Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Distributed generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

A probabilistic analysis of cumulative carbon emissions and long-term planetary warming

Efforts to mitigate and adapt to long-term climate change could benefit greatly from probabilistic estimates of cumulative carbon emissions due to fossil fuel burning and resulting CO 2 -induced planetary warming. Here we demonstrate the use of a reduced-form model to project these variables. We performed simulations using a large-ensemble framework with parametric uncertainty sampled to produce distributions of future cumulative emissions and consequent planetary warming. A hind-cast ensemble of simulations captured 1980–2012 historical CO 2 emissions trends and an ensemble of future projection simulations generated a distribution of emission scenarios that qualitatively resembled the suite of Representative and Extended Concentration Pathways. The resulting cumulative carbon emission and temperature change distributions are characterized by 5–95th percentile ranges of 0.96–4.9 teratonnes C (Tt C) and 1.4 °C–8.5 °C, respectively, with 50th percentiles at 3.1 Tt C and 4.7 °C. Within the wide range of policy-related parameter combinations that produced these distributions, we found that low-emission simulations were characterized by both high carbon prices and low costs of non-fossil fuel energy sources, suggesting the importance of these two policy levers in particular for avoiding dangerous levels of climate warming. With this analysis we demonstrate a probabilistic approach to the challenge of identifying strategies for limiting cumulative carbon emissions and assessing likelihoods of surpassing dangerous temperature thresholds.

54 ENVIRONMENTAL SCIENCES↗

Low-temperature Stirling Engine for Geothermal Electricity Generation

Up to 2700 terawatt-hours per year of geothermal electricity generation capacity has been shown to be available within North America, typically with wells drilled into geologically active regions of the earth's crust where this energy is concentrated (Huttrer, 2001). Of this potential, about half is considered to have temperatures high enough for conventional (steam-based) power production, while the other half requires unconventional power conversion approaches, such as organic Rankine cycle systems or Stirling engines. If captured and converted effectively, geothermal power generation could replace up to 100GW of fossil fuel electric power generation, leading to a significant reduction of US power sector emissions. In addition, with the rapid growth of hydro-fracking in oil and gas production, there are smaller-scale distributed power generation opportunities in heated liquids that are co-produced with the main products. Since 2006, Cool Energy, Inc. (CEI) has designed, fabricated and tested four generations of low-temperature (100°C to 300°C) Stirling engine power conversion equipment. The electric power output of these engines has been demonstrated at over 2kWe and over 16% thermal conversion efficiency for an input temperature of 215°C and a rejection temperature of 15°C. Initial pilot units have been shipped to development partners for further testing and validation, and significantly larger engines (20+ kWe) have been shown to be feasible and conceptually designed. Originally intended for waste heat recovery (WHR) applications, these engines are easily adaptable to geothermal heat sources, as the heat supply temperatures are similar. Both the current and the 20+ kWe designs use novel approaches of self-lubricating, low-wear-rate bearing surfaces, non-metallic regenerators, and high-effectiveness heat exchangers. By extending CEI's current 3 kWe SolarHeart® Engine into the tens of kWe range, many additional applications are possible, as one 20 kWe design produces nearly seven times the power output of the 3 kWe unit but at only 2.5 times the estimated fabrication cost. Phase I of the proposed SBIR program will therefore study the feasibility of generating electricity with one or more 20 kWe or larger Stirling engines, powered by geothermal heat produced by current and possibly some forward-looking borehole extraction methods, and from producing oil and gas wells. The feasibility study will include full analysis of the thermodynamic and heat transfer processes within the engine (necessary to produce optimum theoretical designs and performance maps), the cost of pumping the geothermal heat recovery fluid, and how the system tradeoffs impact the overall system economics. The goal is a geothermal system design that could be demonstrated during a Phase II follow-on program at a field test site.

15 GEOTHERMAL ENERGY↗

BayoTech Risk and Modeling Support

This white paper describes the work performed by Sandia National Laboratories in the New Mexico Small Business Agreement with BayoTech. BayoTech is a hydrogen generation and distribution company that is located in Albuquerque, NM. Their goal is to distribute hydrogen via their hydrogen systems which utilize the core design that was developed by Sandia. However, because the hydrogen economy is in its nascency, the safety and operation of the generating systems require independent validation. Additionally, in their pursuit of permitting at various locations around the nation, they require fire protection engineering support in discussions with local fire marshals and neighboring industrial entities. Sandia National Laboratories has subject matter expertise in hydrogen risk modeling of consequence (overpressure and dispersion) as well as fire protection engineering. Throughout this project, Sandia has worked with BayoTech to provide our expertise in these subject areas to facilitate the market entry of their hydrogen generation project to address the dire need for decarbonization due to climate change. The general approach of the support by Sandia is outlined in the main body, while the location specific evaluation for the Port of Stockton is contained in Appendix A.

08 HYDROGEN↗

A New Distributed Model-Free Control Strategy to Diminish Distribution System Voltage Violations

This paper proposes a new distributed model-free control (MFC) strategy for dynamic voltage control to diminish distribution systems' voltage violations. The objective is to maintain all critical load bus voltages within the acceptable ANSI Range A (+/- 5% of nominal). The distributed MFC strategy, which only requires local voltage measurements from designated load buses, controls online the reactive power generation of available synchronous generator (SG)-based and photovoltaic (PV)-based distributed generators (DGs). The distributed MFC strategy is computationally efficient and does not require modelling of the different system components and disturbances. Time-domain dynamic simulations are conducted for the 21-bus test distribution system fed by multiple DGs to verify the performance of the proposed MFC strategy, and the results are compared against the conventional model-based microgrid voltage stabilizer (MGVS) control strategy. The simulation results show that the distributed MFC strategy provides minimal voltage violations and achieves the dynamic voltage stability of the system under diverse disturbances.

Hatipoglu, Kenan↗

Investigation of Relevant Distribution System Representation With DG for Voltage Stability Margin Assessment

This paper emphasizes the importance of including unbalanced distribution systems for voltage stability studies in power systems. The paper aims to: discuss the various simulation methods for power system analysis; highlight the need for modeling unbalanced distribution system for accurate load margin assessment; demonstrate the influence of net-load unbalance (NLU) on voltage stability margin (VSM). We also share a T&D co-simulation interface with commercial power system solvers. The distribution system is evolving rapidly with high proliferation of distributed energy resources (DERs); these are not guaranteed to proliferate in a balanced manner and uncertainty resulting due to these DERs is well acknowledged. These uncertainties cannot be captured or visualized without representing the distribution system in detail along with the transmission system. We show the impact of proliferation of DERs in various 3-phase proportions on voltage stability margin through T&D co-simulation. We also study the impact of volt/VAR control on voltage stability margin. This analysis is only possible by representing the distribution system in detail through T&D co-simulation. In conclusion, higher percentage of net-load unbalance (NLU) in distribution system aggravates the voltage stability margin of the distribution system, which can further negatively influence the overall voltage stability margin of the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Endogenous Assessment of the Capacity Value of Solar PV in Generation Investment Planning Studies

There exist several different reliability-and approximation-based methods to determine the contribution of solar resources toward resource adequacy. However, most of these approaches require knowing in advance the installed capacities of both conventional and solar generators. This is a complication since generator capacities are actually decision variables in capacity planning studies. In this paper, we study the effect of time resolution and solar PV penetration using a planning model that accounts for the full distribution of generator outages and solar resource variability. We also describe a modification of a standard deterministic planning model that enforces a resource adequacy target through a reserve margin constraint. Our numerical experiments show that at least 50 days worth of data are necessary to approximate the results of the full-resolution model with a maximum error of 2.5% on costs and capacity. We also show that the amount of displaced capacity of conventional generation decreases rapidly as the penetration of solar PV increases. We find that using an exogenously defined and constant capacity value based on time-series data can yield relatively accurate results for small penetration levels. For higher penetration levels, the modified deterministic planning model better captures avoided costs and the decreasing value of solar PV.

14 SOLAR ENERGY↗

Endogenous Assessment of the Capacity Value of Solar PV in Generation Investment Planning Studies. Draft

There exist several different reliability- and approximation-based methods to determine the capacity contribution of solar resources towards resource adequacy. However, most of these approaches require knowing in advance the installed capacities of both conventional and solar generators. This is a complication since generator capacities are actually decision variables in capacity planning studies. In this article we study the effect of time resolution and solar PV penetration using a capacity planning model that accounts for the full distribution of generator outages and solar resource variability. We also describe a modification of a standard deterministic planning model that enforces a resource adequacy target through a reserve margin constraint. Our numerical experiments show that at least 50 days worth of data are necessary to approximate the results of the full-resolution model with a maximum error of 2.5% on costs and capacity. We also show that the amount of displaced capacity of conventional generation decreases rapidly as the penetration of solar PV increases. We find that using an exogenously defined and constant capacity factor based on time-series data can yield relatively accurate results for small penetration levels (less than 5%). For higher penetration levels (up to 20%), the modified deterministic planning model better captures avoided costs and the decreasing value of solar PV. Although our results are not general, they highlight the importance of accounting for the variation in both energy and capacity value of solar resources endogenously in capacity planning models. A11 numerical experiments are performed using the IEEE Reliability Test System and 7 years worth of demand and solar data from a utility in Arizona.

14 SOLAR ENERGY↗

Can Wholesale Electricity Markets Achieve Resource Adequacy and High Clean Energy Generation Targets in the Presence of Self-Interested Actors?

Wholesale electricity markets are intended to incentivize system generation investments and operations outcomes that meet evolving system needs. In this work, we evaluate the effectiveness of wholesale market structures, rules and policies in achieving system resource adequacy (RA) and clean energy targets in the presence of self-interested generation investors using the Electricity Markets and Investment Suite Agent-based Simulation (EMIS-AS) model. Results highlight that both capacity markets and operating reserve demand curves (ORDCs) can help achieve a reliable system but with different RA compliance timelines and distribution of generation technologies. Structures with capacity markets tend to favor more capital-intensive peaking technologies while reducing wind and solar build-outs due to suppressed energy and clean energy market prices, particularly in the absence of strong clean energy targets. Conversely, ORDCs improve the commitment of available generation units, but this comes at the expense of higher system costs and renewable generation curtailment. We also find that well-calibrated static capacity demand curves can yield similar reliability and total cost compared to capacity market demand curves informed dynamically by resource adequacy while also yielding stable annual capacity prices. Different approaches to formulating ORDC curves can also yield key trade-offs, namely that a more efficient treatment of storage chronology results in lower ORDC curves and prices, yielding less investment and cost but at the expense of reliability. Finally, the effectiveness of wholesale electricity markets in practically achieving very high clean energy generation targets highly depends on the cost-competitiveness of clean energy technologies that can support critical balancing needs across multiple timescales.

capacity expansion↗

Photovoltaic and Behind-the-Meter Battery Storage: Advanced Smart Inverter Controls and Field Demonstration

Electric utilities have little visibility of the electrical distribution system, and consequently, limited diagnostic capabilities. The distribution grid was designed for a unidirectional power flow, where energy is supplied by few large centralized power plants; however, this is set to change to meet California’s aggressive decarbonization goals. The large-scale deployment of distributed renewable generation, such as photovoltaics (PV), can have many negative effects on an unprepared grid. As illustrated in the California “duck curve,” PV generation modifies load profiles during the day, which causes steep ramping in the evening. This effect indicates the need to revise the electrical grid’s design and operation. This project sought to (a) create a centralized resource in California to test and validate distribution technology controls with industry standard PV, storage, and high-fidelity sensors, (b) support strategic and operational decisions for new grid architectures by providing simulation models, (c) promote new ways to control clusters of PV smart inverters, in accordance with California Rule 21, and (d) innovate, develop, and field test a predictive controller to maximize economic profit for the customer while supporting the grid. The controller was built using the state-of-the-art model predictive control methodology to optimally control behind-the-meter PV and battery storage. In consideration of the duck curve, the controller optimally controls the battery dispatch by charging during excess generation periods and discharging during the critical afternoon demand hours. The controller was evaluated in annual simulations and revealed the potential cost-effectiveness of behind-the-meter battery storage. The simulations showed that the annual electricity bill could be reduced by as much as 35 percent, with a payback period of the investment in battery storage in about 6 years – significantly shorter than the manufacturer’s 10-year warranty. All developed simulation models, the grid event library, and the MPC controller are open-source and available online.

Model Predictive control↗

Model/Measurement Comparison of the Transverse Phase Space Distribution of an RFQ-Generated Bunch at the SNS BTF

The research program at the SNS Beam Test Facility is focused on resolving observed model/measurement discrepancies that preclude accurate loss prediction in high-power linacs. The current program of study is focused on deploying direct 6D measurements to reconstruct a realistic model of the initial beam distribution at the RFQ output. This detailed characterization also provides an opportunity for benchmark of RFQ simulations. Here we compare PARMTEQ predictions against 5D-resolved (x, x’, y, y’, dE) phase space measurements of the BTF H⁻ bunch, focusing on the transverse distribution. This work is an extension of [1], which focused on the longitudinal phase space.

Ruisard, Kiersten↗

Semiautomated head-and-neck IMRT planning using dose warping and scaling to robustly adapt plans in a knowledge database containing potentially suboptimal plans

Purpose: Prior work by the authors and other groups has studied the creation of automated intensity modulated radiotherapy (IMRT) plans of equivalent quality to those in a patient database of manually created clinical plans; those database plans provided guidance on the achievable sparing to organs-at-risk (OARs). However, in certain sites, such as head-and-neck, the clinical plans may not be sufficiently optimized because of anatomical complexity and clinical time constraints. This could lead to automated plans that suboptimally exploit OAR sparing. This work investigates a novel dose warping and scaling scheme that attempts to reduce effects of suboptimal sparing in clinical database plans, thus improving the quality of semiautomated head-and-neck cancer (HNC) plans. Methods: Knowledge-based radiotherapy (KBRT) plans for each of ten “query” patients were semiautomatically generated by identifying the most similar “match” patient in a database of 103 clinical manually created patient plans. The match patient’s plans were adapted to the query case by: (1) deforming the match beam fluences to suit the query target volume and (2) warping the match primary/boost dose distribution to suit the query geometry and using the warped distribution to generate query primary/boost optimization dose-volume constraints. Item (2) included a distance scaling factor to improve query OAR dose sparing with respect to the possibly suboptimal clinical match plan. To further compensate for a component plan of the match case (primary/boost) not optimally sparing OARs, the query dose volume constraints were reduced using a dose scaling factor to be the minimum from either (a) the warped component plan (primary or boost) dose distribution or (b) the warped total plan dose distribution (primary + boost) scaled in proportion to the ratio of component prescription dose to total prescription dose. The dose-volume constraints were used to plan the query case with no human intervention to adjust constraints during plan optimization. Results: KBRT and original clinical plans were dosimetrically equivalent for parotid glands (mean/median doses), spinal cord, and brainstem (maximum doses). KBRT plans significantly reduced larynx median doses (21.5 ± 6.6 Gy to 17.9 ± 3.9 Gy), and oral cavity mean (32.3 ± 6.2 Gy to 28.9 ± 5.4 Gy) and median (28.7 ± 5.7 Gy to 23.2 ± 5.3 Gy) doses. Doses to ipsilateral parotid gland, larynx, oral cavity, and brainstem were lower or equivalent in the KBRT plans for the majority of cases. By contrast, KBRT plans generated without the dose warping and dose scaling steps were not significantly different from the clinical plans. Conclusions: Fast, semiautomatically generated HNC IMRT plans adapted from existing plans in a clinical database can be of equivalent or better quality than manually created plans. The reductions in OAR doses in the semiautomated plans, compared to the clinical plans, indicate that the proposed dose warping and scaling method shows promise in mitigating the impact of suboptimal clinical plans.

60 APPLIED LIFE SCIENCES↗

Conditional distribution estimation of building characteristics with diffusion models for urban energy modeling

Understanding current energy consumption behavior in communities is critical for informing future energy use decisions and enabling efficient energy management. Urban energy models, which are used to simulate these energy use patterns, require large datasets with detailed building characteristics for accurate outcomes. However, such detailed characteristics at the individual building level are often unknown and costly to acquire, or unavailable. Through this work, we propose using a generative modeling approach to generate realistic building attributes to fill in the data gaps and finally provide complete characteristics as inputs to energy models. Our model learns complex, building-level patterns from training on a large-scale residential building stock model containing 2.2 million buildings. We employ a tabular diffusion-based framework that is designed to handle heterogeneous (discrete and continuous) features in tabular building data, such as occupancy, floor area, heating, cooling, and other equipment details. We develop a capability for conditional diffusion, enabling the imputation of missing building characteristics conditioned on known attributes. We conduct a comprehensive validation of our conditional diffusion model, firstly by comparing the generated conditional distributions against the underlying data distribution, and secondly, by performing a case study for a Baltimore residential region, showing the practical utility of our approach. Our work is one of the first to demonstrate the potential of generative modeling to accelerate building energy modeling workflows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulating dispatchable grid services provided by flexible building loads: State of the art and needed building energy modeling improvements

End-use electrical loads in residential and commercial buildings are evolving into flexible and cost-effective resources to improve electric grid reliability, reduce costs, and support increased hosting of distributed renewable generation. This article reviews the simulation of utility services delivered by buildings for the purpose of electric grid operational modeling. We consider services delivered to (1) the high-voltage bulk power system through the coordinated action of many, distributed building loads working together, and (2) targeted support provided to the operation of low-voltage electric distribution grids. Although an exhaustive exploration is not possible, we emphasize the ancillary services and voltage management buildings can provide and summarize the gaps in our ability to simulate them with traditional building energy modeling (BEM) tools, suggesting pathways for future research and development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wind Power Ramping Product for Increasing Power System Flexibility

With increasing penetrations of wind power, system operators are concerned about a potential lack of system flexibility and ramping capacity in real-time dispatch stages. In this paper, a modified dispatch formulation is proposed considering the wind power ramping product (WPRP). A swinging door algorithm (SDA) and dynamic programming are combined and used to detect WPRPs in the next scheduling periods. The detected WPRPs are included in the unit commitment (UC) formulation considering ramping capacity limits, active power limits, and flexible ramping requirements. The modified formulation is solved by mixed integer linear programming. Numerical simulations on a modified PJM 5-bus System show the effectiveness of the model considering WPRP, which not only reduces the production cost but also does not affect the generation schedules of thermal units.

17 WIND ENERGY↗