Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CURRENT AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Atmospheric Emission Photometric Imaging on Spacelab (AEPI)

Two parallel detector systems are used for atmospheric emission photometric emission. The top system is a TV system using the image intensified S.E.C. tube as the detector. The bottom system, the photon counting array (P.C.A.), uses a microchannel plate intensified anode array tube and is equivalent to a 100 channel photomultiplier. For the television, the filters are selected by means of a filter wheel set. The field of view of the is interchangeable between 20 and 6 degrees, by means of a moveable prism. The quartz window mu channel plate intensifier is fiber optically coupled to a 40-25 demagnifying tube which is in turn coupled to the S.E.C. tube. The PCA channel has a fixed field of view of 4 deg and a remote control interchangeable photometric converter optics which converts the imaging array into a multichannel photometer. The mu channel plate array tube amplifies the photons into detectable counts for the PCA electronics. The entire system is pointed by a two axis gimbal. The flight equipment to be acquired consists of a gyro package and an interactive flight control unit panel. The gyro package is necessary because of the inadequate attitude reference supplied by the current Spacelab systems.

Mende, S. B.↗

Short wavelength 128 by 128 focal plane arrays for remote sensing applications

Short-wavelength (1-2.5-micron) 128x128 focal plane arrays have been fabricated and demonstrated with high pixel yields and dark-current-limited performance. The detector material is HgCdTe grown by LPE on a sapphire substrate which yields high-performance uniform detectors. The detector arrays were characterized at temperatures of 80-150 K; the peak quantum efficiency at 2.4 microns is 80 percent. The multiplexer is a Reticon FET switch with output amplifiers. It is noted that the long-term goal of this project is to develop a 150x1000 mosaicked focal plane for use in the HIRIS instrument on the Earth Observing System.

Bothwell, Mary↗

A high-frequency, secondary instability of crossflow vortices that leads to transition

Three-dimensional boundary-layer transition experiments are currently being conducted on a 45 deg swept wing in the Arizona State University Unsteady Wind Tunnel. Crossflow-dominated transition is produced via a model with contoured end liners to simulate infinite swept-wing flow. Fixed-wavelength, stationary and travelling crossflow vortices are observed. The frequencies of the most amplified travelling waves are in agreement with linear-stability theory; however travelling waves at frequencies an order of magnitude higher than predicted are also observed near transition. Near the transition location, the distorted boundary layer is due to the stationary crossflow vortex and is subject to a Rayleigh-type instability in the stream direction. As a result, a high-frequency secondary instability is detected in the transition region and spatial relations of the process are well documented by coupled use of flow visualization and hot-wire measurements.

Kohama, Yasuaki↗

Laser-Ablated Ba(0.50)Sr(0.50)TiO3/LaAlO3 Films Analyzed Statistically for Microwave Applications

Scanning phased-array antennas represent a highly desirable solution for futuristic near-Earth and deep space communication scenarios requiring vibration-free, rapid beam steering and enhanced reliability. The current state-of-practice in scanning phased arrays is represented by gallium arsenide (GaAs) monolithic microwave integrated circuit (MMIC) technology or ferrite phase shifters. Cost and weight are significant impediments to space applications. Moreover, conventional manifold-fed arrays suffer from beam-forming loss that places considerable burden on MMIC amplifiers. The inefficiency can result in severe thermal management problems.

Romanofsky, Robert R.↗

Co-Investigator Proposal for Enstrophy - - Filamentation of Auroral Currents

Cornell University provided three instruments for the Enstrophy experiment: an electric field meter, a plasma wave receiver, and a magnetometer for measuring FAC. The electric field meter consisted of a 6 m Weitzmann boom system with analog signal processing and 12 bit ADC, which yielded one electric field component instantaneously and a two dimensional electric field every half spin. The plasma wave receiver used the same sensing system with the addition of pre-amplifiers in the spheres to sense plasma waves up to and including the electron Langmuir frequency. Signal processing employed a variety of continuous and snap shot techniques depending on the frequency range and band width. The science magnetometer provided by Cornell University was a Billingsly design fluxgate previously used on spacecraft missions but without radiation hardening. The magnetometer was mounted on a one meter, stiff aluminum "flop-down" boom. The Enstrophy payload was launched on february 11, 1999. Because of a design flaw in the event timers, the magnetometer boom was deployed before the payload despun. As a result the magnetometer separated mechanically from the boom but maintained electrical connection. This was confirmed by the calculation of the scalar magnetic field from all three vector components of the magnetic field. However, the individual vector values had no scientific value. The electric field and plasma wave instrumentation worked as designed. The data from these instruments was provided to the University of New Hampshire and to the Principal Investigator, as proposed.

Kintner, Paul M.↗

Investigation of pulsed mode operation with the frequency tuned CAPRICE ECRIS

In order to increase the intensity of the highly charged ions produced by the Electron Cyclotron Resonance Ion Sources (ECRISs), techniques like the frequency tuning and the afterglow mode have been developed and in this paper the effect on the ion production is shown for the first time when combining both techniques. Recent experimental results proved that the tuning of the operating frequency of the ECRIS is a promising technique to achieve higher ion currents of higher charge states. On the other hand, it is well known that the afterglow mode of the ECRIS operation can provide more intense pulsed ion beams in comparison with the continuous wave (cw) operation. These two techniques can be combined by pulsing the variable frequency signal driving the traveling wave tube amplifier which provides the high microwave power to the ECRIS. In order to analyze the effect of these two combined techniques on the ion source performance, several experiments were carried out on the pulsed frequency tuned CAPRICE (Compacte source A Plusiers Résonances Ionisantes Cyclotron Electroniques)-type ECRIS. Different waveforms and pulse lengths have been investigated under different settings of the ion source. The results of the pulsed mode have been compared with those of cw operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accessing Secondary Markets as a Capital Source for Energy Efficiency Finance Programs: Program Design Considerations for Policymakers and Administrators

Estimates of the total opportunity for investment in cost-effective energy efficiency in the United States are typically in the range of several hundred billion dollars (Choi Granade, et al., 2009 and Fulton & Brandenburg, 2012).1,2 To access this potential, many state policymakers and utility regulators have established aggressive energy efficiency savings targets. Current levels of taxpayer and utility bill-payer funding for energy efficiency is only a small fraction of the total investment needed to meet these targets (SEE Action Financing Solutions Working Group, 2013). Given this challenge, some energy efficiency program administrators are working to access private capital sources with the aim of amplifying the funds available for investment. In this context, efficient access to secondary market capital has been advanced as one important enabler of the energy efficiency industry “at scale.”3 The question of what role secondary markets can play in bringing energy efficiency to scale is largely untested despite extensive attention from media, technical publications, advocates, and others. Only a handful of transactions of energy efficiency loan products have been executed to date, and it is too soon to draw robust conclusions from these deals. At the same time, energy efficiency program administrators and policymakers face very real decisions regarding whether and how to access secondary markets as part of their energy efficiency deployment strategy.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dc and microwave characteristics of a high current double interface GaAs/InGaAs/AlGaAs pseudomorphic modulation-doped field-effect transistor

Extremely large current double interface GaAs/In(0.15)Ga(0.85)As/Al(0.15)Ga(0.85)As pseudomorphic modulation-doped field-effect transistors (MODFET's) grown by molecular beam epitaxy were achieved. The 1-micron gate devices studied have peak current levels (430 mA/mm at 300 K and 483mA/mm at 77 K) roughly one and a half to two times that found in single interface pseudomorphic MODFET's. These devices also retain high transconductances over a broad range of gate voltage, peaking at 312 mS/mm at 300 K and 362 mS/mm at 77 K. Excellent microwave performance is also obtained with a maximum frequency of oscillation (f-max) of 37 GHz and a current gain cut-off frequency of as high as 23 GHz at 300 K. An output power level of 14 dBm (1 dB gain compression) was obtained at 6 GHz for a 290-micron gate width. This double interface single quantum well MODFET may be of great importance in millimeter wave power amplifiers.

Henderson, T.↗

Models for X-Ray Emission from Isolated Pulsars

A model is proposed for the observed combination of power-law and thermal X-rays from rotationally powered pulsars. For gamma-ray pulsars with accelerators very many stellar radii above the neutron star surface, 100 MeV curvature gamma-rays from e(-) or e(+) flowing starward out of such accelerators are converted to e1 pairs on closed field lines all around the star. These pairs strongly affect X-ray emission from near the star in two ways. (1) The pairs are a source of synchrotron emission immediately following their creation in regions where B approx. 10(exp 10) G. This emission, in the photon energy range 0.1 keV less than E(sub X) less than 5 MeV, has a power-law spectrum with energy index 0.5 and X-ray luminosity that depends on the back-flow current, and is typically approx. 10(exp 33) ergs/ s. (2) The pairs ultimately a cyclotron resonance "blanket" surrounding the star except for two holes along the open field line bundles which pass through it. In such a blanket the gravitational pull on e(+,-) pairs toward the star is balanced by the hugely amplified push of outflowing surface emitted X-rays wherever cyclotron resonance occurs. Because of it the neutron star is surrounded by a leaky "hohlraum" of hot blackbody radiation with two small holes, which prevents direct X-ray observation of a heated polar cap of a gamma-ray pulsar. Weakly spin modulated radiation from the blanket together with more strongly spin-modulated radiation from the holes through it would then dominate observed low energy (0.1-10 keV) emission. For non-y-ray pulsars, in which no such accelerators with their accompanying extreme relativistic back-flow toward the star are expected, optically thick e1 resonance blankets should not form (except in special cases very close to the open field line bundle). From such pulsars blackbody radiation from both the warm stellar surface and the heated polar caps should be directly observable. In these pulsars, details of the surface magnetic field evolution, especially of polar cap areas, become relevant to observations. The models are compared to X-ray data from Geminga, PSR 1055-52, PSR 0656+14, PSR 1929+10, and PSR 0950+08.

Wang, F. Y.-H.↗

Fault Tolerant Homopolar Magnetic Bearings

Magnetic suspensions (MS) satisfy the long life and low loss conditions demanded by satellite and ISS based flywheels used for Energy Storage and Attitude Control (ACESE) service. This paper summarizes the development of a novel MS that improves reliability via fault tolerant operation. Specifically, flux coupling between poles of a homopolar magnetic bearing is shown to deliver desired forces even after termination of coil currents to a subset of failed poles . Linear, coordinate decoupled force-voltage relations are also maintained before and after failure by bias linearization. Current distribution matrices (CDM) which adjust the currents and fluxes following a pole set failure are determined for many faulted pole combinations. The CDM s and the system responses are obtained utilizing 1D magnetic circuit models with fringe and leakage factors derived from detailed, 3D, finite element field models. Reliability results are presented vs. detection/correction delay time and individual power amplifier reliability for 4, 6, and 7 pole configurations. Reliability is shown for two success criteria, i.e. (a) no catcher bearing contact following pole failures and (b) re-levitation off of the catcher bearings following pole failures. An advantage of the method presented over other redundant operation approaches is a significantly reduced requirement for backup hardware such as additional actuators or power amplifiers.

Li, Ming-Hsiu↗

Ka-Band SiGe Receiver Front-End MMIC for Transponder Applications

A fully integrated, front-end Ka-band monolithic microwave integrated circuit (MMIC) was developed that houses an LNA (low noise amplifier) stage, a down-conversion stage, and output buffer amplifiers. The MMIC design employs a two-step quadrature down-conversion architecture, illustrated in the figure, which results in improved quality of the down-converted IF quadrature signals. This is due to the improved sensitivity of this architecture to amplitude and phase mismatches in the quadrature down-conversion process. Current sharing results in reduced power consumption, while 3D-coupled inductors reduce the chip area. Improved noise figure is expected over previous SiGe-based, frontend designs

Venkatesan, Jaikrishna↗

Fully differential rail-to-rail output amplifier with inverter-based input pair

A fully differential rail-to-rail-output amplifier includes a differential input inverter pair, folded cascode pair, class AB control pair, and class AB output rail-to-rail pair. A drain associated with the folded cascode pair is operatively coupled to the class AB control pair, and the drain associated with the folded cascode pair is unconnected to the current source associated with the class AB control pair. A method of providing fully differential rail-to-rail-output amplification includes coupling a folded cascode pair operatively to a differential input inverter pair, coupling a drain associated with the folded cascode pair operatively to a class AB control pair, and coupling a class AB output rail-to-rail pair operatively to the class AB control pair.

Dabrowski, Mieczyslaw M.↗

Sensitivity of Proposed Search for Axion-induced Magnetic Field using Optically Pumped Magnetometers

We investigate the sensitivity of a search for the oscillating current induced by axion dark matter in an external magnetic field using optically pumped magnetometers. This experiment is based upon the LC circuit (circuit with inductor and capacitor) axion detection concept of Sikivie et al. [Phys. Rev. Lett. 112, 131301 (2014)]. The modification of Maxwell’s equations caused by the axion-photon coupling results in a minute magnetic field oscillating at a frequency equal to the axion mass, in the presence of an external magnetic field. The axion-induced magnetic field could be searched for using a LC circuit amplifier with an optically pumped magnetometer, the most sensitive cryogen-free magnetic-field sensor, in a room-temperature experiment, avoiding the need for a complicated and expensive cryogenic system. Here, we discuss how an existing magnetic resonance imaging experiment can be modified to search for axions in a previously unexplored part of the parameter space. Our existing detection setup, optimized for magnetic resonance imagining, is already sensitive to an axion-photon coupling of 10 -7 GeV -1 for an axion mass near 3 × 10 -10 eV, which is already limited by astrophysical processes and solar axion searches. We show that realistic modifications, and optimization of the experiment for axion detection, can probe the axion-photon coupling up to 4 orders of magnitude beyond the current best limit, for axion masses between 10 -1 and 10 -7 eV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Phase modulation failsafe system for multi-kJ lasers based on optical heterodyne detection

Amplification of the transverse scattered component of stimulated Brillouin scattering (SBS) can contribute to optical damage in the large aperture optics of multi-kJ lasers. Because increased laser bandwidth from optical phase modulation (PM) can suppress SBS, high energy laser amplifiers are injected with PM light. Phase modulation distributes the single-frequency spectrum of a master oscillator laser among individual PM sidebands, so a sufficiently high modulation index β can maintain the fluence for all spectral components below the SBS threshold. To avoid injection of single frequency light in the event of a PM failure, a high-speed PM failsafe system (PMFS) must be employed. Because PM is easily converted to AM, essentially all PM failsafes detect AM, with the one described here employing a novel configuration where optical heterodyne detection converts PM to AM, followed by passive AM power detection. Although the PMFS is currently configured for continuous monitoring, it can also detect PM for pulse durations ≥2 ns and could be modified to accommodate shorter pulses. This PMFS was deployed on the Z-Beamlet Laser (ZBL) at Sandia National Laboratories, as required by an energy upgrade to support programs at Sandia’s Z Facility such as magnetized liner inertial fusion. Depending on the origin of a PM failure, the PMFS responds in as little as 7 ns. In the event of an instantaneous failure during initiation of a laser shot, this response time translates to a 30–50 ns margin of safety by blocking a pulse from leaving ZBL’s regenerative amplifier, which prevents injection of single frequency light into the main amplification chain. In conclusion, the performance of the PMFS, without the need for operator interaction, conforms to the principles of engineered safety.

47 OTHER INSTRUMENTATION↗

On the possibility of designing a high-resolution heterodyne spectrometer for near-IR range on the basis of a tunable diode laser

The results of heterodyning of broadband radiation in the near-IR range are presented. A stabilised DFB laser was used as a local oscillator, while the role of a broadband radiation source was played by another DFB laser, excited by the pump current below its threshold value. A fibre-optical Y-coupler based on the single-mode silica fibre served as a diplexer. The radiation mixed in the singlemode fibre was incident on the photodetector, the role of which was played by a p - i - n photodiode. The signal from the photodiode was amplified by the preamplifier with the feedback resistance 240 k{Omega} and the bandwidth {approx}1 MHz and then digitised using a 16-digit ADC. The frequency scanning was implemented via the variation of the local oscillator frequency. The developed registration system provides the sensitivity {approx}1.4 % of the shot noise value at the acquisition time {approx}40 min.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of electron beam polarization using electron detector in Compton polarimeter with less than 1% statistical and systematic uncertainty

The Q-weak experiment aims to measure the weak charge of proton with a precision of 4.2%. The proposed precision on weak charge required a 2.5% measurement of the parity violating asymmetry in elastic electron - proton scattering. Polarimetry was the largest experimental contribution to this uncertainty and a new Compton polarimeter was installed in Hall C at Jefferson Lab to make the goal achievable. In this polarimeter the electron beam collides with green laser light in a low gain Fabry-Perot Cavity; the scattered electrons are detected in 4 planes of a novel diamond micro strip detector while the back scattered photons are detected in lead tungstate crystals. This diamond micro-strip detector is the first such device to be used as a tracking detector in a nuclear and particle physics experiment. The diamond detectors are read out using custom built electronic modules that include a preamplifier, a pulse shaping amplifier and a discriminator for each detector micro-strip. We use field programmable gate array based general purpose logic modules for event selection and histogramming. Extensive Monte Carlo simulations and data acquisition simulations were performed to estimate the systematic uncertainties. Additionally, the Moller and Compton polarimeters were cross calibrated at low electron beam currents using a series of interleaved measurements. In this dissertation, we describe all the subsystems of the Compton polarimeter with emphasis on the electron detector. We focus on the FPGA based data acquisition system built by the author and the data analysis methods implemented by the author. The simulations of the data acquisition and the polarimeter that helped rigorously establish the systematic uncertainties of the polarimeter are also elaborated, resulting in the first sub 1% measurement of low energy (?1 GeV) electron beam polarization with a Compton electron detector. We have demonstrated that diamond based micro-strip detectors can be used for tracking in a high radiation environment and it has enabled us to achieve the desired precision in the measurement of the electron beam polarization which in turn has allowed the most precise determination of the weak charge of the proton.

43 PARTICLE ACCELERATORS↗

Top quark forward-backward asymmetry from SU(N{sub c}) color

We argue that the tt production asymmetry observed at the Tevatron might be simply explained if the standard SU(3){sub c} QCD theory is extended to SU(N{sub c}) which is spontaneously broken at a scale just above the weak scale. The extended gauge interactions amplify the radiative QCD contribution to the asymmetry and can potentially explain the observations if N{sub c} > or approx. 5. This explanation suggests a relatively low SU(N{sub c}) symmetry breaking scale < or approx. 0.5-1 TeV. We check that such a low SU(N{sub c}) symmetry breaking scale is consistent with current collider data. Importantly this scenario predicts an abundance of striking phenomena which will be probed at the LHC. The SU(N{sub c}) model also illustrates the idea that a beyond standard model contribution to the tt asymmetry might arise primarily via radiative corrections rather than at tree level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Understanding the electron-water interaction at the molecular level: Integrating theory and experiment in the cluster regime

In this final technical report, we summarize our major accomplishments resulting from a combined experimental-theoretical approach that exploits the unique properties of molecular clusters to elucidate how local interactions at the molecular level drive the macroscopic behavior of materials and chemical transformations in liquids. The specific targets for our efforts have need to elucidate how charged entities are accommodated by hydrogen-bonding networks and to establish how the behavior of room temperature ionic liquids can be tailored for specific chemical applications. Because of their central importance in aqueous electrolyte chemistry, we have placed particular emphasis understanding the accommodation of excess electrons and protons by water. These surprisingly complex fundamental electrical charges play a fundamental role in a wide range of chemical and biological processes, and yet even a qualitative picture of their speciation in water and at the air-water interface has proven elusive. The main experimental diagnostic in our approach is to measure and analyze vibrational spectra of temperature and composition controlled molecular aggregates that isolate and amplify the spectral markers for local interactions that are often obscured in measurement on bulk or interfacial water. Our combined experimental-theoretical program has led to a greatly enhanced understanding of the nature of excess electrons and protons in water and in the process developed new and powerful methods of chemical analysis that are currently in use across the chemical sciences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗