Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Performance of tandem-bladed transonic compressor rotor with tip speed of 1375 feet per second

The design and experimental performance of a 20-inch diameter tandem-bladed axial-flow transonic compressor rotor is presented. Radial surveys were made of the flow conditions. At design speed the peak efficiency was 0.88 and occurred at an equivalent weight flow of 63 pounds per second. At peak efficiency the total pressure and total temperature ratios were 1.77 and 1.20, respectively. The stall margin at design speed was 10 percent based on weight flows and total pressure ratios at peak efficiency and near stall.

Urasek, D. C.↗

Performance of 1380-foot-per-second tip-speed axial-flow compressor rotor with blade tip solidity of 1.1

The aerodynamic design parameters are presented along with the overall and blade element performance, of an axial-flow compressor rotor designed to study the effects of blade solidity on efficiency and stall margin. At design speed the peak efficiency was 0.853 and occured at an equivalent weight flow of 65.7lb/sec. The total pressure ratio was 1.68. Design efficiency, weight flow, pressure ratio, and temperature ratio were 0.822, 65.3, 1.65, and 1.187, respectively. Stall margin for design speed was 14 percent based on the weight flows and pressure ratios at peak efficiency and just prior to stall.

Janetzke, D. C.↗

Performance of a 1380-foot-per-second-tip-speed axial-flow compressor rotor with a blade tip solidity of 1.3

Aerodynamic design parameters are presented along the overall and blade element performance, of an axial flow compressor rotor designed to study the effects of blade solidity on efficiency and stall margin. At design speed the peak efficiency was 0.844 and occurred at an equivalent weight flow of 63.5 lb/sec with a total pressure ratio of 1.801. Design efficiency, pressure ratio, and weight flow 0.814, 1.65, and 65.3(41.1 lb/sec/sq ft of annulus area), respectively. Stall margin for design speed was 6.4 percent based on the weight flow and pressure ratio values at peak efficiency and just prior to stall.

Hager, R. D.↗

Single-stage experimental evaluation of compressor blading with slots and vortex generators, part 5

An experimental investigation was conducted to determine the extent that slots and vortex generators can increase the efficiency and stable operating range of highly loaded compressor stages. With slots in the rotor and stator, the stage performance both with and without vortex generators was inferior to that achieved with the unslotted blading. However, with vortex generators, stator slots, and an unslotted rotor, the stable operating range increased 25% and the stage peak efficiency increased 2.1% over the values achieved with the unslotted rotor and stator without vortex generators, at design equivalent rotor speed.

Brent, J. A.↗

Single-stage evaluation of highly-loaded high-Mach-number compressor stages 5. Data and performance of baseline, corner-blow wall suction and combined corner blow wall suction stator

A single-stage compressor with a rotor tip speed of 1600 ft/sec and a 0.5 hub tip ratio was used to investigate the effects of several stator endwall treatment methods on stage range and performance. These endwall treatment methods consisted of stator corner-blow, annular wall suction upstream of stator leading edge, and combined corner-blow and annular wall suction. The overall stage performance with corner blow was essentially the same as the baseline performance. The performance for the annular wall suction and the combined corner-blow and wall suction showed a reduction in peak efficiency of 2.5 percentage points compared to the baseline data.

Nikkanen, J. P.↗

The role of fluctuating forces in the generation of compressor noise

The results of a theoretical and experimental study on the role of aerodynamically-induced fluctuating forces in the sound generation by axial-flow compressors are presented. Analytical models for the generation and radiation of sound by rotor/stator combinations were developed. For the experimental substantiation of the analytical results, the technology was developed to measure fluctuating forces directly on rotating airfoils using miniature differential-pressure sensors and FM telemetry. Under the assumption of full coherence of the force field on the blade, radiated sound power was predicted from the force measurements on blades and compared with measured sound power. Both broadband radiation from a single rotating airfoil and discrete frequency radiation due to interaction of multi-bladed stator/rotor configurations were investigated. The results indicate the necessity to obtain information on the details of the force field for accurate prediction of the radiated sound spectrum.

Heller, H. H.↗

Nonuniform flow field generation for supersonic compressor stator development: Design and preliminary results

Design and preliminary results are given for a technique which can generate a nonuniform flow similar to the discharge of an impulse supersonic compressor rotor. The technique utilizes a carefully contoured, two-dimensional blunt body in a conventional hypersonic wind tunnel to generate the required flow field. To show the effects of the flow vorticity, a cascade of impulse-type blades was tested in this test stream. Some preliminary performance data are given along with comparison with previously determined uniform flow results.

Lipfert, F. W.↗

An investigation of compressor noise by use of a spinning mode synthesizer.

Use of the Spinning Mode Synthesizer (SMS) as a tool for studying the properties of such complex waves as those generated by fan engines. This has greatly reduced the amount of trial and error techniques used for optimizing duct liners. The SMS was designed by using simple transducer theory and properly controlling the phasing to each of 8 loudspeakers. It provides a means for making in-duct measurements of the radial, axial, and circumferential modal distributions. Results are presented which show that the device is of value for investigation of the highly complex nature of compressor radiated noise.

Oslac, M. J.↗

Gated compressor, distortionless signal limiter

Comparator/multiplier arrangement is capable of limiting input power to voice coil so that desired maximum current level is never exceeded. Overall test system consists of signal source which produces frequency spectrum required for acoustic test, gated compressor circuit, and power amplifier feeding transducer.

Woodbury, R. C.↗

Performance of a single-stage transonic compressor with a blade-tip solidity of 1.3

The design and experimental performance of a 50-centimeter-diameter, single stage, axial flow, transonic compressor with a blade tip solidity of 1.3 are presented. Radial surveys were made of the flow conditions for both the rotor and stator. At design speed, peak efficiencies for both rotor and stage were 0.87 and 0.82, respectively, and occurred at an equivalent weight flow of 29.6 kilograms per second (202 kg/sec/sq m of annulus area). At peak efficiency, the total pressure ratios for both rotor and stage were 1.79 and 1.73, respectively. Stall margin for the stage was 17 percent.

Urasek, D. C.↗

Single-stage experimental evaluation of tandem-airfoil rotor and stator blading for compressors. Part 5: Analysis and design of stages D and E

A conventional and a tandem bladed stage were designed for a comparative experimental evaluation in a 0.8 hub/tip ratio single-stage compressor. Based on a preliminary design study, a radially constant work input distribution was selected for the rotor designs. Velocity diagrams and blade leading and trailing edge angles selected for the conventional rotor and stator were used in the design of the tandem blading. The effects of axial velocity ratio and secondary flow on turning were included in the selection of blade leading and trailing edge angles. Design values of rotor tip velocity and stage pressure ratio were 757 ft/sec and 1.26, respectively.

Brent, J. A.↗

High loading, 1800 ft/sec tip speed, transonic compressor fan stage. 2: Final report

Tests were conducted on a 0.5 hub/tip ratio, single-stage fan-compressor designed to produce a pressure ratio of 2.285 an efficiency of 84 percent with a rotor tip speed of 1800 feet per second. A peak efficiency of 82 percent was achieved by the stage at a stall margin of 6.5 percent. Tests showed that stall-limit line was slightly sensitive to tip-radial distortion, but stall-line improvements were noted when the stage was subjected to circumferential and hub-radial flow distortions. Rotor blade passage and trailing edge shock positions were inferred from static pressure contours over the rotor tips.

Morris, A. L.↗

Performance of a single-stage axial-flow transonic compressor stage with a blade tip solidity of 1.7

The overall and blade-element performance of a transonic compressor stage is presented over the stable operating range at rotative speeds from 50 to 100 percent of design speed. Stage peak efficiency of 0.784 was obtained at a weight flow of 28.6 kilograms per second and a pressure ratio of 1.706. Stall margin at design speed was 11.4 percent. The peak efficiency being significantly less than design efficiency was attributed to: (1) the stator loss and the radial gradient of losses being much higher than design, (2) the losses and blockages associated with the rotor part-span dampers not being incorporated into the design, and (3) mismatch of the rotor and stator badle elements.

Moore, R. D.↗

Design and flight testing of a nullable compressor face rake

A compressor face rake with an internal valve arrangement to permit nulling was designed, constructed, and tested in the laboratory and in flight at the NASA Flight Research Center. When actuated by the pilot in flight, the nullable rake allowed the transducer zero shifts to be determined and then subsequently removed during data reduction. Design details, the fabrication technique, the principle of operation, brief descriptions of associated digital zero-correction programs and the qualification tests, and test results are included. Sample flight data show that the zero shifts were large and unpredictable but could be measured in flight with the rake. The rake functioned reliably and as expected during 25 hours of operation under flight environmental conditions and temperatures from 230 K (-46 F) to greater than 430 K (314 F). The rake was nulled approximately 1000 times. The in-flight zero-shift measurement technique, as well as the rake design, was successful and should be useful in future applications, particularly where accurate measurements of both steady-state and dynamic pressures are required under adverse environmental conditions.

Holzman, J. K.↗

Analytical study on a two-dimensional plane of the off-design flow properties of tandem-bladed compressor stators

The flow characteristics of several tandem bladed compressor stators were analytically evaluated over a range of inlet incidence angles. The ratios of rear-segment to front-segment chord and camber were varied. Results were also compared to the analytical performance of a reference solid blade section. All tandem blade sections exhibited lower calculated losses than the solid stator. But no one geometric configuration exhibited clearly superior characteristics. The front segment accepts the major effect of overall incidence angle change. Rear- to front-segment camber ratios of 4 and greater appeared to be limited by boundary-layer separation from the pressure surface of the rear segment.

Sanger, N. L.↗

Overall and blade-element performance of a transonic compressor stage with multiple-circular-arc blades at tip speed of 419 meters per second

A 50-centimeter-diameter axial-flow transonic compressor stage with multiple-circular-arc blades was designed and tested to study the effects of blade shape on efficiency and stall margin. At design speed, peak efficiency of 0.80 occurred at an equivalent weight flow of 29.0 kilograms per second. Measured total pressure ratio and total temperature ratio at peak efficiency were 1.69 and 1.20, respectively. The stall margin at design speed and an equivalent weight flow of 29.0 kilograms per second was 9 percent. The measured stall margin at design weight flow and speed was 15 percent. A comparison of rotor performance made with and without the stator showed a decrease in pressure ratio, peak efficiency, and maximum weight flow with the addition of the stator.

Kovich, G.↗

Backswept impeller and vane island diffuser and shroud for NASA advanced-concepts compressor test rig

A centrifugal impeller based on an existing backswept design was defined. In addition, a vaned diffuser was designed to match this impeller and also to be compatible with an existing 6:1 compressor test rig. The mechanical integrity of this design was verified by analysis. Hardware was procured and inspected to insure conformity with design tolerances. An overspeed test was successfully conducted on one of the impellers fabricated under this program.

Perrone, G. L.↗

Overall and blade-element performance of a multiple-circular-arc bladed transonic compressor rotor with tip speed of 1375 feet per second

The design and experimental performance of a 20-inch-diameter multiple-circular-arc bladed axial-flow transonic compressor rotor is presented. Radial surveys of the flow conditions were made. At design speed the peak efficiency was 0.882 and occurred at a weight flow of 64.0 pounds per second. At this point the total-pressure and total-temperature ratios were 1.79 and 1.205, respectively. The stall margin at design speed was 8 percent based on weight flows and total-pressure ratios at experimental peak efficiency and near stall. The measured stall margin was 20 percent at design weight flow and speed.

Kovich, G.↗