Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Critical Fluids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Osmotic control of the spacing of parallel shear cracks in shale growing subcritically in geologic past

The geological genesis of natural cracks in sedimentary rocks such as shale is a problem that needs to be understood to improve the technology of hydraulic fracturing as well as deep sequestration of harmful fluids. Why are the vertical natural cracks roughly parallel and equidistant, and why is the spacing roughly 10 cm rather than 1 cm or 100 cm? Fracture mechanics of critical cracks cannot answer this question. Neither can the material heterogeneity. The growth of critical parallel cracks is impossible because the relative crack face displacements would immediately localize into one crack, leading to an earthquake. The cracks must have formed, on the tectonic time scale, by a slow growth of subcritical shear cracks governed by the Charles-Evans law. The idea advanced here is that what controls the crack spacing is the balance between the reduction, due to shear dilatancy, of the concentration of ions such as Na + and Cl - in each fracture process zone (PFZ), which decelerates the cracks, and the restoration of ion concentration by diffusion of ions from the space between the cracks into the FPZ. This diffusion of water is driven mainly by the osmotic pressure gradient, which offsets the deceleration and depends strongly on the crack spacing. A simple analytical solution of the steady state is rendered possible by approximating the ion concentration profiles between adjacent cracks by parabolic arcs. Applying this theory to Woodford shale yields the approximate crack spacing of 10 cm, which is realistic. Furthermore, the stability of unlimited parallel mode II frictional crack growth is proven by examining the second variation of the free energy. Water concentration drop in the FPZ due to shear dilatancy and its restoration by water diffusion from the inter-crack space have similar effect, although probably much weaker.

42 ENGINEERING↗

Core electron temperature turbulence and transport during sawtooth oscillations in the DIII-D tokamak

Abstract Sawteeth are one of the concerning instabilities in ITER and future burning plasma experiments. Sawtooth dynamics and its interaction with broadband plasma turbulence has been a challenge for predictive simulations of core transport in future fusion devices. This study provides new observations of core turbulence behavior during sawtooth oscillations in DIII-D hydrogen L-mode neutral beam injection heated plasmas in an inner wall limited configuration. A strong correlation of electron temperature and density turbulence levels with the sawtooth oscillation phase has been observed at locations inside the T e inversion radius and/or safety factor q = 1 magnetic surface. The T e turbulence amplitude in the core during the sawtooth ramp exhibits a critical T e gradient behavior inside but not near the T e inversion radius/ q = 1 magnetic surface. The most unstable mode calculated from the trapped gyro-landau fluid turbulence simulations reveal a change from low- k ion-type to low-k electron-type modes from pre- to post- sawtooth crash time periods.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Johnson Space Center CFD overview

Recent applications and development of CFD technology have focused on flow problems that are critically important to the operation and design of space flight vehicles. The main effort is spent on the Space Shuttle in order to provide an understanding of the cryogenic fluid in the duct connecting the External Tank and the Main Engines, the subsonic flow surrounding the Orbiter during crew egress maneuvers, the transonic aerodynamic forces on the Orbiter fuselage and wing, the high angle-of-attack abort flight, and the aerodynamic heating during entry. To provide in-depth analyses for such diverse problems within a timely schedule, matured panel codes and a state-of-the-art incompressible turbulent flow code were adapted. Collaboration with Ames Research Center has resulted in a Shuttle ascent aerodynamic code; and a viscous chemical nonequilibrium code is being developed for predicting Orbiter real-gas aerodynamics and finite-catalytic heating. The remaining activities are devoted to the prediction of the flow environment around the Aeroassist Flight Experiment vehicle at hypersonic speeds and high altitudes. A thermochemical nonequilibrium Navier-Stokes code has been developed on the basis of two- temperature and 11-species models for solving both the shock layer and near wake. After validating the code against wind-tunnel aerodynamic, pressure and heating data, the code is being used to supplement the ground test facilities in predicting a more realistic flight environment. CFD technology is being relied upon by other programs as well in the consideration of candidate configurations.

Li, Chien P.↗

Development of a quiet supersonic wind tunnel with a cryogenic adaptive nozzle

The main objectives of this work is to demonstrate the potential of a cryogenic adaptive nozzle to generate quiet (low disturbance) supersonic flow. A drive system was researched for the Fluid Mechanics Laboratory (FML) Laminar Flow Supersonic Wind Tunnel (LFSWT) using a pilot tunnel. A supportive effort for ongoing Proof of Concept (PoC) research leading to the design of critical components of the LFSWT was maintained. The state-of-the-art in quiet supersonic wind tunnel design was investigated. A supersonic research capability was developed within the FML.

Wolf, Stephen D.↗

Extratropical Weather Systems on Mars: Radiatively-Active Water Ice Effects

Extratropical, large-scale weather disturbances, namely transient, synoptic-period,baroclinic barotropic eddies - or - low- (high-) pressure cyclones (anticyclones), are components fundamental to global circulation patterns for rapidly rotating, differentially heated, shallow atmospheres such as Earth and Mars. Such "wave-like" disturbances that arise via (geophysical) fluid shear instability develop, mature and decay, and travel west-to-east in the middle and high latitudes within terrestrial-like planetary atmospheres. These disturbances serve as critical agents in the transport of heat and momentum between low and high latitudes of the planet. Moreover, they transport trace species within the atmosphere (e.g., water vapor/ice, other aerosols (dust), chemical species, etc). Between early autumn through early spring, middle and high latitudes on Mars exhibit strong equator-to-pole mean temperature contrasts (i.e., "baroclinicity"). Data collected during the Viking era and observations from both the Mars Global Surveyor (MGS) and Mars Reconnaissance Orbiter (MRO) indicate that such strong baroclinicity supports vigorous, large-scale eastward traveling weather systems [Banfield et al., 2004; Barnes et al., 1993]. A good example of traveling weather systems, frontal wave activity and sequestered dust activity from MGS/MOC image analyses is provided in Figure 1 (cf. Wang et al. [2005]). Utilizing an upgraded and evolving version of the NASA Ames Research Center (ARC) Mars global climate model, investigated here are key dynamical and physical aspects of simulated northern hemisphere (NH) large-scale extratropica lweather systems,with and without radiatively-active water ice clouds. Mars Climate Model:

cyclones↗

DYNAMX: A Low Temperature Microgravity Investigation of Phase Transitions

The Critical Dynamics in Microgravity Experiment, DYNAMX, will investigate the effects on the superfluid transition in 4 He of currents generated by heat flow, measuring the thermal conductivity in the fluid as a function of applied heat. DYNAMX will also take advantage of the weightless environment to measure the conductivity properties in the region of the interface between the two phases. Thus, DYNAMX represents an experiment that will explore a system driven far from equilibrium. This paper will describe the science objectives, the current design of the experiment apparatus, the steps being taken to prepare this experiment for flight, and the results of ground-based feasibility demonstrations now underway.

superfluid↗

Recent Ground-based Test Results for the Closed Loop Two-Phase Flow Chilldown Test Module for Future Integration with the Flow Boiling and Condensation Experiment onboard International Space Station

Effective cryogenic fluid management is important to the success of future manned and unmanned NASA missions, and the transfer line chilldown process is recognized as a key technological challenge. To address this challenge, the Two-phase Flow and Thermal Management Lab (TFTML) at Case Western Reserve University is collaborating with NASA Glenn Research Center to develop, test and deploy a closed loop two-phase flow chilldown test section onboard the International Space Station to be integrated with the current Flow Boiling and Condensation Experiment (FBCE) module. The final results of this project will create the first chilldown process database under pure and sustained microgravity conditions and will significantly advance the understanding of the chilldown process for cryogenic fluid management. In the present work, the ground-based test results of the closed loop SS-316 chilldown test section in a horizontal configuration at varying inlet mass flow rates (3-40 g/s) and inlet liquid subcooling (5-35 0C) are presented. The working fluid is PF-5060 and the chilldown curves captured the entire quenching curve involving the different boiling regimes and temperature transition points viz., film boiling, Leidenfrost/re-wetting point, transition boiling, critical heat flux (CHF), nucleate boiling, onset of nucleate boiling (ONB) and single-phase liquid flow regions, when the test section is pre-heated to around 250 0C. The major findings of the present study are, (i) the bottom part of the test section sees a lower re-wetting temperature due to the horizontal flow configuration, (ii) the re-wetting temperatures are relatively unaffected by inlet liquid mass flow rates though the increase in mass flow rates reduce the chilldown time, and (iii) the re-wetting temperatures decrease with decrease in inlet liquid subcooling. Further, preliminary flow visualization studies in a transparent pyrex test section will also be presented to understand the intricate flow boiling regime transitions during the chilldown process.

ISS↗

Validation of Accurate Cryogenic Fluid Vapor-Liquid Boundary Conditions Via Molecular Simulations

Vapor-liquid interfaces drive many important phenomena in cryogenic fluid management, including heat transfer, evaporation, and capillary flow. Design of cryogenic fluid systems, such as propellant storage, requires accurate predictions of fluid behavior, including evaporation rates. Many models have been proposed for heat and mass transfer at vapor liquid interfaces, but the accuracy of these models in the context of cryogenic fluids has not been performed. We use molecular dynamics simulations, which allow for nanometer scale resolution of fluid phenomena, to evaluate the accuracy of a variety of vapor-liquid boundary conditions at evaporating and condensing interfaces. We find that an anisotropic temperature distribution is a critical ingredient for accurate prediction of intensive evaporation and condensation.

Daniel Vigil↗

Representation and display of vector field topology in fluid flow data sets

The visualization of physical processes in general and of vector fields in particular is discussed. An approach to visualizing flow topology that is based on the physics and mathematics underlying the physical phenomenon is presented. It involves determining critical points in the flow where the velocity vector vanishes. The critical points, connected by principal lines or planes, determine the topology of the flow. The complexity of the data is reduced without sacrificing the quantitative nature of the data set. By reducing the original vector field to a set of critical points and their connections, a representation of the topology of a two-dimensional vector field that is much smaller than the original data set but retains with full precision the information pertinent to the flow topology is obtained. This representation can be displayed as a set of points and tangent curves or as a graph. Analysis (including algorithms), display, interaction, and implementation aspects are discussed.

Helman, James↗

Modelica-based modeling and simulation of district cooling systems: A case study

While equation-based object-oriented modeling language Modelica can evaluate practical energy improvements for district cooling systems, few have adopted Modelica for this type of large-scale thermo-fluid system. Further, to our best knowledge, district cooling modeling studies have yet to include hydraulics in piping networks alongside plant models featuring realistic mechanical systems and controls. These are critical details to include when looking to make energy and control improvements in many physical system installations. To fill these gaps, this study released new open-source district cooling models at the Modelica Buildings Library and leveraged these models for a real-world case study at the University of Colorado Boulder. Here, the site includes six buildings connected to a central chiller plant featuring a waterside economizer. Several energy saving strategies are pursued based on the validated model, including control setpoint optimization, equipment modification, and pump setpoint adjustments. Results indicate that a combination of the studied measures can save the campus annually 84.6 MWh of energy, 8.9% of electricity costs, 58.0 metric tons of carbon dioxide emissions, while the waterside economizer cuts down chillers’ run times by 201 days/year, reducing maintenance costs and extending chiller life.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploiting Synergies Between Lensing and BAO Surveys for Improved Cosmological Constraints

Pinning down the nature of dark energy is one of the most pressing questions in modern physics and is one of the five key science drivers identified in the P5 report [P514]. Dark energy is thought to be either a cosmological constant with an equation of state w = P/ρ = −1 which remains constant at all times, a new type of fluid with an equation of state that varies with time (w ̸= constant), or dark energy might indicate a breakdown of Einstein’s Theory of General Relativity (GR). It is of critical importance to distinguish between these three scenarios. This can only be accomplished by ambitious and demanding measurements of both the expansion rate of the universe (to track the time evolution of dark energy) together with measurements of the rate at which cosmic structures, such as galaxies and clusters of galaxies, grow with time (the “growth rate”). Because of the challenging nature of such observations, and because no single probe simultaneously measures both expansion and growth, the Dark Energy Task Force [A+06] emphasized the importance of using multiple distinct methods to characterize dark energy.

79 ASTRONOMY AND ASTROPHYSICS↗

Spin waves in fluids

A working report is presented in order to document early results of research on the stability of laminar boundary layers. The report shows that constitutive equations for a structured continua may be derived by the technique of reinterpreting velocity in the conventional stress to rate-of-strain relationship so as to account for effects of particle rotation. It is demonstrated that accounting for particle structure even at a molecular level makes the fluid viscoelastic with the ability to propagate vector waves. It is shown that particle structure modifies the basic stability equation for the system, which in turn would alter values for critical Reynolds number.

Kistler, E. L.↗

Design and fabrication of the Mini-Brayton Recuperator (MBR)

Development of a recuperator for a 2.0 kW closed Brayton space power system is described. The plate-fin heat exchanger is fabricated entirely from Hastelloy X and is designed for 10 years continuous operation at 1000 K (1300 F) with a Xenon-helium working fluid. Special design provisions assure uniform flow distribution, crucial for meeting 0.975 temperature effectiveness. Low-cycle fatigue, resulting from repeated startup and shutdown cycles, was identified as the most critical structural design problem. It is predicted that the unit has a minimum fatigue life of 220 cycles. This is in excess of the BIPS requirement of 100 cycles. Heat transfer performance and thermal cycle testing with air, using a prototype unit, verified that all design objectives can be met.

Killackey, J. J.↗

Low-gravity experiments in critical phenomena

Studies of anomalous thermodynamic, transport, and structural phenomena in multibody systems near critical points are reviewed. The nomenclature used to describe critical points is explained; theoretical predictions of the thermodynamic properties of bulk systems are presented; and experimental tests of these predictions systems are discussed, considering equilibration and gravity effects in fluid systems and emphasizing the value of experiments conducted in a reduced-gravity environment. Several such experiments are described, and the available academic-research opportunities are briefly surveyed.

Moldover, Michael R.↗

Geoid and topography for infinite Prandtl number convection in a spherical shell

Geoid anomalies and surface and lower-boundary topographies are calculated for numerically generated thermal convection for an infinite Prandtl number, Boussinesq, axisymmetric spherical fluid shell with constant gravity and viscosity, for heating both entirely from below and entirely from within. Convection solutions are obtained for Rayleigh numbers Ra up to 20 times the critical Ra in heating from below and 27 times critical for heating from within. Geoid parallels surface undulations, and boundary deformation generally increases with increasing cell wavelength. Dimensionless geoid and topography in heating from below are about 5 times greater than in heating from within. Values for heating from within correlate more closely with geophysical data than values from heating from below, suggesting a predominance of internal heating in the mantle. The study emphasizes that dynamically induced topography and geoid are sensitive to the mode of heating in the earth's mantle.

Bercovici, D.↗

Fast Fourier Transform algorithm design and tradeoffs

The Fast Fourier Transform (FFT) is a mainstay of certain numerical techniques for solving fluid dynamics problems. The Connection Machine CM-2 is the target for an investigation into the design of multidimensional Single Instruction Stream/Multiple Data (SIMD) parallel FFT algorithms for high performance. Critical algorithm design issues are discussed, necessary machine performance measurements are identified and made, and the performance of the developed FFT programs are measured. Fast Fourier Transform programs are compared to the currently best Cray-2 FFT program.

Kamin, Ray A., III↗

Countermeasures to microgravity

Biological systems ranging from the most simple to the most complex generally survive exposure to microgravity. Changes in many characteristics of biological systems are well documented as a consequence of space flight. Attempts to devise countermeasures to microgravity may have direct pragmatic consequences for crew protection and may provide additional insights into the nature of microgravity influences on biological systems. Some of the most well documented changes occur in humans who have experienced space flight. Changes appear to be transient. Space adaption syndrome occurs relatively briefly whereas bone deterioration may require months of postflight time for restoration. It seems critical to recognize that these changes and others may derive from rather passive, active or even reactive changes in the biological systems that are hosts to them. For example, hydrostatic fluid redistributions may be quite passive occurrences that are realized through extensive fluid channels. Changes occur in cell metabolism because of fluid, nutrient and gas redistributions. Equally important are the misconstrued messages likely to be carried by fluid redistributions. These reactive events can trigger, for example, loss of fluids and electrolytes through altered kidney function. Each of these considerations must be evaluated in regard to the biological site affected. Countermeasures to the vast range of biological changes and sites are difficult to envision. The most obvious countermeasure is the restoration of gravity-like influences. Some options are discussed. Recent work has focussed on the use of magnetic fields. Pulsed electromagnetic fields (PEMF) are shown to alleviate bone deterioration produced in rodents exposed to tail suspension. Methods of PEMF exposure are consistent with human use in space. Related methods may provide muscular and neural benefits.

Luttges, Marvin W.↗

Damage-mitigating control of a reusable rocket engine for high performance and extended life

The goal of damage mitigating control in reusable rocket engines is to achieve high performance with increased durability of mechanical structures such that functional lives of the critical components are increased. The major benefit is an increase in structural durability with no significant loss of performance. This report investigates the feasibility of damage mitigating control of reusable rocket engines. Phenomenological models of creep and thermo-mechanical fatigue damage have been formulated in the state-variable setting such that these models can be combined with the plant model of a reusable rocket engine, such as the Space Shuttle Main Engine (SSME), for synthesizing an optimal control policy. Specifically, a creep damage model of the main thrust chamber wall is analytically derived based on the theories of sandwich beam and viscoplasticity. This model characterizes progressive bulging-out and incremental thinning of the coolant channel ligament leading to its eventual failure by tensile rupture. The objective is to generate a closed form solution of the wall thin-out phenomenon in real time where the ligament geometry is continuously updated to account for the resulting deformation. The results are in agreement with those obtained from the finite element analyses and experimental observation for both Oxygen Free High Conductivity (OFHC) copper and a copper-zerconium-silver alloy called NARloy-Z. Due to its computational efficiency, this damage model is suitable for on-line applications of life prediction and damage mitigating control, and also permits parametric studies for off-line synthesis of damage mitigating control systems. The results are presented to demonstrate the potential of life extension of reusable rocket engines via damage mitigating control. The control system has also been simulated on a testbed to observe how the damage at different critical points can be traded off without any significant loss of engine performance. The research work reported here is built upon concepts derived from the disciplines of Controls, Thermo-fluids, Structures, and Materials. The concept of damage mitigation, as presented in this report, is not restricted to control of rocket engines. It can be applied to any system where structural durability is an important issue.

Ray, Asok↗