Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELONGATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Partial completion of post-irradiation examination of the ORNL samples

A total of six Grade 92 and two 800H samples were identified and secured as the selected ORNL samples, which were irradiated in the High Flux Isotope Reactor (HFIR) of ORNL to 0.46–14.66 dpa at 400 to ~720°C. The Grade 92 is an optimized heat and named as G92-2b. The two 800H samples have one sample as the standard solution-annealed condition and the other sample as a thermos-mechanically processed (TMP) condition with a maximized fraction of low-Σ coincidence site lattice (CSL) boundaries. Tensile tests were completed for the selected ORNL samples using the Irradiated Materials Examination and Testing (IMET) hot cell facility at ORNL. The G92-2b samples were tested at room temperature. The lower temperature irradiation at 400–496.7°C to 0.52–14.66 dpa resulted in minimal changes in tensile properties. However, the higher temperature irradiation at ~683.3–720°C to 0.46–14.63 dpa tended to reduce yield and tensile strength by about –136 to –311 MPa and plastic elongation with the increasing dose. The 800H and 800H-TMP samples were tensile-tested at their irradiation temperature 580°C, which showed >40% increase in yield and tensile strength with nearly 9% reduction in elongation for 800H-TMP compared with 800H.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Tensile Strength and Steam Oxidation Resistance of ODS FeCrAl Sheet and Tubes

ORNL is developing advanced low-Cr oxide dispersion strengthened (ODS) FeCrAlY alloys for accident tolerant fuel cladding, and this report describes the fabrication and characterization of a new ODS FeCrAlYZr (CrAZY) tube. This CrAZY tube was produced by successive steps of pilgering and annealing, in collaboration with a Japanese tube manufacturer. Very fine, elongated sub-grain structure in the as-received tube was consistent with the fine sub-grain structure observed for CrAZY foils fabricated by cold rolling at ORNL and led to very high tensile strength at room temperature. The elongated grain structure along the pilgering direction resulted in lower ductility in the hoop direction compared to the ductility along the tube. Similar anisotropic tensile behavior was also observed for the CrAZY foil with very limited ductility perpendicular to the rolling direction. The foil and tube were heat treated in the 850- 1100ºC range to reduce the residual stress. Recrystallization was observed at temperature as low as 900ºC, with an increasing number of recrystallized grains with increasing temperature. Exposure for 1h at 900ºC resulted in a significant improvement of the foil and tube, with a moderate decrease of strength. Atom probe tomographic analysis revealed the presence of many nano oxide precipitates but also areas with fewer precipitates due to the relatively high extrusion temperature (1100ºC). Finally, the CrAZY tube showed good oxidation resistance in steam at temperature up to 1400ºC.

36 MATERIALS SCIENCE↗

First Annual Progress Report on the Procurement and Post-Irradiation Examination of the Selected Samples of Alloy 800H and Grade 92 and 91 Steels

Ferritic-martensitic steel Grade 92, with Grade 91 as a reference, together with austenitic stainless steel (or Incoloy Alloy) 800H and its grain-boundary-engineered version 800H-TMP (Thermo-Mechanical Processing), is investigated in this project. A total of fifteen Grade 92 samples from two or three heats, four T91 samples from two heats, and six 800H and six 800H-TMP samples from one heat were selected, which were primarily irradiated in the Advanced Test Reactor (ATR) of Idaho National Laboratory (INL), with the rest in the High Flux Isotope Reactor (HFIR) of Oak Ridge National Laboratory (ORNL), BOR-60 of Russia, and Phénix reactor of France. The samples were irradiated in the temperature range of 241 to 720°C and a dose range of 1.28 to ~70 displacements per atom. All the INL and ORNL samples and part of the LANL (Los Alamos National Laboratory) samples have been received at the Irradiated Materials Examination and Testing (IMET) hot cell facility. The selected ORNL samples include six Grade 92 and two 800H samples, which were irradiated in the HFIR to 0.46–14.66 dpa at 400 to ~720°C. The Grade 92 is an optimized heat and named as G92-2b. The two 800H samples have one sample as the standard solution-annealed condition and the other sample as a TMP condition with a maximized fraction of low-Σ coincidence site lattice (CSL) boundaries. Tensile test of the G92-2b samples were conducted at room temperature in the IMET hot cell. The lower temperature irradiation at 400–496.7°C to 0.52–14.66 dpa resulted in minimal changes in tensile properties. However, the higher temperature irradiation at ~683.3–720°C to 0.46–14.63 dpa tended to reduce yield and tensile strength by about –136 to –311 MPa and plastic elongation by –1 to –3% with the increasing dose. The 800H and 800H-TMP samples were tensile-tested at their irradiation temperature 580°C in the IMET hot cell, which showed >40% increase in yield and tensile strength with nearly 9% reduction in elongation for 800H-TMP compared with 800H. Three of the G92-2b samples, i.e., GB04 (7.44 dpa at ~490°C), GB05 (14.66 dpa at 496.7°C), and GB12 (14.63 dpa at ~720°C), were examined at the LAMDA for Vickers hardness measurements and microstructural characterization by SEM and TEM. Vickers hardness was successfully measured on GB12, which was reduced by is – (112.4 ± 12.3) HV1 from the control sample. However, the Vickers hardness measurements were failed on GB04 and GB05 because the samples were polished too thin to prevent the interference from the substrate (epoxy). The other half of the GB04 and GB05 will be polished for the hardness measurements, as well as nanoindentation studies. Fractography by SEM indicated increased numbers of ductile dimples (or voids) with the increasing irradiation dose, while significantly increased numbers and sizes of dimples with the increasing irradiation temperature. TEM characterization exhibited the presence of Cr 23 C 6 , VN, and Laves precipitates at boundaries and matrix, which showed pronounced precipitate-dislocation interactions (pinning effect). Dense dislocations but limited dislocation loops were observed in the samples, which noticeably reduced in GB12. Additionally, some tiny partially amorphized spherical domains were observed in GB12, which had a normal body-centered cubic lattice parameter of 9Cr steels at the surround regions but ~11% smaller than the lattice parameter of the matrix away from the amorphized spherical domains. Further characterization will be pursued to clarify the new findings.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mechanical Testing of FeCrAl Tubing

The axial tensile properties of C26M tube were successful measured at Los Alamos National Laboratory. Test were conducted at a constant strain rate of 10 -3 s -1 and three different temperatures (22, 300, and 600°C). As typically expected, an increase in the testing temperature lead to a decrease in both the yield stress (YS), from 710 to 273 MPa, and ultimate tensile strength (UTS), from 730 to 290 MPa. The ultimate tensile strength was observed almost immediately post-yielding for all test conditions, and thus the uniform elongation was limited to 1.2-1.6%. The total elongation of the 600°C specimens was notably higher (~47%) than both the 22 and 300°C specimens, which exhibited a similar response (~10%).

36 MATERIALS SCIENCE↗

Microstructure and Mechanical of U-6Nb and U-8Nb in Gamma Quenched and Long-Term Aged Conditions

This report documents the mechanical response and associated microstructure in a number of recent Los Alamos studies of U-6Nb and U-8Nb alloys in the as-quenched and artificially aged conditions, to serve as a primary data reference. Quasi-static tensile and hardness data (in the form of averages) are reported along with microstructures revealed by light optical and scanning electron microscopy. Total elongation data were converted to a common standard for ease of comparison of data from different tensile specimen geometries. A variety of alternate measures of total tensile elongation confirmed the trends one would find from considering only extensometer data. The various U-Nb material pedigrees and experimental conditions are as follows. Y-12-produced U-6Nb as quenched – effect of machining damage as quenched – effect of extensometer length 200oC ages for up to 22 days Rocky Flats-produced U-6Nb 40, 65, and 90oC ages for up to 10 years 300, 350, and 400°C ages for up to 1.2 years Los Alamos-produced nonbanded U-5.6Nb and U-7.7Nb variety of ages over 100-600°C for up to 5 years We characterized the chemical banding by microprobe and Knoop microhardness surveyed over long regions in a dozen Y-12 U-6Nb specimens. As expected, the light-vs.-dark imaging response (both by light optical and scanning electron microscopy) correlated well with the local wt.% Nb. However, the hardness did not correlate well with either imaging or microprobe, and hence cannot be used to predict the local wt.% Nb.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of Electron Irradiation on Candidate Materials for Target Window in Accelerator-Driven Mo-99 Production

Room-temperature (RT) axial tensile tests were conducted in 2018 and 2021 with flat, sub-sized, dog-boned samples of non-irradiated and irradiated Inconel 718 and irradiated beryllium (Be). The sample gauge length was 7.62 mm. Tensile properties of interest are the engineering yield stress (YS), ultimate tensile stress (UTS), uniform elongation (UE) and total elongation (TE). The electron dose of the 2021 samples was ≈2 times the dose of samples tested in 2018. Relative dose rates of 0, 1 (2018), and 2 (2021) are assigned to these samples. The 2021 electron-irradiated Be samples were brittle with a low failure stress of 338±64 MPa based on two samples. The failures occurred in the gauge section. The 2018 results for electron-irradiated Be indicated a slight decrease in ductility and strength for the one electron-irradiated sample that failed in the gauge section.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Irradiated stainless steel 347 and irradiated, welded, and hydrogen charged Zircaloy-4 property data for the target solution vessel and support lines of SHINE

In support of the reactor-vessel development effort of SHINE medical technologies, irradiation of its structural materials and post-irradiation testing have been performed in the High Flux Isotope Reactor at Oak Ridge National Laboratory. This irradiation was performed on welded and unwelded AISI 347 steel and Zircaloy-4 samples at low temperature (~60°C) in contact with the reactor coolant. Hardness, Charpy, and tensile data have been taken from all cases of unirradiated specimens, while post-irradiation tensile and hardness data have been taken from AISI 347 base metal and Zircaloy-4 base metal and weld specimens so far. Additionally, 3-point bend data have been taken from explosion-welded specimens. The expected changes to hardness, yield strength, ultimate tensile strength, uniform elongation, and total elongation as a result of the low temperature and low dose neutron irradiation are reported here.

36 MATERIALS SCIENCE↗

High-Temperature Tensile and Creep Test Results on Thin Wall Tube Specimens of ODS Alloys 14YWT and OFRAC

High-temperature tensile and strain rate jump (SRJ) creep tests were conducted on axial specimens fabricated from thin wall tubes of the oxide dispersion strengthened (ODS) alloys 14YWT and OFRAC. The dimensions of the 14YWT thin wall tube was 10.7 mm OD, 0.5 mm WT and 0.92 m and of the OFRAC thin wall tube was 8.5 mm OD + 0.5 mm WT and 1.78 m in length. The axial specimens fabricated from the thin wall tubes were based on a dual-gauge design with gauge dimensions of 4 mm long and 2 mm wide. The tensile tests were conducted in air at 800ºC, 900ºC and 1,000ºC and the SRJ creep tests were conducted in air at 800ºC. Two axial specimens were used in each tensile and SRJ creep tests. The results of the tensile tests showed much lower yield stress (YS) compared to ultimate tensile strength (UTS) indicative of large work hardening properties. The results showed the UTS of OFRAC was higher than that of 14YWT by ~35 MPa at 800ºC. At 900ºC, the UTS of OFRAC and 14YWT was similar at 900ºC and at 1000ºC, the UTS of 14YWT was higher than that of OFRAC by ~10 MPa. The ductility properties of OFRAC were greater than that of 14YWT with higher values of uniform elongation (UE) and total elongation (TE) at all tensile test temperatures. The creep properties of 14YWT and OFRAC were evaluated by the strain rate jump test method at 800ºC. The stress exponent (n) for creep was obtained from the SRJ test data by plotting the values of the log strain rate against the log stress, which is measured from the stress-strain curve generated during the SRJ test. The results showed the highest stress exponents of n = 19.8 and n = 35.0 were measured from the two SRJ tests on 14YWT. The stress exponent measured from one successful SRJ test on OFRAC was n = 13.3, which was lower than that of 14YWT. Nevertheless, these high values of stress exponent are consistent with ODS ferritic alloys such as 14YWT and OFRAC since they indicate dislocation-particle interactions are the dominant creep mechanism for specific ranges of temperature and stress. The results obtained from the tensile and SRJ creep tests conducted on axial specimens in this study indicate that 14YWT and OFRAC retain high strengths at temperatures up to 1,000ºC and good creep performance at 800ºC.

36 MATERIALS SCIENCE↗

Second group of irradiation capsules: property data of irradiated welded stainless steel 347 and irradiated, welded, and hydrogen charged Zircaloy-4 for SHINE

Zircaloy-4 and AISI 347 stainless steel were irradiated to low doses (10 20 and 10 21 n/cm 2 ) at low temperature (~60°C) in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). These materials were under consideration for some of the structural components of the medical isotope production facility developed by SHINE Technologies. Zircaloy-4 base metal, as welded, welded and post-weld heat treated (PWHT), and hydrogen charged samples were irradiated. AISI 347 base metal from Sandmeyer Steel, Penn Stainless, and Rolled Alloys suppliers were irradiated. AISI 347 gas tungsten arc welding (GTAW) and flux-cored arc welding (FCAW) samples of Penn Stainless and Rolled Alloys were also irradiated. The irradiated materials were tested with microhardness and tensile tests at room temperature in air. The AISI 347 materials had more elongation after irradiation than the Zircaloy-4 materials. In fact, the Zircaloy-4 welded without PWHT and with H charging had the lowest elongation of any of the materials. This report is the final in a series of reports on this project.

36 MATERIALS SCIENCE↗

Small Punch Testing of Molybdenum-99 Targets

Northstar Medical Radioisotopes is developing an accelerator-based method to produce 99 Mo, which is a parent isotope of the commonly used 99m Tc medical isotope. The Mo targets being designed for the accelerator will be produced from enriched 100 Mo, also known as aMo . Pressed and sintered powder feedstock is used to fabricate aMo targets, producing 29 mm disk-shaped targets. The targets are subjected to 1–6 days in line of an electron beam with subsequent dissolution of the disk to retain the 99 Mo, which decays to 99m Tc at radio-pharmacies. The press and sinter method is advantageous because the inherent porosity produced by this method enables increased surface area and therefore increased flow of dissolution media, decreasing the dissolution time and reducing the need for a highly acidic media. Although porosity aids in dissolution, it reduces the mechanical strength and ductility. Targets require good mechanical integrity when subjected to the conditions in the accelerator. Therefore, Northstar is seeking methods to rapidly test disk samples after fabrication to assure mechanical performance metrics are achieved. This report details the design and testing of a small punch test (SPT) that accommodates the 29 mm disk. Initial data were used to relate the SPT data to tensile properties, such as the yield strength (YS), ultimate tensile strength (UTS), and total elongation to failure. Although the SPT has been established as a somewhat reliable method for testing metallic materials, few studies have applied the SPT to refractory materials such as Mo. Based on tensile testing performed at Oak Ridge National Laboratory on different Mo samples, correlation between the Mo tensile and SPT properties could be performed, establishing a standard calibration that could be applied to other Mo samples. To test the efficacy of the SPT with Mo, multiple different disk batches were fabricated under different conditions (e.g., pressure, lubricant) with commercially available pure Mo powder. Generally, only a UTS could be well defined because the press and sinter disks failed under brittle fracture, making it difficult to determine the YS and elongation. Compared with disks fabricated with aMo powder, the aMo samples underperformed their pure nat Mo counterparts. This report summarizes the current status of the SPT, but further evaluation is needed before it can be applied as a reliable quality assurance tool.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High Temperature Tensile Testing of Molybdenum Before and After Exposure in Flowing He at 600°C to 1000°C

ORNL supported NorthStar Medical Radioisotope’s accelerator-based concept to produce the medical isotope molybdenum-99 (Mo-99). The Mo targets are expected to experience in the accelerator temperature ranging from 200°C to 1000°C, and previous studies have demonstrated the embrittlement of Mo targets at room temperature when exposed to impure He at 800 to 1000°C. The goal of this project was to evaluate potential embrittlement at temperature ranging from 600°C to 1000°C for three Mo materials exposed at the same temperatures for 100h in high purity He (O 2 < 5ppm (µl/l)) with a flow rate of ~1m/s. Enriched Mo-100 (aMo) and conventional pressed and sintered Mo (UHP) disks were provided by NorthStar while low carbon arc cast rolled Mo, fabricated at ORNL, was used for comparison. The as fabricated rolled Mo exhibited superior tensile strength due to the alloy very fine grain size with limited ductility except at 1000°C with the elongation at rupture reaching 30%. The UHP Mo disks showed the lowest strength but highest ductility at 20-1000°C with significant strain hardening during tensile testing. The ductility of the aMo material was quite low at all temperatures due to a high density of voids at grain boundaries. Significant embrittlement of the aMo material was observed after exposure at 600°C to 1000°C, most likely because of oxygen diffusion and segregation at grain boundaries. No embrittlement was observed for the UHP Mo material, with excellent elongation at rupture for some of the specimens oxidized in He and tested at 600-1000°C. Significant variation in ductility from one UHP Mo specimen to another was, however, measured, both in the as fabricated and He-oxidized conditions. The rolled Mo was not affected by oxidation in He at 800°C, but a decrease in strength and increase in ductility was observed at 1000°C, likely due to the material recrystallization.

36 MATERIALS SCIENCE↗

Process Variability Effects on Tensile Response in Injection Molded, Fluorinated Thermoplastics

The mechanical properties of fluorinated thermoplastics (i.e., tensile strength and elongation) can vary with changes in injection molding processing parameters. Four fluoropolymers are examined: poly(vinylidene fluoride) (PVDF) and random poly(vinylidene fluoride-co-chlorotrifluoroethylene) (PVDF-CTFE) with three CTFE concentrations. Dog bones were manufactured with various cylinder dwell times and mold cooling times to assess the manufacturing sensitivity to the tensile response. Dwell and cooling times increasingly impact mechanical performance as CTFE concentration increases. Specimens exhibit higher tensile strength as a function of injection order. The first injected specimen exhibits the lowest tensile strength and highest elongation in all copolymers. This trend becomes more pronounced among fluoropolymers with higher CTFE concentration and lower weight-averaged molecular weight. Parallel plate rheology was used to obtain the zero-shear viscosity as a function of material type, process, and injection order. We found that in the copolymers, the first injected sample exhibited a lower zero-shear viscosity than the next, which indicates a lower molecular weight in the first injected specimen. This phenomenon was not present for the PVDF homopolymer. Copolymer mechanical uncertainties are hypothesized to result from the shorter molecular weight chains extruding out of the specimens’ sides as a flash due to higher mobility with CTFE segments.

36 MATERIALS SCIENCE↗

Development of emerging model microorganisms: Megasphaera elsdenii for biomass and organic acid upgrading to fuels and chemicals

The metabolic diversity of microorganisms in nature represents a largely untapped source of valuable compounds that are difficult or impossible to produce in the limited number of available model systems. Efforts to produce longer-chain alcohols, such as hexanol, in organisms like Escherichia coli have met with limited success; production of C6 and larger products remains low, highlighting the challenges of extending chain elongation pathways beyond a single cycle. Megasphaera elsdenii naturally condenses acetyl-CoA to efficiently generate C4–C8 organic acids, making it a promising candidate for producing fuels and chemicals from lactate and plant-derived carbohydrates. This high native flux through the chain elongation pathway offers the potential for higher yields and titers of medium-chain products, such as hexanol, compared to conventional hosts. Recent advances—most notably the development of a transformation method for M. elsdenii—have further opened the organism to detailed physiological studies and bioengineering. While full development of M. elsdenii as a hexanol-producing platform was not achieved, significant progress was made in understanding its metabolism and building foundational genetic tools for future engineering.

60 APPLIED LIFE SCIENCES↗

Tailored Silicone Network Architecture for Ultimate Mechanical Reinforcement

Hydrosilylation cured silicone elastomers are subject to reaction inefficiency, leading to incomplete and non-uniform crosslink networks, restricting the potential of mechanical reinforcement. This work investigates pre-synthesized, functional PDMS architectures as additives to improve ultimate mechanical performance relative to conventional single-step curing. Three custom, functional structures were prepared: a partially crosslinked PDMS scaffold (Structure A), a bottle-brush PDMS (Structure B), and a star-shaped PDMS derived from an MQ resin (Structure C). Rheological characterization was used to identify the ultimate design space and proper stoichiometric ratio for Structure A, and confirm successful formation of all structures for suitable incorporation into a base silicone formulation at 30wt%. Mechanical tests indicated that all three structures increased in ultimate tensile strength relative to their single-step counterparts, with Structure A providing additional improvements to toughness (432 vs. 258 kJ/m3) and ultimate elongation (158 vs. 115%). Furthermore, Structure B remained very soft in the unfilled state, while Structure C provided hardness (23 vs. 18 Shore A) and stiffness (780 vs. 420 kPa Young’s modulus) increases. In silica filled systems, Structure A retained increased strength but reduced elongation, while Structure B indicated strong reinforcement in terms of strength, toughness, and stiffness. Thermal analysis on the cure profiles of these materials suggested that pre-formation of network architectures enable a more complete reaction than a single-step process (15.9 vs. 15.1 J/g). Ultimately, these results indicate that tailoring PDMS architecture before the final cure can improve ultimate mechanical properties via improved network development in silicone elastomers. Furthermore, this work offers a promising strategy for designing higher-performance, more tunable silicone formulations.

36 MATERIALS SCIENCE↗

Tempering and Austempering of Double Soaked Medium Manganese Steels

The addition of a tempering or austempering step to the double soaking of a 0.14C–7.17Mn (wt pct) steel was investigated in the present contribution. The double soaking heat treatment is a two-step intercritical annealing heat treatment, which generates microstructures of athermal martensite, retained austenite and ferrite when applied to medium manganese steels. Microstructures following double soaking and (aus)tempering contained a combination of retained austenite, athermal or tempered martensite, and blocky or bainitic ferrite. X-ray diffraction, dilatometry and transmission Kikuchi diffraction were utilized to investigate microstructural changes which occurred during tempering or austempering. The resulting mechanical properties were measured using uniaxial tensile testing. The double soaking plus tempering heat treatment was shown to generate an ultimate tensile strength of 1,340 MPa in combination with 28 pct total elongation while the double soaking plus austempering heat treatment resulted in an ultimate tensile strength of 1,675 MPa and total elongation of 22 pct. Overall, both novel heat treatments produced a combination of strength and ductility desired for the third generation of advanced high strength steels.

36 MATERIALS SCIENCE↗

Analysis of Factors Limiting Bacterial Growth in PDMS Mother Machine Devices

The microfluidic mother machine platform has attracted much interest for its potential in studies of bacterial physiology, cellular organization, and cell mechanics. Despite numerous experiments and development of dedicated analysis software, differences in bacterial growth and morphology in narrow mother machine channels compared to typical liquid media conditions have not been systematically characterized. Here we determine changes in E. coli growth rates and cell dimensions in different sized dead-end microfluidic channels using high resolution optical microscopy. We find that E. coli adapt to the confined channel environment by becoming narrower and longer compared to the same strain grown in liquid culture. Cell dimensions decrease as the channel length increases and width decreases. These changes are accompanied by increases in doubling times in agreement with the universal growth law. In channels 100 μm and longer, cell doublings can completely stop as a result of frictional forces that oppose cell elongation. Before complete cessation of elongation, mechanical stresses lead to substantial deformation of cells and changes in their morphology. Lastly, our work shows that mechanical forces rather than nutrient limitation are the main growth limiting factor for bacterial growth in long and narrow channels.

59 BASIC BIOLOGICAL SCIENCES↗

Proteomics Coupled with Metabolite and Cell Wall Profiling Reveal Metabolic Processes of a Developing Rice Stem Internode

Internodes of grass stems function in mechanical support, transport, and, in some species, are a major sink organ for carbon in the form of cell wall polymers. This study reports cell wall composition, proteomic and metabolite analyses of the rice elongating internode. Along eight segments of the second rice internode (internode II) at booting stage, cellulose, lignin, and xylose increase as a percentage of cell wall material from the younger to the older internode segments, indicating active cell wall synthesis. Liquid-chromatography tandem mass spectrometry (LC-MS/MS) of trypsin-digested peptides of size-fractionated proteins extracted from this internode at booting reveals 2547proteins with at least two unique peptides. The dataset includes many glycosyltransferases, acyltransferases, glycosyl hydrolases, cell wall-localized proteins, and protein kinases that have or may have functions in cell wall biosynthesis or remodeling. Phospho-enrichment of the internode II peptides identified 21 unique phosphopeptides belonging to 20 phosphoproteins including an LRR-III family receptor like kinase. GO over-representation and KEGG pathway analyses highlight the abundances of internode proteins involved in biosynthetic processes, especially the synthesis of secondary metabolites such as phenylpropanoids and flavonoids. LC-MS of hot methanol-extracted secondary metabolites from internode II at four stages (elongation, early mature, mature and post mature) indicates that secondary metabolites in stems are distinct from those of roots and leaves, and differ during stem maturation. This work fills a void of knowledge of proteomics and metabolomics data for grass stems, specifically for rice, and provides baseline knowledge for more detailed studies of cell wall synthesis and other biological processes during internode development, toward improving grass agronomic properties.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of Intercritical Annealing Temperature on Mechanical Properties of Fe-7.9Mn-0.14Si-0.05Al-0.07C Steel

A medium Mn steel has been designed to achieve an excellent combination of strength and ductility based on the TRIP (Transformation Induced Plasticity) concept for automotive applications. Following six passes of hot rolling at 850 °C, the Fe-7.9Mn-0.14Si-0.05Al-0.07C (wt.%) steel was warm-rolled at 630 °C for seven passes and subsequently air cooled to room temperature. The sample was subsequently intercritically annealed at various temperatures for 30 min to promote the reverse transformation of martensite into austenite. The obtained results show that the highest volume fraction of austenite is 39% for the sample annealed at 600 °C. This specimen exhibits a yield stress of 910 MPa and a high ultimate tensile stress of 1600 MPa, with an elongation-to-failure of 0.29 at a strain rate of 1 × 10⁻³/s. The enhanced work-hardening ability of the investigated steel is closely related to martensitic transformation and the interaction of dislocations. Especially, the alternate arrangement of acicular ferrite (soft phase) and ultrafine austenite lamellae (50–200 nm, strong and ductile phase) is the key factor contributing to the excellent combination of strength and ductility. On the other hand, the as-warm-rolled sample also exhibits the excellent combination of strength and ductility, with elongation-to-failure much higher than those annealed at temperatures above 630 °C.

36 MATERIALS SCIENCE↗