At least 901 records · Page 50

Kinematics and constraints associated with swashplate blade pitch control

An important class of techniques to reduce helicopter vibration is based on using a Higher Harmonic controller to optimally define the Higher Harmonic blade pitch. These techniques typically require solution of a general optimization problem requiring the determination of a control vector which minimizes a performance index where functions of the control vector are subject to inequality constraints. Six possible constraint functions associated with swashplate blade pitch control were identified and defined. These functions constrain: (1) blade pitch Fourier Coefficients expressed in the Rotating System, (2) blade pitch Fourier Coefficients expressed in the Nonrotating System, (3) stroke of the individual actuators expressed in the Nonrotating System, (4) blade pitch expressed as a function of blade azimuth and actuator stroke, (5) time rate-of-change of the aforementioned parameters, and (6) required actuator power. The aforementioned constraints and the associated kinematics of swashplate blade pitch control by means of the strokes of the individual actuators are documented.

Leyland, Jane A.↗

Shape control of large space structures

A survey has been conducted to determine the types of control strategies which have been proposed for controlling the vibrations in large space structures. From this survey several representative control strategies were singled out for detailed analyses. The application of these strategies to a simplified model of a large space structure has been simulated. These simulations demonstrate the implementation of the control algorithms and provide a basis for a preliminary comparison of their suitability for large space structure control.

Hagan, M. T.↗

Jet vortex generators for turbulent flow separation control

A parametric study was performed with jet vortex generators to determine their effectiveness in controlling flow separation associated with low speed turbulent flow over a two dimensional rearward-facing ramp. Results indicate that flow separation control can be accomplished with the level of control achieved being a function of jet speed, jet orientation (with respect to the free stream direction), and orifice pattern (double row of jets vs. single row). Compared to slot blowing, jet vortex generators can provide an equivalent level of flow control over a larger spanwise region (for constant jet flow area and speed).

Selby, Gregory↗

Jet vortex generators for turbulent flow separation control

A parametric study was performed with jet vortex generators to determine their effectiveness in controlling flow separation associated with low-speed turbulent flow over a two-dimensional rearward-facing ramp. Results indicate that flow separation control can be accomplished with the level of control achieved being a function of jet speed, jet orientation (with respect to the free-stream direction), and orifice pattern (double row of jets vs. single row). Compared to slot blowing, jet vortex generators can provide an equivalent level of flow control over a larger spanwise region (for constant jet flow area and speed).

Selby, G.↗

Systems and methods for control system security

A resilient security agent determines a cyber and/or physical health of a control system by, inter alia, communicating cyber-physical key data through cyber-physical control paths of the system, and determining error introduced by the communication. The resilient security agent may be further configured to verify the integrity of acquired cyber-physical state information. The cyber health of the control system may be evaluated by comparing the acquired cyber state information to one or more cyber state profiles. The physical health of the control system may be evaluated by comparing the acquired physical state information to one or more physical state profiles.

97 MATHEMATICS AND COMPUTING↗

The employment of a spoken language computer applied to an air traffic control task.

Assessment of the merits of a limited spoken language (56 words) computer in a simulated air traffic control (ATC) task. An airport zone approximately 60 miles in diameter with a traffic flow simulation ranging from single-engine to commercial jet aircraft provided the workload for the controllers. This research determined that, under the circumstances of the experiments carried out, the use of a spoken-language computer would not improve the controller performance.

Laveson, J. I.↗

Data from Tests of a 1/5-Scale Model of a Proposed High-Speed Submarine in the Langley Full-Scale Tunnel

Tests of a 1/5 scale model of a proposed 153-foot high-speed submarine have been conducted in the Langley full-scale tunnel at the request of the Bureau of Ships, Department of the Navy. The test program included: (1) force tests to determine the drag, control effectiveness, and static stability characteristics for a number of model configurations, both in pitch and in yaw, (2) pressure measurements to determine the boundary-layer conditions and flow characteristics in the region of the propeller, and (3) an investigation of the effects of propeller operation on the model aerodynamic characteristics. In response to oral requests from the Bureau of Ships representatives t hat the basic data obtained in these tests be made available to them as rapidly as possible, this data report has been prepared to present some of the more pertinent results. All test results given in the present paper are for the propeller-removed condition and were obtained at a Reynolds number of approximately 22,300,000 based on model length.

Cocke, Bennie W.↗

Investigation of the Longitudinal Characteristics of a Large-Scale Jet Transport Model Equipped with Controllable Thrust Reversers

An investigation was conducted to determine the effect of thrust control by means of controllable thrust reversers on the longitudinal characteristics of a large-scale airplane model with a 35' sweptback wing of aspect ratio of 7 and four pylon-mounted jet engines equipped with target-type thrust reversers designed to provide thrust control ranging from full forward thrust to full reverse thrust. The thrust control in landing-approach configurations formed the major portion of the study. Results were obtained with both leading- and trailing-edge high-lift devices.

Hickey, David H.↗

Higher-Than-Conventional Radiation Doses in Localized Prostate Cancer Treatment: A Meta-analysis of Randomized, Controlled Trials

Purpose: To determine in a meta-analysis whether the outcomes in men with localized prostate cancer treated with high-dose radiotherapy (HDRT) are better than those in men treated with conventional-dose radiotherapy (CDRT), by quantifying the effect of the total dose of radiotherapy on biochemical control (BC). Methods and Materials: The MEDLINE, EMBASE, CANCERLIT, and Cochrane Library databases, as well as the proceedings of annual meetings, were systematically searched to identify randomized, controlled studies comparing HDRT with CDRT for localized prostate cancer. To evaluate the dose-response relationship, we conducted a meta-regression analysis of BC ratios by means of weighted linear regression. Results: Seven RCTs with a total patient population of 2812 were identified that met the study criteria. Pooled results from these RCTs showed a significant reduction in the incidence of biochemical failure in those patients with prostate cancer treated with HDRT (p < 0.0001). However, there was no difference in the mortality rate (p = 0.38) and specific prostate cancer mortality rates (p = 0.45) between the groups receiving HDRT and CDRT. However, there were more cases of late Grade >2 gastrointestinal toxicity after HDRT than after CDRT. In the subgroup analysis, patients classified as being at low (p = 0.007), intermediate (p < 0.0001), and high risk (p < 0.0001) of biochemical failure all showed a benefit from HDRT. The meta-regression analysis also detected a linear correlation between the total dose of radiotherapy and biochemical failure (BC = -67.3 + [1.8 x radiotherapy total dose in Gy]; p = 0.04). Conclusions: Our meta-analysis showed that HDRT is superior to CDRT in preventing biochemical failure in low-, intermediate-, and high-risk prostate cancer patients, suggesting that this should be offered as a treatment for all patients, regardless of their risk status.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)

This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach to determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Independent modal space control with positive position feedback

An independent modal space control (IMSC) algorithm is presented, whose modal control forces are generated from a positive position feedback (PPF) strategy. The proposed algorithm combines the attributes of both the IMSC and the PPF, and maintains the simplicity of the IMSC as it designs the controller of a complex structure at the uncoupled modal level. The effectiveness of the algorithm in damping out the vibration of flexible structures is validated experimentally. A simple cantilevered beam is employed as an example of a flexible structure whose multimodes of vibration are controlled by a single actuator. Performance of the active control system is determined in the frequency and the time domains. The experimental results indicate the potential of the proposed methodology as a viable method for controlling the vibration of large flexible structures.

Baz, A.↗

Some control considerations for ram-jet engines / c Seymour Himmel

Control requirements were determined from calculated engine performance maps for a fixed-geometry ram jet of a configuration suitable for strategic supersonic missile propulsion. Several control schemes for attaining desired engine performance and for stabilizing missile flight velocity during cruise are presented. The advantages and disadvantages of each system are discussed.

MISSILES↗

Numerical investigation of sound transmission through double wall cylinders with respect to active noise control

Market pressure for more fuel efficient air travel has led to increased use of turboprop and higher bypass turbofan engines. The low frequency components of propeller, jet and boundary layer noise are difficult to attenuate with conventional passive techniques. Weight and geometric restrictions for sound absorbing meterials limit the amount and type of treatment that may be applied. An active noise control (ANC) method is providing to be an attractive alternative. The approach taken in this paper uses a numerical finite/boundary element method (FEM/BEM) that may be easilty adapted to arbitrary geometries. A double walled cylinder is modeled using commercially available software. The outer shell is modeled as an aluminum cylinder, similar to that of aircraft skins. The inner shell is modeled as a composite material representative of a lightweight, stiff trim panel. Two different inner shell materials are used. The first is representative of current trim structure, the second a much stiffer composite. The primary source is generated by an exterior acoustic monopole. Control fields are generated using normal force inputs to the inner cylindrical shell. A linear least mean square (LMS) algorithm is used to determine amplitudes of control forces that minimize the interior acoustic field. Coupling of acoustic and structural modes and noise reductions are discussed for each of the inner shell materials.

Coats, T. J.↗

Some Tests and Calculations Pertaining to the Dive Path and to Wing and Tail Loads in the Accident to Eastern Airlines C54B Airplane, NC-88814, Near Bainbridge, Maryland, May 30, 1947

Several dive paths were calculated for a C54 airplane starting from level flight at an altitude of 4000 feet and from an initial indicated airspeed of 200 miles per hour. The results show that, within the limits of the possible paths permitted by the evidence of the crash at Bainbridge, the speed of impact would be about 370 miles per hour and the time to crash would be between 12 1/2 and 15 1/2 seconds. Tail load calculations indicate that, with moderate negative acceleration of the airplane, the tail would fail near the end of the dive in a manner consistent in several important respects with the evidence. A number of tests were made of the elevator tab control system to determine whether the tab would move by an amount sufficient to have caused the observed dive if the stored energy in the tab control cable were suddenly released. The results of these tests indicated that the probable tab movement is such as to be capable of causing a dive similar to the one observed at Bainbridge.

Rhode, Richard V.↗

Limitations of the Pilot in Applying Forces to Airplane Controls

Measurements were made to determine the relative maximum forces a pilot can exert on the controls of an airplane with the view of obtaining systematic data upon which to base the location of controls within the cockpit and the design of the control surfaces. A cockpit model of generous proportions, capable of being rotated to any attitude, was built with the location of the control stick and rudder pedals adjustable over a wide range of positions with respect to the seat. Besides measurements of maximum forces obtainable with various control locations and with the pilot in several attitudes, estimates of forces within the range normally encountered in flight were made to gain an indication of the accuracy of estimating control forces. The maximum aileron forces measured were of the order of 90 pounds, maximum elevator 200 pounds, and maximum rudder 450 pounds. The average forces applied with the controls in the neutral position for the various cockpit attitudes were of the order of 35, 95, and 400 pounds, respectively, for the ailerons, elevators, and rudder.

Gough, M N↗

Progress in multirate digital control system design

A new methodology for multirate sampled-data control design based on a new generalized control law structure, two new parameter-optimization-based control law synthesis methods, and a new singular-value-based robustness analysis method are described. The control law structure can represent multirate sampled-data control laws of arbitrary structure and dynamic order, with arbitrarily prescribed sampling rates for all sensors and update rates for all processor states and actuators. The two control law synthesis methods employ numerical optimization to determine values for the control law parameters. The robustness analysis method is based on the multivariable Nyquist criterion applied to the loop transfer function for the sampling period equal to the period of repetition of the system's complete sampling/update schedule. The complete methodology is demonstrated by application to the design of a combination yaw damper and modal suppression system for a commercial aircraft.

Berg, Martin C.↗

CWDM transmit module for wavelength tuning and tracking

A photonic integrated circuit (PIC) includes a semiconductor substrate with a main bus waveguide disposed within the substrate. Two or more ring lasers are disposed within the substrate and are optically coupled to the main bus waveguide. The ring lasers have a wavelength control mechanism allowing change of a lasers emitted wavelength. A wavelength selective filter is optically coupled to the bus waveguide. A control circuit is electronically coupled to each wavelength control mechanism, and the wavelength selective filter. The control circuit in conjunction with the selective filter allows monitoring of a ring laser's wavelength on the main bus waveguide. Based on a determined wavelength, the control circuit may change a ring laser wavelength to a desired wavelength to achieve a desired wavelength spacing for each of the ring lasers. The PIC may be integrated as a coarse wave-length division multiplexing (CWDM) transmit module.

42 ENGINEERING↗

Model Predictive Control for a Grid-interactive Efficient Thermal Storage-integrated Heat Pump System

Building heating and cooling systems can be used to overcome the mismatch between the intermittent supply of renewable power and the fluctuating demand for electricity. A novel underground thermal energy storage integrated with a dual-source heat pump has been proposed to mitigate the mismatch while meeting the thermal demand of buildings efficiently. Conventional thermostat control with heuristic rules cannot provide intelligent decisions to maximize the thermal efficiency and flexibility of the proposed system. Advanced control strategies like model predictive control (MPC) have provided a new paradigm for grid-interactive efficient building operation with the advancement of computation and sensing. This study developed an MPC for the proposed system to provide grid service for Demand Side Management and minimize the operating cost of building owners. A control-oriented dynamic model of the proposed system has been developed. Given an objective function and proper constraints, an optimization problem is formulated to determine the optimal control strategy of the system. Dynamic Programming is adopted to solve the optimization problem. A rule-based control (RBC) is also developed to achieve similar goals. Short-term simulations are conducted to compare the system performance resulting from the two controls. The simulation results indicate that the MPC performs more intelligently than the RBC in charging thermal energy storage and selecting heat pump sources by taking advantage of the predicted cooling demands of the building and the performance of the integrated system. As a result, the MPC could save energy and reduce operating costs compared with the RBC. A case study shows that, for a 3-day operation, the MPC saves 36.9% energy and reduces 38.5% operating cost compared with the RBC.

Shi, Liang↗