Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gas sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Wellbore cement alteration and roles of CO 2 and shale during underground hydrogen storage

To mitigate climate change and adopt renewable energy, energy storage is crucial and can be done in the form of hydrogen gas (H 2 ). Subsurface geologic reservoirs are positioned to store H 2 on the largest scales for the longest terms of all potential options. However, H 2 injection may boost reactions that consume hydrogen, generate undesired gases, and alter pore structures of geomedia. To explore the extent of H 2 -associated biotic reactions at a near wellbore location, four experiments were conducted under underground storage conditions with wellbore cement cores and, in most instances, shale samples submerged in synthetic formation brine. Post-reaction gas, aqueous, and solid phase samples were analyzed using olfactory screening and, later, gas chromatography (GC-MS), inductively coupled plasma optical emission spectroscopy (ICP-OES), scanning electron microscopy (SEM), and synchrotron micro-scale x-ray fluorescence (μ-XRF). Within a period of 16 weeks, hydrogen sulfide (H 2 S) was generated in systems containing both H 2 and shale. XRF mapping identified a zone enriched in iron(II) and reduced sulfur along the rim of cement cross sections that was largely associated with CO 2 -induced cement carbonation. Shale did not show noticeable alteration, but there is evidence it contributed to the initial inoculation of the system and provided nutrients for microbes via water-rock interactions. Here, this study considers both rock formations and wellbore cement not previously evaluated concurrently. Findings support understanding and modeling of H 2 -associated biogeochemical reactions during underground hydrogen storage.

36 MATERIALS SCIENCE↗

Production rates of neon xenon isotopes by energetic neutrons

As a first step in an experimental program to study the behavior of noble gases produced in situ in minerals, a suite of minerals and pure chemicals were irradiated with 14.5 MeV neutrons at LLNL's Rotating Target Neutron Source (RTNS-II) and production rates for noble gases were determined. While neutron effects in meteorites and lunar samples are dominated by low-energy neutron capture, more energetic cosmic-ray secondary neutrons can provide significant depth-dependent contributions to production of cosmogenic nuclides through endothermic reactions such as (n,2n), (n,np), (n,d) and (n,alpha). Production rates for nuclides produced by cosmic-ray secondary neutrons are therefore useful in interpreting shielding histories from the relative abundances of cosmogenic nuclides. Absolute production cross sections were calculated from isotope dilution analyses of NaCl, Mg, CsCl, and Ba(NO3)2 samples, assuming purity, stoichiometry, and quantitative noble gas retention and extraction. Relative production cross sections determined from neon isotopic ratios in the mineral samples were also considered in evaluating the neon production cross sections. Results are presented.

Leich, D. A.↗

Chemical and physical studies of type 3 chondrites. XI - Metamorphism, pairing, and brecciation of ordinary chondrites

The present study reports recent measurements of the induced thermoluminescence (TL) properties of 69 type-3 ordinary chondrites, bringing to 125 the number of type-3 ordinary chondrites for which TL data are available. The samples include several of the particularly low petrographic type and many breccias, some of them gas-rich. The significance of the data with respect to the physical conditions affecting metamorphism is discussed. The TL data, olivine heterogeneity, carbon content, and inert-gas content were used to assign the samples to petrologic types. Twelve meteorites were identified as being type 3.0-3.2, and 10 of the breccias were found to contain material that may also be of this type. The temperature and width of the induced TL peak are also related to thermal history, with type 3.2-3.4 chondrites tending to have narrower peaks at lower glow curve temperatures than the type 3.6-3.9 chondrites. Type 3 H chondrites were found to be a higher petrographic type than the type 3 L and LL chondrites.

Sears, D. W. G.↗

The Dual-Rasp Sampling System Design with Closed Pneumatic Sample Transfer

The novel Dual-Rasp sampling system has been developed for landed missions to low gravity planetary bodies and is particularly well suited for the unique environment of Saturn’s moon Enceladus. The Dual-Rasp sampling system has two counter-rotating rasp cutters that remove material from the surface and direct it into a guide. The cuttings follow the guide into a sample collection cup. When the sampling collection completes, the tool reconfigures by rotating the guide to create a closed circuit for pneumatic sample transfer from the collection cup to science instruments on the lander. A valve opens a gas tank and the gas flows from that tank into the sample collection cup and down rigid tubing to the science instruments chamber on the lander. A two degree of freedom arm with base actuators is used to deploy the sampler and control its sampling location.

Heness, Andrew B.↗

Real-time streaming tomographic reconstruction with on-demand data capturing and 3D zooming to regions of interest

Complex dynamic tomographic experiments at brilliant X-ray light sources require real-time feedback on the sample changes with respect to environmental conditions, selecting representative regions of interest for high-resolution scanning, and on-demand data saving mechanisms for storing only relevant projections acquired by fast area detectors and reducing data volumes. Here the implementation details of a 3D real-time imaging monitoring instrument, with zooming to a volume of interest with easy-to-use visualization via ImageJ , a tool familiar to most beamline users, is presented. The instrument relies on optimized data flow between the detector and processing machines and is implemented on commodity computers. The instrument has been developed at beamline 2-BM of the Advanced Photon Source, where the automatic lens changing mechanism for zooming is implemented with an Optique Peter microscope. Performance tests demonstrate the ability to process more than 3 GB of projection data per second and generate real-time 3D zooming with different magnification. These new capabilities are essential for new APS Upgrade instruments such as the projection microscope under development at beamline 32-ID. The efficacy of the proposed instrument was demonstrated during an in situ tomographic experiment on ice and gas hydrate formation in porous samples.

3D zooming↗

Burning characteristics and fiber retention of graphite/resin matrix composites

Graphite fiber reinforced resin matrix composites were subjected to controlled burning conditions to determine their burning characteristics and fiber retention properties. Small samples were burned with a natural gas fired torch to study the effects of fiber orientation and structural flaws such as holes and slits that were machined into the laminates. Larger laminate samples were burned in a modified heat release rate calorimeter. Unidirectional epoxy/graphite and polyimide/graphite composites and boron powder filled samples of each of the two composite systems were burn tested. The composites were exposed to a thermal radiation of 5.3 Btu/sq ft-sec in air. Samples of each of the unfilled composite were decomposed anaerobically in the calorimeter. Weight loss data were recorded for burning and decomposition times up to thirty-five minutes. The effects of fiber orientation, flaws, and boron filler additives to the resins were evaluated. A high char forming polyimide resin was no more effective in retaining graphite fibers than a low char forming epoxy resin when burned in air. Boron powder additions to both the polyimide and the epoxy resins stabilized the chars and effectively controlled the fiber release.

Bowles, K. J.↗

Burning characteristics and fiber retention of graphite/resin matrix composites

Graphite fiber reinforced resin matrix composites were subjected to controlled burning conditions to determine their burning characteristics and fiber retention properties. Two types of burning equipment were used. Small samples were burned with a natural gas fired torch to study the effects of fiber orientation and structural flaws such as holes and slits that were machined into the laminates. Larger laminate samples were burned in a Heat Release Rate Calorimeter. Unidirectional epoxy/graphite and polyimide/graphite composites and boron powder filled samples of each of the two composite systems were burn tested and exposed to a thermal radiation. The effects of fiber orientation, flaws, and boron filler additives to the resins were evaluated. A high char forming polyimide resin was no more effective in retaining graphite fibers than a low char forming epoxy resin when burning in air.

Bowles, K. J.↗

MIS Shelf-Life Final Report for Plutonium Oxide Item CAN92 (SSR147) from Rocky Flats Analytical Laboratory Operations

A plutonium/uranium oxide material from the Material Identification and Surveillance (MIS) Program inventory has been studied to determine the gas generation and corrosion behavior in a storage environment. Sample CAN92 represents plutonium/uranium oxides stored in 3013 containers. The material originated in the analytical laboratory at Rocky Flats. This study followed over time the gas pressure and composition of a sample with nominally 0.5 wt% water in a sealed container with an internal volume scaled to 1/400th of the volume of a 3013 container. Gas compositions had been measured periodically over 5 ½ years. The maximum observed gas pressure from gas generation was 117 kPa. The increase over the initial pressure of 77.5 kPa was largely due to the generation of nitrogen and carbon dioxide with minor amounts of hydrogen and nitrous oxide. The internal components of SSR147 were inspected 6.5 years after it was removed from the array. The inside surfaces of the inner bucket exposed to the original sample for 1,937 days had an etched appearance and general corrosion. No pitting was observed on the inner bucket that held the sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multiplex gas chromatography for use in space craft

Gas chromatography is a powerful technique for the analysis of gaseous mixtures. Some limitations in this technique still exist which can be alleviated with multiplex gas chromatography (MGC). In MGC, rapid multiple sample injections are made into the column without having to wait for one determination to be finished before taking a new sample. The resulting data must then be reduced using computational methods such as cross correlation. In order to efficiently perform multiplexgas chromatography, experiments in the laboratory and on board future space craft, skills, equipment, and computer software were developed. Three new techniques for modulating, i.e., changing, sample concentrations were demonstrated by using desorption, decomposition, and catalytic modulators. In all of them, the need for a separate gas stream as the carrier was avoided by placing the modulator at the head of the column to directly modulate a sample stream. Finally, the analysis of an environmental sample by multiplex chromatography was accomplished by employing silver oxide to catalytically modulate methane in ambient air.

Valentin, J. R.↗

Thermal and Evolved Gas Analysis of Calcite Under Reduced Operating Pressures: Implications for the 2011 MSL Sample Analysis at Mars (SAM) Instrument

The Mars Science Laboratory (MSL) is scheduled for launch in 2011. The science objectives for MSL are to assess the past or present biological potential, to characterize the geology, and to investigate other planetary processes that influence habitability at the landing site. The Sample Analysis at Mars (SAM) is a key instrument on the MSL payload that will explore the potential habitability at the landing site [1]. In addition to searching for organic compounds, SAM will have the capability to characterized evolved gases as a function of increasing temperature and provide information on the mineralogy of volatile-bearing phases such as carbonates, sulfates, phyllosilicates, and Fe-oxyhydroxides. The operating conditions in SAM ovens will be maintained at 30 mb pressure with a He carrier gas flowing at 1 sccm. We have previously characterized the thermal and evolved gas behaviors of volatile-bearing species under reduced pressure conditions that simulated operating conditions of the Thermal and Evolved Gas Analyzer (TEGA) that was onboard the 2007 Mars Phoenix Scout Mission [e.g., 2-8]. TEGA ovens operated at 12 mb pressure with a N2 carrier gas flowing at 0.04 sccm. Another key difference between SAM and TEGA is that TEGA was able to perform differential scanning calorimetry whereas SAM only has a pyrolysis oven. The operating conditions for TEGA and SAM have several key parameter differences including operating pressure (12 vs 30 mb), carrier gas (N2 vs. He), and carrier gas flow rate (0.04 vs 1 sccm). The objectives of this study are to characterize the thermal and evolved gas analysis of calcite under SAM operating conditions and then compare it to calcite thermal and evolved gas analysis under TEGA operating conditions.

Lauer, H. V. Jr.↗

Influence of elevated temperature and oxygen on the capture of radioactive iodine by silver functionalized silica aerogel

Reprocessing is considered a competent strategy for spent nuclear fuel management, yet radioiodine ( 129 I) is emitted in reprocessing off-gas as a hazardous byproduct. Silver functionalized silica aerogel (Ag 0 -aerogel), a promising iodine capture material, experiences a reduction in its capacity after prolonged exposure to off-gas components at elevated temperatures, a phenomenon termed as aging. To fully understand this process, we isolated the contribution of each aging factor, exposing Ag 0 -aerogel samples to N 2 and dry air gas streams, respectively, at 150 °C for different time periods. Aged samples were loaded with I 2 to examine the capacity change and comprehensively characterized to investigate the evolution of their properties. Results show that temperature alone did not alter Ag 0 -aerogel's capacity but triggered Ag 0 nanoparticles sintering and generated organic sulfur species. The presence of O 2 reduced the capacity by ~20 %, causing (i) formation of silver sulfide (Ag 2 S) crystals and (ii) oxidation of Ag-thiolate (Ag-S-r) to Ag sulfonate (Ag-SO 3 -r). Given that Ag 2 S readily adsorbs I 2 , the formation of Ag-SO 3 -r is the major inhibitor for iodine adsorption. This hypothesis was supported by density functional theory (DFT) simulations. These findings unraveled key mechanisms of Ag 0 -aerogel aging, which are useful in the development of materials that withstand realistic spent-nuclear-fuel-reprocessing off-gas conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Coal Fired Power Plant Configuration and Operation Impact on Plant Effluent Contaminants and Conditions

The primary objective of this project is to characterize coal contaminants in coal-fired power plant wastewater as a function of coal type, unit configurations, and unit operation profile with uncertainty analysis. This project was in response to the U.S. Department of Energy (DOE) Solicitation DE-FOA-0001842. The project duration was between September 01, 2018, and December 31, 2021 (no-cost extension filed, due to the Covid-19 pandemic restrictions, and approved). Field and lab test program was conducted with the main goal to characterize coal contaminants in coal-fired power plant wastewater as a function of coal type, unit configurations, and unit operation profile with uncertainty analysis. In this project, the team of Lehigh University (prime recipient) and Western Kentucky University identified two suitable Thermoelectric Power Plants (TTPs) firing bituminous and sub-bituminous coals respectively, designed test plans, and performed sample collection. Sampling included coal from each TTPs power generation units, Wet Flue Gas Desulfurization (WFGD) slurry material and waste-water samples taken from the outlet of the water treatment tank prior to discharge and other pertinent locations. Coal samples are dried, crushed, and pulverized according to the American Society for Testing and Materials (ASTM) methods. The prepared coal samples are analyzed for normal proximate and ultimate analysis tests in addition to the toxic metals and anions according to ASTM methods. The FGD slurry materials are analyzed for toxic metals and anions according to Electric Power Research Institute (EPRI) or Environmental Protection Agency (EPA) methods, as appropriate. The wastewater samples from the water treatment tank outlet are analyzed for toxic metals and anions according to EPA methods. The effluent species analyzed include mercury, arsenic, selenium, nitrate/nitrite, bromide, and chlorine. This project provided results of effluent conditions as a function of coal type, unit configuration, and unit operation profile, and identified the levels of uncertainty in the effluent results.

01 COAL, LIGNITE, AND PEAT↗

Investigating In-Situ Fracture Behaviors of Polymer Pipeline Materials in Hydrogen and Hydrogen-Methane Blended Gas Environments

To reduce carbon emissions, the US natural gas infrastructure is seen as a primary solution for efficiently transporting hydrogen gas. Blending hydrogen gas with natural gas and transporting it across a national infrastructure could save significant infrastructure costs. To properly operate the infrastructure under the new gas system, it is critical to understand material compatibility with hydrogen under various conditions. The Blended Gas CRADA, a Hyblend project, is established to determine the material compatibility of existing natural gas pipes with hydrogen gas. In this study, we investigate the in-plane fracture behaviors of MDPEMarlex and HDPEGDB exposed to hydrogen and hydrogen-methane blended gas. Single-edge notch bending geometry is used. All tests are executed in-situ with the gas environment. The experimental results show a significant effect of the gas environment on HDPEGDB specimens, reducing 5% (H2) to 42% (Blended gas) of specific fracture energy compared to non-aged specimens. For the MDPEMarlex, the effects of the gas environment have increased the specific fracture energy by 10% (H2) to 15% (Blended gas). Fracture surfaces of the tested samples are observed using an electronic microscope. The in-plane fracture surface of HDPEGDB shows a pronounced dimple fracture pattern after exposure to hydrogen and blended gas. The expanded fracture pattern contributes to lower the specific fracture energy. These observations provide critical information for validating polymer pipeline materials when interact with hydrogen and hydrogen-blend gas.

Ko, Seunghyun↗

The Viking biological investigation - Preliminary results

A preliminary progress report is presented for the Viking biological investigation through its first month. The carbon assimilation, gas exchange, and labeled release experiments are described in detail, and the chronology of the experiments is outlined. For the first experiment, it is found that a small amount of gas was converted into organic material in one sample and that heat treatment of a duplicate sample prevented such conversion. In the second experiment, a substantial amount of O2 was detected along with significant increases in CO2 and small changes in N2. In the third experiment, a significant amount of radioactive gas was evolved from one sample, but not from a duplicate heat-treated sample. Possible biological and nonbiological interpretations are considered for these results. It is concluded that while the experiments provide clear evidence for the occurrence of chemical reactions and while the results do not violate any prima facie criteria for biological processes, a definitive answer cannot yet be given to the question of whether life exists on Mars.

Klein, H. P.↗

Interchange for Joint Research Entitled: Measurement of Stable Nitrogen and Sulfur Isotopes

Viking measurements of the Martian atmosphere indicate a value of N-15/N-14 which is markedly greater than that found in Earth's atmosphere. These isotopic measurements provide a powerful diagnostic tool which may be used to derive valuable information regarding the past history of Mars and they have been used to place important constraints on the evolution of Mars' atmosphere. Initial partial pressures of nitrogen, outgassing rates, and integrated deposition of nitrogen into minerals have been calculated from this important atmospheric data (McElroy et al., 1976 and 1977; Fox and Dalgarno, 1983). The greater precision obtained in laser spectrometer isotopic measurements compared to the Viking data will greatly improve these calculated values. It has also been proposed that the N-15/N-14 value in Mars' atmosphere has increased monotonically over time (McElroy et al., 1977; Fox and Dalgarno, 1983; Wallis, 1989) owing to preferential escape of atmospheric 14N to space. Nitrogen isotopic ratios might be used to identify relatively ancient crustal rocks (R. Mancinelli, personal communication), and perhaps determine relative aces of surface samples. As a first step in successfully measuring nitrogen isotopes optically we have demonstrated the measurement of 15NI14N to a precision of 0.1% (See Figures 1-4) using a tunable diode laser and an available gas (N-,O) with spectral lines in the 2188 cm-1 region. The sample and reference gas cells contained gases of identical isotopic composition so that the 15NI14N absorption ratio determined from the sample cell, when divided by the 15NI14N absorption ratio determined from the reference cell, should yield an ideal value of unity. The average measured value of this "ratio of ratios" was 0.9983 with a standard deviation (20 values) of 0.0010. This corresponds to a precision of 0.1% (1 per mil) for nitrogen isotopes, a value sufficiently precise to provide important isotopic data of interest to exobiologists. The precision presently attainable in gases is sufficient to permit the instrument to be used in the measurement of isotopic ratios of interest to exobiologists as well as geologists and planetary scientists.

Becker, Joseph F.↗

MIS Shelf-Life Final Report for Plutonium Oxide Item 1000089 (SSR136 and SSR136A) from Rocky Flats Peroxide Precipitation and Calcination Process

A plutonium dioxide material from the Material Identification and Surveillance (MIS) Program inventory has been studied to determine the gas generation and corrosion behavior in a storage environment. Sample 1000089 represents product-quality plutonium oxides produced in the Rocky Flats peroxide precipitation process currently stored in 3013 containers. This study followed over time the gas pressure and composition of a sample with nominally 0.5 wt% water in a sealed container with an internal volume scaled to 1/500th of the volume of a 3013 container. Gas compositions had been measured periodically over almost 13 years. The maximum observed gas pressure was 204 kPa and was related to a temperature excursion. The maximum observed gas pressure from gas generation was 126 kPa. The increase over the initial pressure of 86.7 kPa was due to the generation of hydrogen, oxygen, and nitrogen. Carbon dioxide, methane and carbon monoxide were minor components of the headspace gas. The material exhibited unusual behavior in that the atmosphere reached flammable levels of hydrogen and oxygen within the first 30 days and remained flammable for the duration of the experiment. It has been determined that the sample inside the reactor was a mixture of the AR material, material calcined at 800 °C, and material calcined at 950 °C. The experiment was terminated in 2012 and unloaded in 2016. A new reactor, SSR136A, was loaded with the original sample freshly calcined at 950 °C. The total pressure inside SSR136A remained close to the initial value of 93 kPa. The total pressure is composed of He (steady levels after the reloading) and hydrogen which is 10% of the reactor’s total pressure. Nitrogen and oxygen compose trace amounts of the reactor headspace. The internal components of SSR136 were inspected in 2021, five years after it was removed from the array. The inside surfaces of the inner bucket exposed to the original sample for 4,576 days had an etched appearance, and pit-like features were observed in the microscopic analysis. No corrosion was observed on the SSR136A inner bucket that held the freshly calcined sample that was exposed for 1,303 days.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Beagle 2: The Next Exobiology Mission to Mars

Beagle 2 is a 60 kg probe (with a 30 kg lander) developed in the United Kingdom for inclusion on the European Space Agency's 2003 Mars Express. Beagle 2 will deliver to the Martian surface a payload which consists of a high percentage of science instruments to landed spacecraft mass. Beagle 2 will be launched in June, 2003 with Mars Express on a Soyuz-Fregat rocket from the Baikonur Cosmodrome in Kazakhstan. Beagle 2 will land on Mars on December 26, 2003 in the Isidis Planitia basin (approximately 10 degrees N and 275 degrees W), a large sedimentary basin that overlies the boundary between ancient highlands and northern plains. Isidis Planitia, the third largest basin on Mars, which is possibly filled with sediment deposited at the bottom of long-standing lakes or seas, offers an ideal environment for preserving traces of life. Beagle 2 was developed to search for organic material and other volatiles on and below the surface of Mars in addition to the study of the inorganic chemistry and mineralogy. Beagle 2 will utilize a mechanical mole and grinder to obtain samples from below the surface, under rocks and inside rocks. A pair of stereo cameras will image the landing site along with a microscope for examination of surface and rock samples. Analyses will include both rock and soil samples at various wavelengths, X-ray spectrometer and Mossbauer spectrometer as well as a search for organics and other light element species (e.g. carbonates and water) and measurement of their isotopic compositions. Beagle 2 has as its focus the goal of establishing whether evidence for life existed in the past on Mars at the Isidis Planitia site or at least establishing if the conditions were ever suitable. Carbonates and organic components were first recognized as existing on Mars when they were found in the Martian meteorite Nakhla. Romanek et al showed the carbonates in ALH84001 were formed at low temperatures. McKay et al noted possible evidence of early life on Mars within the ALH84001 meteorite. Thomas-Keprta et al showed the magnetite biomarkers in ALH84001's carbonates are indistinguishable from those formed by magnetotactic bacteria found on Earth. Gibson et al showed there was significant evidence for liquid water and biogenic products present on Mars across a 3.9 billion year period. A mechanical arm (PAW) operates from the lander and is used for science operations along with sample acquisition. Instruments attached to the PAW include: stereo cameras, Mossbauer instrument, X-ray fluorescence instrument, microscope, environmental sensors, rock corer/grinder, a spoon, mirror, brushes, a mole attachment for acquisition of subsurface to depths of 1 to 2 meters and an illumination device. Each camera has 14 filters which have been optimized for mineralogy composition, dust and water vapor detection. The microscope's camera is designed for viewing the size and shape of dust particles, rock surfaces, microfossils, and characteristics of the samples prior to introduction into the gas analysis package (GAP). The camera has a resolution of 4 microns/pixel, features four color capability (red, green, blue and UV (ultraviolet) fluoresence), a depth of focus of 40 micrometers and translation stage of +3 millimeters. The heart of the Beagle 2's life detection package is the gas analysis package (GAP), which consists of a mass spectrometer with collectors at fixed masses for precise isotopic ratio measurements and voltage scanning for spectral analysis. Primary aim of the GAP is to search for the presence of bulk constituents, individual species, and isotopic fractionations for both extinct and extent life along with studying the low-temperature geochemistry of the hydrogen, carbon, nitrogen and oxygen components on Mars from both the surface and atmosphere. GAP is a magnetic sector mass spectrometer with the range of 1 to 140 amu which can be operated in both the static and dynamic modes. A triple Faraday collector array will be used for C, N and O ratios along with a double Faraday array for H/D. Pulse counting electron multiplier will be utilized for noble gases and selected organics. Anticipated detection limits are at the picomole level for operation in the static mode of operation and high precision isotopic measurements will be made in the dynamic mode. Sample processing and preparation system consists of reaction vessels along with references. Sample ovens capable of being heated are attached to the manifold for sample combustion. Surface, subsurface materials and interior rock specimens will be combusted in pure oxygen gas at various temperature intervals to release organic matter and volatiles. Combustion process will permit detection of all forms and all atoms of carbon present in the samples. A chemical processing system is capable of a variety of conversion reactions. Gases are manipulated either by cryogenic or chemical reactions and passed through the gas handling portion of the vacuum system. There are two modes of operation: quantitative analysis and precise isotopic measurements. Additional information is contained in the original extended abstract.

Gibson, Everett K., Jr.↗

Design of a sample acquistion system for the Mars exobiological penetrator

The Mars Exobiological Penetrator will be imbedded into several locations on the Martian surface. It contains various scientific instruments, such as an Alpha-Particle Instrument (API), Differential Scanning Calorimeter (DSC), Evolved Gas Analyzer (EGA) and accelerometers. A sample is required for analysis in the API and DSC. To avoid impact contaminated material, this sample must be taken from soil greater than 2 cm away from the penetrator shell. This study examines the design of a dedicated sampling system including deployment, suspension, fore/after body coupling, sample gathering and placement. To prevent subsurface material from entering the penetrator sampling compartment during impact, a plug is placed in the exit hole of the wall. A U-lever device is used to hold this plug in the penetrator wall. The U-lever rotates upon initial motion of the core-grinder mechanism (CGM), releasing the plug. Research points to a combination of coring and grinding as a plausible solution to the problem of dry drilling. The CGM, driven by two compressed springs, will be deployed along a tracking system. A slowly varying load i.e., springs, is favored over a fixed displacement motion because of its adaptability to different material hardness. However, to accommodate sampling in a low density soil, two dash pots set a maximum transverse velocity. In addition, minimal power use is achieved by unidirectional motion of the CGM. The sample will be transported to the scientific instruments by means of a sample placement tray that is driven by a compressed spring to avoid unnecessary power usage. This paper also explores possible modifications for size, weight, and time as well as possible future studies.

Thomson, Ron↗