Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flow battery”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

885 records · Page 50

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Series-Connected Buck Boost Regulators

A series-connected buck boost regulator (SCBBR) is an electronic circuit that bucks a power-supply voltage to a lower regulated value or boosts it to a higher regulated value. The concept of the SCBBR is a generalization of the concept of the SCBR, which was reported in "Series-Connected Boost Regulators" (LEW-15918), NASA Tech Briefs, Vol. 23, No. 7 (July 1997), page 42. Relative to prior DC-voltage-regulator concepts, the SCBBR concept can yield significant reductions in weight and increases in power-conversion efficiency in many applications in which input/output voltage ratios are relatively small and isolation is not required, as solar-array regulation or battery charging with DC-bus regulation. Usually, a DC voltage regulator is designed to include a DC-to-DC converter to reduce its power loss, size, and weight. Advances in components, increases in operating frequencies, and improved circuit topologies have led to continual increases in efficiency and/or decreases in the sizes and weights of DC voltage regulators. The primary source of inefficiency in the DC-to-DC converter portion of a voltage regulator is the conduction loss and, especially at high frequencies, the switching loss. Although improved components and topology can reduce the switching loss, the reduction is limited by the fact that the converter generally switches all the power being regulated. Like the SCBR concept, the SCBBR concept involves a circuit configuration in which only a fraction of the power is switched, so that the switching loss is reduced by an amount that is largely independent of the specific components and circuit topology used. In an SCBBR, the amount of power switched by the DC-to-DC converter is only the amount needed to make up the difference between the input and output bus voltage. The remaining majority of the power passes through the converter without being switched. The weight and power loss of a DC-to-DC converter are determined primarily by the amount of power processed. In the SCBBR, the unswitched majority of the power is passed through with very little power loss, and little if any increase in the sizes of the converter components is needed to enable the components to handle the unswitched power. As a result, the power-conversion efficiency of the regulator can be very high, as shown in the example of Figure 1. A basic SCBBR includes a DC-to-DC converter (see Figure 2). The switches and primary winding of a transformer in the converter is connected across the input bus, while the secondary winding and switches are connected in series with the output bus, so that the output voltage is the sum of the input voltage and the secondary voltage of the converter. In the breadboard SCBBR, the input voltage applied to the primary winding is switched by use of metal oxide/semiconductor field-effect transistors (MOSFETs) in a full bridge circuit; the secondary winding is center-tapped, with two MOSFET switches and diode rectifiers connected in opposed series in each leg. The sets of opposed switches and rectifiers are what enable operation in either a boost or a buck mode. In the boost mode, input voltage and current, and the output voltage and current are all positive; that is, the secondary voltage is added to the input voltage and the net output voltage can be regulated at a value equal or greater than the input voltage. In the buck mode, input voltage is still positive and the current still flows in the same direction in the secondary, but the switches are controlled such that some power flows from the secondary to the primary. The voltage across the secondary and the current into the primary are reversed. The result is that the output voltage is lower than the input voltage, and some power is recirculated from the converter secondary back to the input. Quantitatively, the advantage of an SCBBR is a direct function of the regulation range required. If, for example, a regulation range of 20 percent is required for a 500-W supply, th it suffices to design the DC-to-DC converter in the SCBBR for a power rating of only 100 W. The switching loss and size are much smaller than those of a conventional regulator that must be rated for switching of all 500 W. The reduction in size and the increase in efficiency are not directly proportional to switched-power ratio of 5:1 because the additional switches contribute some conduction loss and the input and output filters must be larger than those typically required for a 100-W converter. Nevertheless, the power loss and the size can be much smaller than those of a 500-W converter.

Birchenough, Arthur G.↗

DOE EV Data Collection - Charging Data

Charging data are collected from one of three sources, each with varying levels of additional information. These sources, in approximate order from most to least additional information, are: • The electric vehicle supply equipment (charger) • Onboard the vehicle itself • From a utility submeter. Many chargers provide software that allows for the collection and reporting of charging session data. If unavailable, data may be recorded by the charging vehicle’s onboard systems. If neither of these options is available, data can be acquired from utility submeters that simply track the energy flowing to one or more chargers. Data collected directly from the electric vehicle supply equipment (EVSE) are typically the most accurate and highest frequency. However, it is not always possible to discern which exact vehicle is being charged during any one session. EVSE-side data can be identified where a single charger ID but a range of vehicle IDs are present (e.g., CH001, EV001-EV005). Data collected from the vehicle’s onboard systems usually does not provide information on which exact charger is being used. Vehicle-side data can be identified where a single Vehicle ID but a range of Charger IDs are present (e.g., EV001, CH001-CH005). Data collected from utility submeters provide no information on which specific vehicle is charging or which specific charger is in use. Submeter data can be identified where multiple Vehicle IDs and multiple Charger IDs are present, but only a single Fleet ID is present (e.g., EV001-EV005, CH001-CH005, Fleet01). The **Charge Data Daily/Session Dictionaries** contains definitions for each available parameter collected as part of an individual charging session, aggregated at either a daily or session level. The parameters available will vary between vehicles and chargers. The **Charger Attributes** table contains specific charger characteristics, coded to at least one anonymous Charger ID and linked to either a single or a range of Vehicle IDs. Vehicle ID can be used as a key between charging data and vehicle attribute tables. The **Charger Attributes Data Dictionary** contains definitions for each available parameter collected on the physical and operational characteristics of the charging hardware itself. The **Vehicle Attributes Data Dictionary** contains definitions for each available parameter associated with a vehicle’s physical and functional attributes and fleet context. The **Vehicle Attributes** table contains specific vehicle characteristics, coded to an anonymous Vehicle ID. This Vehicle ID can be used as a key between vehicle data and vehicle attribute tables, and in cases where charging data are supplied, links a vehicle with the charger(s) that supplied it power. The **Charging Data** tables contain the data from each charger’s operations, coded to at least one anonymous Charger ID and linked to either a single or a range of Vehicle IDs. Vehicle ID can be used as a key between charging data and vehicle attribute tables. Data is being uploaded quarterly through 2023 and subject to change until the conclusion of the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗