Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Effects of vacuum fluctuation suppression on atomic decay rates

Highlights: > Excited atoms are shot through a cavity containing an electromagnetic field. > Cavity is in the lowest mode in a non-classical state. > Such a state can suppress the decay rate of the atoms in certain situations. > We show that this effect can be correlated with periods of negative energy density. - Abstract: The use of atomic decay rates as a probe of sub-vacuum phenomena will be studied. Because electromagnetic vacuum fluctuations are essential for radiative decay of excited atomic states, decay rates can serve as a measure of the suppression of vacuum fluctuations in non-classical states, such as squeezed vacua. In such states, the renormalized expectation value of the square of the electric field or the energy density can be periodically negative, representing suppression of vacuum fluctuations. We explore the extent to which atomic decays can be used to measure the mean squared electric field or energy density. We consider a scheme in which atoms in an excited state transit a closed cavity whose lowest mode contains photons in a non-classical state. A crucial feature of our analysis is that we do not employ the rotating wave approximation. The change in the decay probability of the atom in the cavity due to the non-classical state can, under certain circumstances, serve as a measure of the mean squared electric field or energy density in the cavity. We make some estimates of the magnitude of this effect, which indicate that an experimental test might be possible, although very challenging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Forecast constraints on inflation from combined CMB and gravitational wave direct detection experiments

We study how direct detection of the inflationary gravitational wave background constrains inflationary parameters and complements CMB polarization measurements. The error ellipsoids calculated using the Fisher information matrix approach with Planck and the direct detection experiment, Big Bang Observer (BBO), show different directions of parameter degeneracy, and the degeneracy is broken when they are combined. For a slow-roll parametrization, we show that BBO could significantly improve the constraints on the tensor-to-scalar ratio compared with Planck alone. We also look at a quadratic and a natural inflation model. In both cases, if the temperature of reheating is also treated as a free parameter, then the addition of BBO can significantly improve the error bars. In the case of natural inflation, we find that the addition of BBO could even partially improve the error bars of a cosmic variance-limited CMB experiment.

79 ASTRONOMY AND ASTROPHYSICS↗

Four direct measurements of the fine-structure constant 13 billion years ago

Observations of the redshift z = 7.085 quasar J1120+0641 are used to search for variations of the fine structure constant, a, over the redshift range 5:5 to 7:1. Observations at z = 7:1 probe the physics of the universe at only 0.8 billion years old. These are the most distant direct measurements of a to date and the first measurements using a near-IR spectrograph. A new AI analysis method is employed. Four measurements from the x - shooter spectrograph on the Very Large Telescope (VLT) constrain changes in a relative to the terrestrial value (α 0 ). The weighted mean electromagnetic force in this location in the universe deviates from the terrestrial value by Δα/α = (α z - α 0 )/α 0 = (-2:18 ± 7:27) × 10 -5 , consistent with no temporal change. Combining these measurements with existing data, we find a spatial variation is preferred over a no-variation model at the 3:9σ level.

79 ASTRONOMY AND ASTROPHYSICS↗

A diagnostic system for electrical faults in a high current discharge plasma setup

A diagnostic system to detect electrical faults inside a coaxial high current discharge device is presented here. This technique utilizes two biconical antennas picking up electromagnetic radiation from the discharge device, a voltage divider sensing input voltage, and a Rogowski coil measuring the main discharge current. A computer program then analyses frequency components in these signals and provides information as to whether the discharge event was normal or any breakdown fault occurred inside the coaxial device. The diagnostic system is developed for a 450 kV and 50 kA capillary discharge plasma setup. For the setup various possible faults are analyzed by electrical simulation, followed by experimental results. In the case of normal discharge through the capillary load the dominant frequency is {approx}4 MHz. Under faulty conditions, the peak in magnitude versus frequency plot of the antenna signal changes according to the fault position which involves different paths causing variation in the equivalent circuit elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of a LYSO crystal array from threshold to 100 MeV

We report measurements of ten custom-made high-homogeneity LYSO crystals. The investigation is motivated by the need for a compact, high-resolution, and fast electromagnetic calorimeter for a new rare pion decay experiment. Each 2.5 x 2.5 x 18 cm 3 crystal was first characterized for general light yield properties and then its longitudinal response uniformity and energy resolution were measured using low-energy gamma sources. The ten crystals were assembled as an array and subjected to a 30–100 MeV positron beam with excellent momentum definition. The energy and timing resolutions were measured as a function of energy, and the spatial resolution was determined at 70 MeV. An additional measurement using monoenergetic 17.6 MeV gammas produced through a p-Li resonance was later made after the photosensors used in positron testing were improved. Here, as an example of the results, the energy resolution at 70 MeV of (1.52 ± 0.03) % is more than two times better than reported results using previous generation LYSO crystals.

Electromagnetic calorimeter↗

Enthalpy of Mixing in Al–Tb Liquid

The liquid-phase enthalpy of mixing for Al$-$Tb alloys is measured for 3, 5, 8, 10, and 20 at% Tb at selected temperatures in the range from 1364 to 1439 K. Methods include isothermal solution calorimetry and isoperibolic electromagnetic levitation drop calorimetry. Mixing enthalpy is determined relative to the unmixed pure (Al and Tb) components. The required formation enthalpy for the Al3Tb phase is computed from first-principles calculations. Finally, based on our measurements, three different semi-empirical solution models are offered for the excess free energy of the liquid, including regular, subregular, and associate model formulations. These models are also compared with the Miedema model prediction of mixing enthalpy.

36 MATERIALS SCIENCE↗

HTS Dipole Prototype Magnet for NSLS X13A Endstation

This article reports the design, three-dimensional magnetostatic simulation results, coil fabrication, assembly, and low-temperature test results of a C-frame, iron-dominated high-temperature superconductor dipole magnet for ultra high vacuum magnetic-sensitive spectroscopy techniques at the National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory. The magnet is required to provide fields up to ~1 T along two spatial directions. With an added capability to rotate about its vertical axis of symmetry, the magnet system is capable of delivering field along all three principal axes. The combination of this magnet and fast-switched, elliptically polarized soft X-rays produced by the NSLS elliptically polarized wiggler forms the basis for an excellent tool for polarization-sensitive studies of magnetic materials. The prototype magnet consists of a set of pancake coils fabricated from BSCCO tape reinforced with stainless steel. Those pancake coils are clamped in a low-carbon AISI 1006 grade steel pole and yoke assembly. For testing purposes, a cold He gas environment provided cooling the superconducting magnet to subtransition temperatures; for operation in an ultra high vacuum endstation environment, cooling can be provided by an external cryocooler. The low-temperature tests establish the safe-operating parameters needed to achieve the target magnetic field values. The measured magnetic field values are in close agreement with the magnetic simulation results, thereby confirming that the magnet design fulfills the performance requirements. Here, the final section of this article lists some suggestions to improve the magnet performance.

36 MATERIALS SCIENCE↗

Dynamic Magnetization Characteristics of Proportional Electromagnets

A method is proposed for analysis of the dynamic magnetization characteristics of proportional electromagnets. By that means, the electrical parameters may be determined, with a view to controlling the production process. The method includes three basic steps. First, the information to be analyzed is winnowed by a projection method. The second step is to classify the measured characteristics in groups. In the third step, regression models are used to determine the electrical parameters of the components in a proportional electromagnet.

42 ENGINEERING↗

Measurement of electrons from heavy-flavour decays in p-Pb collisions at √(S{sub NN}) = 5.02 TeV with ALICE

Electrons from the decay of hadrons containing charm or beauty quarks have been measured in p-Pb collisions at √(S{sub NN}) = 5.02 TeV with ALICE. Electrons from heavy-flavour hadron decays were identified using the Time Projection Chamber and the Electromagnetic Calorimeter of ALICE. The nuclear modification factor R{sub pPb} was calculated using a pp reference obtained from a perturbative QCD-based √(s)-extrapolation of the cross section measured at 7 TeV and from a FONLL prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accelerated ions from pulsed-power-driven fast plasma flow in perpendicular magnetic field

To understand the interaction between fast plasma flow and perpendicular magnetic field, we have investigated the behavior of a one-dimensional fast plasma flow in a perpendicular magnetic field by a laboratory-scale experiment using a pulsed-power discharge. The velocity of the plasma flow generated by a tapered cone plasma focus device is about 30 km/s, and the magnetic Reynolds number is estimated to be 8.8. After flow through the perpendicular magnetic field, the accelerated ions are measured by an ion collector. To clarify the behavior of the accelerated ions and the electromagnetic fields, numerical simulations based on an electromagnetic hybrid particle-in-cell method have been carried out. The results show that the behavior of the accelerated ions corresponds qualitatively to the experimental results. Faster ions in the plasma flow are accelerated by the induced electromagnetic fields modulated with the plasma flow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PARTICLE ACCELERATION IN THE EXPANDING BLAST WAVE OF {eta} CARINA'S GREAT ERUPTION OF 1843

Non-thermal hard X-ray and high-energy (HE; 1 MeV {<=} E {<=} 100 GeV) {gamma}-ray emission in the direction of {eta} Carina has been recently detected using the INTEGRAL, AGILE, and Fermi satellites. So far this emission has been interpreted in the framework of particle acceleration in the colliding wind region between the two massive stars. However, the existence of a very fast moving blast wave which originates in the historical 1843 'Great Eruption' provides an alternative particle acceleration site in this system. Here, we explore an alternate scenario and find that inverse Compton emission from electrons accelerated in the blast wave can naturally explain both the flux and spectral shape of the measured hard X-ray and HE {gamma}-ray emission. This scenario is further supported by the lack of significant variability in the INTEGRAL and Fermi measured fluxes.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of an electrically conductive proppant for fracture diagnostics

Fracture diagnosis with electromagnetic (EM) and electrical tools requires proppants with high electrical conductivity and mechanical strength. Lab measurements of the electrical and hydraulic conductivity of proppants are critical for selecting the best candidates. Such measurements greatly benefit simulations, field tests, and the ultimate application of such proppants in the field. To that end, a new lab protocol is developed for measuring the electrical and hydraulic conductivity of proppants. The lab setup, which mainly includes a resistivity core holder and a Hassler sleeve core holder, allows for simulation of realistic pressure and temperature conditions when making measurements. Petroleum coke (PC) is proposed as a candidate proppant because of its widespread availability and low cost. Lab measurements show that the effective electrical conductivity of pure PC in a model fracture is approximately 5000 S/m, under a closure stress greater than [Formula: see text] (4000 psi). When PC is mixed with sand, the effective electrical conductivity of the mixture decreases with an increasing weight percentage of sand. Although sand degrades the contact between PC particles, the electrical conductivity stays reasonably high (approximately 1700 S/m) when 50% sand is added. Hydraulic conductivity measurements show that when a fracture is propped with pure PC, the measured fracture conductivity is greater than [Formula: see text] ([Formula: see text]) (dimensionless fracture conductivity greater than 100 for a shale with [Formula: see text] or 100 nD permeability) under a confining pressure of [Formula: see text] (6000 psi). This means that a fracture propped with PC is infinitely conductive in a typical shale formation. When sand is added, the fracture’s hydraulic conductivity becomes even higher, which clearly shows PC’s ability of sustaining high stresses. The proposed protocol provides a robust and effective method that can be generalized for lab testing for other candidate proppants. The data presented clearly show that PC has the potential for field-scale applications in EM hydraulic fracture diagnostics.

Geochemistry & Geophysics↗

Discontinuity induced angular distribution of photon plasmon coupling

Metal-dielectric transitions are important structures that can display a host of optical characteristics including excitation of plasmons. Metal-dielectric discontinuities can furthermore support plasmon excitation without a severe condition on the incident angle of the exciting photons. Using a semi-infinite thin gold film, we study surface plasmon (SP) excitation and the associated electromagnetic near-field distribution by recording the resulting plasmon interference patterns. In particular, we measure interference periods involving SPs at the scanable metal/air interface and the buried metal/glass one. Supported by optical near-field simulations and experiments, we demonstrate that the metal/glass surface plasmon is observable over a wide range of incident angles encompassing values above and below the critical incident angle. As a result, it is shown that scanning near-field microscopy can provide quantitative evaluation of the real part of the buried surface plasmon wavevector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring Plasma Formation Field Strength and Current Loss in Pulsed Power Diodes

This LDRD investigated plasma formation, field strength, and current loss in pulsed power diodes. In particular the Self-Magnetic Pinch (SMP) e-beam diode was studied on the RITS-6 accelerator. Magnetic fields of a few Tesla and electric fields of several MV/cm were measured using visible spectroscopy techniques. The magnetic field measurements were then used to determine the current distribution in the diode. This distribution showed that significant beam current extends radially beyond the few millimeter x-ray focal spot diameter. Additionally, shielding of the magnetic field due to dense electrode surface plasmas was observed, quantified, and found to be consistent with the calculated Spitzer resistivity. In addition to the work on RITS, measurements were also made on the Z-machine looking to quantify plasmas within the power flow regions. Measurements were taken in the post-hole convolute and final feed gap regions on Z. Dopants were applied to power flow surfaces and measured spectroscopically. These measurements gave species and density/temperature estimates. Preliminary B-field measurements in the load region were attempted as well. Finally, simulation work using the EMPHASIS, electromagnetic particle in cell code, was conducted using the Z MITL conditions. The purpose of these simulations was to investigate several surface plasma generations models under Z conditions for comparison with experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resolving the Proton Form Factor Problem with Positron-Proton Scattering

The proton electromagnetic form factors are essential pieces of our knowledge of nucleon structure. However, Rosenbluth separation measurements of the proton electric form factor, $G_E(Q^2)$, differ from polarization transfer measurements by a factor of three at $Q^2 = 5.6$ (GeV/$c$)$^2$. This discrepancy must be resolved. One possible resolution is to include the contribution of hard two-photon exchange (TPE) contributions. These contributions are very difficult to calculate. However, we can directly determine the TPE effect by measuring the ratio of the positron-proton to electron-proton elastic scattering cross sections, $R=\sigma(e^+p)/\sigma(e^-p)$, because the TPE amplitude has the same sign as the $e^+p$ born amplitude and the opposite sign as the $e^-p$ born amplitude. We have measured $R$ over a wide range of momentum transfer, $0.2 \le Q^2 \le 2$ GeV$^2$, and virtual photon polarization, $0.1 \le \epsilon \le 0.9$, using a mixed identical beam of electrons and positrons in Hall B at Jefferson Lab. This talk will describe the experimental techniques used to produce this beam, the analysis techniques to identify elastic scattering events, and some preliminary results.

Weinstein, Lawrence↗

The proton form factor ratio results from Jefferson Lab

The ratio of the proton form factors, GE p/GMp, has been measured extensively, from Q2 of 0.5 GeV2 to 8.5 GeV2, at the Jefferson Laboratory, using the polarization transfer method. This ratio is extracted directly from the measured ratio of the transverse and longitudinal polarization components of the recoiling proton in elastic electron-proton scattering. The polarization transfer results are of unprecedented high precision and accuracy, due in large part to the small systematic uncertainties associated with the experimental technique. There is an approved experiment at JLab, GEP(5), to continue the ratio measurements to 12 GeV2. A dedicated experimental setup, the Super Bigbite Spectrometer (SBS), will be built for this purpose. It will be equipped with a focal plane polarimeter to measure the polarization of the recoil protons. The scattered electrons will be detected in an electromagnetic calorimeter. In this presentation, I will review the status of the proton elastic electromagnetic form factors and discuss a number of theoretical approaches to describe nucleon form factors.

43 PARTICLE ACCELERATORS↗

Capacitance-Based Dimensional Change Sensors for In-Pile Materials Measurements

Advanced fuel compositions, such as accident tolerate fuels (ATF), are an active area of developing in the nuclear power industry. The long-term performance of these newly developed fuels is estimated through physics-based simulation models of irradiation-, temperature-, pressure-, etc.-induced material degradation. As these fuels are deployed in test reactors, measurement and characterization of the fuel pin evolution is used to validate prediction models. In-pile material evolution parameters, such as fuel rod pressurization, fuel stack and cladding elongation, and cladding diameter, are commonly measured using a linear voltage differential transformer (LVDT). However, LVDTs are bulky and limited to lower (350-500C) temperature operation. The high power density and small size of most experimental positions in high performance research reactors used for accelerated materials irradiation studies generally precludes the use of LVDTs in these reactors. There is a critical need for sensors that provide real-time data regarding material evolution under highly accelerated irradiation. These sensors would ideally have a small profile and the ability to withstand irradiation at extremely high dose rates and temperatures for extended periods of time. A capacitance-based sensor is currently under development at the University of Tennessee to provide a direct measurement of in-pile dimensional change during irradiation. Sensor response was simulated using AutoCAD Electromagnetic field simulator (EMS) for a variety of sensor materials and configurations and fuel pin swelling conditions. Initial results of these simulations are summarized and areas of ongoing research and development are discussed.

Naughton, Tyler↗

Broadband Characterization and Circuit Model Development of Transmission-Scale Transformers

This report describes broadband measurements of transmission-scale transformers typical in the electric power grid. This work was performed as part of the EMP Resilient Grid LDRD project at Sandia National Laboratories to generate circuit models that can be used for high-altitude electromagnetic pulse (HEMP) coupling simulations and response predictions. The objective of the work was to obtain characterization data of substation yard equipment across a frequency range relevant to HEMP. Vector network analyzer measurements up to 100 MHz were performed on two power transformers at ABB-Hitachi and a single ITEC potential transformer. Custom cable breakouts were designed to interface with the transformer terminals and provide ground connections to the chassis at the base of the transformer bushings. The three-phase terminals of the power transformers were measured as a common mode impedance using a parallel resistive splitter, and the single-phase terminals of the potential transformer were measured directly. A vector fitting algorithm was used to empirically fit circuit models to the resulting two-port networks and input impedances of the measured objects. Simplified circuit representations of the input impedances were also generated to assess the degree of precision needed for high-altitude electromagnetic pulse response predictions, which were performed in Sandia's XYCE circuit simulator platform. HEMP coupling simulations using the transformer models showed significant reduction in the voltage peak and broadening in the pulse width seen at the power transformer compared to the traveling wave voltage. This indicated the importance of the load condition when defining the coupled insult in an electric power substation. Simplified circuit models showed a similar voltage at the transformer with a smoothed waveform. The presence of potential transformers in the simulation did not significantly change the simulated voltage at the power transformer. Single-port input impedance models were also developed to define load conditions when transfer characteristics were not necessary.

24 POWER TRANSMISSION AND DISTRIBUTION↗