Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FAST NEUTRON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Cross section measurements via residual nuclear decays: Analysis methods

We develop an approach to calculating the pure cross section of the ground state of artificial radioactive nuclides that subtracts the effect of an excited state on the ground state. We apply a formalism to obtaining pure cross sections by subtracting the effect of excited states in the reactions {sup 122}Te(n,2n){sup 121}Te{sup g} and {sup 128}Te(n,2n){sup 127}Te{sup g}, induced by neutrons of about 14 MeV. The cross sections are measured by an activation relative to the {sup 93}Nb(n,2n){sup 92}Nb{sup m} reaction and are compared with results that take into account the effect of the excited state. Measurements are carried out by {gamma} detection using a coaxial high-purity germanium (HPGe) detector. As samples, spectroscopically pure Te powder is used. The fast neutrons are produced by the {sup 3}H(d,n){sup 4}He reaction. The neutron energies in these measurements are determined using the method of cross-section ratios between the {sup 90}Zr(n,2n){sup 89}Zr{sup m+g} and {sup 93}Nb(n,2n){sup 92}Nb{sup m} reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Technical and economic assessment of different options for minor actinide transmutation: the French case

Studies have been performed to assess the industrial perspectives of partitioning and transmutation of long-lived elements. These studies were carried out in tight connection with GEN-IV systems development. The results include the technical and economic evaluation of fuel cycle scenarios along with different options for optimizing the processes between the minor actinide transmutation in fast neutron reactors, their interim storage and geological disposal of ultimate waste. The results are analysed through several criteria (impacts on waste, on waste repository, on fuel cycle plants, on radiological exposure of workers, on costs and on industrial risks). These scenario evaluations take place in the French context which considers the deployment of the first Sodium-cooled Fast Reactor (SFR) in 2040. 3 management options of minor actinides have been studied: no transmutation, transmutation in SFR and transmutation in an accelerator-driven system (ADS). Concerning economics the study shows that the cost overrun related to the transmutation process could vary between 5 to 9% in SFR and 26 % in the case of ADS.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Irradiation test about oxidation-resistant graphite in WWR-K research reactor - 18533

Graphite materials are used for the in-core components of High Temperature Gas-cooled Reactor (HTGR). It is desirable to enhance oxidation resistance of graphite to keep much safety margin. SiC coating is the candidate method for this purpose. JAEA and four Japanese graphite companies, Toyo Tanso, Ibiden, Tokai Carbon and Nippon Techno-Carbon are studying to develop oxidation-resistant graphite for the in-core components. Neutron irradiation test with two capsules was carried out by WWR-K research reactor of Institute of Nuclear Physics of the Republic of Kazakhstan (INP) through the International Science and Technology Center (ISTC) partner project. The total irradiation cycles of WWR-K operation was 10 cycles and the total duration was 200 days. Irradiation temperature about 1473 K would be attained. The maximum fast neutron fluence (E>0.18 MeV) for the gas-swept capsule irradiated at a central irradiation hole was preliminary calculated as 1.2x10{sup 25} m{sup -2}, and for the sealed capsule at a peripheral irradiation hole as 4.2x10{sup 24} m{sup -2}. Dimension and weight of the irradiated specimens were measured, and outer surface of the specimens were observed by optical microscope. For the irradiated oxidation resistant graphite, out-of-pile oxidation test will be carried out at an experimental laboratory. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Demonstration of Emitted-Neutron Computed Tomography to Count Fuel Pins

In this paper, we report demonstration of emitted-neutron computed tomography using fast fission neutrons to infer the geometry of sources of special nuclear material (SNM) such as fuel pins. In a proof-of-concept measurement at the Idaho National Laboratory’s (INL’s) Zero Power Physics Reactor (ZPPR) facility, an array of unirradiated Pu MOX fuel rodlets in a soup can were imaged, and a bias defect consisting of a single rodlet containing Pu replaced by one containing depleted uranium (DU) was detected. The imaging system employed in the demonstration is based on a newly constructed array of pixelated neutron detectors that are suitable for arrangement in a close-packed imaging array and whose active volume consists of liquid scintillator EJ-309 which allows neutron-gamma discrimination via pulse shape to enable pure fast-neutron imaging. The imaging array was used along with a radial collimator aperture in order to perform high quality fast-neutron imaging where tomographic reconstruction of slices through an object resolve neutron sources similar in dimension to a fuel pellet, or about 1 cm. Measurements were performed at Oak Ridge National Laboratory (ORNL) with neutron sources in addition to those performed at the INL’s ZPPR facility with Pu MOX fuel rodlets. An analogous capability to detect single-pin defects in spent fuel assemblies would be desirable, such as for safeguards verification measurements of spent fuel assemblies just prior to transferring them from the spent fuel cooling pool to long term dry cask storage. This paper describes the design and construction of the present imager, characterization measurements with neutron sources at ORNL, measurements with SNM at INL’s ZPPR facility, and feasibility of building an analogous imager for spent fuel measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of Emitted-Neutron Computed Tomography to Count Fuel Pins

In this paper, we report demonstration of emitted-neutron computed tomography using fast fission neutrons to infer the geometry of sources of special nuclear material (SNM) such as fuel pins. In a proof-of-concept measurement at the Idaho National Laboratory s (INL s) Zero Power Physics Reactor (ZPPR) facility, an array of unirradiated Pu MOX fuel rodlets in a soup can were imaged, and a bias defect consisting of a single rodlet containing Pu replaced by one containing depleted uranium (DU) was detected. The imaging system employed in the demonstration is based on a newly constructed array of pixelated neutron detectors that are suitable for arrangement in a close-packed imaging array and whose active volume consists of liquid scintillator EJ-309 which allows neutron-gamma discrimination via pulse shape to enable pure fast-neutron imaging. The imaging array was used along with a radial collimator aperture in order to perform high quality fast-neutron imaging where tomographic reconstruction of slices through an object resolve neutron sources similar in dimension to a fuel pellet, or about 1 cm. Measurements were performed at Oak Ridge National Laboratory (ORNL) with neutron sources in addition to those performed at the INL s ZPPR facility with Pu MOX fuel rodlets. An analogous capability to detect single-pin defects in spent fuel assemblies would be desirable, such as for safeguards verification measurements of spent fuel assemblies just prior to transferring them from the spent fuel cooling pool to long term dry cask storage. This paper describes the design and construction of the present imager, characterization measurements with neutron sources at ORNL, measurements with SNM at INL s ZPPR facility, and feasibility of building an analogous imager for spent fuel measurements.

Hausladen, Paul↗

Subcritical Copper-Reflected-α-phase Plutonium (SCRαP) Integral Experiment Design

A Subcritical Copper-Reflected α-phase Plutonium (SCRαP) integral benchmark experiment is proposed where multiplication will be approximated using correlated neutron data from a detector system consisting of {sup 3}He tubes inside polyethylene. Measurements will be performed on various subcritical experimental configurations consisting of a weapons-grade plutonium sphere surrounded by different Cu thicknesses. In addition to the proposed base experimental configurations with Cu, additional configurations are planned with the plutonium ball nested in various thicknesses of interleaved polyethylene spherical shells mixed in with the Cu shells. The polyethylene is intended to provide fast neutron moderation and reflection, resulting in additional measurements with differing multiplication, spectra, and nuclear data sensitivity. The proposed experiments will performed at the National Criticality Experiments Research Center (NCERC). NCERC is home to a 4.5-kg α-phase stainless steel clad plutonium sphere that is referred to as the BeRP (Beryllium-Reflected Plutonium) ball due to its historical use in a beryllium-reflected critical experiment. In 2014, similar subcritical measurements were performed with the BeRP ball surrounded by nickel and tungsten. The nickel-reflected measurements were documented as a benchmark evaluation which was accepted by the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Similar to past measurements, the proposed work will help both identify deficiencies and quantify uncertainties in nuclear data and validate computational methods related to neutron multiplication inference for subcritical benchmark evaluations. Monte Carlo simulations were performed for the preliminary design of a subcritical Copper-Reflected - phase Plutonium (SCRP) integral benchmark experiment. Specifically, MCNP{sup R} version 6 was used to determine the k{sub eff} and associated nuclear data sensitivities for different preliminary configurations (reflector thickness, material type). The final experimental design process will include continuous-energy nuclear data sensitivity analysis. This will help assess the potential impact of this integral measurement as it relates to international efforts to continuously improve current libraries (ENDF, JEFF, JENDL etc) that still tend to over/under-estimate the measured results of integral experiments, sometimes significantly. Deficiencies in underlying nuclear data quantities such as Nubar have been shown to have an effect on inferred values from subcritical measurements as well. The proposed experiments and subsequent computational validation will help identify such deficiencies. It will also help validate new nuclear data evaluations, including one for Cu that was recently performed in the resolved region up to 100 MeV for {sup 65}Cu and {sup 63}Cu which is expected to improve Cu-related benchmark simulation performance. The final experimental design phase will also include simulation results that will incorporate the detectors that will be used for the subcritical measurements. For the benchmark portion of the measurements, the main detectors that are being considered are portable neutron multiplicity counters made up of {sup 3}He tubes embedded in polyethylene and lined with cadmium. These detectors employ a data acquisition system that produces list-mode data (correlated information where each event is listed sequentially) that can be analyzed using the Feynman variance-to-mean method. Other detector systems including SNAP (single {sup 3}He tube embedded in polyethylene), and a high-purity germanium (HPGe) detector are being considered for supplementary measurements only and are not intended to be used for the final benchmark measurements. Decoupling the supplementary detectors from the system eliminates any contribution to the total system multiplication, and greatly simplifies the final computational benchmark model. Therefore, an optimization of the portable neutron multiplicity counter placement in the benchmark measurements will be performed to ensure that there is minimal contribution to the total system multiplication. In addition, new temperature measurement techniques and hardware will be explored. (authors)

42 ENGINEERING↗

High-frequency detection of the formation and stabilization of a radiation-induced defect cluster in semiconductor structures

The processes of the formation and stabilization of a radiation-induced defect cluster upon the arrival of a fast neutron to the space-charge region of a semiconductor diode are analyzed. The current pulse formed by secondary electrons is calculated and the spectrum of the signal generated by the diode (detector) under the action of an instantaneous neutron flux of the fission spectrum is determined. The possibility of experimental detection of the picosecond radiation-induced transition processes is discussed.

36 MATERIALS SCIENCE↗

Elemental characterization of LL-MA radioactive waste packages with the associated particle technique

The French Alternative Energies and Atomic Energy Commission (CEA) and National Radioactive Waste Management Agency (ANDRA) are conducting an R and D program to improve the characterization of long-lived and medium activity (LL-MA) radioactive waste packages with analytical methods and with non-destructive nuclear measurements. This paper concerns fast neutron interrogation with the associated particle technique (APT), which brings 3D information about the waste material composition. The characterization of volume elements filled with iron, water, aluminium, and PVC in bituminized and fibre concrete LL-MA waste packages has been investigated with MCNP [1] and MODAR data analysis software [2]. APT provides usable information about major elements presents in the volumes of interest. However, neutron scattering on hydrogen nuclei spreads the tagged neutron beam out of the targeted volume towards surrounding materials, reducing spatial selectivity. Simulation shows that small less than 1 L targets can be characterised up to the half-radius of a 225 L bituminized drum, the matrix of which is very rich in hydrogen. Deeper characterization in concrete is possible but limited by counting statistics due to photon attenuation in this dense matrix and, unless large inspection volumes are considered, by the lack of spatial selectivity of the tagged neutron beam due to neutron scattering. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MICROX-2 cross section library based on ENDF/B-VII

New cross section libraries of a neutron transport code MICROX-2 have been generated for advanced reactor design and fuel cycle analyses. A total of 386 nuclides were processed, including 10 thermal scattering nuclides, which are available in ENDF/B-VII release 0 nuclear data. The NJOY system and MICROR code were used to process nuclear data and convert them into MICROX-2 format. The energy group structure of the new library was optimized for both the thermal and fast neutron spectrum reactors based on Contributon and Point-wise Cross Section Driven (CPXSD) method, resulting in a total of 1173 energy groups. A series of lattice cell level benchmark calculations have been performed against both experimental measurements and Monte Carlo calculations for the effective/infinite multiplication factor and reaction rate ratios. The results of MICROX-2 calculation with the new library were consistent with those of 15 reference cases. The average errors of the infinite multiplication factor and reaction rate ratio were 0.31% {delta}k and 1.9%, respectively. The maximum error of reaction rate ratio was 8% for {sup 238}U-to-{sup 235}U fission of ZEBRA lattice against the reference calculation done by MCNP5. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiation protection measurements around a 12 MeV mobile dedicated IORT accelerator

Purpose: The aim of this study is to investigate radioprotection issues that must be addressed when dedicated accelerators for intraoperative radiotherapy (IORT) are used in operating rooms. Recently, a new version of a mobile IORT accelerator (LIAC Sordina SpA, Italy) with 12 MeV electron beam has been implemented. This energy is necessary in some specific pathology treatments to allow a better coverage of thick lesions. At an electron energy of 10 MeV, leakage and scattered x-ray radiation (stray radiation) coming from the accelerator device and patient must be considered. If the energy is greater than 10 MeV, the x-ray component will increase; however, the most meaningful change should be the addition of neutron background. Therefore, radiation exposure of personnel during the IORT procedure needs to be carefully evaluated. Methods: In this study, stray x-ray radiation was measured and characterized in a series of spherical projections by means of an ion chamber survey meter. To simulate the patient during all measurements, a polymethylmethacrylate (PMMA) slab phantom with volume 30x30x15 cm{sup 3} and density 1.19 g/cm{sup 3} was used. The PMMA phantom was placed along the central axis of the beam in order to absorb the electron beams and the tenth value layer (TVL) and half value layer (HVL) of scattered radiation (at 0 deg., 90 deg., and 180 deg. scattering angles) were also measured at 1 m of distance from the phantom center. Neutron measurements were performed using passive bubble dosimeters and a neutron probe, specially designed to evaluate ambient dose equivalent H{sup *}(10). Results: The x-ray equivalent dose measured at 1 m along the beam axis at 12 MeV was 260 {mu}Sv/Gy. The value measured at 1 m at 90 deg. scattering angle was 25 {mu}Sv/Gy. The HVL and TVL values were 1.1 and 3.5 cm of lead at 0 deg., and 0.4 and 1 cm at 90 deg., respectively. The highest equivalent dose of fast neutrons was found to be at the surface of the phantom on the central beam axis (2.9{+-}0.6 {mu}Sv/Gy), while a lower value was observed below the phantom (1.6{+-}0.3 {mu}Sv/Gy). The neutron dose equivalent at 90 deg. scattering angle and on the floor plane on the beam axis below the beam stopper was negligible. Conclusions: Our data confirm that neutron exposure levels around the new dedicated IORT accelerator are very low. Mobile shielding panels can be used to reduce x-ray levels to below regulatory levels without necessarily providing permanent shielding in the operating room.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cross Section Measurement for the 95Mo(n, {alpha})92Zr Reaction at 4.0, 5.0 and 6.0 MeV

For the {sup 95}Mo(n, {alpha}){sup 92}Zr reaction cross section, there is only one experimental datum in the MeV neutron energy region with large uncertainty. As a result, very large deviations exist in different evaluated nuclear data libraries. This paper report the measurement of cross sections of the {sup 95}Mo(n, {alpha}){sup 92}Zr reaction at En = 4.0, 5.0 and 6.0 MeV. Experiments were performed at the 4.5 MV Van de Graaff of Peking University, China. A twin gridded ionization chamber was used as alpha particle detector and two large area {sup 95}Mo samples placed back to back were adopted. Fast neutrons were produced through the D(d, n){sup 3}He reaction by using a deuterium gas target. A small {sup 238}U fission chamber was adopted for absolute neutron flux determination and a BF{sub 3} long counter was used for neutron flux monitor. Present experimental data are compared with existing evaluations and measurement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact Analysis for Candidate Space Reactor Core Concept Designs for Potential Criticality Study

A hydrodynamics model has been developed to study extreme deformation of the space reactor system impacting on the ground with a high velocity. Two-dimensional geometry models for a monolithic core and a pinned core reactor have been developed with dynamic material models, including the material constitutive models and the equation-of-state models. Calculations have been performed for the reactor impacting onto dry sand at 230 and 150 m/s. A pinned core has a much larger fraction of gas volume in the reactor core and thus collapses faster than a monolithic core. The 150-m/s impact velocity case reveals that the gas coolant channels survive in a monolithic core even though the reactor is massively deformed. In a pinned core, however, most of the gas coolant region collapses with intact or partially collapsed fission product gas cores that are protected by solid UO2 fuel. Sand density varies as it is being compressed. Generally, sand beneath the impacting reactor has a higher density as it is compressed. In addition to consideration of global criticality, it is necessary to investigate local criticality. Because of nonuniform distribution of the gas coolant channels in a deformed monolithic core for the 230-m/s impact velocity case, it may be possible to induce criticality locally in those regions where collapse is more severe. It is not straightforward to make an engineering judgment based solely on impact analysis regarding which core concept is more susceptible to criticality events. The current impact study reveals that a pinned core reactor collapses faster than a monolithic core reactor. A reactor that collapses faster is thought to be more susceptible to producing a criticality. However, a monolithic core reactor with much higher mass and kinetic energy develops much higher compaction in the dry sand beneath the reactor. This means that it is expected to better reflect fast neutrons from the bottom boundary where the sand density for a monolithic core impact becomes much higher than for a pinned core impact. It is strongly recommended that neutronics calculations be performed to determine the susceptibility of criticality for the massively deformed nuclear reactors including appropriate reflecting boundary conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Irradiation of electronic components and circuits at the Portuguese Research Reactor: Lessons learned

The behavior of electronic components and circuits under radiation is a concern shared by the nuclear industry, the space community and the high-energy physics community. Standard commercial components are used as much as possible instead of radiation hard components, since they are easier to obtain and allow a significant reduction of costs. However, these standard components need to be tested in order to determine their radiation tolerance. The Portuguese Research Reactor (RPI) is a 1 MW pool-type reactor, operating since 1961. The irradiation of electronic components and circuits is one area where a 1 MW reactor can be competitive, since the fast neutron fluences required for testing are in most cases well below 10{sup 16} n/cm{sup 2}. A program was started in 1999 to test electronics components and circuits for the LHC facility at CERN, initially using a dedicated in-pool irradiation device and later a beam line with tailored neutron and gamma filters. Neutron filters are essential to reduce the intensity of the thermal neutron flux, which does not produce significant defects in electronic components but produces unwanted radiation from activation of contacts and packages of integrated circuits and also of the printed circuit boards. In irradiations performed within the line-of-sight of the core of a fission reactor there is simultaneous gamma radiation which complicates testing in some cases. Filters can be used to reduce its importance and separate testing with a pure gamma radiation source can contribute to clarify some irradiation results. Practice has shown the need to introduce several improvements to the procedures and facilities over the years. We will review improvements done in the following areas: - Optimization of neutron and gamma filters; - Dosimetry procedures in mixed neutron / gamma fields; - Determination of hardness parameter and 1 MeV-equivalent neutron fluence; - Temperature measurement and control during irradiation; - Follow-up of reactor power operational fluctuations; - Study of gamma radiation effects only. The fission neutron spectrum can be limitative for some of the tests, as most neutrons are in the 1-2 MeV energy range. Significant progress has been made lately in compact neutron generators using D-D and D-T fusion reactions, achieving higher neutron fluxes and longer lifetime than previously available. The advantages of using compact neutron generators for testing of electronic components and circuits will be also discussed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Cross Section Measurement for the 95Mo(n,alpha)92Zr Reaction at 4.0, 5.0 and 6.0 MeV

Measurements of cross sections of the {sup 95}Mo(n, {alpha}){sup 92}Zr reaction at E{sub n} = 4.0, 5.0 and 6.0 MeV were carried out at the 4.5 MV Van de Graaff of Peking University, China. A twin gridded ionization chamber and two large-area {sup 95}Mo samples were adopted. Fast neutrons were produced through the D(d, n){sup 3}He reaction by using a deuterium gas target. A small {sup 238}U fission chamber was employed for absolute neutron flux determination. Present data are compared with existing evaluations and measurement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nuclear radiation detectors based on a matrix of ion-implanted p-i-n diodes on undoped GaAs epilayers

Samples of nuclear detectors which represent matrices of p-i-n diodes were fabricated based on undoped gallium arsenide epitaxial layers by ion implantation technology. The detectors have a size of the active area of 0.4 Multiplication-Sign 0.4 and 0.9 Multiplication-Sign 0.9 cm{sup 2}. Electrical characteristics of fabricated detectors and results of measurements of fast neutrons spectra of {sup 241}Am-Be source by the recoil protons method are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the Radiation Resistance of Endohedral Fullerenes of Rare-Earth Elements and Their Water-Soluble Derivatives

Endohedral metallofullerenes Me@C{sub 2n} (n = 30–50), their hydroxylated derivatives Me@C{sub 2n}(OH){sub 38–40} (Me = Tm, Ho, Eu, Sm, Co), and fullerenol С{sub 60}(OH){sub 38} have been synthesized The radiation resistance of these structures under irradiation in reactor by thermal and fast neutron fluxes in the fluence range of 1018–1019 cm{sup –2} (cadmium ratio of ~10) has been analyzed. Endofullerenols are shown to be more stable in comparison with initial endohedral fullerenes; the molecules containing Eu and Sm (atoms characterized by the largest slow-neutron absorption cross section) turned out to be most stable. The mechanism of the formation of secondary Eu and Sm endofullerenols is discussed taking into account the neutron capture and emission of γ quanta by excited nuclei, which acquire the recoil energy.

36 MATERIALS SCIENCE↗

SU-E-T-239: Design and Evaluation of a Nozzle Shielding System in Passively Scattered Proton Therapy

Purpose: To design, implement and evaluate a shielding system that will reduce out-of-field dose experienced by the patient and associated electronic systems in passively scattered proton therapy treatment. Methods: A multi-stage neutron shielding system was retrofitted to the Gantry 1 treatment nozzle at Loma Linda University Medical Center. The system uses multiple borated polyethylene plates staged after the primary beam modifying devices to attenuate and absorb neutrons produced by such devices. This arrangement locates increasing levels of shielding between the sources of secondary particles in the nozzle and the patient. Additionally, the design of this shielding structure allows it to be easily retrofitted to an existing proton nozzle system without impacting design or treatment beam characteristics. The effectiveness of the shielding was evaluated both through experimental measurements and Geant4 Monte Carlo simulations. Results: Measurements were completed with Landauer Luxel+ dosimeters that use optically stimulated luminescence and CR-39 to detect fast neutrons, thermal neutrons, protons, photons and beta particles. Measurements of a 250 MeV proton beam indicated that the shielding system reduced out-of-field dose to the patient by almost half with dose equivalent values at 50 and 40 cm from the field edge decreasing from 0.965 and 1.262 mSv/Gy to 0.596 and 0.777 mSv/Gy respectively. The installation of the multi-stage shielding system also reduced dose equivalent experienced by electronic systems installed in the treatment room by up to 80%. Geant4 simulations were also used to evaluate the neutron fluence at various positions in the treatment room as well as provide information on microdosimetry spectra within the patient and treatment room. Conclusion: The shielding system described above proved to be an effective an inexpensive method of reducing out-of-field doses to the patient and electronic systems and can be easily retrofitted to existing passive scattering nozzles.

60 APPLIED LIFE SCIENCES↗