid and vapor) were separated at a known location. The one exception to this were the Titan/Centaur missions, which thanks to the lower boil-off using three layers of multilayer insulation (MLI), were able to coast unsettled for up to 5.25 hr during direct geosynchronous orbit insertion missions. In the years since there has been a continuous effort to extend the life of these upper stages from hours to days or even months.

Joule-Thompson Effect↗

PYSAT: Python Satellite Data Analysis Toolkit

A common problem in space science data analysis is combining complementary data sources that are provided and analyzed in different formats and programming languages. The Python Satellite Data Analysis Toolkit (pysat) addresses this issue by providing an open source toolkit that implements the general process of space science data analysis, from beginning to end, in an instrumentindependent manner. This toolkit uses an Instrument object that enables systematic analysis of science data from a variety of platforms within a single interface. Basic functions such as downloading, loading, and cleaning are included for all supported instruments. Common analysis routines are also included, which are instrument and data source independent. A nanokernel is used to provide instrument independence, it is attached to the Instrument object and mediates the systematic and arbitrary modification of loaded data. Pysat uses the nanokernel to improve the rigor of time series analysis, support onthefly orbit determination, and cleanly span file breaks. Pysat's functions and higherlevel scientific analysis features are validated through the use of unit testing. Further adoption by the community provides a set of scientific results produced by a common core, constituting a distributed heritage that supports the validity of the underlying processing and scientific output. These features are used to demonstrate consistency between derived electron density profiles and measured ion drifts, particularly downward ion drifts in the afternoon hours during extreme solar minimum. Pysat builds upon open source Python software that is freely available and encourages communitydriven development.

Stoneback, R.A.↗

Substorms At Jupiter: Galileo Observations of Transient Reconnection in The Near Tail

The magnetic flux content of the Jovian magnetosphere is set by the internal dynamo, but those magnetic field lines are constantly being loaded by heavy ions at the orbit of lo and dragged inexorably outward by the centrifugal force. Vasyliunas has proposed a steady state reconnecting magnetospheric model that sheds plasma islands of zero net magnetic flux and returns nearly empty flux tubes to the inner magnetosphere. The Galileo observations indicate that beyond 40 Rj the current sheet begins to tear and beyond 50 Rj on the nightside explosively reconnects as the tearing site reaches the low density lobe region above and below the current sheet. Small events occur irregularly but on average about every 4 hours and large events about once a day. The magnetic flux reconnected in such events amounts up to about 70,000 Webers/sec and is sufficient to return the outwardly convected magnetic flux to the inner magnetosphere. Since this process releases plasmoids into the jovian tail, as do terrestrial substorms; since this process involves explosive reconnection across the current sheet on the nightside of the planet, as do terrestrial substorms; and since the process is a key in closing the circulation pattern of the magnetic and plasma flux, as it is in terrestrial substorms; we refer to these events as jovian substorms.

Russell, C. T.↗

Non Radiation Hardened Microprocessors in Spaced Based Remote Sensing Systems

The CALIPSO (Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations) mission is a comprehensive suite of active and passive sensors including a 20Hz 230mj Nd:YAG lidar, a visible wavelength Earth-looking camera and an imaging infrared radiometer. CALIPSO flies in formation with the Earth Observing System Post-Meridian (EOS PM) train, provides continuous, near-simultaneous measurements and is a planned 3 year mission. CALIPSO was launched into a 98 degree sun synchronous Earth orbit in April of 2006 to study clouds and aerosols and acquires over 5 gigabytes of data every 24 hours. The ground track of one CALIPSO orbit as well as high and low intensity South Atlantic Anomaly outlines is shown. CALIPSO passes through the SAA several times each day. Spaced based remote sensing systems that include multiple instruments and/or instruments such as lidar generate large volumes of data and require robust real-time hardware and software mechanisms and high throughput processors. Due to onboard storage restrictions and telemetry downlink limitations these systems must pre-process and reduce the data before sending it to the ground. This onboard processing and realtime requirement load may mean that newer more powerful processors are needed even though acceptable radiation-hardened versions have not yet been released. CALIPSO's single board computer payload controller processor is actually a set of four (4) voting non-radiation hardened COTS Power PC 603r's built on a single width VME card by General Dynamics Advanced Information Systems (GDAIS). Significant radiation concerns for CALIPSO and other Low Earth Orbit (LEO) satellites include the South Atlantic Anomaly (SAA), the north and south poles and strong solar events. Over much of South America and extending into the South Atlantic Ocean the Van Allen radiation belts dip to just 200-800km and spacecraft entering this area are subjected to high energy protons and experience higher than normal Single Event Upset (SEU) and Single Event Latch-up (SEL) rates. Although less significant, spacecraft flying in the area around the poles experience similar upsets. Finally, powerful solar proton events in the range of 10MeV/10pfu to 100MeV/1pfu as are forecasted and tracked by NOAA's Space Environment Center in Colorado can result in Single Event Upset (SEU), Single Event Latch-up (SEL) and permanent failures such as Single Event Gate Rupture (SEGR) in some technologies. (Galactic Cosmic Rays (GCRs) are another source, especially for gate rupture) CALIPSO mitigates common radiation concerns in its data handling through the use of redundant processors, radiation-hardened Application Specific Integrated Circuits (ASIC), hardware-based Error Detection and Correction (EDAC), processor and memory scrubbing, redundant boot code and mirrored files. After presenting a system overview this paper will expand on each of these strategies. Where applicable, related on-orbit data collected since the CALIPSO initial boot on May 4, 2006 will be noted.

Decoursey, Robert J.↗

The Effect of Age in the Alteration in Fluid Balance of Rats in Response to Centrifugation

With an increase in gravity load induced by centrifugation or upon return to Earth following spaceflight, there is a period of adjustment in fluid balance in rats. With centrifugation there is a reduced fluid intake with maintenance of the rate of urine excretion. Following spaceflight there is an increase in urine output and maintenance of fluid intake. The initial period of acclimation to hypergravity is associated with a net loss of fluids. In the present study in response to centrifugation at 2.0 G this period of acclimation is present in mature rats for a longer period of time, about 24 hours. Following this initial response a period of over compensation has previously been reported. In the present study this was not observed. The net effect of these alterations in water intake and output in response to centrifugation for 14 days was slight increase in the percent total body water, with effective compensation seen in both young and mature rats. Older rats have been shown to have a reduced relative thirst and compensatory renal function in response to hypohydration, hyperosmolality and pharmacological stimuli. Responsiveness to these stimuli are delayed and/or attenuated in older animals. Similar findings were noted in the present study in the initial response to centrifugation. The older animal had a delayed return of fluid intake to control levels. The delay of one day did not appear to effect long-term fluid homeostasis, as there was difference in the response of percent total body water at the end of 14 days of centrifugation with both age groups having a slight but significant increase. This increase has been attributed to the increase in lean body mass induced by centrifugation.

Fuller, Charles A.↗

EVs@Scale Next-Gen Profiles - Fleet Utilization 2024

As part of the U.S. Department of Energy’s EVs@Scale initiative, the Next-Gen Profiles (NGP) project provides a comprehensive, data-driven analysis of electric vehicle (EV) and electric vehicle supply equipment (EVSE) operations across real-world fleet deployments. This paper presents findings from the NGP’s Fleet Utilization study, which investigates operational behavior and asset usage across seventeen EV fleets and two EVSE fleets, encompassing a wide range of vehicle types and use cases. Data collected from diverse sources—varying in format and temporal resolution—are first reformatted into a unified structure. From this harmonized dataset, a suite of rigorously defined performance metrics is calculated at an hourly cadence, enabling consistent cross-comparison of charging, routing, and other key operational behaviors. Amid rapidly increasing EV adoption and growing demands for energy-efficient fleet operations, the analysis reveals clear utilization trends—including diurnal and weekly activity cycles, differences in short versus long charging session dependencies, and route-specific energy usage patterns. These findings highlight the need for tailored infrastructure strategies and the deployment of advanced energy management systems, such as Distributed Energy Resource Management Systems (DERMS) and Site Energy Management Systems (SEMS), which can optimize charging schedules and mitigate peak loads. By leveraging anonymized, harmonized datasets and standardized metrics, this study offers critical insights into fleet behavior and performance, providing a foundation to improve operational efficiency, reduce costs, and enable the scalable deployment of electrified transportation.

Wells, Landon↗

Caldera Infrastructure Charge Module (ICM)

Caldera ICM is part of Caldera software platform, a suite of collective, open-source tools that was developed to improve the state of the art in modeling the impacts of Electric Vehicle (EV) charging on the grid. The foundation of Caldera ICM is it’s first-of-its-kind library of high-fidelity charging models for a wide variety of vehicles, validated by test data under a range of operating conditions. The charging models are used to accurately model the EV charging on an electric vehicle supply equipment (EVSE) – also known as a charger. ICM uses as inputs, the EV characteristics such as battery size, battery chemistry (i.e. NMC, LTO), watt hour per mile, inverter efficiency and max charge rate; as well as EVSE characteristics such as max current and supply equipment type (i.e. L2 vs XFC). Using these inputs Caldera ICM creates an uncontrolled charging profile curve for each compatible EV-EVSE pair. These charge profiles can be used stand alone to estimate charge duration given start State Of Charge (SOC) and end SOC or charge energy size given start SOC and charge duration. In Caldera Grid, another tool in the Caldera software platform, these charge profiles are used to represent EV charging as a load on the grid using charge event data such as EV type, SE type, start SOC, final SOC, park start time and park end time. ICM currently supports energy shifting Smart Charge Management (SCM) strategies such as "Time Of Use (TOU) immediate”, “TOU random” and “random start” by delaying the charge to start at a preferable time with respect to the strategy and, one voltage support SCM strategy named autonomous voltage control strategy by providing reactive power back to the electric grid.

Sundarrajan, ManojKumar Cebol↗

Small-scale Assessment of Simplified Ceramic Waste Form Processing

The feasibility of directly processing glass-bonded sodalite ceramic waste form materials by heating a mixture of Zeolite 4A, chloride salt, and sodium borosilicate binder glass was demonstrated by generating laboratory-scale materials. This direct processing method eliminates pre-setting the moisture content of the Zeolite 4A, eliminates the step of occluding salt in the prepared Zeolite 4A prior to processing, and can be conducted using larger particle sizes of crushed Zeolite 4A and crushed borosilicate glass than those called for in the current method. These simplifications are expected to facilitate material transfer and handling in a hot cell or controlled atmosphere environment and be more readily implemented at large scale than the current method. Most materials made to assess these simplifications were directly processed at 925 °C for two hours in an argon atmosphere glovebox, but one material was processed at 925 °C for four hours and one material was processed at 880 °C for two hours. Sodalite was generated and became microencapsulated by the binder glass in all materials. The microstructures were uniform throughout each product, were similar in all products, and were similar to the microstructures of materials made previously using the pressureless consolidation or hot isostatic pressing methods. Various formulations showed the efficiency of sodalite generation was not sensitive to the salt-to-Zeolite 4A ratio or salt-to-glass mass ratio, although a greater relative mass of glass is required to encapsulate sodalite generated from large particles of aggregated Zeolite 4A. The upper limit of salt loadings that can be effectively processed remains to be determined. The effectiveness of direct processing provided new insights into the conversion mechanism. The salt was likely dissolved into the glass that transported NaCl into the Zeolite 4A aggregates and sodalite was generated in situ as NaCl migrated from the outside of the aggregate inward. Other salt cations (e.g., potassium, strontium, cesium, and probably lithium) remain dissolved in the glass encapsulating the zeolite/sodalite domains. When the glass solidifies during cooling, small halite inclusion phases form in glass within sodalite domains and large mixed salt inclusions form in glass surrounding the sodalite due to the low solubility of chloride in the (solid) glass. Other salt cations were oxidized during processing and formed inclusions in the bulk glass (e.g., neodymium). Initial degradation tests show the dissolution behavior of directly processed CWF (SCWF) materials is similar to CWF materials made using different methods.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

STS-114: Discovery L-1 Countdown Status Briefing STS-114/Discovery L-2 Countdown Status Briefing

Bruce Buckingham from NASA Public Affairs introduces Jeff Spaulding, NASA Test Director and Kathy Winters, Shuttle Weather Officer in this L-2 countdown status briefing. Spaulding gives the Space Shuttle launch countdown status before lift-off on July 26th. He expresses that vehicle launch and ground systems are performing well and that there are no significant issues in preparation for the launch. The crew arrival time to the launching pad and the launch window for Discovery is also discussed. He ends his countdown status by expressing that the Discovery Orbiter is the safest Shuttle to date. Kathy Winters gives her weather forecast for the launch day. She presents a satellite picture of tropical storm Franklin and charts showing the STS-114 Tanking Forecast, Launch Forecast, Solid Rocket Booster (SRB) recovery, Continental United States (CONUS) launch, Transoceanic Abort Landing (TAL) launch, 24 and 48 Hour Delay, CONUS 24 and 48 hour delay, and TAL 24 and 48 hr delay. Questions from the news media about the mood of the test engineers as launch day is approached are answered. Jessica Rye from NASA Public Affairs introduces Pete Nikolento, NASA Test Director; Scott Higgenbotham, STS-114 Payload Mission Manager; and Kathy Winters, Space Shuttle Weather Officer in this L-1 Countdown Status Briefing. Nikolento expresses that the completion of the main engine system check-outs and servicing of on-board fuel-cell reactants have been completed. He also talks about pad closeouts and external cryogenic loads prior to launch. Scott Higgenbotham gives the payload status and Kathy Winters talks about her weather forecast for launch. Questions about the ecosensors, TAL sites, weather forecast and thoughts about return to flight are addressed.

Source record↗

Techno-Economic Analysis of Geologically Connected Seawater Air Conditioning (GeoSWAC) Concept for District Cooling at the University of Puerto Rico at Rio Piedras

At the University of Puerto Rico at Rio Piedras, a central chilled water plant supplies cooling to several campus buildings, contributing significantly to electricity demand during daytime peak hours, particularly in the summer months. These operational challenges are exacerbated by Puerto Rico's tropical rainforest climate and a power grid vulnerable to frequent disruptions caused by hurricanes and tropical storms. This study presents a techno-economic analysis of the existing chilled water plant serving four representative campus buildings and introduces a conceptual alternative: the Geologically connected Seawater Air Conditioning (GeoSWAC) system. GeoSWAC leverages stable low temperatures of deep ocean water (~1 km depth), hydraulically connected to an inland well, to deliver cooling without the use of vapor-compression refrigeration. Using modeled annual cooling loads and chiller performance data, capital costs, energy consumption, and levelized cost of cooling (LCOC) were evaluated for both systems. While GeoSWAC showed higher capital costs than the chiller-based scenario, operational costs were significantly lower at $26k-$53k annually, resulting in a lower LCOC between $2.3/MWh and $8.2/MWh compared to $30.2/MWh-$33.6/MWh for the chiller scenario. These results suggest that the GeoSWAC system offers a promising, low-energy, and climate-resilient alternative for large-scale cooling in tropical coastal environments, with significant potential to reduce peak electricity demand and improve long-term system reliability.

15 GEOTHERMAL ENERGY↗

Techno-Economic Analysis of Geologically Connected Seawater Air Conditioning (GeoSWAC) Concept for District Cooling at the University of Puerto Rico at Rio Piedras: Preprint

At the University of Puerto Rico at Rio Piedras, a central chilled water plant supplies cooling to several campus buildings, contributing significantly to electricity demand during daytime peak hours, particularly in the summer months. These operational challenges are exacerbated by Puerto Rico's tropical rainforest climate and a power grid vulnerable to frequent disruptions caused by hurricanes and tropical storms. This study presents a techno-economic analysis of the existing chilled water plant serving four representative campus buildings and introduces a conceptual alternative: the Geologically connected Seawater Air Conditioning (GeoSWAC) system. GeoSWAC leverages stable low temperatures of deep ocean water (~1 km depth), hydraulically connected to an inland well, to deliver cooling without the use of vapor-compression refrigeration. Using modeled annual cooling loads and chiller performance data, capital costs, energy consumption, and levelized cost of cooling (LCOC) were evaluated for both systems. While GeoSWAC showed higher capital costs than the chiller-based scenario, operational costs were significantly lower at $26k-$53k annually, resulting in a lower LCOC between $2.3/MWh and $8.2/MWh compared to $30.2/MWh-$33.6/MWh for the chiller scenario. These results suggest that the GeoSWAC system offers a promising, low-energy, and climate-resilient alternative for large-scale cooling in tropical coastal environments, with significant potential to reduce peak electricity demand and improve long-term system reliability.

15 GEOTHERMAL ENERGY↗

Life Cycle Assessment and Life Cycle Cost Analysis of Repurposing Decommissioned Wind Turbine Blades as High-Voltage Transmission Poles

Wind energy is widely deployed and will likely grow in service of reducing the world’s dependency on fossil fuels. The first generation of wind turbines are now coming to the end of their service lives, and there are limited options for the reuse or recycling of the composite materials they are made of. Current literature has verified that there is no existing recycling pathway (i.e., mechanical, chemical, thermal methods of recovery, etc.) for end-of-life materials in wind blades that can meet cost parity with landfilling in the US. However, to the authors’ knowledge there is no study to date that uncovers the cost structures associated with repurposing wind turbine blades in the US. Repurposing could offer a cost-competitive advantage through displacement of higher-value products, rather than materials or chemical constituents alone. This study implements life cycle assessment (LCA) and life cycle cost analysis (LCC) to assess the environmental and financial implications at each stage of repurposing wind turbine blades as the primary load-carrying elements for high-voltage transmission line structures in the United States. This case study contribution to knowledge is based on the successful management of construction waste by analyzing an application for repurposing construction demolition waste. Specifically, this study presents an environmental and financial analysis of repurposing wind turbine blades as transmission line poles. Under this case study, our results show that BladePoles have lower greenhouse gas emissions than steel poles, and we anticipate BladePoles will be less costly than steel poles. Overall emissions are most sensitive to combustion emissions, driven primarily by transportation distance and hours of required crane operations during the installation process. Compared to other evaluated recycling methods, repurposing wind blades as BladePoles has the least overall global warming potential.

42 ENGINEERING↗

Multi-Fidelity Scheme for Accelerating 4D Finite Element Analysis for Mircoreactors

Next-generation microreactors are currently being designed to be operated terrestrial and extraterrestrial for remote surface power production. These systems will provide an alternative source of carbon-free energy that is versatile and can be utilized for various applications. These applications of microreactors have prompted the usage of high-fidelity unstructured finite element (FE) based approaches to provide time-dependent solutions for multiple physics fields. Computing these high-fidelity (4-D) solutions for multiple design iterations, physics fields, and transient events requires an immense computational cost. These high-fidelity solutions are computational expensive and the cost can be reduced through the implementation of less accurate low-fidelity solutions. Unlike the current fleet of commercial nuclear reactors, these next-gen systems present challenges due to the material and physical limitations required. Due to these constraints, the brute force technique of parameterizing important system characteristics determines whether a design meets the project objective. A system such as a nuclear reactor could have thousands of design parameters that affect system performance. In order to analyze the entire parameter space of such a complex system would require millions of CPU hours and countless design iterations. This costly approach is not practical due to regulatory and budget limitations. In this proposal, an approach that utilizes hybrid high-fidelity and low-fidelity FE models to reduce the computational cost of evaluating these applications in 4-D will be presented. The accuracy of the high-fidelity model and the computational efficiency of the low-fidelity model are taken advantage of to produce a solution that closely resembles the full order high-fidelity solution. By utilizing an unconverged coarse FE mesh, operation limits such as temperature, structural loading, etc., can be evaluated in an accelerated fashion and then can be spatially interpolated onto a finer mesh. The resulting error arising from the coarse mesh can be mitigated with a discrepancy function that actively quantifies and corrects the error in the coarse solution. This discrepancy function can be periodically updated with high-fidelity calculations across the temporal domain thus requiring less iterations on the fine mesh. As a result, the computational cost can be reduced for the evaluation and design iteration of microreactors. The proposal for this research contains three sections: Section 2 provides a literature review, Section 3 outlines the methodology for the proposed multi-fidelity scheme, and Section 4 displays preliminary results of the proposed research.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design description of the Tangaye Village photovoltaic power system

The engineering design of a stand alone photovoltaic (PV) powered grain mill and water pump for the village of Tangaye, Upper Volta is described. The socioeconomic effects of reducing the time required by women in rural areas for drawing water and grinding grain were studied. The suitability of photovoltaic technology for use in rural areas by people of limited technical training was demonstrated. The PV system consists of a 1.8-kW (peak) solar cell array, 540 ampere hours of battery storage, instrumentation, automatic controls, and a data collection and storage system. The PV system is situated near an improved village well and supplies d.c. power to a grain mill and a water pump. The array is located in a fenced area and the mill, battery, instruments, controls, and data system are in a mill building. A water storage tank is located near the well. The system employs automatic controls which provide battery charge regulation and system over and under voltage protection. This report includes descriptions of the engineering design of the system and of the load that it serves; a discussion of PV array and battery sizing methodology; descriptions of the mechanical and electrical designs including the array, battery, controls, and instrumentation; and a discussion of the safety features. The system became operational on March 1, 1979.

Martz, J. E.↗

Damage Tolerance Issues as Related to Metallic Rotorcraft Dynamic Components

In this paper issues related to the use of damage tolerance in life managing rotorcraft dynamic components are reviewed. In the past, rotorcraft fatigue design has combined constant amplitude tests of full-scale parts with flight loads and usage data in a conservative manner to provide "safe life" component replacement times. In contrast to the safe life approach over the past twenty years the United States Air Force and several other NATO nations have used damage tolerance design philosophies for fixed wing aircraft to improve safety and reliability. The reliability of the safe life approach being used in rotorcraft started to be questioned shortly after presentations at an American Helicopter Society's specialist meeting in 1980 showed predicted fatigue lives for a hypothetical pitch-link problem to vary from a low of 9 hours to a high in excess of 2594 hours. This presented serious cost, weight, and reliability implications. Somewhat after the U.S. Army introduced its six nines reliability on fatigue life, attention shifted towards using a possible damage tolerance approach to the life management of rotorcraft dynamic components. The use of damage tolerance in life management of dynamic rotorcraft parts will be the subject of this paper. This review will start with past studies on using damage tolerance life management with existing helicopter parts that were safe life designed. Also covered will be a successful attempt at certifying a tail rotor pitch rod using damage tolerance, which was designed using the safe life approach. The FAA review of rotorcraft fatigue design and their recommendations along with some on-going U.S. industry research in damage tolerance on rotorcraft will be reviewed.

Everett, R. A., Jr.↗

Damage Tolerance Issues as Related to Metallic Rotorcraft Dynamic Components

In this paper issues related to the use of damage tolerance in life managing rotorcraft dynamic components are reviewed. In the past, rotorcraft fatigue design has combined constant amplitude tests of full-scale parts with flight loads and usage data in a conservative manner to provide "safe life" component replacement times. In contrast to the safe life approach over the past twenty years the United States Air Force and several other NATO nations have used damage tolerance design philosophies for fixed wing aircraft to improve safety and reliability. The reliability of the safe life approach being used in rotorcraft started to be questioned shortly after presentations at an American Helicopter Society's specialist meeting in 1980 showed predicted fatigue lives for a hypothetical pitch-link problem to vary from a low of 9 hours to a high in excess of 2594 hours. This presented serious cost, weight, and reliability implications. Somewhat after the U.S. Army introduced its six nines reliability on fatigue life, attention shifted towards using a possible damage tolerance approach to the life management of rotorcraft dynamic components. The use of damage tolerance in life management of dynamic rotorcraft parts will be the subject of this paper. This review will start with past studies on using damage tolerance life management with existing helicopter parts that were safe life designed. Also covered will be a successful attempt at certifying a tail rotor pitch rod using damage tolerance, which was designed using the safe life approach. The FAA review of rotorcraft fatigue design and their recommendations along with some on-going U.S. industry research in damage tolerance on rotorcraft will be reviewed. Finally, possible problems and future needs for research will be highlighted.

Everett, R. A., Jr.↗

Satellite Tracking of Shallow Cumulus during CAMP2Ex: The Aerosol and Organization Connection

Shallow moist convection is ubiquitous throughout the tropics and represents a key player in boundary layer processes. Shallow clouds come in many forms, from scattered, short-lived cumulus to organized features that include cold pool boundaries and lines reaching O(100 km) scale lasting several hours. In this study, we explore how cloud morphology and environmental aerosol affect shallow cumulus lifecycle properties. Measuring such influences requires a broad, detailed view of these cloud fields as they grow and decay. Geostationary satellites provide a means to follow the clouds with enhanced spatiotemporal sampling from space. We apply a cloud-tracking tool to study lifecycle properties of shallow cumulus sampled during the NASA Cloud, Aerosol, and Monsoon Processes Philippines Experiment (CAMP2Ex) field campaign of 2019. The mission conducted airborne and shipborne operations over the West Pacific Ocean, in tandem with Rapid Scan imagery from the Advanced Himawari Imager (AHI) on the Japan Meteorological Agency’s (JMA) Himawari-8 satellite. We segment shallow cumulus on AHI 0.5-km visible reflectance during the daylit hours of several research flights that exhibited ideal atmospheric conditions for tracking. We collect the resulting cloud tracks by regions containing airborne sampling of the cloud environments and by two specific segmentation techniques: one optimized for small, disorganized cumulus and the other for larger, organized clouds using suitable thresholds for reflectance and blurring. We present an analysis of cloud lifecycle properties using our dual segmentation approach for various sampled environments of CAMP2Ex. A total of 7 research flights (RFs) exhibited ideal conditions for generating cloud-track ensembles under similar thermodynamic and kinematic profiles but with varying aerosol load. We consider lifetime, track-achieved metrics, and ensemble-fitted growth rates to evaluate the aerosol effect. Cloud elongation, a factor in cloud morphology, is also considered for any potential influence in observed shifts in growth rates. The results suggest that aerosol affects cloud lifecycles more significantly for clouds with larger areas and independent of the elongation factor.

Cloud Tracking↗