Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Current measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Selecting Charged Current Muon Neutrino Interactions on Argon with the Short-Baseline Near Detector

The uncertainties associated with neutrino-nucleus cross section modelling need to be reduced in order to measure neutrino oscillation parameters, the mass hierarchy and CP violation to a high degree of precision. SBND, a 112 ton liquid argon time projection chamber, will be the near detector of the short-baseline neutrino program at Fermilab. Once data taking begins in 2022, it will provide flux constraints for sterile neutrino searches and produce world leading neutrino-argon cross sections with up to seven million neutrino events in three years. This thesis describes the simulation, calibration and reconstruction tools developed to measure charged current muon neutrino interactions.Backgrounds from cosmic ray muons, neutrino interactions outside of the detector and different neutrino interaction channels were identified and removed as part of this process.The signal events were selected with purity of 90% and an efficiency of 67%, providing a strong starting point for meas urements of exclusive channels. The expected statistical and systematic uncertainties on rate predictions and cross section measurements at the full 6.6×10$^{20}$ proton on target exposure were evaluated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Statistics Measurements of $ν_μ$ Charged-Current Single $π^{+}$ Production with Zero Pion Kinetic Energy Threshold in MINERvA

This Letter presents measurements of single-differential cross sections of $ν_μ$-induced charged-current 1 $π^{+}$ production on scintillator using the MINERvA detector at Fermilab. These measurements use traditional track-based pion reconstruction as well as pions identified solely via Michel electron decays, allowing measurement of kinetic energies from 0 to 350 MeV. In total, 91,843 events were selected with $W_{exp}$$<$ 1.4 GeV/c. Differential cross sections as a function of pion and muon kinematic variables are presented and compared with the predictions of several neutrino event generators. Overall, modern pion production models tend to agree with data at the ends of the kinematic regions probed, but are discrepant with the main regions of the phase space probed by up to 15% in muon observables and up to 20% in pion observables. No model describes any of the variables well, and this result highlights model areas that require improvement for the next generation of neutrino oscillation experiments.

Granados, E. [Guanajuato U.]↗

The Dark Energy Survey Supernova Program: an updated measurement of the Hubble constant using the inverse distance ladder

We measure the current expansion rate of the Universe, Hubble’s constant $H_0$, by calibrating the absolute magnitudes of supernovae to distances measured by baryon acoustic oscillations (BAO). This ‘inverse distance ladder’ technique provides an alternative to calibrating supernovae using nearby absolute distance measurements, replacing the calibration with a high-redshift anchor. We use the recent release of 1829 supernovae from the Dark Energy Survey spanning $0.01\lt z\lt 1.13$ anchored to the recent baryon acoustic oscillation measurements from Dark Energy Spectroscopic Instrument (DESI) spanning $0.30 \lt z_{\mathrm{eff}}\lt 2.33$. To trace cosmology to $z=0$, we use the third-, fourth-, and fifth-order cosmographic models, which, by design, are agnostic about the energy content and expansion history of the universe. With the inclusion of the higher redshift DESI-BAO data, the third-order model is a poor fit to both data sets, with the fourth-order model being preferred by the Akaike Information Criterion. Using the fourth-order cosmographic model, we find $H_0=67.19^{+0.66}_{-0.64}\mathrm{~km} \mathrm{~s}^{-1} \mathrm{~Mpc}^{-1}$, in agreement with the value found by Planck without the need to assume Flat-$\Lambda$CDM. However, the best-fitting expansion history differs from that of Planck, providing continued motivation to investigate these tensions.

79 ASTRONOMY AND ASTROPHYSICS↗

Possible paths for the production of 73 As

Inelastic scattering reactions including (n,2n) are particularly difficult to measure. Hardly any measurements on radioactive nuclei exist. The reason is that traditional methods require the detection of gammas or neutrons in a background of elastically scattered neutrons, which can interact with the detector or other materials. The 73 As(n,2n) and the 73 As(n,2n) reaction cross sections are the only neutron removal cross sections that can be measured with current methods. The corresponding cross sections for the short-lived isotopes 71,72,74 As can only be directly measured in inverse kinematics. Since 75 As is the only stable isotope of this element, the sample production is no problem at all. This report is therefore focused on the sample production for a possible 73 As(n,2n) campaign.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Environmental charging effects monitors for operational satellites

A set of three instruments has been developed that can provide early detection of potentially dangerous geomagnetic substorm conditions, and monitor the spacecraft response. The set consists of three instruments: (1) a 'surface voltage sensor' that measures the characteristic energy of collected electrons or ions from +100 to -20,000 volts; (2) a 'nanoammeter' or logarithmic current density sensor that measures local electron flux by measuring currents from 10 to the -9th to 10 to the -5th A; and (3) a 'transient events counter' that counts the spurious pulses from electrostatic discharges that are coupled into the spacecraft wiring harness. Performance characteristics, specifications, and application of these instruments are discussed.

Sturman, J. C.↗

Evaluation of the Performance Characteristics of CGLSS II and U.S. NLDN Using Ground-Truth Data from Launch Complex 398, Kennedy Space Center, Florida

A new comprehensive lightning instrumentation system has been designed for Launch Complex 39B (LC39B) at the Kennedy Space Center, Florida. This new instrumentation system includes six synchronized high-speed video cameras, current sensors installed on the nine downcouductors of the new lightning protection system (LPS) for LC39B; four dH/dt, 3-axis measurement stations; and five dE/dt stations composed of two antennas each. The LPS received 8 direct lightning strikes (a total of 19 strokes) from March 31 through December 31, 2011. The measured peak currents and locations are compared to those reported by the CGLSS 11 and the NLDN. Results of comparison are presented and analyzed in this paper.

Mata, Carlos T.↗

Evaluation of the Performance Characteristics of CGLSS II and U.S. NLDN Using Ground-Truth Dalta from Launch Complex 398, Kennedy Space Center, Florida

A new comprehensive lightning instrumentation system has been designed for Launch Complex 39B (LC39B) at the Kennedy Space Center, Florida. This new instrumentation system includes seven synchronized high-speed video cameras, current sensors installed on the nine downconductors of the new lightning protection system (LPS) for LC39B; four dH/dt, 3-axis measurement stations; and five dE/dt stations composed of two antennas each. The LPS received 8 direct lightning strikes (a total of 19 strokes) from March 31 through December 31 2011. The measured peak currents and locations are compared to those reported by the Cloud-to-Ground Lightning Surveillance System (CGLSS II) and the National Lightning Detection Network (NLDN). Results of comparison are presented and analyzed in this paper.

Mata, C. T.↗

A decay database of coincident γ–γ and γ–X -ray branching ratios for in-field spectroscopy applications

Current fieldable spectroscopy techniques often use single detector systems heavily impacted by interferences from intense background radiation fields. These effects result in low-confidence measurements that can lead to misinterpretation of the collected spectrum. To help improve interpretation of the fission products and short-lived radionuclides produced in a composite sample, a coincidence-database is being developed in support of a robust portable and X-ray coincidence detector system concurrently under development at the Pacific Northwest National Laboratory for in-field deployment. Hitherto, no database exists containing coincident γ–γ and γ–X-ray branching-ratio intensities on an absolute scale that will greatly enhance isotopic identification for in-field applications. As part of this project, software has been developed to parse all radioactive-decay data sets from the Evaluated Nuclear Structure Data File (ENSDF) archive to enable translation into a more useful JavaScript Object Notation (JSON) formats that more readily supports query-based data manipulation. The coincident database described in this work is the first of its kind and contains coincidence γ–γ and γ–X-ray intensities and their corresponding uncertainties, together with auxiliary metadata associated with each decay data set. The new JSON format provides a convenient and portable means of data storage that can be imported into analysis frameworks with relatively low overhead allowing for meaningful comparison with measured data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutron-diagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

End-to-End Simulations of a 3.4-Meter Detector Wall for Neutron-Diagnosed Subcritical Experiments

The Nevada National Security Site, together with Los Alamos National Laboratory and Lawrence Livermore National Laboratory, is developing a novel diagnostic to measure the reactivity of subcritical experiments. This capability is known as neutron-diagnosed subcritical experiments. The decay of the fission gamma rays from the neutron-interrogated subcritical experiment is measured as a function of time with a large (~3-meter diameter) detector wall consisting of 151 individual detector pixels. The data from this current mode measurement inform the neutron multiplication factor, keff, and thus the relative reactivity of the subcritical experiment. The Nevada National Security Site developed the Gamma Array Simulation Toolkit initially to help inform the design of the individual detector pixels and the 3.4-meter diameter detector wall to be fielded as part of neutron-diagnosed subcritical experiments. This toolkit is now being used to simulate and predict the performance of the final design of the individual detector pixels and the aggregate detector wall. Key detector characteristics evaluated from these simulations include impulse response, pulse height spectrum, number of photoelectrons per MeV, detector efficiency, and cross talk between detector pixels. Collectively, the results of these simulations inform how well the fission gamma ray die-off distribution from a neutron-diagnosed subcritical experiment measurement can be resolved. This is critical to determining the relative reactivity of the experiment. Furthermore, the Gamma Array Simulation Toolkit can be used to aid in the analysis of the experimental data from a neutrondiagnosed subcritical experiment measurement once the simulation has been benchmarked.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Altitude Electromagnetic Pulse Testing of Photovoltaic Modules

This report details the test setup, process, and results for radiated susceptibility testing of multicrystalline silicon photovoltaic (PV) modules as part of the EMP-Resilient Electric Grid Grand Challenge Laboratory Directed Research and Development (LDRD) project at Sandia National Laboratories. Testing was conducted over October 10-17, 2019, where 8 photovoltaic modules were exposed to E1 transient pulses with peak field levels up to 100 kV/m. Modules were terminated in a resistive load representing connected components. State of health testing conducted via I-V curve tracing of the photovoltaic modules showed no observable loss of device function due to large electric field transients. Differential mode currents were measured on the order of 10's of amps for up to a microsecond following the radiated field pulse. Common mode currents took the form of a damped sinusoid with a maximum peak of 10's to 100's of amps with a resonance near 60 MHz.

14 SOLAR ENERGY↗

Small Autonomous Aircraft Servo Health Monitoring

Small air vehicles offer challenging power, weight, and volume constraints when considering implementation of system health monitoring technologies. In order to develop a testbed for monitoring the health and integrity of control surface servos and linkages, the Autonomous Aircraft Servo Health Monitoring system has been designed for small Uninhabited Aerial Vehicle (UAV) platforms to detect problematic behavior from servos and the air craft structures they control, This system will serve to verify the structural integrity of an aircraft's servos and linkages and thereby, through early detection of a problematic situation, minimize the chances of an aircraft accident. Embry-Riddle Aeronautical University's rotary-winged UAV has an Airborne Power management unit that is responsible for regulating, distributing, and monitoring the power supplied to the UAV's avionics. The current sensing technology utilized by the Airborne Power Management system is also the basis for the Servo Health system. The Servo Health system measures the current draw of the servos while the servos are in Motion in order to quantify the servo health. During a preflight check, deviations from a known baseline behavior can be logged and their causes found upon closer inspection of the aircraft. The erratic behavior nay include binding as a result of dirt buildup or backlash caused by looseness in the mechanical linkages. Moreover, the Servo Health system will allow elusive problems to be identified and preventative measures taken to avoid unnecessary hazardous conditions in small autonomous aircraft.

Quintero, Steven↗

Effect of Crystal Defects on Minority Carrier Diffusion Length in 6H SiC Measured Using the Electron Beam Induced Current Method

We report values of minority carrier diffusion length in n-type 6H SiC measured using a planar Electron Beam Induced Current (EBIC) method. Values of hole diffusion length in defect free regions of n-type 6H SiC, with a doping concentration of 1.7El7 1/cu cm, ranged from 1.46 microns to 0.68 microns. We next introduce a novel variation of the planar method used above. This 'planar mapping' technique measured diffusion length along a linescan creating a map of diffusion length versus position. This map is then overlaid onto the EBIC image of the corresponding linescan, allowing direct visualization of the effect of defects on minority carrier diffusion length. Measurements of the above n-type 6H SiC resulted in values of hole diffusion length ranging from 1.2 micron in defect free regions to below 0.1 gm at the center of large defects. In addition, measurements on p-type 6H SiC resulted in electron diffusion lengths ranging from 1.42 micron to 0.8 micron.

Tabib-Azar, Massood↗

Measuring the neutrino-oxygen neutral current quasielastic cross section using the accelerator neutrino neutron interaction experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-doped water Cherenkov detector located on-axis to Fermilab’s Booster Neutrino Beam (BNB). ANNIE is uniquely positioned to perform high-statistics measurements of neutrino-nucleus interactions in water, benefiting from a large neutrino flux due to a short (100-meter) baseline. A central focus of ANNIE’s physics program is the measurement of both charged current (CC) and neutral current (NC) cross sections on water, including neutral current quasielastic (NCQE) and CC-inclusive channels. The NCQE measurement is particularly critical for constraining uncertainties in rare-event searches such as the Diffuse Supernova Neutrino Background (DSNB), where atmospheric $\nu$NCQE interactions constitute a significant and poorly constrained background. This dissertation presents a measurement of the flux-averaged neutrino-oxygen neutral current quasielastic ($\nu$NCQE) cross section using $2.573 \times 10^{20}$~POT of BNB exposure from the 2022 and 2023 beam years. The $\nu$NCQE interaction is identified through the primary $\gamma$-rays produced by nuclear de-excitation of the residual $^{15}$N$^*$ or $^{15}$O$^*$ nucleus following nucleon knockout from $^{16}$O. A dedicated Monte Carlo (MC) re-tuning campaign was conducted using an americium-beryllium (AmBe) calibration source, Michel electrons from stopped muons, and throughgoing dirt muons originating upstream of the detector. This multi-sample approach provided a wide-ranging $\mathcal{O}(\text{MeV})$--$\mathcal{O}(\text{GeV})$ dataset for tuning the simulated detector response, which was subsequently validated against AmBe neutron and Michel electron data for use in the $\nu$NCQE analysis. A dedicated laser calibration campaign was carried out to reduce timing uncertainties across the PMT system, enabling reconstruction of the BNB bunch substructure with sufficient resolution to serve as a background rejection tool. By selecting events in-time with individual neutrino bunches, beam-correlated $\nu$NCQE events are separated from diffuse and accelerator-induced backgrounds, notably skyshine neutrons and externally-originating events, that would otherwise dominate traditional charge-based selections within a small-scale, surface-level, short-baseline detector. A data-driven estimation of the skyshine neutron and external background rates was performed and incorporated into the systematic uncertainty budget. The flux-averaged $\nu$NCQE cross section on oxygen is measured to be $1.57 \pm 0.06\,(\text{stat.})$ $^{+0.91}_{-0.67}\,(\text{syst.})$ $\times 10^{-38}\ \text{cm}^{2}$. A full systematic budget is constructed by propagating uncertainties in the secondary hadronic interaction modeling, background cross section normalizations, detector response, neutrino flux, and the primary $\gamma$-ray emission probabilities from oxygen nuclear de-excitation. An idealized de-excitation model, constructed from existing measurements in the literature is developed to benchmark the predictions of the \textsc{GENIE} event generator. A comparison reveals that \textsc{GENIE} systematically overpredicts the primary $\gamma$-ray emission probability from oxygen de-excitation by a factor of $1.49\times$ for $E_\gamma > 6$~MeV and $3.07\times$ in the $3$--$6$~MeV band. This comparison motivates the dominant systematic uncertainty in this analysis, where a conservative uncertainty of $^{+39.9\%}_{-0\%}$ on the primary $\gamma$-ray signal prediction is assigned. The ANNIE result is consistent with and complementary to existing flux-averaged $\nu$NCQE cross section measurements from T2K and Super-Kamiokande, providing an independent measurement with a different detector, neutrino beam, and analysis methodology. Looking ahead, an upgrade to the ANNIE DAQ infrastructure enabling continuous extended readout will allow a complementary $\nu$NCQE neutron multiplicity measurement, directly relevant to constraining the NCQE background in DSNB searches, competitive with the recent T2K measurement at SK-Gd. The planned Super-SANDI upgrade, deploying a large Water-based Liquid Scintillator (WbLS) volume, will further extend ANNIE's reach to hadronic final states and exclusive NC channels, and enable joint measurements with liquid argon detectors sharing the BNB beamline ahead of DUNE and Hyper-Kamiokande.

Doran, Steven [Iowa State U.]↗

Interaction between heavier ions and ring current protons

The interaction of thermal oxygen or helium ions and ring current protons may produce a wide variety of phenomena in the magnetosphere. These include the production of energetic oxygen ions or energetic helium ions, modification of the bulge region in the afternoon plasmasphere, heating of electrons in the upper ionosphere and production of stable auroral red arcs, precipitation of energetic protons, and precipitation of energetic alpha particles. Large-amplitude waves generated in the interaction may also lead to wave-wave coupling. The theory developed also suggests that heavier ions such as lithium artificially injected into the ring current to remove ring current protons may be heated substantially in the process. Computations of wave growth have been made for the first time by using measured ring current flux and anisotropies.

Brice, N.↗

Electrical meter probe contact verification system

A system and method verifies continuity with and measures voltage across a circuit under test (in some instances simultaneously) using two or more test probes. Two or more probe continuity circuits measure continuity through the test probes by injecting a test current through and measuring a processed test current received at each of the plurality of test probes. The probe continuity circuits measure the respective processed test current rendered by the test current flowing through the test circuit at each test probe. A voltmeter measures the potential difference across the test probes.

42 ENGINEERING↗

Autonomous Method and System for Minimizing the Magnitude of Plasma Discharge Current Oscillations in a Hall Effect Plasma Device

An autonomous method for minimizing the magnitude of plasma discharge current oscillations in a Hall effect plasma device includes iteratively measuring plasma discharge current oscillations of the plasma device and iteratively adjusting the magnet current delivered to the plasma device in response to measured plasma discharge current oscillations to reduce the magnitude of the plasma discharge current oscillations.

Hruby, Vladimir↗

Eddy Current Lift-Off Sensor Model

Eddy current sensors measure the lift-off or distance between the sensor head and a conducting surface. The sensor consists of a conducting coil carrying an alternating electrical current. By Faraday’s Law, a magnetic field is generated within the coil. This field induces electrical current loops within the conducting surface which in turn generate a magnetic field. This induced magnetic field opposes the coil magnetic field and thus, the current in the coil. This reduces the inductance of the coil while increasing its resistance. The strength of the induced magnetic field and consequently the coil inductance are proportional to the lift-off of the coil from the surface. Thus, a measurement of the coil inductance may yield a measure of the lift-off.

42 ENGINEERING↗