Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coil”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Modeling plasma response to non-axisymmetric magnetic field perturbations in tokamak boundaries

The primary goal of this project is to provide physics insight into models that elucidate the mechanisms responsible for controlling the performance of H-mode plasmas and edge localized mode (ELM) stability when subjected to intrinsic and applied non-axisymmetric magnetic perturbations. The overall goal is to facilitate the development of physics-based criteria for the design of magnetic coils to be used for ELM suppression and H-mode pedestal control in future burning plasma devices such as ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MELCOR Accident Progression and Source Term Demonstration Calculations for a FHR

MELCOR is an integrated thermal hydraulics, accident progression, and source term code for reactor safety analysis that has been developed at Sandia National Laboratories for the United States Nuclear Regulatory Commission (NRC) since the early 1980s. Though MELCOR originated as a light water reactor (LWR) code, development and modernization efforts have expanded its application scope to include non-LWR reactor concepts. Current MELCOR development efforts include providing the NRC with the analytical capabilities to support regulatory readiness for licensing non-LWR technologies under Strategy 2 of the NRC's near- term Implementation Action Plans. Beginning with the Next Generation Nuclear Project (NGNP), MELCOR has undergone a range of enhancements to provide analytical capabilities for modeling the spectrum of advanced non-LWR concepts. This report describes the generic plant model developed to demonstrate MELCOR capabilities to perform fluoride-salt-cooled high-temperature reactor (FHR) safety evaluations. The generic plant model is based on publicly-available FHR design information. For plant aspects (e.g., reactor building leak rate and details of the cover-gas system) that are not described in the FHR references, the analysts made assumptions needed to construct a MELCOR full-plant model. The FHR model uses a TRi-structural ISOtropic (TRISO)-particle fuel pebble-bed reactor with a primary system rejecting heat to two coiled tube air heat ex changers. Three passive direct reactor auxiliary cooling systems provide heat removal to supplement or replace the emergency secondary system heat removal during accident conditions. Surrounding the reactor vessel is a low volume reactor cavity that insulates the reactor with fire bricks and thick concrete walls. A refractory reactor liner system provides water cooling to reduce the concrete wall temperatures. Example calculations are performed to show the plant response and MELCOR capabilities to characterize a range of accident conditions. The accidents selected for evaluation consider a range of degraded and failed modes of operation for key safety functions providing reactivity control, the primary system decay heat removal and also a piping leak of the line to the coolant drain tank.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal conductivity of RHIC superconducting magnet insulation materials at low temperatures

The Electron-Ion Collider (EIC) is planned to be built upon the Relativistic Heavy Ion Collider (RHIC), which vacuum chamber will need to be upgraded to host the EIC hadron beams. For the beam pipe section running through the RHIC superconducting (SC) magnets, the baseline is to insert a screen that will get cooled by thermal contact to the 4.55 K beam pipe of RHIC. Knowing the material properties of the cold mass is thus crucial to understand which is the final temperature that the screen and the superconducting coils in the magnets will reach during the passage of the EIC beams. The thermal conductivities of two insulation materials in the RHIC superconducting magnets and a reference material were measured at cryogenic temperatures at the Magnet Science and Technology division of the National High Magnetic Field Laboratory (NHMFL). The measurements were performed in a Quantum Design physical property measurement system. This report explains the motivation behind this work and summarizes the measurement method and results.

43 PARTICLE ACCELERATORS↗

Thermal analysis of RHIC arc dipole magnet cold mass with EIC beam screen

The existing RHIC storage rings – including their superconducting magnet arcs – will be used for the hadron storage ring of the Electron-Ion Collider (EIC). The vacuum chamber of these magnets was not designed for the EIC hadron beams, with shorter bunches and of higher average current than the RHIC beams. With the current stainless steel beam pipe, the resistive-wall (RW) heating will exceed the dynamic heat load budget. Limiting the RW heating is important to prevent the superconducting magnets from quenching and to maintain a low screen temperature necessary to impede the rise of RW heating (higher resistance at higher temperature) as well as to achieve desired ultra-high vacuum. In addition, simulations predict the formation of electron cloud which would further contribute to the dynamic heat load and could compromise the quality and stability of the beam. To reduce the resistive-wall heating and suppress electron cloud, a beam screen will be installed in the vacuum chamber of the RHIC SC magnets. The screen will have a high RRR copper layer at its inner face – useful to reduce the resistive-wall impedance thanks to its high conductivity especially at cryogenic temperatures – and will be coated with a thin layer of amorphous carbon, a material with low secondary electron yield to suppress the formation of electron clouds. The baseline solution envisages a screen that will be cooled by thermal contact to the 4.55 K beam pipe. Detailed thermal analysis have been conducted in ANSYS 2020 for an arc dipole cold mass equipped with a beam screen in order to study the feasibility of a passively-cooled screen and guide its design. Temperature-dependent thermal conductivity properties of all materials in the operating (cryogenic) temperature range are considered. Suitable assumptions and simplifications are made to model the magnet coil and calculate its homogenized thermal conductivity. Sensitivity studies with respect to layer thicknesses and area of contact are carried out and results are presented.

43 PARTICLE ACCELERATORS↗

Implementation of ASHRAE Guideline 36 Control Logic into Oak Ridge National Laboratory (ORNL)’s Flexible Research Platform (FRP)

This report presents the initial field test procedure and results for ASHRAE Guideline 36 control logic. The US Department of Energy’s Oak Ridge National Laboratory’s (ORNL’s) two-story Flexible Research Platform (FRP-2) was selected as a test building. The rooftop unit (RTU) system serves as the building’s primary cooling system, and each variable air volume (VAV) box with an electric reheat coil serves as the building’s heating system along with RTU gas furnace. In this study, the control for the RTU and VAV box adopted the practical control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. Each story of the FRP-2 building has 5 office zones (thermal zones), for a total of 10 zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control

This is the final report for the project “All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control”, funded by DOE, and performed by Clemson University, Phase IV Engineering and Harvard University from October 1, 2016 to December 31, 2020. The main objective of this project is to develop, demonstrate and pre-commercialize a novel, plug & play, battery-free, wireless sensor technology to enable low-cost (<$10 per node) indoor and outdoor temperature and humidity measurement for energy efficient building controls and operations. The proposed technology is based on the novel concept of all-digital sensing and its seamless integration with the passive RFID technology. This project focuses on the design, fabrication, material optimization, interrogation electronics, validation, and demonstration of the novel sensor nodes for building applications. The specific objectives of this research program include: (1) Design, fabricate and optimize a compact, robust, and high-resolution digitizer, which could convert rotation angle into digital numbers. (2) Develop the multi-physics-based modeling and simulation of the temperature/humidity transducer to derive a rational design of the architecture, dimension, structure, materials (i.e., mechanical, electrical, thermal and hygroscopic) properties and functions of the sensor node. (3) Design, fabricate and optimize the bi-material based humidity sensitive coil which could linearly transduce the environmental relative humidity variations to rotation angles. (4) Design, fabricate and optimize an UHF RFID platform which could support long-range passive wireless communications of 8-bit digital numbers. (5) Design, fabricate and optimize the miniaturized all-digital sensor using MEMS technology. (6) Validate the integrated all-digital sensing system in a real building environment to test the system’s performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

US HL-LHC Accelerator Upgrade Project (MQXFA Final Design Report)

The MQXFA Quadrupole magnets will be installed in High Luminosity LHC to form the Q1 and Q3 inner triplet optical elements in front of the interaction points 1 (ATLAS) and 5 (CMS). A pair of MQXFA units is assembled in a stainless steel helium vessel, including the end domes, to make the Q1 Cold Mass or the Q3 Cold Mass. The US HL LHC Accelerator Upgrade Project* is responsible for the design, manufacturing and test of the Q1/Q3 Cold Masses and the complete MQXFA magnets. CERN provides the cryostat components and is responsible for integration and installation in HL LHC. The MQXFA quadrupoles have 150 mm aperture, 4.2 m magnetic length, nominal gradient of 132.2 T/m, and coil peak field of 11.3 T. They use Nb_3Sn conductor and a support structure made of segmented aluminum shells pre-loaded by using bladders and keys. This report presents the final design of the MQXFA quadrupole magnets.

43 PARTICLE ACCELERATORS↗

Mutual Inductance Level Sensor for Use in Liquid Metals

Electromagnetic instrumentation capable of measuring the level of liquid metal has been developed at Argonne National Laboratory’s (ANL) Mechanisms Engineering Test Loop (METL). The mutual inductance level sensor (MILS) utilizes the electromagnetic coupling between two coil conductors and a surrounding liquid metal to determine the level of the liquid metal. Mineral insulated cables wrapped on a stainless steel core provide a durable sensor construction. The use of a sealed stainless steel thimble isolates the sensor from the high-temperature liquid metal, allowing for easy sensor maintenance. Modern digital electronics allow for reliable and accurate operation of the sensor. Two sensor variations have been designed and fabricated, and the first variation has seen extensive testing in a non-sodium testing stand as well as in the high-temperature sodium environment of METL. Electromagnetic finite-element analysis studies have been performed using the COMSOL Magnetic Fields Solver. Regular operation of the MILS will commence following in-situ calibration of the sensors in the METL environment.

36 MATERIALS SCIENCE↗

Wastewater Recycling Using a Hygroscopic Cooling System

This project by the Energy & Environmental Research Center (EERC), Baltimore Aircoil Company (BAC), and Great River Energy (GRE) evaluated the concept of recycling wastewater at a coal-fired power plant using a hygroscopic cooling system, which is an evaporative cooling technology analogous to conventional cooling towers, except that sparingly soluble dissolved solids are precipitated and removed as waste solids instead of purging them with a liquid blowdown stream. This technology can maximize the use of plant makeup water by obtaining useful evaporative cooling from wastewater while minimizing the volume of wastes needing disposal. Experimental activities were conducted in two phases, a laboratory-based evaluation of the properties of wastewater from the host site, GRE’s Coal Creek Station near Underwood, North Dakota, and a field test of a small pilot hygroscopic cooling system at the host site power plant. Findings from the laboratory study informed the design of the pilot system and the system’s field test performance served as the basis for a techno-economic analysis (TEA) of the hygroscopic recycling concept. At the preferred operating conditions identified during the TEA, the wet-bulb approach temperature of the tower was 7.3°C (13°F) and the volume of blowdown produced by the plant was reduced to 5.4% of its incoming volume. Waste solids produced during field testing were classified as nonhazardous waste based on the measured hazardous element content and evaluation of their leaching potential. However, to qualify as a solid for landfill disposal i.e., as determined by the U.S. Environmental Protection Agency’s paint filter test, it appears that a dewatering step beyond hydrocyclone separation is needed. The baseline levelized cost of wastewater disposal (LCWD) for hygroscopic wastewater recycling was estimated to be $\$ $3.69–$\$ $3.72 per m3 of plant blowdown. Capital cost was estimated to contribute over 54% to the LCWD, and parameters that impact capital cost such as the heat exchange coil material of construction and the tower’s wet-bulb approach temperature were identified as having the greatest impact on overall LCWD. A LCWD estimate prepared for the same application but using thermomechanical brine evaporation was almost 40% higher than that calculated for hygroscopic cooling, despite recovering distilled-quality water for reuse, while the LCWD for disposal-only, deep well injection was estimated to be 30% lower compared to hygroscopic wastewater recycling.

01 COAL, LIGNITE, AND PEAT↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mo-100 Disk Structural Integrity Tests II

This report is a continuation of the work performed in the report, Mo-100 Disk Structural Integrity Tests I [1]. The NorthStar pressed and sintered 29 mm diameter, 0.5 mm thick Mo-100 disks will be subjected to large temperature gradients when in-beam during production. These large temperature gradients cause high stress and deformation within the disks that could prove detrimental to the target assembly’s cooling performance. Disk fracture is also a possibility that must be understood. Therefore, disk structural integrity tests were performed to understand the thermal induced behavior of these disks. In order to replicate the in-beam conditions, the Mo-100 disks were subjected to large temperature gradients using a 30kW induction heater and coil. A series of transient tests were conducted in a similar fashion as the previous work, as well as an attempt to create steady state conditions for more accurate temperature gradients. The transient thermal test setup and results are described in this report.

36 MATERIALS SCIENCE↗

US HL-LHC Accelerator Upgrade Project: MQXFA11 shipping incident report

The truck transporting the MQXFA11 magnet from LBNL to BNL was involved in an accident on 7/20/22. It was rear ended by another truck. Drivers were not injured. The main hit took place on the right back corner. The truck with the MQXFA11 magnet was towed to a tow yard in Rockdale, IL (~50 min drive from Fermilab). Subsequently, it was moved on another truck and moved to Fermilab. Fermilab employees added 3 accelerometers on the crate before it was moved on the new truck and attended all loading/unloading operations at the tow yard and at FNAL. The magnet arrived at FNAL on July 28 th . Upon arrival a visual inspection was performed. Accelerometers were removed and shock data were analyzed. Electrical checkout and a metrology survey were carried out. Strain data were also collected from the fiber optics installed on two coils and compared with data obtained before shipment. This report presents a summary of results. More pictures and details can be found at: https://indico.fnal.gov/event/55698/

43 PARTICLE ACCELERATORS↗

MQXFA Series Magnet Production Specification: US HL-LHC Accelerator Upgrade Project

The purpose of this document is to define the specifications for the structure fabrication and assembly of MQXFA series magnets to be used by the US High-Luminosity LHC Accelerator Upgrade Project (AUP). Magnets fabricated according to these specifications are expected to allow MQXFA magnets to meet the MQXFA Functional Requirements Specification. These specifications for the fabrication of MQXFA series magnets are based on the R&D performed by the US LHC Accelerator Research Program (LARP) and the development performed by AUP, in collaboration with CERN, through fabrication and test of pre-series coils and magnets.

43 PARTICLE ACCELERATORS↗

Stellarator Simplification using Permanent Magnets (PM4Stell)

This Report describes the design and prototyping of an array of rare-Earth permanent magnets to form a stellarator. This effort was motivated by the hypothesis that the usage of permanent magnets, rather than electromagnetic coils with complex geometry, could reduce the cost of stellarator construction and thereby make increase the feasibility of the stellarator as a technology for a fusion-based power plant. In this project, we have developed novel methods for specifying the positions, shapes, and polarizations of the magnets in the array, and have developed designs for mounting structures and tooling for assembly. We have also performed detailed finite-element modeling to qualify the accuracy of the magnetic field produced by the magnet array as designed, and to confirm that the structure can withstand the forces between the magnets. We have also developed techniques for measuring the magnetic field produced by the array once constructed, as well as for correcting errors in the field arising from misalignments and offsets within the tolerances for mounting and fabrication. Finally, we have constructed a tabletop prototype of a section of the array to qualify the concept for assembling and mounting magnets within the array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Power Generation Cycle with RELAP-7

Balance of plant of a High-Temperature gas-cooled Reactor – Pebble bed Module (HTR-PM) is modeled using RELAP-7. The model includes the primary helium loop where the heat produced by the core is transferred to a helical-coil steam generator and the secondary loop where super-heated steam is fed to a turbine to extract power. The steam is then condensed to subcooled water and pumped back into the steam generator. Results demonstrate that RELAP-7 has the capability to model different regimes encountered in two-phase flow with wall boiling, superheated steam, subcooled liquid and condensation. RELAP-7 also has the capability of modeling different fluids with their own specific models in a very flexible way, without any code change. This also demonstrates the capability of modeling the transfer of fission power into electrical power.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Electron beam irradiation of 1,4 dioxane

Electron beam irradiation produces both, reducing and oxidizing species which facilitate the reduction of contaminants found in water and wastewater. To investigate the impact of electron beam on 1,4-dioxane, a widely used solvent which has been declared as a probable human carcinogen by the U.S. Environmental Protection Agency, a beamline was designed and commissioned at the Upgraded Injector Test Facility at Jefferson Lab. Here, wastewater samples can be irradiated with a beam energy up to 10 MeV and a beam current of up to 100 nA. Beam acceleration is achieved by two superconducting radio-frequency cavities cooled by liquid helium in a cryomodule. A beam spot with a diameter of ~5 cm was produced at the target location using a pair of raster coils. Electron beam irradiation studies were performed using 1,4-dioxane in two different matrices, de-ionized water and secondary effluent wastewater, and for two concentrations, 10 microg/L and 100 microg/L. The concentration of 1,4-dioxane after irradiation was measured as a function of dose.

Li, Xi↗

MQXFA11 shipping incident report

The truck transporting the MQXFA11 magnet from LBNL to BNL was involved in an accident on 7/20/22. It was rear ended by another truck. The magnet arrived at FNAL on July 28th. Upon arrival a visual inspection was performed. Accelerometers were removed and shock data were analyzed. Electrical checkout and a metrology survey were carried out. Strain data were also collected from the fiber optics installed on two coils and compared with data obtained before shipment. This report presents a summary of results.

43 PARTICLE ACCELERATORS↗