Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Functionally Graded”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Target Control and Protection Systems Lessons from SNS Operations

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory has been in operations since 2006 and proposes a project to build a Second Target Station (STS) to effectively double potential scientific output. The SNS target controls operate in a harsh environment which includes high radiation, exposure to gaseous radionuclides, and activated liquid mercury and mercury vapor. These conditions necessitate protective interlocks and credited controls for protection functions to ensure proper response to off-normal conditions. In order to inform the design of target controls for the STS, we have examined lessons learned during SNS operations regarding the design and implementation of the control and protection systems for the first target station (FTS). This paper will examine various aspects of the performance of the target control and protection systems including reliability, maintainability and sustainability given the challenging environment created by 1.4 MW operations. Specific topics include distributed control of various target subsystems, response to loss of power, selection of nuclear grade instrumentation, and applying these lessons to the design for the STS project.

Humphreys, Dana↗

Biomarkers, Proteoforms, and Mass Spectrometry–Based Assays for Diabetes Clinical Research

Abstract The prevalence of diabetes, particularly type 2 diabetes, has reached epidemic proportions globally. The number of patients with type 1 diabetes (T1D) is also increasing rapidly. Despite advancements in understanding the pathogenesis of diabetes, the lack of circulating pancreatic biomarkers and reliable clinical-grade assays remains a major gap in diabetes research, often hindering the ability to adequately assess disease progression and therapeutic responses. This mini-review discusses emerging pancreatic biomarkers, with an emphasis on T1D, the limitations of current immunoassays, and the expanding role of mass spectrometry–based assays. Highlights include the recent work within the NIDDK-funded “Targeted Mass Spectrometry Assays for Diabetes and Obesity Research (TaMADOR)” consortium, which aims to develop robust, quantitative, and transferable assays for translational research. The review also emphasizes the importance of proteoform-specific assays for monitoring pancreatic function, including prohormone processing during disease progression or in responses to therapy.

Endocrinology & Metabolism↗

RTN-095: The Vera C. Rubin Observatory Data Preview 1

We present Rubin Data Preview 1 (DP1), the first release of data from the NSF-DOE Vera C. Rubin Observatory, consisting of raw and calibrated single-epoch images, coadds, difference images, detection catalogs, and other derived data products. DP1 is based on 1792 science-grade optical/near-infrared exposures acquired over 48 distinct nights by the Rubin Commissioning Camera, LSSTComCam, on the Simonyi Survey Telescope at the Summit Facility on Cerro Pachón, Chile during the first on-sky commissioning campaign in late 2024. DP1 covers a total of ~15 sq. deg. over seven roughly equally-sized non-contiguous fields, each independently observed in six broad photometric bands, ugrizy, spanning a range of stellar densities and latitudes and overlapping with external reference datasets. The median image quality across all bands, measured by the FWHM of the point-spread function, is approximately 1.13 arcseconds, with the sharpest images reaching about 0.65 arcseconds. DP1 contains approximately 2.3 million distinct astrophysical objects, of which 1.6 million are extended in at least one band, and 431 solar system objects, of which 93 are new discoveries. DP1 is approximately 3.5 TB in size and available to Rubin data rights holders via the Rubin Science Platform, a cloud-based environment for the analysis of petascale astronomical data. While small compared to future LSST releases, its high quality and diversity of data support a broad range of early science investigations across all four LSST themes, providing a valuable opportunity to engage with Rubin data ahead of the start of full operations in late 2025.

79 ASTRONOMY AND ASTROPHYSICS↗

Epitaxial solar cells fabrication

Silicon epitaxy has been studied for the fabrication of solar cell structures, with the intent of optimizing efficiency while maintaining suitability for space applications. SiH2CL2 yielded good quality layers and junctions with reproducible impurity profiles. Diode characteristics and lifetimes in the epitaxial layers were investigated as a function of epitaxial growth conditions and doping profile, as was the effect of substrates and epitaxial post-gettering on lifetime. The pyrolytic decomposition of SiH4 was also used in the epitaxial formation of highly doped junction layers on bulk Si wafers. The effects of junction layer thickness and bulk background doping level on cell performance, in particular, open-circuit voltage, were investigated. The most successful solar cells were fabricated with SiH2 CL2 to grow p/n layers on n(+) substrates. The best performance was obtained from a p(+)/p/n/n(+) structure grown with an exponential grade in the n-base layer.

Daiello, R. V.↗

Functional Polymorphisms of Base Excision Repair Genes XRCC1 and APEX1 Predict Risk of Radiation Pneumonitis in Patients With Non-Small Cell Lung Cancer Treated With Definitive Radiation Therapy

Purpose: To explore whether functional single nucleotide polymorphisms (SNPs) of base-excision repair genes are predictors of radiation treatment-related pneumonitis (RP), we investigated associations between functional SNPs of ADPRT, APEX1, and XRCC1 and RP development. Methods and Materials: We genotyped SNPs of ADPRT (rs1136410 [V762A]), XRCC1 (rs1799782 [R194W], rs25489 [R280H], and rs25487 [Q399R]), and APEX1 (rs1130409 [D148E]) in 165 patients with non-small cell lung cancer (NSCLC) who received definitive chemoradiation therapy. Results were assessed by both Logistic and Cox regression models for RP risk. Kaplan-Meier curves were generated for the cumulative RP probability by the genotypes. Results: We found that SNPs of XRCC1 Q399R and APEX1 D148E each had a significant effect on the development of Grade {>=}2 RP (XRCC1: AA vs. GG, adjusted hazard ratio [HR] = 0.48, 95% confidence interval [CI], 0.24-0.97; APEX1: GG vs. TT, adjusted HR = 3.61, 95% CI, 1.64-7.93) in an allele-dose response manner (Trend tests: p = 0.040 and 0.001, respectively). The number of the combined protective XRCC1 A and APEX1 T alleles (from 0 to 4) also showed a significant trend of predicting RP risk (p = 0.001). Conclusions: SNPs of the base-excision repair genes may be biomarkers for susceptibility to RP. Larger prospective studies are needed to validate our findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Protection of Renewable-dominated Microgrids: Challenges and Potential Solutions

In this report we address the challenge of designing efficient protection system for inverter- dominated microgrids. These microgrids are characterised with limited fault current capacity as a result of current-limiting protection functions of inverters. Typically, inverters limit their fault contribution in sub-cycle time frame to as low as 1.1 per unit. As a result, overcurrent protection could fail completely to detect faults in inverter-dominated microgrids. As part of this project a detailed literature survey of existing and proposed microgrid protection schemes were conducted. The survey concluded that there is a gap in the available microgrid protection methods. The only credible protection solution available in literature for low- fault inverter-dominated microgrids is the differential protection scheme which represents a robust transmission-grade protection solution but at a very high cost. Two non-overcurrent protection schemes were investigated as part of this project; impedance-based protection and transient-based protection. Impedance-based protection depends on monitoring impedance trajectories at feeder relays to detect faults. Two communication-based impedance-based protection schemes were developed. the first scheme utilizes directional elements and pilot signals to locate the fault. The second scheme depends on a Central Protection Unit that communicates with all feeder relays to locate the fault based on directional flags received from feeder relays. The later approach could potentially be adapted to protect networked microgrids and dynamic topology microgrids. Transient-based protection relies on analyzing high frequency transients to detect and locate faults. This approach is very promising but its implementation in the filed faces several challenges. For example, high frequency transients due to faults can be confused with transients due to other events such as capacitor switching. Additionally, while detecting faults by analyzing transients could be doable, locating faults based on analyzing transients is still an open question.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protection of Renewable-dominated Microgrids: Challenges and Potential Solutions.

In this report we address the challenge of designing efficient protection system for inverter- dominated microgrids. These microgrids are characterised with limited fault current capacity as a result of current-limiting protection functions of inverters. Typically, inverters limit their fault contribution in sub-cycle time frame to as low as 1.1 per unit. As a result, overcurrent protection could fail completely to detect faults in inverter-dominated microgrids. As part of this project a detailed literature survey of existing and proposed microgrid protection schemes were conducted. The survey concluded that there is a gap in the available microgrid protection methods. The only credible protection solution available in literature for low- fault inverter-dominated microgrids is the differential protection scheme which represents a robust transmission-grade protection solution but at a very high cost. Two non-overcurrent protection schemes were investigated as part of this project; impedance-based protection and transient-based protection. Impedance-based protection depends on monitoring impedance trajectories at feeder relays to detect faults. Two communication-based impedance-based protection schemes were developed. the first scheme utilizes directional elements and pilot signals to locate the fault. The second scheme depends on a Central Protection Unit that communicates with all feeder relays to locate the fault based on directional flags received from feeder relays. The later approach could potentially be adapted to protect networked microgrids and dynamic topology microgrids. Transient-based protection relies on analyzing high frequency transients to detect and locate faults. This approach is very promising but its implementation in the filed faces several challenges. For example, high frequency transients due to faults can be confused with transients due to other events such as capacitor switching. Additionally, while detecting faults by analyzing transients could be doable, locating faults based on analyzing transients is still an open question.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electroless Formation of Hybrid Lithium Anodes for Fast Interfacial Ion Transport

Abstract Rechargeable batteries based on metallic anodes are of interest for fundamental and application‐focused studies of chemical and physical kinetics of liquids at solid interfaces. Approaches that allow facile creation of uniform coatings on these metals to prevent physical contact with liquid electrolytes, while enabling fast ion transport, are essential to address chemical instability of the anodes. Here, we report a simple electroless ion‐exchange chemistry for creating coatings of indium on lithium. By means of joint density functional theory and interfacial characterization experiments, we show that In coatings stabilize Li by multiple processes, including exceptionally fast surface diffusion of lithium ions and high chemical resistance to liquid electrolytes. Indium coatings also undergo reversible alloying reactions with lithium ions, facilitating design of high‐capacity hybrid In‐Li anodes that use both alloying and plating approaches for charge storage. By means of direct visualization, we further show that the coatings enable remarkably compact and uniform electrodeposition. The resultant In‐Li anodes are shown to exhibit minimal capacity fade in extended galvanostatic cycling when paired with commercial‐grade cathodes.

Choudhury, Snehashis↗

Electroless Formation of Hybrid Lithium Anodes for Fast Interfacial Ion Transport

Abstract Rechargeable batteries based on metallic anodes are of interest for fundamental and application‐focused studies of chemical and physical kinetics of liquids at solid interfaces. Approaches that allow facile creation of uniform coatings on these metals to prevent physical contact with liquid electrolytes, while enabling fast ion transport, are essential to address chemical instability of the anodes. Here, we report a simple electroless ion‐exchange chemistry for creating coatings of indium on lithium. By means of joint density functional theory and interfacial characterization experiments, we show that In coatings stabilize Li by multiple processes, including exceptionally fast surface diffusion of lithium ions and high chemical resistance to liquid electrolytes. Indium coatings also undergo reversible alloying reactions with lithium ions, facilitating design of high‐capacity hybrid In‐Li anodes that use both alloying and plating approaches for charge storage. By means of direct visualization, we further show that the coatings enable remarkably compact and uniform electrodeposition. The resultant In‐Li anodes are shown to exhibit minimal capacity fade in extended galvanostatic cycling when paired with commercial‐grade cathodes.

Choudhury, Snehashis↗

First Annual Report on Pulsed Thermal Tomography Nondestructive Evaluation of Additively Manufactured Reactor Materials and Components: Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials and Components

Additive manufacturing (AM, or 3D printing) for commercial nuclear energy applications is an emerging method for cost-efficient manufacturing aimed at replacing aging nuclear reactor parts and reducing costs for new construction. Because of the geometry of metallic structures of interest for nuclear applications, which consist of planar primitives with no symmetry of revolution, limited options are available for nondestructive evaluation (NDE), either during or post manufacturing. Known material flaws in AM include low-density regions consisting of non-sintered powder, which have to be detected to ensure the safety of long-term performance nuclear reactor components. As a solution to NDE of AM, we are developing pulsed thermal tomography (PTT) models and depth inversion algorithms for 3D imaging. PTT has many advantages because the method is non-contact and allows for in-service, NDE of AM nuclear reactor parts. By analyzing transients of surface temperature response due to internal thermal resistances, one can obtain 3D reconstructions of material effusivity using a unique inversion algorithm developed at Argonne. This report provides results of preliminary performance evaluation of PTT capability in detection of flaws in metallic structures, as well imaging complex geometry AM structures. Performance of PTT was investigated through modeling and experiments, Computer models of PTT were developed using COMSOL Heat Transfer module. Defects were modeled as cylindrical flat bottom holes (FBH), which is a common model of calibrated material flaws in thermal tomography experiments. Materials considered in this study include stainless steel 316 (SS316), stainless steel 304 (SS304), and Inconel 718. Theoretical analyses were conducted to validate inversion of simulated PTT data with COMSOL for a plate. Subsequently, 3D reconstructions were performed on COMSOL simulations for FBH, revealing a decrease in spatial resolution over depth due to thermal diffusion. The results of this study show that the performance of the inversion algorithm for detecting smaller defects depends strongly on the depth of the defect as well as the incident heat flux. The size of detectable defect was estimated by fitting a Gaussian function to surface temperature profile. The criteria for detectability was taken as 20mK noise equivalent temperature difference (NETD), which is currently the sensitivity limit of high-performance infrared cameras. It was determined through computer simulations that the smallest detectable FBH in SS316 has a 50µm diameter and is located 0.5mm below the plate surface. Preliminary experimental studies were performed to evaluate PTT performance in detecting calibrated flaws using metallic specimens with AM defects simulated as drilled-in FBH’s. High strength Stainless Steel 316 and Inconel 718 alloys were considered, as well as lower grade Stainless Steel 304, Nickel 200, and Hastelloy C276. Specimens investigated in this report consisted of approximately 1/4in-thick plates made out of these alloys using conventional manufacturing methods. The diameters of FBH’s varied from 1mm to 8mm, and their depths below the plate flat surface varied between 1mm and 6mm. The size of the smallest FBH was limited to 1mm because conventional mechanical drills were used for creating the holes. PTT imaging results have shown that 1mm-diameter FBH located 1mm and 2mm below the surface were detectable. Larger size FBH were detectable at greater depth. For example, 6mm-diameter FBH could be detected at 8mm depth. Image contrast varied slightly between the specimens, with the best reconstructions obtained in SS316 and C276 plates. Finally, PTT capability in imaging several AM structures fabricated from Inconel 718 (IN718) powder feedstock was investigated. The AM structures have complex geometry, but do not have calibrated internal defects. The objective is to determine PTT settings, such as the total integration time, for imaging of representative AM structures. A new FLIR X8500sc IR camera with higher spatial resolution (1280x1024 at 181Hz frame rate) was integrated into the PTT laboratory setup. Software tools were developed to ensure compatibility of new camera files with legacy effusivity reconstruction codes. The new camera was used to obtain 3-D reconstructions of AM IN718 nozzle plate and a particle filter plate. It was shown that PTT can scan through 2/3in-thick Inconel 718 plates in approximately 15s. Several modes of 3-D data visualization were explored, including using ImageJ and MATLAB software packages. The results demonstrate the capability of PTT in 3-D imaging of complex geometry AM structures. Intermediate results demonstrated in this report will be developed further to investigate detection of flaws in AM specimens.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Myotonometry as a Surrogate Measure of Muscle Strength

Space flight-induced muscle atrophy/neuromuscular degradation and the consequent decrements in crew-member performance are of increasing concern as mission duration lengthens, and planetary exploration after extended space flight is planned. Pre- to post-flight strength measures have demonstrated that specific countermeasures, such as resistive exercise, are effective at countering microgravity-induced muscle atrophy and preventing decrements in muscle strength. However, in-flight assessment/monitoring of exercise countermeasure effectiveness will be essential during exploration class missions due to their duration. The ability to modify an exercise countermeasure prescription based on such real-time information will allow each individual crew member to perform the optimal amount and type of exercise countermeasure to maintain performance. In addition, such measures can be used to determine if a crew member is physically capable of performing a particular mission-related task during exploration class missions. The challenges faced in acquiring such data are those common to all space operations, namely the requirement for light-weight, low power, mechanically reliable technologies that make valid measurements in microgravity, in this case of muscle strength/neuromuscular function. Here we describe a simple, light-weight, low power, non-invasive device, known as the Myotonometer, that measures tissue stiffness as an indirect measure of muscle contractile state and muscle force production. Repeat myotonometer measurements made at the same location on the surface of the rectis femoris muscle (as determined using a 3D locator device, SEM plus or minus 0.34 mm) were shown to be reproducible over time at both maximal voluntary contraction (MVC) and at rest in a total of 17 sedentary subjects assessed three times over a period of seven days. In addition, graded voluntary isometric force production (i.e. 20%, 40%, 60%, 80% & 100% of MVC) during knee extension was shown to be significantly (p less than 0.01) correlated with contemporaneous myotonometer measurements made on the rectis femoris muscle in a total of 16 healthy subjects (8 males, 8 females). Further-more, this device has been operationally tested during parabolic flight demonstrating its suitability for use in a microgravity environment. Our data indicates that the Myotonometer is a viable surrogate measure of muscle contractile state/tone and of muscle strength/force production. Additional studies are required to assess the suitability of this technique for assessing these measures in de-conditioned subjects such as crew-members.

Ang, B. S.↗

A Phase II Study of Radiotherapy and Concurrent Paclitaxel Chemotherapy in Breast-Conserving Treatment for Node-Positive Breast Cancer

Purpose: Administering adjuvant chemotherapy before breast radiotherapy decreases the risk of systemic recurrence, but delays in radiotherapy could yield higher local failure. We assessed the feasibility and efficacy of placing radiotherapy earlier in the breast-conserving treatment course for lymph node-positive breast cancer. Methods and Materials: Between June 2000 and December 2004, 44 women with node-positive Stage II and III breast cancer were entered into this trial. Breast-conserving surgery and 4 cycles of doxorubicin (60 mg/m{sup 2})/cyclophosphamide (600 mg/m{sup 2}) were followed by 4 cycles of paclitaxel (175 mg/m{sup 2}) delivered every 3 weeks. Radiotherapy was concurrent with the first 2 cycles of paclitaxel. The breast received 39.6 Gy in 22 fractions with a tumor bed boost of 14 Gy in 7 fractions. Regional lymphatics were included when indicated. Functional lung volume was assessed by use of the diffusing capacity for carbon monoxide as a proxy. Breast cosmesis was evaluated with the Harvard criteria. Results: The 5-year actuarial rate of disease-free survival is 88%, and overall survival is 93%. There have been no local failures. Median follow-up is 75 months. No cases of radiation pneumonitis developed. There was no significant change in the diffusing capacity for carbon monoxide either immediately after radiotherapy (p = 0.51) or with extended follow-up (p = 0.63). Volume of irradiated breast tissue correlated with acute cosmesis, and acute Grade 3 skin toxicity developed in 2 patients. Late cosmesis was not adversely affected. Conclusions: Concurrent paclitaxel chemotherapy and radiotherapy after breast-conserving surgery shortened total treatment time, provided excellent local control, and was well tolerated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

GenomeFace v1.0

GenomeFace is meta-genome binning software. Metagenomic binning, the process of grouping DNA sequences into taxonomic units, is critical for understanding the functions, interactions, and evolutionary dynamics of microbial communities. We propose a deep learning approach to binning using two neural networks, one based on composition and another on environmental abundance, dynamically weighting the contribution of each based on characteristics of the input data. Trained on over 43,000 prokaryotic genomes, our network for composition-based binning is inspired by metric learning techniques used for facial recognition. Using a task-specific, multi-GPU accelerated algorithm to cluster the embeddings produced by our network, our binner leverages marker genes observed to be universally present in nearly all taxa to grade and select optimal clusters of sequences from a hierarchy of candidates. We evaluate our approach on four simulated datasets with known ground truth. Our linear time integration of marker genes recovers more near complete genomes than state of the art but computationally infeasible solutions using them, while being over an order of magnitude faster. Finally, we demonstrate the scalability and acuity of our approach by testing it on three of the largest metagenome assemblies ever performed. Compared to other binners, we produced 47%-183% more near complete genomes. From these datasets, we find over the genomes of over 3000 new candidate species which have never been previously cataloged, representing a potential 4% expansion of the known bacterial tree of life.

Lettich, Richard [Lawrence Berkeley National Labor↗

Operation and Process Control Development for a Pilot-Scale Leaching and Solvent Extraction Circuit Recovering Rare Earth Elements From Coal-Based Sources

The US Department of Energy in 2010 has identified several rare earth elements as critical materials to enable clean technologies. As part of ongoing research in REEs (rare earth elements) recovery from coal sources, the University of Kentucky has designed, developed and is demonstrating a ¼ ton/hour pilot-scale processing plant to produce high-grade REEs from coal sources. Due to the need to control critical variables (e.g. pH, tank level, etc.), process control is required. To ensure adequate process control, a study was conducted on leaching and solvent extraction control to evaluate the potential of achieving low-cost REE recovery in addition to developing a process control PLC system. The overall operational design and utilization of Six Sigma methodologies is discussed. Further, the application of the controls design, both procedural and electronic for the control of process variables such as pH is discussed. Variations in output parameters were quantified as a function of time. Data trends show that the mean process variable was maintained within prescribed limits. Future work for the utilization of data analysis and integration for data-based decision-making will be discussed.

coal, rare earth elements, pilot plant, automation↗

Identification and Selection of Major Carbon Dioxide Stream Compositions

A critical component in the assessment of long-term risk from geologic sequestration of CO2 is the ability to predict mineralogical and geochemical changes within storage reservoirs due to rock-brine-CO2 reactions. Impurities and/or other constituents selected for co-sequestration can affect both the chemical and physical (e.g. density, viscosity, interfacial tension) behavior of CO2 in the deep subsurface. These impurities and concentrations are a function of both the industrial source(s) of the CO2, as well as the carbon capture technology used to extract the CO2 and produce a concentrated stream for geologic sequestration. This report summarizes the relative concentrations of CO2 and other constituents in exhaust gases from major non-energy related industrial sources of CO2. Assuming that carbon-capture technology would remove most of the incondensable gases N2, O2, and Ar, leaving SO2 and NOx as the main impurities, we selected four test fluid compositions for use in geochemical experiments. These included: 1) a pure CO2 stream representative of food grade CO2 used in most enhanced oil recovery projects: 2) a test fluid composition containing low concentrations (0.5 mole %) SO2 and NOx (representative of that generated from cement production), 3) a test fluid composition with higher concentrations (2.5 mole %) of SO2, and 4) and test fluid composition containing 3 mole % H2S.

54 ENVIRONMENTAL SCIENCES↗

An Effective Purification Process for the Nuclear Radiation Detector Tl 6 SeI 4

The semiconductor Tl6SeI4 was previously identified as a promising semiconductor for room temperature nuclear radiation detection. As the detection performance and carrier transport strongly depend on the concentration of impurity energy levels acting as scattering centers and carrier trapping, material purification is a crucial prerequisite step to obtain spectroscopic-grade detector performance. In this contribution, we present a highly efficient purification method using a bent ampule for evaporating Se, Tl2Se, and TlI precursors for Tl6Se4. On the basis of impurity analysis performed by glow discharge mass spectroscopy, the main impurities in Tl2Se were identified to be Pb, Bi, and Al, while in TlI the main impurities are Al and Sn. The bent-ampule method successfully reduces or removes the Cl, Pb, and Te impurities from the Se precursor, the Pb, Bi, and Al impurities from the Tl2Se precursor, and removes Sn from TU. Informed by the analysis results, density functional theory calculations were performed to study the identified impurities and related defects. The calculation results show that Bi and Al act as deep defect levels, which can be detrimental to the detector performance of Tl6SeI4. If the growth condition of Tl6SeI4 is Tl-rich/Se-poor, impurity of Si can introduce deep donors. However, it becomes electrically benign if growth conditions are Tl-poor/Se-rich, while Sn and Pb impurities are shallow donors. Centimeter-size Tl6SeI4 crystals were grown by the two-zone vertical Bridgman method using the purified precursors. The detector made of Tl6SeI4 crystal maintains the high resistivity on the order of 10(11) Omega.cm after purification, ideal for suppressing leakage current. The detector exhibits both full-energy and Tl escape photopeaks upon 122 keV gamma-ray from Co-57 radiation source. The electron mobility-lifetime product mu(e)tau(e) for TI6SeI4 detector is 8.1 X 10(-5) cm(2).V-1. On the basis of the carrier rise time measured from output pulses induced by 5.5 MeV alpha-particles from Am-241, the electron and hole mobilities were estimated to be 112 +/- 22 and 81 +/- 16 cm(2).V-1.s(-1), respectively, comparable to those of the leading detector materials HgI2 and TlBr. These results validate the potential of this compound for hard radiation detection, and the impurity analysis presented here allows future efforts to focus on reducing the concentration of the identified impurities.

Lin, Wenwen (ORCID:0000000216279558)↗

Pulmonary Changes After Radiotherapy for Conservative Treatment of Breast Cancer: A Prospective Study

Purpose: Radiotherapy (RT) after conservative surgery for breast cancer involves part of the pulmonary parenchyma with a potential detrimental effect of reducing the normal functional reserve. Such an effect deserves to be studied in depth, considering the given long life expectancy of these women. We prospectively analyzed high-resolution computed tomography (HRCT) and pulmonary function tests (PFTs) with correlation with dosimetric data from RT. Methods and Materials: Lung HRCT and PFTs were performed in 41 women who had undergone conservative surgery for breast cancer before and 3 and 9 months after postoperative RT. The PFTs included forced vital capacity, forced expiratory volume in 1 s, total lung capacity, maximal expiratory flow at 50% and 25% of vital capacity, and the diffusion capacity of carbon monoxide. HRCT was matched with the RT treatment plan images to analyze the dosimetric correlation. Results: At 3 months after RT, the lung alterations were classified at HRCT as follows: 46.3% were Grade 1, 24.4% Grade 2, and 7.3% Grade 3, and at 9 months, 58.5% were Grade 1, 19.5% Grade 2, and 0% Grade 3. The PFTs showed a significant decrease at 3 months, with only partial recovery at 9 months. Chemotherapy, but not hormonal therapy, was associated with PFT changes. The grade of fibrosis increased with increasing lung volume treated to a dose {>=}25 Gy. Conclusion: Lung changes, mainly related to damage to the alveolar-capillary barrier and smallest airway ramifications, were observed at 3 months, with only partial recovery at 9 months after RT. Minimizing the lung volume receiving {>=}25 Gy could reduce pulmonary toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray imaging performance of scintillator-filled silicon pore arrays

The need for fine detail visibility in various applications such as dental imaging, mammography, but also neurology and cardiology, is the driver for intensive efforts in the development of new x-ray detectors. The spatial resolution of current scintillator layers is limited by optical diffusion. This limitation can be overcome by a pixelation, which prevents optical photons from crossing the interface between two neighboring pixels. In this work, an array of pores was etched in a silicon wafer with a pixel pitch of 50 {mu}m. A very high aspect ratio was achieved with wall thicknesses of 4-7 {mu}m and pore depths of about 400 {mu}m. Subsequently, the pores were filled with Tl-doped cesium iodide (CsI:Tl) as a scintillator in a special process, which includes powder melting and solidification of the CsI. From the sample geometry and x-ray absorption measurement the pore fill grade was determined to be 75%. The scintillator-filled samples have a circular active area of 16 mm diameter. They are coupled with an optical sensor binned to the same pixel pitch in order to measure the x-ray imaging performance. The x-ray sensitivity, i.e., the light output per absorbed x-ray dose, is found to be only 2.5%-4.5% of a commercial CsI-layer of similar thickness, thus very low. The efficiency of the pores to transport the generated light to the photodiode is estimated to be in the best case 6.5%. The modulation transfer function is 40% at 4 lp/mm and 10%-20% at 8 lp/mm. It is limited most likely by the optical gap between scintillator and sensor and by K-escape quanta. The detective quantum efficiency (DQE) is determined at different beam qualities and dose settings. The maximum DQE(0) is 0.28, while the x-ray absorption with the given thickness and fill factor is 0.57. High Swank noise is suspected to be the reason, mainly caused by optical scatter inside the CsI-filled pores. The results are compared to Monte Carlo simulations of the photon transport inside the pore array structure. In addition, some x-ray images of technical and anatomical phantoms are shown. This work shows that scintillator-filled pore arrays can provide x-ray imaging with high spatial resolution, but are not suitable in their current state for most of the applications in medical imaging, where increasing the x-ray doses cannot be tolerated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗