Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Helium cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Measurement of heat conduction through stacked screens

This paper describes the experimental apparatus for the measurement of heat conduction through stacked screens as well as some experimental results taken with the apparatus. Screens are stacked in a fiberglass-epoxy cylinder, which is 24.4 mm in diameter and 55 mm in length. The cold end of the stacked screens is cooled by a Gifford-McMahon (GM) cryocooler at cryogenic temperature, and the hot end is maintained at room temperature. Heat conduction through the screens is determined from the temperature gradient in a calibrated heat flow sensor mounted between the cold end of the stacked screens and the GM cryocooler. The samples used for these experiments consisted of 400-mesh stainless steel screens, 400-mesh phosphor bronze screens, and two different porosities of 325-mesh stainless steel screens. The wire diameter of the 400-mesh stainless steel and phosphor bronze screens was 25.4 micrometers and the 325-mesh stainless steel screen wire diameters were 22.9 micrometers and 27.9 micrometers. Standard porosity values were used for the experimental data with additional porosity values used on selected experiments. The experimental results showed that the helium gas between each screen enhanced the heat conduction through the stacked screens by several orders of magnitude compared to that in vacuum. The conduction degradation factor is the ratio of actual heat conduction to the heat conduction where the regenerator material is assumed to be a solid rod of the same cross sectional area as the metal fraction of the screen. This factor was about 0.1 for the stainless steel and 0.022 for the phosphor bronze, and almost constant for the temperature range of 40 to 80 K at the cold end.

NASA Discipline Environmental Health↗

A study of a high resolution IUE spectrum of AM Canum Venaticorum

We have obtained the first high resolution IUE spectrum of the helium-rich, cataclysmic variable star AM CVn. The spectrum is greatly underexposed, but we can still detect both wide and narrow line profiles. We report broad, shortward-shifted, P-Cygni-like absorption and in some cases emission lines in the far UV high ionization resonance lines of C, N, O, and Si, but the profiles are considerably disk/boundary layer outflows, absorption disk continuum light in H-rich CVs. The highest ionizations show evidence of a narrow jet or conical flow. For other, lower ionized lines, we find some evidence of a stellar origin. The broad He II (lambda 1640 A) absorption profile with blue shifted emission core has a remarkably similar overall structure to the He II (lambda 1640 A) broad absorption trough in the IUE spectrum of the prototypical cool DO white dwarf HZ 21. The sharp absorption lines seem most convincingly in the resonance doublets of N V (lambda 1238 A, lambda 1242 A) and C IV (lambda 1548 A, lambda 1550 A) and in He II (lambda 1640 A) exhibit a precise velocity coincidence. These sharp features are almost certainly due to circumbinary matter because they are obviously unaffected by the rapid orbital motion (or rapid stellar rotation) in this short period system during the long (9.3 hour) IUE echelle exposure. Our observations support an evolution through shell episodes of a close binary system which ends up with an expanding envelope as seen for HZ 21, and suggests one possible evolutionary channel for production of DOs (DBs).

Solheim, J.-E.↗

Thermal Model Heat Rate Predictions of the AGR-5/6/7 Experiment

Several fuel and material irradiation experiments have been planned for the U.S. Department of Energy Advanced Gas Reactor Fuel Development and Qualification Program, which supports the development and qualification of tristructural isotropic (TRISO) coated particle fuel for use in high-temperature gas-cooled reactors. The goals of these experiments are to provide irradiation performance data to support fuel process development, qualify fuel for normal operating conditions, support development of fuel performance models and codes, and provide irradiated fuel and materials for post-irradiation examination and safety testing. Originally planned and named as separate fuel experiments, but subsequently combined into a single test train. AGR-5/6/7 will test low-enriched uranium oxycarbide (UCO – a heterogeneous mixture of uranium oxide and uranium carbide) TRISO fuel. The AGR-5/6 portion of the experiment will provide data to support qualification of the selected reference fuel design, while the AGR-7 portion will serve as a margin test, irradiating the fuel beyond normal operating conditions. During irradiation, the temperature in each capsule is controlled by varying the helium / neon gas mixture flowing through the capsule until the desired thermocouple temperature is reached. Further adjustments can be made by changing the lobe power and the neutron filter. Three neutron filters are available to use as the experiment burns up the fissionable fuel. A thermal finite element model has been created for the five capsules comprising the AGR-5/6/7 experiment. Heat rates from a physics analysis are imported into the model along with fast neutron fluence. Graphite shrinkage due to the fast neutron fluence is incorporated into the model. Gas gaps change as a function of fast neutron fluence. Radiation heat transfer is a major contributor in this model. This is a large model with more than 1 million finite element brick elements. More than 150 different parts are modeled in the finite element model and communicate with each other from a heat transfer sense. More than 50 thermocouples are used in the experiment and are compared to actual measurements. The experiment is composed of five separate stainless steel capsules all welded together. This paper presents a method used to predict the gas mixture in the event that all of the thermocouples fail in a particular capsule. Curve fitting of heat rates from previous cycles and projecting them into the future is the basis of the method.

36 MATERIALS SCIENCE↗

Generation IV Benchmarking of TRISO Fuel Performance Models Under Accident Conditions Final Report

The Generation IV International Forum (GIF) is a co-operative international endeavor of fourteen members organized to carry out the research and development needed to establish the feasibility and performance capabilities of the next generation nuclear energy systems. GIF selected six reactor technologies, amongst which is the Very High Temperature Reactor (VHTR) that is primarily dedicated to the cogeneration of electricity and hydrogen. The technical basis for VHTR is the tristructural isotropic (TRISO)-coated particle fuel, the graphite as the core structure, helium coolant, as well as the dedicated core layout and lower power density to removal decay heat in a natural way. At the heart of safety features of the VHTR concept lie the TRISO fuel particles that are designed to keep their structural integrity and retain fission products at temperatures up to 1600°C. As part as the design and future operation of VHTRs, a key aspect is the accurate prediction of fuel performance under irradiation and accident conditions. Modeling and simulation allow prediction of TRISO fuel behavior when subject to neutron flux and in high temperature accident scenarios. The refinement of the fuel performance models and codes is performed by comparison to in-pile and out-of-pile experimental data that reproduce the expected irradiation conditions in high temperature gas-cooled reactors (HTGRs). Historically, the International Atomic Energy Agency (IAEA) developed a benchmark dedicated to the validation of predictive methods for fuel and fission product behavior through the Coordinated Research Program CRP-2 (IAEA, 1997). CRP-2 was later updated to cover fuel fabrication, quality assurance, irradiation performance, safety testing, and spent fuel. The scope of the resulting CRP-6 benchmarks focused on HTGR fuel performance and fission product release (IAEA, 2012). Taking advantage of additional TRISO fuel fabrication, irradiation, and safety testing campaigns, GIF launched a Generation IV Benchmarking of TRISO Fuel Performance Models under Accident Conditions in late 2015. This GIF benchmark is a three-year program steered by Idaho National Laboratory (INL, USA). The other participants include the Japan Atomic Energy Agency (JAEA, Japan) and the Korea Atomic Energy Research Institute (KAERI, Korea). The objectives of the benchmark are to: follow on the IAEA CRP benchmarks, (2) model fission product release under accident conditions, (3) compare results obtained by the fuel performance modeling codes of the benchmark participants, and (4) compare these code predictions to experimental data. Safety tests chosen for modeling include the first and second experiments of the Advanced Gas Reactor program (AGR-1 and AGR-2) and the High Flux Reactor (HFR) EU1bis experiment. This report presents the results obtained by the three research institutions using their respective fuel performance modeling codes. Comparisons of the corresponding fission product release predictions are made with experimental data from AGR-1, AGR-2, and HFR-EU1bis. The benchmark results show good agreements between all participants but also show a general trend of over-prediction of the experimental release data, which is mainly attributed to the use of over-estimated diffusion coefficients.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evacuated load-bearing high performance insulation study

A light weight, vacuum jacketed, load bearing cryogenic insulation system was developed and tested on a 1.17-m (46-in.) spherical test tank. The vacuum jacket consists of 0.08 mm (0.003 in.) thick 321 stainless steel formed into a wedge design that allows elastic jacket movements as the tank shrinks (cools) or expands (warms up or is pressurized). Hollow glass spheres, approximately 80 micrometers in diameter with a bulk density of 0.069 g/cc (4.3 lb cubic foot), provide the insulating qualities and one atmosphere load bearing capability required. The design, fabrication, and test effort developed the manufacturing methods and engineering data needed to scale the system to other tank sizes, shapes, and applications. The program demonstrated that thin wall jackets can be formed and welded to maintain the required vacuum level of .013 Pa yet flex elastically for multiple reuses. No significant shifting or breakage of the microspheres occurred after 13 simulated Space Tug flight cycles on the test tank and a hundred 1 atmosphere load cycles in a flat plate calorimeter. The test data were then scaled to the Space Tug LO2 and LH2 tanks, and weight, thermal performance, payload performance, and costs were compared with a helium purged multilayer insulation system.

Parmley, R. T.↗

The Rapid Evolution of the Exciting Star of the Stingray Nebula

Context: SAO244567, the exciting star of the Stingray nebula, is rapidly evolving. Previous analyses suggested that it has heated up from an effective temperature of about 21 kK in 1971 to over 50 kK in the 1990s. Canonical post-asymptotic giant branch evolution suggests a relatively high mass while previous analyses indicate a low-mass star. Aims: A comprehensive model-atmosphere analysis of UV and optical spectra taken during 1988-2006 should reveal the detailed temporal evolution of its atmospheric parameters and provide explanations for the unusually fast evolution. Methods: Fitting line profiles from static and expanding non-LTE model atmospheres to the observed spectra allowed us to study the temporal change of effective temperature, surface gravity, mass-loss rate, and terminal wind velocity. In addition, we determined the chemical composition of the atmosphere. Results: We find that the central star has steadily increased its effective temperature from 38 kK in 1988 to a peak value of 60 kK in 2002. During the same time, the star was contracting, as concluded from an increase in surface gravity from log g = 4.8 to 6.0 and a drop in luminosity. Simultaneously, the mass-loss rate declined from log(M/M (solar mass) yr (exp −1)) = −9.0 to −11.6 and the terminal wind velocity increased from v (infinity) = 1800 km s (exp −1) to 2800 km s (exp −1). Since around 2002, the star stopped heating and has cooled down again to 55 kK by 2006. It has a largely solar surface composition with the exception of slightly subsolar carbon, phosphorus, and sulfur. The results are discussed by considering different evolutionary scenarios. Conclusions: The position of SAO244567 in the log T (sub eff) -log g plane places the star in the region of sdO stars. By comparison with stellar-evolution calculations, we confirm that SAO244567 must be a low-mass star (M < 0.55 solar mass). However, the slow evolution of the respective stellar evolutionary models is in strong contrast to the observed fast evolution and the young planetary nebula with a kinematical age of only about 1000 years. We speculate that the star could be a late He-shell flash object. Alternatively, it could be the outcome of close-binary evolution. Then SAO244567 would be a low-mass (0.354 solar mass) helium pre-white dwarf after the common-envelope phase, during which the planetary nebula was ejected.

Stingray↗

Performance of the Spacecraft Propulsion Research Facility During Altitude Firing Tests of the Delta 3 Upper Stage

The Spacecraft Propulsion Research Facility at the NASA Lewis Research Center's Plum Brook Station was reactivated in order to conduct flight simulation ground tests of the Delta 3 cryogenic upper stage. The tests were a cooperative effort between The Boeing Company, Pratt and Whitney, and NASA. They included demonstration of tanking and detanking of liquid hydrogen, liquid oxygen and helium pressurant gas as well as 12 engine firings simulating first, second, and third burns at altitude conditions. A key to the success of these tests was the performance of the primary facility systems and their interfaces with the vehicle. These systems included the structural support of the vehicle, propellant supplies, data acquisition, facility control systems, and the altitude exhaust system. While the facility connections to the vehicle umbilical panel simulated the performance of the launch pad systems, additional purge and electrical connections were also required which were unique to ground testing of the vehicle. The altitude exhaust system permitted an approximate simulation of the boost-phase pressure profile by rapidly pumping the test chamber from 13 psia to 0.5 psia as well as maintaining altitude conditions during extended steady-state firings. The performance of the steam driven ejector exhaust system has been correlated with variations in cooling water temperature during these tests. This correlation and comparisons to limited data available from Centaur tests conducted in the facility from 1969-1971 provided insight into optimizing the operation of the exhaust system for future tests. Overall, the facility proved to be robust and flexible for vehicle space simulation engine firings and enabled all test objectives to be successfully completed within the planned schedule.

Meyer, Michael L.↗

20 K Helium Refrigeration System for NASA-JSC Chamber-A

A new 20 K helium refrigerator installed at NASA Johnson Space Center's Space Environment Simulation Laboratory (SESL) was successfully commissioned and tested in 2012. The refrigerator is used to create a deep space environment within SESL s Chamber A to perform ground testing of the James Webb Space Telescope. The chamber previously and currently still has helium cryopumping panels (CPP) and LN2 shrouds used to create Low Earth Orbit environments. Now with the new refrigerator and new helium shrouds (45 x 65 ) the chamber can create a deep space environment. The process design, system analysis, specification development, and commissioning oversight were performed by the cryogenics department at Jefferson Labs, while the contracts and system installation was performed by the ESC group at JSC. Commissioning data indicate a inverse coefficient of performance better than 70 W/W for a 18 KW load at 20 K (accounting for liquid nitrogen precooling power) that remains essentially constant down to 1/3 of this load. Even at 10 percent of the maximum capacity, the performance is better than 140 W/W at 20K. The refrigerator exceeded all design goals and demonstrated the ability to support a wide load range from 10kW at 15 K to 100 kW at 100K. The refrigerator is capable of operating at any load temperature from 15K to ambient with tight temperature stability. The new shroud (36 tons of aluminum) can be cooled from room temperature to 20 K in 24 hours. This paper will outline the process design and commissioning results.

Homan, J.↗

Spectral Irradiance Measurements of Simulated Lightning in Planetary Atmospheres

Optical emissions from lightning provide information to estimate the altitude, latitude and longitude of lightning storms, the energy of the discharges, and the production of important trace species such as HCN and C2H2. Knowledge of the spectra of planetary lightning is needed to deduce the total energy dissipated by lightning (and thereby, the production of trace gases) and to help design experiments to detect and track lightning storms. Measurements of the spectral irradiance from approximately 380 to 820 nm are reported for laboratory simulations of lightning in the atmospheres of Venus, Jupiter, and Titan. In our laboratory, laser-induced plasmas (LIP) are used to simulate lightning discharges. This technique avoids contamination of the spectra by elect-ode material and maintains a safe environment while allowing the use of flammable gases, such as hydrogen and methane, found in outer planet atmospheres. The observations were made at I and 5 bars pressure for Venus and Jupiter and at 1 bar for the Titan mixture. At a pressure of one bar, our results show prominent lines from H(sub alpha), H(sub beta), H(sub gamma), and H(sub delta) lines of the Balmer Series of atomic hydrogen, a single line from Helium at 588 nm and strong continuum radiation. At pressures of 5 bars, the H(sub alpha) and H(sub beta) lines are wider, the H(sub gamma), and H(sub delta) lines merge into the continuum because of pressure broadening, and the helium line at 588 nm is no longer visible. The observed spectra of simulated lightning in the venusian atmosphere at 1 and 5 bars shows that the OI multiplet at 777.7 nm dominates the spectra, but weak features due to atomic carbon and singly excited and singly ionized oxygen atoms are also visible. Although lightning has not yet been observed on Titan, it conceivable that some form of lightning discharge could be occurring. Therefore experiments on a Titan atmosphere mixture were conducted. The most prominent features seen in the simulated spectra are the H(sub alpha) at 656 nm. from the dissociation of the methane and two strong features at 740 and 820 nm from singly excited nitrogen atoms. Most of the features between 400 and 656 nm are due to ionized nitrogen atoms. A broad, highly structured feature centered near 389 nm is molecular band radiation from CN molecules formed in the cooling plasma of atomic nitrogen, carbon, and hydrogen. It is observed in the lightning simulations of both the venusian and Titan atmospheres, For Venus, Jupiter, and Titan, narrow spectral features that are ideal for detecting lightning in the presence of sunlight are present in the spectra. These features could allow lightning to be detected and tracked by Earth-based instruments.

Borucki, W. J.↗

Performance Model for Reversible Fluid Balloons

The Altitude Control Experiment (ALICE) is a balloon system that consists of a helium lifting balloon and a buoyancy-controlling freon R114 balloon. Condensation of freon gas in the cooler upper atmosphere and vaporization of liquid freon in the warmer lower atmosphere can be effectively used to adjust the net buoyant force so that the balloon system may float between desirable ranges of altitudes.This report summarizes efforts to produce an analytical model to predict the performance of this type of altitude control balloon in the earth's atmosphere. Various interactive parameters that are influential to the dynamics of the system were identified and treated. The analytical model developed herein correlated well with three ALICE day flight trajectories and one ALICE night flight trajectory in the earth's atmosphere. A similar approach can be applied to the design of a Venusian balloon system that could repeatedly travel to the lower, hot altitudes or surface of Venus for imaging or science experiments and then float higher in order to cool the electronics.

balloon↗

Flow of superfluid helium in tubes with heated walls

The equations for superfluid helium flowing through a straight tube with heated walls are integrated. The model equations are based on those of Landau as modified for superfluid turbulence by Gorter and Mellink (1949). The model is implemented by the program SUPERFLOW which runs on a personal computer. The effect of the heating level on the mass flux, the energy flux, and the pressure and temperature profiles is investigated. The four types of profiles which occur without sidewall heating are also found with heated walls. The progression through these four types is shown to depend primarily on the dimensionless parameter, defined previously to characterize the unheated profiles, and a dimensionless ratio of heat fluxes. The pressure and temperature maxima which rise well above the boundary values increase significantly with sidewall heating. Approximate design equations for estimating the mass flux and the profiles are presented. The physical basis of the results is discussed. These results are useful in the design of optimal cooling loops and other superfluid flow systems.

Snyder, H. A.↗

Consequences of a conductive boundary on the local cloud. I - No dust

Using boundary conditions appropriate to the Local Cloud embedded in the Local Bubble, the evaporation of the cloud is modeled assuming steady flow. Included in the model are the effects of radiative cooling and nonequilibrium ionization structure in the interface, and pressure support and heat conduction inhibition due to the magnetic field. The soft X-ray and EUV emission from the interface are calculated and compared with observations. It is found that the emission in the softest X-ray band, the Be band, is harder than that calculated for an equilibrium, normal abundance, 10 to the 6th K plasma. Column densities of C IV, N V, O VI, Si IV, and Si III in the interface are calculated. The column density for O VI is found to be very close to observed values for nearby stars, while all others are too small to contribute significantly to observed values. The ionization of the Local Cloud due to radiation from the interface is calculated. It is found that a significant amount of ionizing radiation is produced, dominating all other known sources. The hardness of the emission, however, results in ionization of helium as well as hydrogen. Thus, the type of boundary modeled cannot explain the ionization of the very local interstellar medium inferred from solar backscatter measurements.

Slavin, Jonathan D.↗

Flow visualization study of the effect of injection hole geometry on an inclined jet in crossflow

A flow visualization was studied by using neutrally buoyant, helium-filled soap bubbles, to determine the effect of injection hole geometry on the trajectory of an air jet in a crossflow and to investigate the mechanisms involved in jet deflection. Experimental variables were the blowing rate, and the injection hole geometry cusp facing upstream (CUS), cusp facing downstream (CDS), round, swirl passage, and oblong. It is indicated that jet deflection is governed by both the pressure drag forces and the entrainment of free-stream fluid into the jet flow. For injection hole geometries with similar cross-sectional areas and similar mass flow rates, the jet configuration with the larger aspect ratio experienced a greater deflection. Entrainment arises from lateral shearing forces on the sides of the jet, which set up a dual vortex motion within the jet and thereby cause some of the main-stream fluid momentum to be swept into the jet flow. This additional momentum forces the jet nearer the surface. Of the jet configurations, the oblong, CDS, and CUS configutations exhibited the largest deflections. The results correlate well with film cooling effectiveness data, which suggests a need to determine the jet exit configuration of optimum aspect ratio to provide maximum film cooling effectiveness.

Simon, F. F.↗

Flow visualization study of the effect of injection hole geometry on an inclined jet in crossflow

A flow visualization was studied by using neutrally buoyant, helium-filled soap bubbles, to determine the effect of injection hole geometry on the trajectory of an air jet in a crossflow and to investigate the mechanisms involved in jet deflection. Experimental variables were the blowing rate, and the injection hole geometry cusp facing upstream (CUS), cusp facing downstream (CDS), round, swirl passage, and oblong. It is indicated that jet deflection is governed by both the pressure drag forces and the entrainment of free-stream fluid into the jet flow. For injection hole geometries with similar cross-sectional areas and similar mass flow rates, the jet configuration with the larger aspect ratio experienced a greater deflection. Entrainment arises from lateral shearing forces on the sides of the jet, which set up a dual vortex motion within the jet and thereby cause some of the main-stream fluid momentum to be swept into the jet flow. This additional momentum forces the jet nearer the surface. Of the jet configurations, the oblong, CDS, and CUS configurations exhibited the largest deflections. The results correlate well with film cooling effectiveness data, which suggests a need to determine the jet exit configuration of optimum aspect ratio to provide maximum film cooling effectiveness.

Simon, Frederick F.↗

X-Ray Flare Characteristics in the B2e Star Lambda Eridani (ROSAT)

We document the results of a simultaneous wavelength monitoring on the B2e star (lambda) Eri. This campaign was carried out from ground stations and with the ROSAT, ASCA, IUE, and Voyager 2 space platforms during a week in February-March 1995; a smaller follow-up was conducted in September 1995. During the first of these intervals (lambda) Eri exhibited extraordinary wind and disk-ejection activity. The ROSAT/HRI X-ray light curves showed no large flares such as the one the ROSAT/PSCA observed in 1991. However, possible low level fluctuations in the February-March ROSAT data occurred at the same time as unusual activity in H(alpha) He I (lambda)6678, He II (lambda)1640, and the C IV doublet. For example, the hydrogen and helium lines exhibited an emission in the blue half of their profiles, probably lasting several hours. The C IV lines showed a strong high-velocity Discrete Absorption Component (DAC) accompanied by unusually strong absorption at lower velocities. The helium line activity suggests that a mass ejection occurred at the base of the wind while the strong C III (Voyager) and C IV (IUE) lines implies that shock interactions occurred in the wind flow. It is not clear that the X-ray elevations are directly related to the strong C IV absorptions because the former changed on a much more rapid timescale than absorptions in the C IV lines. Within hours of the mild X-ray flux variations found by ROSAT on February 28, the Voyager UVS observed a "ringing" that decayed over three 3-hr. cycles. The amplitude of these fluctuations was strong (50%) at (lambda)(lambda)950-1100, decreased rapidly with wavelength, and faded to nondetection longward of (lambda)1300. Various considerations indicate that these continuum variations were not due to an instrumental pathology in the UVS. Rather, they appear to be due to a time-dependent flux deficit in the (lambda)(lambda)950-1250 region. We outline a scenario in which a dense plasma structure over the star's surface is heated and cooled quasi-periodically to produce such flux changes. Observations of new examples of this phenomenon are badly needed. Amateur astronomers can make a significant contribution to its understanding by searching for ringing in light curves of Be stars during their outburst phases. Finally we draw attention to an increase in the emission of the H(alpha) line that occurred at about the time the FUV ringing started. This increased emission hints that approximately 50,000K plasma near the star's surface can influence the circumstellar disc at approximately 12R. by its increased Lyman continuum flux.

Smith, Myron A.↗

Magma ocean: Mechanisms of formation

The thermal state of the Earth at the time relevant to formation of a magma ocean was dominated by the great impact that created the Moon. As shown in computer experiments, the iron in the impacting bodies quickly sank to the core of the proto-Earth, while a significant fraction of silicates was pushed far enough out beyond the geosynchronous limit to constitute the main material of the Moon. Most of any atmosphere would have been pushed aside, rather than being expelled in the impact. However, the energy remaining in the material not going to the core or expelled was still sufficient to raise its temperature some 1000's of degrees, enough to vaporize silicates and to generate a strong 'planetary wind': a hydrodynamic expansion carrying with it virtually all volatiles plus appreciable silicates. This expansion was violent and uneven in its most energetic stage, but probably the resulting magma ocean was global. The duration, until cooling, was sufficient for silicates to condense to melt and the duration was probably short. Comparison of the Earth and Venus indicates that the great impact was extraordinarily effective in removing volatiles from the proto-Earth; in particular, the enormous differences in primordial inert gases between the planets demand a catastrophic difference in origin circumstances. On the other hand, the comparison limits the amount of silicates lost by the Earth to a rather minor fraction; most of that expelled in the wind must have condensed soon enough for the silicate to fall back to Earth or be swept up by the proto-Moon. So the Earth was left with a magma ocean. The question is whether sufficient water was retained to constitute a steam atmosphere. Probably not, but unknowns affecting this question are the efficiencies of outgassing in great impacts and in subsequent convective churnings deep in the mantle. During the stage when mantle convection is turbulent, an appreciable fraction of volatiles were also retained at depth, perhaps in some mineral phases not yet well-defined. We still have primordial helium being outgassed.

Kaula, W. M.↗

Pressure-Fed LOX/LCH4 Reaction Control System for Spacecraft: Transient Modeling and Thermal Vacuum Hotfire Test Results

An integrated cryogenic liquid oxygen, liquid methane (LOX/LCH4) reaction control system (RCS) was tested at NASA Glenn Research Center's Plum Brook Station in the Spacecraft Propulsion Research Facility (B-2) under vacuum and thermal vacuum conditions. The RCS is a subsystem of the Integrated Cryogenic Propulsion Test Article (ICPTA), a pressure-fed LOX/LCH4 propulsion system composed of a single 2,800 lbf main engine, two 28 lbf RCS engines, and two 7 lbf RCS engines. Propellants are stored in four 48 inch diameter 5083 aluminum tanks that feed both the main engine and RCS engines in parallel. Helium stored cryogenically in a composite overwrapped pressure vessel (COPV) flows through a heat exchanger on the main engine before being used to pressurize the propellant tanks to a design operating pressure of 325 psi. The ICPTA is capable of simultaneous main engine and RCS operation. The RCS engines utilize a coil-on-plug (COP) ignition system designed for operation in a vacuum environment, eliminating corona discharge issues associated with a high voltage lead. There are two RCS pods on the ICPTA, with two engines on each pod. One of these two engines is a heritage flight engine from Project Morpheus. Its sea level nozzle was removed and replaced by an 85:1 nozzle machined using Inconel 718, resulting in a maximum thrust of 28 lbf under altitude conditions. The other engine is a scaled down version of the 28 lbf engine, designed to match the core and overall mixture ratios as well as other injector characteristics. This engine can produce a maximum thrust of 7 lbf with an 85:1 nozzle that was additively manufactured using Inconel 718. Both engines are film-cooled and capable of limited duration gas-gas and gas-liquid operation, as well as steady-state liquid-liquid operation. Each pod contains one of each version, such that two engines of the same thrust level can be fired as a couple on opposite pods. The RCS feed system is composed of symmetrical 3/8 inch lines that tap off of the main propellant manifold to send LOX and LCH4 outboard to the RCS pods. A Thermodynamic Vent System (TVS) is used to condition propellants at each pod by venting through an orifice and then routing the cold expansion products back through tubing that is welded along a large portion of the main RCS feed lines. Prior to final installation on the ICPTA, the RCS engines were tested in a small vacuum chamber at the Johnson Space Center (JSC) Energy Systems Test Area (ESTA) to verify functionality of the new COP ignition system and check out operation of the vacuum nozzles. After engine-level testing, the RCS engines were installed on the vehicle and a series of integrated hot-fire tests were performed at JSC consisting of various pulsing and steady-state firings as well as integrated main engine/RCS operation. The ICPTA was then integrated into the Plum Brook B-2 facility for vacuum and thermal/vacuum testing. Testing in the B-2 facility was composed of multiple thermal and pressure environments. The first set of tests were performed under ambient temperature and altitude pressure conditions. These tests consisted of a range of minimum impulse bit (MIB) pulsing sequences with low duty cycle, analogous to a coast phase in which the RCS is primarily used for station keeping. The primary goal of this sequence is to understand how propellant conditions were effected without an active TVS. In this scenario, consistent gas-gas operation is desirable since it results in a smaller MIB and more efficient propellant consumption. Multiple skin thermocouples are mounted on the feedlines, in addition to a submerged thermocouple on each commodity, in order to gather thermal data on the system. Higher duty cycle pulsing tests were then performed, analogous to an ascent or landing mission phase. The primary goal of this sequence was to examine how well the engines self-conditioned without active TVS when starting from a quiescent state. The TVS was then activated during some tests to demonstrate the capability to quickly condition the engines for higher pulsing demand scenarios. A thermocouple at the TVS outlet allows for the calculation of energy absorbed by the vented propellant. Lastly, tests with longer pulses and multiple engines firing either in sequence or simultaneously were run in order to gather transient system response data on waterhammer. Six total high-speed pressure transducers are installed on the RCS system, one sensor at the end of each propellant manifold line on the pods, and one at the tap-off location for each commodity. This will allow for the accurate characterization of waterhammer in the system under various propellant conditions and firing sequences. Other instrumentation for this test series includes nozzle throat thermocouples, chamber pressure measurement, heat soakback measurement, and tank wall plume impingement temperature measurement. The next set of tests were performed to demonstrate simultaneous main engine and RCS operation. Data from this test will be used to examine if there is any change to nominal operation of the RCS as a result of feed system interaction or other phenomenon. Some of these tests began under high vacuum conditions (target ambient pressure less than 1x10(exp -3) torr) and others began at altitude conditions. The last set of tests were performed with the B-2 cold wall active. Under these tests, many of the same low duty cycle MIB tests were repeated in order to characterize how propellant conditions changed with the lower heat leak. In this scenario the RCS manifold experiences much less heat leak, resulting in a change to how well the engines self-condition. As a result, an increase in maximum waterhammer pressures and a change in natural frequency of the system was expected due to higher density propellants. The lower heat leak should also result in a change to the MIB pulse profile, and data will be examined to understand how MIB repeatability is affected in the different operating environments. Parallel to the test efforts, a set of transient model development efforts were made to predict RCS performance. The primary effort was aimed at producing a SINDA/FLUINT model to predict propellant conditioning up to the engine inlet as a function of different environmental and operating parameters, with the goal of predicting chamber pressure, TVS performance, and propellant consumption over time. Preliminary results for this effort will be presented in comparison with test data. Additional modeling efforts were made using SINDA/FLUINT to predict waterhammer in the system since the software is capable of handling multiphase transient fluid dynamics. These results will be compared with the high-speed pressure transducer test data for validation purposes.

Atwell, Matthew J.↗