Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Doppler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Non-Mechanical Beam Steering for NASA's Navigation Doppler LiDAR

Transparent electro-optic (EO) devices can potentially be used for efficient, high speed, and low mass non-mechanical beam steering. Transmission through EO devices will affect the wavefront quality and aberration of both the transmitted and received laser light. The consequences of wavefront distortions on coherent detection are not fully understood. Therefore, we have tested the performance of coherent detection lidar using liquid crystal polarization grating (LCPG) beam steering device. We will discuss the impact of LCPG beam steering devices on the performance of NASA’s Navigation Doppler Lidar, built for providing altitude and vector velocity data to aerial and space vehicles.

Lidar↗

Millimeter Wave Doppler Radar Testing Using the Lunar Regolith Ejecta Simulator

A linear conveyor system has been devised to maintain lunar regolith simulant at a range of velocities, distances, angles, particle densities, and particle sizes. The Lunar Regolith Ejecta Simulator (LuRES) system shall test prototype and potential flight instrumentation for measuring the velocities of regolith particles accelerated by a plume-surface interaction (PSI) and determining effects of particle number densities and particle size distributions on return signals. Here we present the results of initial LuRES testing of the Millimeter Wave Doppler Radar (MWDR) instrument. The LuRES system held a single, ~900 µm BP-1 lunar regolith simulant particle at a continuous ~5 m/s velocity. The return signal of the MWDR from this LuRES configuration was analyzed to calibrate the MWDR instrument. Further testing is planned for the remaining of 2023 to calibrate the MWDR for various particle sizes and densities at a continuous velocity. These results will be presented in the final paper.

PSI↗

AWP: NASA's Aerosol Wind Profiler Coherent Doppler Wind Lidar

A new airborne coherent Doppler Wind Lidar (DWL) instrument has been implemented leveraging NASA's development of the 2-micron Wind-Space Pathfinder (Wind-SP) lidar transceiver. A technology development project, Wind-SP refined and demonstrated numerous components required for a coherent-detection space wind lidar instrument. Aerosol Wind Profiler (AWP) transitioned this transceiver into an airborne wind lidar capable of providing full 3-D wind vector retrievals. AWP operates with laser pulse energy and repetition rate combination required for high spatial and vertical resolution wind profiling from space. Operation from aircraft platforms will yield very strong signal return required for detailed process studies at <2km spatial and <100m vertical resolution under most conditions. AWP will serve as NASA’s wind calibration and validation instrument for future space-based wind observations over the coming decades, while also providing data supporting space wind lidar simulation studies. The AWP instrument is introduced and preliminary results from recent AWP demonstration flights are presented.

AWP↗

Dust Ejecta RADAR Technology (DERT): A Millimeter Wave Doppler Radar to Measure Plume Surface Interaction Ejecta Velocities

A novel method to measure the velocity of ejecta generated by the impingement of rocket plumes on a lunar or planetary surface is presented. Dust Ejecta RADAR Technology (DERT), is a Millimeter Wave Doppler Radar sensor that provides a unique dataset based on direct measurements of ejecta particle velocities during plume-surface interactions, which will help inform risk assessments associated with impacts by high-speed ejecta particles. DERT has measured velocities of a pendulum (~1 m/s), a rotating strip (60 m/s), projected regolith simulant BP-1 (~250 m/s) and rifle rounds (~820 m/s). Signal-to-noise ratios of up to 60 dB with regolith simulant BP-1 have been demonstrated with a CW 94 GHz unit. Data collected from DERT will inform the development of high-fidelity computational models of plume-surface interaction effects and will help address NASA Strategic Knowledge Gaps related to characterizing entry, descent and landing effects, and the risks associated with high-speed ejecta on the lander and lunar surface assets. Recent efforts to develop DERT as a flight instrument are presented as well as the development of a Lunar Regolith Ejecta Simulator (LuRES) system to calibrate DERT.

PSI↗

NASA’s Aerosol Wind Profiler (AWP) Coherent Doppler Wind LiDAR

NASA’s Langley Research Center recently completed development of the Aerosol Wind Profiler (AWP) suborbital, 2 µm coherent Doppler wind lidar (CDWL) instrument. The AWP instrument is presented, and the Jan 2023 flight demonstration configuration is described. Data from these demonstration flights are presented. AWP was developed with support from NASA’s Earth Science Technology Office, Earth Science Division, and LaRC Science Directorate.

AWP↗

Coherent Doppler Wind Lidar Suborbital and Orbital Activities at NASA Langley Research Center

NASA’s Langley Research Center recently completed development of the Aerosol Wind Profiler (AWP) suborbital coherent Doppler wind lidar (CDWL) instrument. Developed with support from NASA’s Earth Science Technology Office, Earth Science Division, and LaRC Science Directorate, the AWP project adapted the Wind-SP 2 µm transceiver for airborne use. AWP successfully completed demonstration and engineering test flights in January 2023. LaRC has been funded by a NOAA Joint Venture program Suborbital 3-D Wind Measurement Demonstration project to collect and provide AWP data. The first campaign collected > 50 hours of data during the October 2023 EcoDemonstrator campaign on the NASA DC-8, samples of which will be presented here. AWP implemented and demonstrated multiple technologies needed for a space CDWL transceiver, which have continued development towards miniaturization and ruggedization. A space-based CDWL study is being completed that leverages these recent developments, informing a vision for a relatively low-cost orbital CDWL mission that will also be introduced.

AWP↗

Demonstration of Navigation Doppler Lidar Capabilities Onboard the First Commercial Lunar Lander

Landing on the Moon safely, softly, and precisely is still an extremely difficult task to achieve. Navigation Doppler Lidar (NDL) was designed to provide a solution to spaceflight landing vehicles in achieving this task. NDL is a high-performance, compact, and cost-effective velocity and altitude measurement instrument that has been developed, tested and improved over many years. Testing has now culminated with NDL’s successful operation on two spaceflight vehicles this year: Astrobotic’s Peregrine lunar lander and Intuitive Machines’ Odysseus lunar lander. Odysseus became the first U.S. vehicle to land successfully on the Moon since Apollo 17. The performance data obtained by NDL during the Intuitive Machines mission is exceptional, and this mission fully demonstrated NDL’s ability to produce critical velocity and altitude data for future robotic and human exploration missions to the Moon and other planetary bodies. This paper will give an overview of NDL briefly describing its history, architecture, and theory of operation. NDL’s system checkout on Astrobotic’s Peregrine lunar lander is then discussed followed by NDL’s performance during the Intuitive Machines Odysseus lunar lander mission. A description of how the data acquired by NDL is then used to perform trajectory reconstruction and animation is then provided. Finally, this paper concludes with potential uses of NDL’s acquired mission data to future applications.

Lunar Landing↗

Demonstration of Navigation Doppler Lidar Capabilities Onboard the First Commercial Lunar Lander

Landing on the Moon safely, softly, and precisely is still an extremely difficult task to achieve. Navigation Doppler Lidar (NDL) was designed to provide a solution to spaceflight landing vehicles in achieving this task. NDL is a high-performance, compact, and cost-effective velocity and altitude measurement instrument that has been developed, tested and improved over many years. Testing has now culminated with NDL’s successful operation on two spaceflight vehicles this year: Astrobotic’s Peregrine lunar lander and Intuitive Machines’ Odysseus lunar lander. Odysseus became the first U.S. vehicle to land successfully on the Moon since Apollo 17. The performance data obtained by NDL during the Intuitive Machines mission is exceptional, and this mission fully demonstrated NDL’s ability to produce critical velocity and altitude data for future robotic and human exploration missions to the Moon and other planetary bodies. This paper will give an overview of NDL briefly describing its history, architecture, and theory of operation. NDL’s system checkout on Astrobotic’s Peregrine lunar lander is then discussed followed by NDL’s performance during the Intuitive Machines Odysseus lunar lander mission. A description of how the data acquired by NDL is then used to perform trajectory reconstruction and animation is then provided. Finally, this paper concludes with potential uses of NDL’s acquired mission data to future applications.

Lunar Landing↗

Doppler effects on 3-D non-LTE radiation transport and emission spectra.

Spatially and temporally resolved X-ray emission lines contain information about temperatures, densities, velocities, and the gradients in a plasma. Extracting this information from optically thick lines emitted from complex ions in dynamic, three-dimensional, non-LTE plasmas requires self-consistent accounting for both non-LTE atomic physics and non-local radiative transfer. We present a brief description of a hybrid-structure spectroscopic atomic model coupled to an iterative tabular on-the-spot treatment of radiative transfer that can be applied to plasmas of arbitrary material composition, conditions, and geometries. The effects of Doppler line shifts on the self-consistent radiative transfer within the plasma and the emergent emission and absorption spectra are included in the model. Sample calculations for a two-level atom in a uniform cylindrical plasma are given, showing reasonable agreement with more sophisticated transport models and illustrating the potential complexity - or richness - of radially resolved emission lines from an imploding cylindrical plasma. Also presented is a comparison of modeled L- and K-shell spectra to temporally and radially resolved emission data from a Cu:Ni plasma. Finally, some shortcomings of the model and possible paths for improvement are discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Convergence of Legendre Expansion of Doppler-Broadened Double Differential Elastic Scattering Cross Section

Convergence properties of Legendre expansion of a Doppler-broadened double-differential elastic neutron scattering cross section of {sup 238}U near the 6.67 eV resonance at temperature 10{sup 3} K are studied. A variance of Legendre expansion from a reference Monte Carlo computation is used as a measure of convergence and is computed for as many as 15 terms in the Legendre expansion. When the outgoing energy equals the incoming energy, it is found that the Legendre expansion converges very slowly. Therefore, a supplementary method of computing many higher-order terms is suggested and employed for this special case.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sub-Doppler Stark Spectroscopy in the A−X (1,0) Band of CN

The effect of external electric fields has been measured in hyperfine-resolved sub-Doppler transitions in the A {sup 2}{Pi}-X {sup 2}{Sigma} (1,0) band of the CN radical near 10900 cm{sup -1}. Static electric fields less than 1 kV/cm are sufficient to mix the most closely spaced {Lambda}-dpublets in the A state, leading to Stark spectra with both new and shifted resonances. Simulations of the saturation-dip Stark spectral line profiles allow extraction of the A-state permanent electric dipole moment with a magnitude of 0.06 {+-} 0.02 D.

74 ATOMIC AND MOLECULAR PHYSICS↗

Photonic Doppler Velocimetry Multiplexing Techniques: Evaluation of Photonic Techniques

This poster reports progress related to photonic technologies. Specifically, the authors developed diagnostic system architecture for a Multiplexed Photonic Doppler Velocimetry (MPDV) that incorporates frequency and time-division multiplexing into existing PDV methodology to provide increased channel count. Current MPDV design increases number of data records per digitizer channel 8x, and also operates as a laser-safe (Class 3a) system. Further, they applied heterodyne interferometry to allow for direction-of-travel determination and enable high-velocity measurements (>10 km/s) via optical downshifting. They also leveraged commercially available, inexpensive and robust components originally developed for telecom applications. Proposed MPDV architectures employ only commercially available, fiber-coupled hardware.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Fisheye Lens as a Photonic Doppler Velocimetry Probe

These presentation visuals report an instrument that, by use of a fish-eye lens, generates a beat signal using fiber mixing of unshifted light with Doppler-shifted light and measures the beat frequency. Ray trace diagrams are shown to illustrate advantages and disadvantages. The authors find their instrument has a long tracking distance, and large angle coverage. Index matching eases assembly, reduces return loss and flattens the field.

47 OTHER INSTRUMENTATION↗

XDV: A proposal for an X-ray Doppler Velocimetry diagnostic

Presentation describes proposal to arrange several bent crystals, each tuned to a different center wavelength within the motional Doppler-broadened profile of a suitable x-ray emission line, to produce a multispectral image that maps wavelength shift to line-of-sight velocity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the Stopping Power of Water for Carbon Ions Using Inverted Doppler Shift Attenuation

Carbon ion therapy has gained importance in cancer treatment due to its locally well confined dose distribution, but there is a significant lack of experimental data which is needed for dose calculations and estimation of biological damage. Since tissue is mainly comprised of water, the energy-dependent stopping power of water is the critical measure. Importantly, previous data gathered from experiments with light ions has been limited to water vapour and ice and neglected water in its liquid phase. Additionally, theoretical models regarding the stopping power cannot yet describe the complex charge transfer interactions of the projectile at velocities in the range of the mean velocity of the valence electrons of the traversed medium. There are also discrepancies in the amount of phase effects concerning water and water vapour cross sections. Despite its importance there exists no experimental data for the stopping power of water for carbon ions in the energy region between 1 MeV and 5 MeV. This may be due to the short track length of carbon ions which makes traditional transmission experiments unfeasible. Therefore a project was launched to measure the stopping power of liquid water for carbon ions in the vicinity of the Bragg peak which corresponds to the energy regime of the maximum stopping power. For this measurement the inverted Doppler shift attenuation method was used. This uses the gamma quanta emitted from excited carbon nuclei which are produced by means of the {sup 12}C(α,α'){sup 12}C* reaction. The recorded γ-spectra contain the information of the projectiles velocity at the time they decay to their ground state and an internal clock provided by the exponential decay law. The deceleration of the projectile is directly connected to the stopping power which can be determined with this method as a function of the projectiles kinetic energy. Further measurements have been carried out to improve the experimental method. The setup and the preliminary results of this study will be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of KENO Thermal Moderator Doppler Broadening Method in SCALE 6.2 Beta5 Using Continuous-Energy B-VII.1 Library

KENO, the Monte Carlo criticality safety program within the SCALE code package, has until recently used continuous-energy (CE) cross sections corresponding to the set of evaluated nuclear data closest to the temperature of interest. This method, which is used for both 1-D cross sections and thermal scattering probability data, does not fully represent the phenomenon of Doppler broadening (DB) and can result in significant differences in eigenvalues when the material temperature lies between the evaluated data sets. A method for creating temperature-dependent nuclear data has been implemented in KENO for CE calculations. This work summarizes the results of incorporating this method into two critical experiments using low-enriched uranium (LEU) in light water moderated pin lattices. The LEUCOMP-THERM-046 (LCT-046) experiment is a benchmark documented in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook); it consists of 22 critical configurations or cases. The KRITZ-2:1 experiment, a part of the International Reactor Physics Experiment Evaluation Project (IRPhEP), consists of two cases which span a significant range of moderator temperatures. The results of this work give a good indication of the value of the newly incorporated cross section processing. However, more diverse evaluations should be performed to provide a broader validation of this method. The results suggest that when dealing with systems similar to LCT-046, there is a significant improvement made when the moderator scattering data are properly broadened and sampled. The DB of the hydrogen (in water) 2-D cross sections resulted in a consistent C/E value across the temperature range, whereas the DB of the 1-D only cross sections did not exhibit this improvement. With respect to criticality safety, this consistency adds precision to the calculational method, which could potentially impact subcriticality limits. After comparing the KRITZ and LCT-046 results, the most plausible conclusion to make as to why the added thermal moderator treatment improved the results for LCT-046 and not for the KRITZ experiment is that the two systems were dissimilar with respect to their temperatures. That is, the relative temperature differences among the cases in each experiment are more significant for LCT-046 than for KRITZ. The cross section changes as a function of temperature are also smaller at higher temperatures. This difference resulted in a lesser impact of broadening in general for the KRITZ hot case.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rain retrieval from dual-frequency radar Doppler spectra: validation and potential for a midlatitude precipitating case-study

A recently developed technique retrieving the binned raindrop size distributions (DSDs) and air state parameters from ground-based K a and W-band radars Doppler spectra profiles is improved and applied to a typical midlatitude rain event. The retrievals are thoroughly validated against DSD observations of a 2D video disdrometer and independent X-band observations. Here for this case-study, profiles of rain rate, R, mean volume diameter and concentration parameter are retrieved, with low bias and standard deviations. In light rain (0.1 < R < 1 mm h -1 ), the radar reflectivities must be calibrated with a collocated disdrometer which introduces random errors due to sampling mismatch between the two instruments. The best performances are obtained in moderate rain (1 < R < 20 mm h -1 ) where the retrieval is providing self-consistent estimates of the absolute calibration and of the attenuation caused by antenna or radome wetness for both radars.

54 ENVIRONMENTAL SCIENCES↗