Chlorine Worth Study in Support of PF-4 Operations [Slides]

Aqueous Chloride Operations at PF-4 are important because they recover Pu from other processes, reduce waste sent to WIPP, and increase throughput for Am production. Aqueous Chloride Operations have very conservative mass limits (~520 grams Pu) and significant amounts of Chlorine but calculations not crediting Cl-35 neutron absorption accounting for Cl-35 absorption leads to higher mass limits. Can experiments be designed/conducted to provide technical justification to NCS in order to increase mass limits?

2019 ARCHIMEDES LDRD project↗

IER 557: Godiva IV Reproducibility/Characterization [Slides]

The primary goal of the IER 557 Godiva IV reproducibility/characterization process is to determine reproducibility for 70°C bursts. The secondary goal is to characterize the radiation field, including absolute calibration with radchem counting of fission foils.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Verification of Revised and Upcoming Nuclear Data Sensitivity MCNP Features [Poster]

Nuclear data is ubiquitous across nuclear applications. Improved nuclear data means more accurate simulations. Past focus on k eff caused compensating error and areas of unvalidated nuclear data. Sensitivity can be used to optimize experiments to focus on specific areas. Sensitivity capabilities must be expanded and improved to design multivariate experiments focused on nuclear data needs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deterministic and Monte Carlo Nuclear Data Adjustment Methods [Slides]

For the Bayesian Monte Carlo methodology, a need to understand convergence of the posterior moments as a function of the number of parameter realizations is required. In high-dimensional systems, it can be very costly to sample entire parameter space and perform functional evaluation for every realization. Bayesian Monte Carlo allows one to relax the GLLS approximations of model linearity and prior/posterior PDF shape. The Bayesian Stochastic Collocation Method is a deterministic approach to “sample” the parameter space. It allows one to relax the GLLS approximations of model linearity and posterior PDF shape. Higher-order posterior moments (i.e., skewness, kurtosis, etc.) can be studied through polynomial expansion. Tensor product quadrature scales poorly and can use sparse grid quadrature methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER 501: Pulsed Neutron Die-Away Experiments at LLNL [Slides]

Pulsed neutron die away experiments occur as follows: (1) a pulse of neutrons is injected into a target material via a D-T neutron generator, (2) neutrons thermalize, (3) neutrons spatially equilibrate, and (4) exponential decay is measured in fundamental mode.

43 PARTICLE ACCELERATORS↗

Temperature Dependent Experiments using SPRF/CX [Slides]

A range of fuel arrays has been examined for both fuel types and representative arrays were selected. Temperature dependent calculations were performed to show the performance of the arrays. Modification to the SPRF/CX facility has been proposed to aid SNL staff in the execution of temperature dependent experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Chlorine Worth Study in Support of PF-4 Operations [Slides]

The primary concern of this study is if experiments can be designed/conducted to provide technical justification to NCS in order to increase mass limits. This goal is in direct support of 30 pits per year mission, one of the top priorities for NNSA. The accelerated timeline is as follows: Initial tasking, June 2020; preliminary design completion (CED-1 equivalent), November 2020; final design completion (CED-2 equivalent), March 2021; part receipt and inspection completion (CED-3a equivalent), October 2021; experiment execution (CED-3b equivalent), December 2021; experiment documentation write-up completion (start CED-4a equivalent), January 2022; and ICSBEP target (CED-4a equivalent), Fall 2022.

2019 ARCHIMEDES LDRD project↗

Data Assimilation using Non-invasive Monte Carlo Sensitivity Analysis of Reactor Kinetics Parameters [Slides]

Sensitivity coefficients of prompt neutron decay constant (α) and effective delayed neutron fraction (β eff ) to Pu-239 nuclear data were calculated using a newly available tool (ACEtk). Uncertainty calculations showed the following trends: (1) The prompt neutron decay constant can be used to reduce nuclear data-induced uncertainty in Pu-239(n,f) and (2) the effective delayed neutron fraction can be used to effectively reduce nuclear data-induced uncertainty in Pu-239 total fission $\tilde{v}$. Sensitivity/uncertainty analysis can be used to determine optimal experiment/detector setup to identify compensating errors in nuclear data. Upcoming work includes investigating other nuclide-reaction pairs and response sensitivities, such as Δ$\rho$, neutron leakage spectra, and reaction rate measurements to constrain nuclear data of interest.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FAUST - Benchmark and Validation Framework [Slides]

This presentation discusses Python packages for nuclear data applications and for benchmarking. It also discusses the goals and objectives for FAUST which include providing input and output processing for different calculation codes, allowing for exchanging results between different applications and codes, running benchmarks and processing the results, automating and simplify plot and report generation, and providing a basis for developing applications useful for nuclear data evaluators. The presentation also discusses how the packages can be used both inside and outside LANL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron Pulsed Die-Away Experiments at LLNL [Slides]

This presentation discusses why PNDA is ideal for TSL validations as it does not require fissile material, it has very simple target shapes and compositions, it is only sensitive to absorption and scattering of target medium, and that well conducted experiments have uncertainties of 0.1% - 0.5%. The presentation concludes by examining PNDA’s advantages and its role in nuclear data validations as it offers a cost-effective experiment for an integral benchmark, it provides the ability to focus on specific cross section data validation including thermal neutron absorption and thermal scattering laws, and the low experimental uncertainty makes it an excellent benchmark candidate. Additionally, it is easily tunable and can facilitate temperature dependent cross section validation by cooling or heating up targets.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Oak Ridge Subcritical Assembly Final Design and Current Progress [Slides]

This presentation shows how ORSA design has moved from conceptual to implementable. Additionally, that the ORSA hands-on experiments will remain subcritical under normal and credible abnormal conditions it is fully assembled k eff = 0.95024 ± 0.0003 and USL = 0.9763. This presentation finds locations will have minimal security and safety basis impact. Available options can meet security criteria for ORSA material and Options will have less mass than the ANS-8.1 single parameter limit for 235 U either by segregation or functioning as its own facility. Further, Locations are feasible for a diversity of students and the implementation of ORSA will improve upon NCSP T&E’s vision to remain adaptable and responsive.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Current Progress of the Final Design of a Subcritical Assembly at Oak Ridge National Laboratory [Slides]

This presentation shows how ORSA design has moved from conceptual to implementable. Additionally, that the ORSA hands-on experiments will remain subcritical under normal and credible abnormal conditions it is fully assembled k eff = 0.95024 ± 0.0003 and USL = 0.9763. This presentation finds locations will have minimal security and safety basis impact. Available options can meet security criteria for ORSA material and Options will have less mass than the ANS-8.1 single parameter limit for 235 U either by segregation or functioning as its own facility. Further, Locations are feasible for a diversity of students and the implementation of ORSA will improve upon NCSP T&E’s vision to remain adaptable and responsive.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quasi-Differential Neutron Scattering Measurements of 181 Ta and Teflon from 1.5 to 20 MeV [Slides]

This presentation covers motivation for the Experiments Performed. Secondly, it touches on upgrades to the Experimental Apparatus for Measurements. Thirdly, it presents quasi-Differential Experimental Methodology a) Pulse Shape Discrimination b) Validation Measurement of Carbon. The presentation concludes with Preliminary Results and Future Studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗