Radiative cooling textiles using industry-standard particle-free nonporous micro-structured fibers

Abstract Thermal radiation is a major dissipative pathway for heat generated by the human body and offers a significant thermoregulation mechanism over a wide range of conditions. We could use this in garment design to enhance personal cooling, which can improve the wearing comfort of garments or even result in energy savings in buildings. At present, however, radiative cooling has received insufficient attention in commercial design and production of textiles for wearable garments. Textiles that efficiently transmit the radiative heat were recently demonstrated, but either do not utilize standard weaving and knitting processes for wearable garments or require substantial process modifications. Here, we demonstrate the design and implementation of large-scale radiative cooling textiles for localized cooling management and enhanced thermal comfort using industry-standard particle-free nonporous micro-structured fibers that are fully compatible with standard textile materials and production methods. The micro-structured fibers, yarns and fabrics are part of a hierarchical photonic structure design that renders the textiles highly infrared transparent (up to > 0.8) while assuring visual opacity (up to 0.99). We design radiative cooling textiles with first-principles electromagnetic methods and fabricate them using commercial textile materials and formation facilities. Our “fabless” approach is confirmed by very good quantitative agreement between design and measurements. The resulting fabrics exhibit wearability properties expected of wearable textiles, and lower skin temperature by ≥ 3 °C compared to conventional textiles, which offers the potential for > 30 % energy savings in buildings and increases wearing comfort by significantly reducing the reliance on latent heat dissipation for thermoregulation.

Catrysse, Peter B.↗

Development and Implementation of Fault-Correction Algorithms in Fault Detection and Diagnostics Tools

A fault detection and diagnostics (FDD) tool is a type of energy management and information system that continuously identifies the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and the application of automated analytics. Building operators on the leading edge of technology adoption use FDD tools to enable median whole-building portfolio savings of 8%. Although FDD tools can inform operators of operational faults, currently an action is always required to correct the faults to generate energy savings. A subset of faults, however, such as biased sensors, can be addressed automatically, eliminating the need for staff intervention. Automating this fault “correction” can significantly increase the savings generated by FDD tools and reduce the reliance on human intervention. Doing so is expected to advance the usability and technical and economic performance of FDD technologies. This paper presents the development of nine innovative fault auto-correction algorithms for Heating, Ventilation, and Air Conditioning pi(HVAC) systems. When the auto-correction routine is triggered, it overwrites control setpoints or other variables to implement the intended changes. It also discusses the implementation of the auto-correction algorithms in commercial FDD software products, the integration of these strategies with building automation systems and their preliminary testing.

field testing↗

ORNL Campus Sustainability and Decarbonization using Waste Heat Recovery from the Oak Ridge Leadership Computing Facility’s High-Performance Computing Data Center

Heat pumps are a clean and efficient technology that can be powered by renewable electricity to transfer heat using a refrigerant from one place to another by different heat sources, making buildings clean and environmentally friendly. With the support of the ORNL Laboratory Modernization Division, this project explored and evaluated an innovative solution that uses water-water cost-effective midtemperature heat pump (MTHP) technology to leverage the low-grade waste heat from ORNL Frontier and the data center to deliver 85°C hot water, which replaces hot steam generated using natural gas combustion boilers for water heating or space heating in the buildings of ORNL campus. Two scenarios were studied. In the first scenario, which considered the 5600-5700-5800 complex only, Carrier’s commercial 1,000 kW MTHP technology achieves more than 6,640 MWh/year energy savings, an emission reduction of 858 TCO2e/year CO2, and a payback time of 4.85 years. In the second scenario, which considered the 5600-5700-5800 complex and Buildings 5100, 5200, and 5300, the CO2 emission reduction is 1,483 TCO2e/year, the operating cost savings are $0.21 million annually, and the payback time is 3.74 years. Additionally, a comprehensive HP ShowCase Tool was developed for evaluating the optimal solution to improve sustainability and decarbonization of the buildings on the ORNL campus. The tool is an Excel-based tool integrated with VBA (Visual Basic for Applications) coding. The tool includes collected ORNL campus building information and an MTHP library, which comprises collected commercial and ORNL-defined MTHPs. The tool was used to evaluate the sustainability and decarbonization of the ORNL campus. The tool can be widely used or referenced for heat pump solutions and building decarbonization renovation strategies to modernize ORNL facilities and energy use–intensive equipment to enable efficient, sustainable, and resilient operations in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing Lifetime and Reducing Costs for Fish Diversion Netting Structures (Abstract)

This effort will focus on technology transfer and commercialization of antifouling coatings with an enthusiastic and engaged industrial team. Environmental requirements and operational demands call for a nontoxic coating/paint to prevent fouling on fish passage guidance netting at hydropower facilities. For example, one netting customer estimated the capital cost for compliance at $\$12$ million to $\$15$ million. This project will build partnerships between PNNL and private companies to optimize, demonstrate, mature, and commercialize a novel PNNL-developed technology that addresses this critical coating need of the hydropower industry. This effort will support modification of existing coatings for application to flexible netting structures. Industrial partners include commercial coating development specialist (Lorama), hydrophobic material manufacturer and paint developer (Dry Surface Technologies), aquatic applications specialists (Prometheus Innovations and River Connectivity Systems), and hydropower netting producer (Pacific Netting Products). Engagement with the U.S. Army Corps of Engineers (USACE) and Bureau of Reclamation (BOR), two hydropower operators, throughout the project will provide expertise and field test sites that will provide crucial proof of real-world performance data (additional details provided in Teaming section). Taylor Shellfish Farms will provide organisms and fouling expertise as well as a perspective of potential broader impacts for the blue economy. Sample netting will demonstrate performance in a range of environments for key hydropower applications. PNNL will work with industrial partners to overcome commercialization barriers as well as resolving any manufacturing or regulatory issues. This Phase 1 effort is focused on technology optimization for application to fish passage guidance netting and technology validation as verified by independent testing (through USACE, BOR, Taylor Shellfish and Prometheus Innovations). Through this effort, SLIC will be demonstrated for netting applications at technology readiness level (TRL) 5. The field test data will allow optimization of SLIC formulation and performance which is key to enabling technology transfer of a mature proven technology to industry and production of a viable commercial product specifically focused for hydropower needs.

13 HYDRO ENERGY↗

Launch Alaska Transportation and Energy Accelerator (LATEA)

The Launch Alaska Transportation and Energy Accelerator (LATEA), funded through the U.S. Department of Energy Office of Technology Commercialization’s Energy Program for Innovation Clusters (EPIC),advanced deployment of innovative and efficient transportation and energy technology in Alaska from October 2021 through June 2025. The project was designed to leverage Launch Alaska’s accelerator model to identify, recruit, and support transportation technology companies with novel solutions to market needs while building the stakeholder networks, demonstration opportunities, and institutional capacity necessary to accelerate commercialization in one of the most challenging operating environments in the United States.

08 HYDROGEN↗

Experiences with a Flexible User Research Process to Build Data Change Tools

Scientific software development processes are understood to be distinct from commercial software development practices due to uncertain and evolving states of scientific knowledge. Sustaining these software products is a recognized challenge, but under-examined is the usability and usefulness of such tools to their scientific end users. User research is a well-established set of techniques (e.g., interviews, mockups, usability tests) applied in commercial software projects to develop foundational, generative, and evaluative insights about products and the people who use them. Currently these approaches are not commonly applied and discussed in scientific software development work. The use of user research techniques in scientific environments can be challenging due to the nascent, fluid problem spaces of scientific work, varying scope of projects and their user communities, and funding/economic constraints on projects.In this paper, we reflect on our experiences undertaking a multi-method user research process in the Deduce project. The Deduce project is investigating data change to develop metrics, methods, and tools that will help scientists make decisions around data change. There is a lack of common terminology since the concept of systematically measuring and managing data change is under explored in scientific environments. To bridge this gap we conducted user research that focuses on user practices, needs, and motivations to help us design and develop metrics and tools for data change. This paper contributes reflections and the lessons we have learned from our experiences. We offer key takeaways for scientific software project teams to effectively and flexibly incorporate similar processes into their projects.

97 MATHEMATICS AND COMPUTING↗

An Integrated Computer-Aided Design and Manufacturing Workflow for Synthetic Biology

Biological computer-aided design and manufacturing (bioCAD/CAM) tools facilitate the design and build processes of engineering biological systems using iterative design-build-test-learn (DBTL) cycles. In this book chapter, we highlight some of the bioCAD/CAM tools developed and used at the US Department of Energy (DOE) Joint Genome Institute (JGI), Joint BioEnergy Institute (JBEI), and Agile BioFoundry (ABF). We demonstrate the use of these bioCAD/CAM tools on a common workflow for designing and building a multigene pathway in a hierarchical fashion. Additionally, each tool presented in this book chapter is specifically tailored to support one or more specific steps in a workflow, can be integrated with the others into design and build workflows, and can be deployed at academic, government, or commercial entities.

59 BASIC BIOLOGICAL SCIENCES↗

AmeriFlux US-DBk Berkeley Way West

This is the AmeriFlux version of the carbon flux data for the site US-DBk Berkeley Way West. Site Description - This tower is located in dowtown Berkeley, CA on the roof of Berkeley Way West, an 8 story building. The surrounding area is urbanized and includes a major commercial corridor, residential areas, and the UC Berkeley campus within 1 km of the site. Multi-unit residential construction activities took place near the site on an intermittent basis throughout tower operation.

Goldstein, Allen [UC Berkeley]↗

Seismology in the Cloud: A New Streaming Workflow

Data-intensive research in seismology is experiencing a recent boom, driven in part by large volumes of available data and advances in the growing field of data science. However, there are significant barriers to processing large data volumes, such as long retrieval times from data repositories, complex data management, and limited computational resources. New tools and platforms have reduced the barriers to entry for scientific cluster computing, including the maturation of the commercial cloud as an accessible instrument for research. Here, we build a customized research cluster in the cloud to test a new workflow for large-scale seismic analysis, in which data are processed as a stream (retrieved on-the-fly and acted upon without storing), with data from the Incorporated Research Institutions for Seismology Data Management Center. We use this workflow to deploy a spectral peak detection algorithm over 5.6 TB of compressed continuous seismic data from 2074 stations of the USArray Transportable Array EarthScope network. Using a 50-node cluster in the cloud, we completed the noise survey in 80 hr, with an average data throughput of 1.7 GB per minute. By varying cluster sizes, we find the scaling of our analysis to be sublinear, due to a combination of algorithmic limitations and data center response times. The cloud-based streaming workflow represents an order-of-magnitude increase in acquisition and processing speed compared to a traditional download-store-process workflow, and offers the additional benefits of employing a flexible, accessible, and widely used computing architecture. It is limited, however, due to its reliance on Internet transfer speeds and data center service capacity, and may not work well for repeated analyses or those for which even higher data throughputs are needed. These research applications will require a new class of cloud-native approaches in which both data and analysis are in the cloud.

58 GEOSCIENCES↗

A low-cost centralized HVAC control system solution for energy savings, load shedding, and improved maintenance

University campuses rely on centralized controls for managing and optimizing complex HVAC systems in larger buildings. However, most campuses also have many smaller buildings with packaged HVAC systems controlled by a stand-alone thermostat. Even when these distributed and often overlooked systems have modern programmable thermostats, they cannot be centrally monitored or controlled, and they are typically not programmed adequately. This paper describes the implementation of a low-cost centralized control solution for these systems serving smaller campus buildings, mostly under 5,000 sf and representative of light commercial spaces. Thanks to advances in technology spurred by residential and commercial IoT developments, simple networked thermostat solutions exist that can easily replace original thermostats, and, connect these systems to a web-based portal for monitoring and control. We show that, with small customizations, these platforms can be integrated into facility management workflows. Beyond the energy savings potential from improved scheduling and closer management of these systems, there are significant advantages for maintenance crews since these systems can now be monitored on smart phones or tablets. A grid-responsive load-shedding program has also been implemented for additional cost savings. The networked thermostats can also be connected to additional systems such as economizer controls for improved ventilation management and energy savings. With data from these systems integrated centrally, it can also be used for improved analytics and fault detection. A toolkit has been developed to share the program with other campuses, whether for energy savings, improved management of ventilation, or a more proactive maintenance approach.

Fauchier-Magnan, Nicolas↗

Empowering Energy Efficiency in Existing Big-Box Retail/Grocery Stores (Final Optimization Report)

The Center for Sustainable Energy (CSE), in partnership with the National Renewable Energy Laboratory (NREL), TRC Energy Services, P2S Engineering Inc, Walmart, and five innovative technology providers, are to demonstrate the impact of an integrated suite of pre-commercial energy efficiency (EE) technologies in a large, existing, retail building located within an inland disadvantaged community. Proposed technology packages include three categories of advanced EE solutions: heating, ventilating, air-conditioning, and refrigerating (HVAC/R); lighting; and integrated system and building level controls. The project is designed to impact Walmart’s future store specifications, which can be replicated and deployed in other buildings across California with similar end-use and system characteristics. The following lists the technologies considered for this project: DualCool (HVAC evaporative cooling); Software Motor Company (SMC) (HVAC and refrigeration fan motor); I2S: DC LED lighting; LocBit: building energy management and optimization; Saya: water monitoring.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

U.S. Research Impact Alliance IMPACT Accelerator

The U.S. Research Impact Alliance (USRIA) was created with a vision to leverage successful models that accelerate technology development and commercialization, and support startup businesses based upon federal research investments. Building upon lessons learned and feedback from cohort teams, the USRIA programs have morphed into customized solutions that offer services which provide the most impact to startup businesses. Based upon discussions with small and startup businesses, entrepreneurs, and technology developers, a variety of resources have been developed to support each of these target audiences. USRIA created program differentiators to offer one-on-one engagement and direct communication with cohort teams, highly relevant conversations with targeted introductions, and minimal “class” time (only used when an issue is applicable to all cohort members).

43 PARTICLE ACCELERATORS↗

Assessment of Cold Spraying Mild-Steel Powder onto Mild-Steel Substrate for Development of Waste Tank Repair System - 20515

Infrastructure for nuclear waste storage and processing (e.g., waste tanks, transfer pipelines, evaporators) at the U.S. Department of Energy (DOE) Hanford Site has been in service well beyond its original design life. Past corrosion control methods at Hanford for waste tanks have not been fully successful, as evidenced by leaks forming in tank AY-102, the first double-shell tank (DST) constructed, and significant degradation detected in the primary tanks of AP-102 and AY-101. Failure of infrastructure components can pose a significant risk to the environment, worker safety, and project schedules. Therefore, remotely deployable methods for repairing and extending the service life of the existing tank waste infrastructure are needed. Cold spray has been identified as a potential technique for performing in situ repairs and material buildup for life extension of waste storage and processing infrastructure. Cold-spray repair methods and technology are well-established and are used extensively by industry and the military for making repairs using dissimilar materials. Pacific Northwest National Laboratory is evaluating the process of making repairs using mild-steel powder applied to a mild-steel substrate to minimize the galvanic corrosion potential. This paper presents the initial results for a feasibility ('go/no-go') assessment as to whether low-density deposits with sound metallurgic bonds, to build-back steel plate material, can be achieved using existing commercial cold-spray equipment. An assessment of steel-on-steel deposit is necessary to determine if cold spray is a viable candidate for DST carbon steel plate restoration/repair and thus DST service life extension. Powder properties and preparation requirements have been investigated and operating conditions and parameters for depositing a cold-spray buildup of mild steel on a mild-steel substrate have been determined. Soundness of metallurgic bonding as a function of the operating parameters exercised and results from applying cold spray to lay a deposit over simulated small-diameter flaws in 1/2-inch mild-steel plate are presented. Application of in situ cold-spray repair to the DOE complex has the potential to reduce cost and schedule impacts associated with component failures and the need to procure and construct replacement infrastructure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coal Enhanced PEEK Filament Production for Additive Manufacturing in Industrial Services

The project (Award DE-FE0032146), led by Baker Hughes in collaboration with the University of Wyoming, aims to develop composite PEEK (Polyether-ether-ketone) materials enhanced using coal-derived graphene-based additives suitable for additive manufacturing (3D printing). Coal char (CC), graphene oxide (GO), and reduced graphene oxide (rGO), derived from Powder River Basin (PRB) coal, were successfully integrated into commercial PEEK feedstock. The composite PEEK materials demonstrated tensile and flexural strengths and modulus, Shore hardness, and thermal properties similar to unfilled PEEK. Dielectric strength of 0.5% GO/PEEK is twice that of unfilled PEEK. However, tensile elongation and Izod impact toughness of the composite materials are lower than unfilled PEEK. The 10% CC/PEEK material also shows good recyclability albeit with slightly increased glass transition and cold crystallization temperatures. Filaments of the composite PEEK materials were fabricated using a Filabot system. 3D printing of the composite PEEK initially encountered feeding stoppage caused by the non-uniform diameter of the filament, which was resolved by reducing the nominal diameter from 1.75 to 1.65 mm. The printability of the composite PEEK filaments is limited in geometry and build time, driven by differences in base PEEK feedstock from the commercial PEEK filament at printing conditions. Prototype part printed using the composite filaments shows inconsistent bead width and bead interruption resulting in porosity. Preliminary process and economic evaluation using PRB coal char estimates the cost of GO to be $0.5/lb. Considering the small fraction expected in the composite PEEK, the GO cost is several orders of magnitude lower than the commercial PEEK filament. It is recommended that the printability of composite PEEK filaments to be improved by optimizing the composite PEEK material at the printing conditions and reducing the variations in filament extrusion. Also important is to identify the mechanisms of how coal-derived additives affect the composite PEEK performance and printing characteristics to allow customized material design and processing for target performance.

01 COAL, LIGNITE, AND PEAT↗

The Interplay Between Climate and Urban Expansion on Building Energy Demand in Morocco

Understanding building energy demand is critical for addressing climate uncertainty challenges and ensuring sustainable urban growth. This study develops a building energy demand (BED) model to explore how climate variation and urban expansion affect residential and commercial space heating and cooling demands in Morocco for three scenarios, namely, 2005, 2018, and 2018 + 1.5 °C. The results show that coastal cities have lower heating and cooling needs due to the oceanic influence, while interior cities require significantly higher heating demand per-unit-floorspace. Between 2005 and 2018, urban growth increased total heating and cooling demand by 218.8 GWh, particularly in northern and coastal regions, despite per-unit-floorspace reductions in milder climates and improved building efficiency in 2018. Residential heating remains the dominant energy use, though commercial demand is significant in urban centers. Under the 2018 + 1.5 °C hypothetical scenario, heating demand across Morocco declines by 335.8 GWh compared to 2018, with urban areas amplifying this trend. Meanwhile, cooling demand increases slightly by 44.4 GWh, with major cities experiencing relative increases of up to 50%. These findings highlight a trade-off where reduced winter heating needs are partly offset by increased summer cooling demands in densely urbanized areas. In conclusion, the study identifies key urban hotspots for targeted interventions, emphasizing the need for energy-efficient building designs, climate-adaptive urban planning, and resilient energy management strategies to sustainably address shifting seasonal energy patterns.

Morocco↗

Verification of a Modeling Toolkit for the Design of Building Electrical Distribution Systems

DC electrical distribution systems offer many potential advantages over their AC counterparts. They can facilitate easier integration with distributed energy resources, improve system energy efficiency by eliminating AC/DC converters at end-use devices (e.g., laptop chargers), and reduce installation material, time, and cost. However, DC electrical distribution systems present additional design considerations, largely resulting from potentially greater magnitude and variation in cable losses. Modeling and simulation are rarely used to design such systems. However, the greater dependency of DC system energy efficiency on design choices such as distribution voltages, architecture, and integration of PV and BESS suggests that modeling and simulation may be required. Such system performance analysis is currently not a standard practice, in part due to limited availability and validation of capable software tools. This paper characterizes the accuracy of a Modelica-based Building Electrical Efficiency Analysis Model (BEEAM) toolkit, as a precursor for validating its use to perform system performance analysis and inform design decisions. The study builds upon previous verification research by characterizing complete systems comprised of commercially available equipment, and providing a more detailed analysis of simulation results. Five lighting systems with varying electrical distribution architectures were designed using market-available equipment, installed in a laboratory environment, modeled using BEEAM, and simulated using three Modelica integrated development environments (IDEs). Simulated and measured results were compared to characterize toolkit accuracy. Initial results revealed that simulated performance was mostly within ±5% of measured system-level and device-level performance. While simulation results were not found to be dependent on the IDE, some Modelica compiler interoperability issues were identified. Although the BEEAM toolkit showed promise for the targeted use case, further work is needed to determine whether the demonstrated 5% accuracy is sufficient for making real-world design decisions, and for BEEAM to advance from an interesting research tool to one that can impact real-world building projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstration of a Novel Technology to Manage Electricity Demand in Grid-Independent Military Microgrids

This research was conducted by the National Renewable Energy Laboratory (NREL) in collaboration with the S&C Electric Inc. through funding provided by the ESTCP. The project demonstrates use of cybersecure Automated Demand Response (ADR) technology to effectively manage microgrid loads during grid-independent, also known as "islanded," operation. When military microgrids become isolated from the main electrical grid, they are required to balance electricity supply and demand locally. Given that local generation may be constrained, the prevailing strategy involves shedding all but the most critical loads by tripping smart circuit breakers, which then necessitate manual resetting. This approach is generally implemented at the building level, which means that the buildings with mission-critical activities are exempt from load management and remain fully powered, whereas those deemed non-critical can experience a complete loss of service. In this research we developed a method that allows building automation systems to selectively control their assets in response to load shedding request from a microgrid controller, avoiding total loss of service in contrast to the conventional control approach. A commercial OpenADR client server by GridFabric is used for communication between the microgrid controller and the building management system (BMS). The microgrid controller monitors both generation capacity and various assets within the microgrid and issues a demand reduction request when necessary. This request is communicated to the OpenADR server via Modbus. Upon receiving the request, the OpenADR server forwards it to the BMS utilizing the OpenADR protocol. The BMS is pre-configured with various levels of load reduction strategies based on the controllable assets available, allowing for a nuanced approach to demand reduction. Both lab and field tests were performed that considered load shedding needed to achieve closed transition into island mode and to accommodate changing loads and power source availability while islanded. A commercial microgrid controller was used for these tests with normal programming within the expected constraints of the system capabilities. That is, the solution did not require any specialized modification to the code base of the controller. Given the latency of the round-trip communication path between the microgrid controller and the various devices involved with the load shed processes, there are certain scenarios for which the demonstrated solution are appropriate and some which are not. The methods described in this report can be used for load shedding/restoration during transitions between islanded and grid-tied modes of operation, as well as accommodating normal variations in load and the need to remove a power source from operation for maintenance. These methods should not be used for scenarios that require load shedding within a second or two such as sudden and unanticipated significant load increases or loss of power sources through equipment faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fiscal Year 2023 Software Quality Assurance Activities for the ARC Software

The Argonne Reactor Code (ARC) software suite [1-17] has been developed by Argonne researchers for fast reactor design and analysis since the 1970s. With the ARC software suite, a user can quickly build a model of a proposed or existing fast spectrum reactor and carry out fuel cycle, nominal thermal analysis and flow requirements, and assess, as is appropriate, whether the core design and constraint system yield an acceptable mechanical behavior. For transient reactor analysis with SAS4A [18], the ARC software suite can be used to generate reactivity coefficients and kinetics parameters at any modeled fuel cycle time point which forms part of the input to SAS4A. The ARC suite was consistently being developed until the 1990s and followed a software QA program which was an appropriate standard for the time. In the 1990s, the DOE funding to fast reactor research and development was all but eliminated and the ARC software was put into maintenance mode. In the early 2000s, the software quality assurance (SQA) program for ARC was still in place to define an official version, but by 2005 it all but was abandoned as there were insufficient staff to fill the work roles. Since 2005, there has been a considerable increase in research and design work on fast spectrum reactors. The ARC software as a whole has since been exported to many universities and commercial companies and ANL support has been given to the various projects over the years [19-23]. Further, MC 2 -3, PERSENT, and DASSH were all developed after 2005 without any adherence to a software standard. In recent time, the DOE VTR project [22] paid for verification work to be done on the ARC software as part of the goal of making it NQA-1 complaint. The VTR project was not considered the appropriate pathway to fund and maintain a SQA program for the ARC software and while software developments (DASSH) were made and several manuals were updated and software verification work was carried out, the ARC software is not NQA-1 compliant. More recently the Advanced Reactor Development Program (ARDP [23]) has funded the creation of manuals for some ARC utility programs and funded additional software verification work on DIF3D [6, 7] and MC 2 -3 [2-5] for the purpose of commercial grade dedication. Because of the VTR and ARDP projects, software verification work was completed on MC 2 -3 and DIF3D, and detailed reports were created for each piece of software, which discuss the inputs and outputs from the codes that are covered by the verification work and link various analytic, code-to-code, and hand calculation based verification work presented in the report with verification test problems provided with the software. This is a key part of the commercial grade dedication work and constitutes the bulk of the cost to get the ARC software to commercial grade. The ARC software suite is a valuable asset as a fast reactor design and analysis tool set that has been reasonably well verified and validated with various fast reactor benchmark problems and experiments over decades. Some or all of the ARC software suite has been utilized for designing the IFR [20], PGSFR [21], VTR [22], and Natrium [23] reactors and we can expect it to continue to be used for advanced fast reactor design and/or confirmatory calculation purposes in the future. Due to increased interest by commercial companies and regulatory bodies, it is becoming more important to make the ARC software suite complete and ready-to-use in terms of its SQA pedigree and commercial grade dedication needs. This report discusses the achievements made towards building a new SQA program for the ARC software and dealing with outstanding identified QA gaps.