Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 901 records · Page 50

Modeling the Nucleation and Growth of Lead Sulfate Particles on Lead Electrodes

Lead-acid batteries (LABs) play a pivotal role in the energy storage sector with applications spanning from starting-lighting-ignition batteries to grid energy storage. Passivation of lead negative electrodes by PbSO 4 particles is a fundamental mechanism limiting the performance of LAB. In this regard, an electrochemical model is developed that simulates the nucleation and growth (N&G) dynamics of PbSO 4 particles on a flat lead electrode, responsible for its passivation. The model considers the electrochemical reactions between lead electrode and sulfuric acid, N&G of PbSO 4 particles, passivation of the lead surface, and the ternary transport of PbSO 4 (aq), bisulfate, and protons in H 2 SO 4 electrolyte. The model is validated with a dataset of cyclic voltammetry (CV) responses collected at several scan rates and H 2 SO 4 concentrations. The model shows remarkable qualitative and quantitative agreement with the experimental data including CV peak features, discharge capacity, and particle size. The model was employed to explore key N&G quantities, such as supersaturation, nucleation rate, particle count, growth rate, particle size, and surface coverage, and to examine how their interactions influence electrode utilization. Parametric studies were also conducted to evaluate how scan rates and acid concentrations influence the previously mentioned N&G quantities and, subsequently, the utilization of the electrode.

25 ENERGY STORAGE↗

Non-destructive Assay Measurements Using the RPI Lead Slowing Down Spectrometer

The use of a Lead Slowing-Down Spectrometer (LSDS) is consid- ered as a possible option for non-destructive assay of fissile material of used nuclear fuel. The primary objective is to quantify the 239Pu and 235U fissile content via a direct measurement, distinguishing them through their characteristic fission spectra in the LSDS. In this pa- per, we present several assay measurements performed at the Rensse- laer Polytechnic Institute (RPI) to demonstrate the feasibility of such a method and to provide benchmark experiments for Monte Carlo cal- culations of the assay system. A fresh UOX fuel rod from the RPI Criticality Research Facility, a 239PuBe source and several highly en- riched 235U discs were assayed in the LSDS. The characteristic fission spectra were measured with 238U and 232Th threshold fission cham- bers, which are only sensitive to fission neutron with energy above the threshold. Despite the constant neutron and gamma background from the PuBe source and the intense interrogation neutron flux, the LSDS system was able to measure the characteristic 235U and 239Pu responses. All measurements were compared to Monte Carlo simula- tions. It was shown that the available simulation tools and models are well suited to simulate the assay, and that it is possible to calculate the absolute count rate in all investigated cases.

Lead Slowing Down Spectrometer↗

Inferring small-sample-reactivity worth from oscillation experiment with auto-corrected local flux

To estimate reactivity changes as a function of time from the signal of detectors count rates, one usually uses point kinetic equations. However, when detectors are located inside the core, it is often necessary to compute a correction factor to account for the flux-shape deformation (i.e. the change of detector efficiency that may have been induced by neutron absorbers movements). Various simulation methods have been developed depending on transients observed. They range from the resolution of static equations up to full-time-dependent neutron transport in 3D. However, those methods require high computational-cost calculations of local reaction rates that rely on nuclear data evaluations. Therefore, a 'measured' reactivity is never determined through pure measurements. Taking advantage of the known oscillation movement of a small sample at the center of the MINERVE reactor, the innovative algorithm presented in this paper derives the correction factor needed to get no time drift on reactivity steps. Derived correction factors are in good agreement with those obtained independently with TRIPOLI-4 through sensitivity analysis. Low sensitivity to the sample composition and moderate sensitivity to the detectors position reinforce the reliability of those results. This application paves the way to almost pure nuclear data reactivity measurements. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of an ideal observer that incorporates nuisance parameters and processes list-mode data

Observer models were developed to process data in list-mode format in order to perform binary discrimination tasks for use in an arms-control-treaty context. Data used in this study was generated using GEANT4 Monte Carlo simulations for photons using custom models of plutonium inspection objects and a radiation imaging system. We evaluated observer model performance and then presented using the area under the receiver operating characteristic curve. Lastly, we studied the ideal observer under both signal-known-exactly conditions and in the presence of unknowns such as object orientation and absolute count-rate variability; when these additional sources of randomness were present, their incorporation into the observer yielded superior performance.

61 RADIATION PROTECTION AND DOSIMETRY↗

Superconducting nanowire single-photon detector enhanced near-infrared II portable confocal microscopy for tissue imaging with indocyanine green

In this Letter a novel, to our knowledge, approach for near-infrared (NIR) fluorescence portable confocal microscopy is introduced, aiming to enhance fluorescence imaging of biological samples in the NIR-II window. By integrating a superconducting nanowire single-photon detector (SNSPD) into a confocal microscopy, we have significantly leveraged the detection efficiency of the NIR-II fluorescence signal from indocyanine green (ICG), an FDA-approved dye known for its NIR-II fluorescence capabilities. The SNSPD, characterized by its extremely low dark count rate and optimized NIR system detection efficiency, enables the excitation of ICG with 1 mW and the capture of low-light fluorescence signals from deep regions (up to 512 µm). Consequently, our technique was able to produce high-resolution images of bio samples with a superior signal-to-noise ratio, making a substantial advancement in the field of fluorescence microscopy and offering a promising opportunity for future clinical study.

Liu, Yifan (ORCID:0000000328877704)↗

POWGEN: a third-generation high resolution high-throughput powder diffraction instrument at the Spallation Neutron Source

Powgen represents a departure from previous designs for a time-of-flight powder diffractometer at a spallation neutron source and may be considered a third-generation design. The instrument is optimized for both parametric studies of materials under a wide range of conditions (T, P, H, flowing gases, etc) and ab-initio crystal structure determinations of complex solid-state materials with asymmetric unit-cells of the order {approx}1500 {angstrom}{sup 3}. The geometric design of the instrument allows for all detected scattered neutrons to be focused onto a single diffraction profile yielding high count rate while preserving good resolution {Delta}d/d = 0.0015 at a d = 1 {angstrom}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis strategy for ultrafast X-ray photon correlation spectroscopy

We explain an analysis strategy for ultrafast X-ray photon correlation spectroscopy, a technique enabled by X-ray free electron lasers to probe nano- and atomic-scale dynamics in complex systems on nanosecond timescales or faster. Central to the technique is the methodology for extracting contrast in coherent X-ray diffraction patterns, known as speckle patterns. Guided by simulations, we analyze common challenges and examine errors encountered in contrast extraction. A method for accurately determining contrast amid shot noise across a wide range of count rates is presented.

36 MATERIALS SCIENCE↗

Temperature Control of Crystal Optics for Ultrahigh-Resolution Applications

The temperature control of crystal optics is critical for ultrahigh resolution applications such as those used in meV-resolved Inelastic Scattering. Due to the low count rate and long acquisition time of these experiments, for 1-meV energy resolution, the absolute temperature stability of the crystal optics must be maintained below 4 mK to ensure the required stability of lattice constant, thereby ensuring the energy stability of the optics. Furthermore, the temperature control with sub-mK precision enables setting the absolute temperature of individual crystal, making it possible to align the reflection energy of each crystal’s rocking curve in sub-meV resolution thereby maximizing the combined efficiency of the crystal optics. In this contribution, we report the details of an EPICS control system using PT1000 sensors, Keithley 3706A 7.5 digits sensor scanner, and Wiener MPOD LV power supply for the analyzer crystals of the Inelastic X-ray Scattering (IXS) beamline 10-ID at NSLS-II**. We were able to achieve absolute temperature stability below 1 mK and sub-meV energy alignment for several asymmetrically cut analyzer crystals. The EPICS ePID record was used for the control of the power supplies based on the PT1000 sensor input that was read with 7.5 digits accuracy from the Keithley 3706A scanner. The system enhances the performance of the meV-resolved IXS spectrometer with currently a 1.4 meV total energy resolution and unprecedented spectral sharpness for studies of atomic dynamics in a broad range of materials.

Gofron, Kaz↗

Expected Results From Channeling Radiation Experiments at Fast

The photoinjector at the new Fermilab FAST facility will accelerate electron beams to about 50 GeV. After initial beam commissioning, channeling radiation experiments to generate hard X-rays will be performed. In the initial stage, low bunch charge beams will be used to keep the photon count rate low and avoid pile up in the detector. We report here on the optics solutions, the expected channaling spectrum including background from bremmstrahlung and the use of a Compton scatterer for higher bunch charge operation.

43 PARTICLE ACCELERATORS↗

Precision Photometry to Study the Nature of Dark Energy

Over the past decade scientists have collected convincing evidence that the expansion of the universe is accelerating, leading to the conclusion that the content of our universe is dominated by a mysterious 'dark energy'. The fact that present theory cannot account for the dark energy has made the determination of the nature of dark energy central to the field of high energy physics. It is expected that nothing short of a revolution in our understanding of the fundamental laws of physics is required to fully understand the accelerating universe. Discovering the nature of dark energy is a very difficult task, and requires experiments that employ a combination of different observational techniques, such as type-Ia supernovae, gravitational weak lensing surveys, galaxy and galaxy cluster surveys, and baryon acoustic oscillations. A critical component of any approach to understanding the nature of dark energy is precision photometry. This report addresses just that. Most dark energy missions will require photometric calibration over a wide range of intensities using standardized stars and internal reference sources. All of the techniques proposed for these missions rely on a complete understanding of the linearity of the detectors. The technical report focuses on the investigation and characterization of 'reciprocity failure', a newly discovered count-rate dependent nonlinearity in the NICMOS cameras on the Hubble Space Telescope. In order to quantify reciprocity failure for modern astronomical detectors, we built a dedicated reciprocity test setup that produced a known amount of light on a detector, and to measured its response as a function of light intensity and wavelength.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The use of TI-208 gamma rays for safeguards, nondestructive-assay (NDA) measurements

This paper examines two cases where gamma rays from Tl-208, including the 2614keV gamma ray, were used to detect anomalies in waste material. In addition to the characterization of waste for waste acceptance, and compliance with environmental and transportation laws, there is a safeguards element as well. The more sophisticated method of NDA at Y-12 includes a means to detect shielded special nuclear material (SNM). Excess count rates in the 2614keV gamma ray from Tl-208 are an indication of potential shielded HEU in waste as well as other containers. The 2614keV gamma ray is easy to monitor routinely. When a large 2614keV peak is detected, further investigation can be conducted from the gamma spectrum. This paper describes this further investigation in two cases. In one case self-shielded HEU was detected. In the other case the Tl-208 gamma rays came from a piece of Th-232 metal.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Small-angle Compton Scattering to Determine the Depth of a Radioactive Source in Matter

A gamma-ray peak in a spectrum is often accompanied by a discontinuity in the Compton continuum at the peak. The Compton continuum results from Compton scattering in the detector. The discontinuity at a peak results from small-angle Compton scattering by the gamma rays in matter situated directly between the gamma-ray source and the detector. The magnitude of this discontinuity with respect to the gamma-ray peak is therefore an indicator of the amount of material or shielding between the gamma-ray source and the detector. This small-angle scattering was used to determine the depth of highly-enriched uranium (HEU) solution standards in a concrete floor mockup. The empirical results of the use of this small-angle scattering discontinuity in a concrete floor experiment will be described. A Monte Carlo calculation of the experiment will also be described. In addition, the depth determined from small-angle scattering was used in conjunction with differential attenuation to more accurately measure the uranium content of the mockup. Following these empirical results, the theory of small-angle scattering will be discussed. The magnitude of the discontinuity compared to the peak count rate is directly related to the depth of the gamma-ray source in matter. This relation can be described by relatively simple mathematical expressions. This is the first instance that we are aware of in which the small-angle Compton scattering has been used to determine the depth of a radioactive source. Furthermore this is the first development of the theoretical expressions for the magnitude of the small-angle scattering discontinuity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intelligent Integrated Machining: Handheld XRF for Mapping Zr Coating and Al-6061 Cladding Thickness in RERTR Fuel Elements

An inexpensive commercially available handheld energy dispersive x‐ray fluorescence spectrometer is used to provide a rapid non‐destructive estimate of coating and/or cladding thickness in situ . The portable XRF instrument contains a battery‐operated low‐power polychromatic source coupled with a Peltier‐cooled silicon drift detector; built‐in analysis software based upon the Method of Fundamental Parameters converts measured spectral intensities to elemental concentrations, reported as normalized weight percentages. Using detected signals from elements unique to the base material and coating or cladding materials, calibration curves and associated empirical algorithms for determining the thickness of the high‐purity zirconium coating on an RERTR fuel element prior to cladding with aluminum, and for determining the thickness of the Al‐6061 cladding after HIP for a known zirconium layer thickness, are constructed. For Zr over bare DU‐10Mo, agreement between the measured and the calculated thickness is ± 5% or better. For the multilayer system consisting of Al‐6061 over Zr over Du‐10Mo, agreement between calculated and measured thickness is ± 10‐15% over the thickness range of interest. Simultaneous estimates for the Al cladding and underlying Zr coating can be made using the elemental composition output only when the Mo signal is in the quasi‐static range (corresponding to Al thicknesses of ~15 mils (0.381 mm) and greater) and not so low that measurement error is greater than the signal itself; under these conditions, accuracy is on the order of ±15 – 20%. More accurate determination of both Zr and Al thickness simultaneously may be possible if the count‐rates associated with individual fluorescent lines in the multilayer sample are available rather than just the weight percent composition currently output by the XRF analyzer software.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Capture Cross Section of 239 Pu

The Detector for Advanced Neutron Capture Experiments (DANCE) has been used to measure the 239 Pu(n,γ) cross section from 10 eV to the keV region. Three experimental run conditions were used to characterize the prompt fission γ-ray spectrum across the entire energy regime, measure the cross section in the resolved resonance region, and obtain necessary count rate well into the keV region. The preliminary cross sections are in good agreement with current evaluations from 10 eV to 80 keV.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fast, Low Noise Photodetectors for Nuclear Physics

The overall goal of the Phase-II project was to construct and evaluate high performance SSPM technology for nuclear physics experiments. To achieve this overall objective, we first undertook optimization of the SSPM technology. This effort involved further enhancement of the optical quantum efficiency as well as the geometric efficiency (or fill-factor) of the SSPMs, which resulted in improvement of the photodetection efficiency of the SSPMs. Important SSPM parameters such as gain, dark count-rate, cross-talk, temporal response, after-pulsing, quantum efficiency and photodetection efficiency were evaluated for the optimized devices and these parameters were compared with those for Phase-I prototypes. Large area SSPMs (1 to 2 cm 2 ) were built using optimal design parameters. Noise analysis of large area SSPMs was performed. Upon coupling SSPMs to various scintillators (LSO/LYSO, LaBr 3 :Ce, NaI:Tl, LuAG:Ce etc.), energy resolution studies were carried. Timing resolution was also be measured with SSPMs coupled to fast scintillators (such as LaBr 3 :Ce, BaF 2 , LuAG:Ce, plastic and LSO/LYSO) using 511-keV gamma-rays ( 22 Na source). Multi-element SSPM arrays (6 x 6 format with ~1.5 x 1.5 mm 2 elements) were also designed and built using the CMOS process. These SSPM arrays were packaged and appropriate readout electronics was assembled. These SSPM arrays were operated with individual readout of each SSPM element. Large area (~1 cm 2 ) micro-pixel level PS-SSPMs with active and passive components to enable on-chip charge sharing for position sensing were also designed and built. Spatial, energy and timing resolution studies were conducted with the multi-element SSPM arrays as well as PS-SSPMs coupled to segmented scintillation arrays.

99 GENERAL AND MISCELLANEOUS↗

Comparison between Neutron Counting Experimental Measurements and Simulations: Cosmic Ray Contribution

In this report we model old experimental neutron count distribution data with simulations. Included in the simulations are spontaneous fission induced fission chains and cosmic ray induced neutron signals. The experimental data on highly enriched uranium (HEU) was taken at LLNL at sea level, and on Pu at LANL at 7300 feet in altitude. Cosmic rays can create neutron bursts in high-Z materials, which are enhanced in multiplying Special Nuclear Materials (SNM). For HEU at sea level, comparison between simulations and experimental data show that the largest burst events are initiated by cosmic rays, not by spontaneous fission of 238 U. Attempts to quantitatively model the HEU experimental data show that additional contributions from cosmic ray induced neutron background in a concrete room improve the comparison significantly. Cosmic rays interacting with the room create a neutron background that dominates the count rate, and can also initiate fission in HEU; the concrete walls can also shield the highenergy hadrons (protons, neutrons, and pions) that create the largest neutron bursts. For HEU of low multiplication, cosmic rays make it easier to detect HEU, but harder to analyze. For a high multiplication Pu ball, even at altitude, the spontaneous fission-initiated fission chains totally dominate the signal – in this regime cosmic rays are unimportant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Euratom Fast Collar (EFC) Calibration Report

Neutron collars are used by international inspectorates to determine the amount of 235U in fresh LWR fuel assemblies. Standard neutron collars can operate in two modes: “fast” and “thermal”. In fast mode (using cadmium liners), thermal neutron are excluded from the assembly and the measurement results are not very sensitive to the presence of neutron poison loaded pins. In thermal mode, the thermal neutrons are affected by the presence of poison rods leading to significant effect, requiring corrections. These corrections depend on the declaration of the operator, reducing the independence of the inspectors’ measurements. The thermal mode signal is much higher than the fast mode signal and can give statistically acceptable results in ~600 seconds compared with ~1 hr for the fast mode. This report describes the calibration of a new fast neutron collar designed to use fast mode to reduce the effect of poison pins on verification measurements and with increased efficiency to reduce the measurement times to those normally used on inspection. The work was done in cooperation with the safeguards division of the European Commission and so the new collar is named the Euratom Fast Collar (EFC). The motivation and design work is presented in reference 2. The Monte Carlo simulations presented in reference 2 cover a larger parameter range than can be experimentally measured with the mock up assembly and so we base the performance on the simulation results, benchmarked to the measurements. The work presented here follows that of the “bible” of LWR fuel assembly measurements and uses the same mock-up assembly, with the same enriched, depleted and gadolinium poisoned fuel rods as were used in that work. Reference 1 describes how the measured count rate of the detector is corrected for AmLi source strength, electronic stability, efficiency, poison rods effects and heavy metal effects as well as other perturbing factors. These will be discussed below. INCC is the normal software that is used to collect and analyze neutron collar data. The results of this work have been formulated to fit into this existing INCC data analysis framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗